Safety Technology International STI Stopper Dome Heated Enclosure Data Sheet

FIRE PRODUCTS
®
STI STOPPER
DOME
HEATED ENCLOSURE
STI-1229HTR
HAZARD
Typ e 4X
FILE E228169
PATENT PENDING
ADA
Compliant
STI-1229HTR-HA Z
STI-1229HTR 240HAZ
PRODUCT OVERVIEW
Now there is a way to protect your signaling device located where temperature or environmental conditions exceed the suggested operation range. This protective cover with heater assembly for strobe appliances, is UL Listed to U.S. and Canadian Safety Standards. Thermostatically controlled heaters and a continuous duty fan maintain a uniform temperature in the cover when located in a cold environment. Applications include, but are not limited to, refrigerators, freezers, meat packaging plants, arctic environments, ocean rigs, slaughterhouses, etc. UL/cUL Listed down to -70°F (-57°C) applicable both indoors and outdoors.
Typ e 4X
FILE S 7025
PATENT PENDING
ADA
Compliant
STI-1229HTR
STI-1229HTR 240
KEY FEATURES
General Information
· For use in areas where temperature or environmental conditions exceed the operational range of fire UL Listed strobe signaling devices.
· Maintains operating strobe appliance temperature with external temperatures to -70°F (-57°C).
esign
DA C
ompliance for
DA C
ompliant strobes to
· Enables A visual fire protection systems where freezing temperatures or other harsh conditions exceed the operating limits of strobe signal devices.
· CSFM requires local approval only.
· Heater unit cycles as required to maintain the correct range of operating temperatures.
· Prevents buildup of snow on the unit or entry of moisture in wash down areas to assure that strobes remain clearly visible.
· Fan runs continuously to maintain a uniform temperature inside the enclosure.
· Three year guarantee against breakage of polycarbonate in normal use (one year on electro mechanical and electronic components).
D
· Dust tight (Class II Group F and G Di v. 2) .
· All Class III locations.
Construction
· Enclosure rated to Type 4X Standards. Heater assembly rated down to -70°F (-57°C).
· UL/cUL ambient rating -70°F to 120°F (-57°C to 49°C) indoors or outdoors.
· Units UL Listed to U.S. and Canadian safety standards for specific strobes only (see chart on reverse).
Installation
· Protects A UL 1971 Standards.
· The thick, clear polycarbonate cover is UV-stabilized.
· Typical working proper ties of polycarbonate are -40° to 250°F (-40° to 121°C).
STI Stopper® Dome Heated Enclosure
Dimensions and Technical Information
MODELS AVAILABLE
ST I -12 29 Stopper Dome for strobe only with
ST I -12 29 - H A Z Stopper Dome for strobe only with
STI-1229HTR Stopper Dome heated enclosure for
STI-1229HTR-HAZ Stopper Dome heated enclosure for
STI-1229HTR240 Stopper Dome heated enclosure for
STI-1229HTR240-HA Z Stopper Dome heated enclosure for
KIT-H18021 Type 4X 3/4” rigid conduit hub (included
ST I -12 84 Single Gang Mounting Adapter
ELECTRICAL ENTRY
IN AREAS WHERE FREQUENT
ASH DOWNS OCCUR
W
WASHERS MAY BE USED TO
STAND OFF ENCLOSED SPACER
(NOT PROVIDED)
1/4 in. (6.3mm)
DIA. HOLE
ANCHOR
(4) PROVIDED
SCREW #10 x 1 1/2 in.
(4) PROVIDED
LOW VOLTAGE TERMINAL BLOCK
3/4 in. NPT. NIPPLE
(NOT PROVIDED)
enclosed back box, Type 4X
enclosed back box, Type 4X hazardous locations
strobe only, Type 4X
strobe only, Type 4X hazardous locations
strobe only, Type 4X
strobe only, Type 4X hazardous locations
with hazardous model)
LOW VOLTAGE
HIGH VOLTAGE
ELECTRICAL ENTRY
SEALING HUB (NOT PROVIDED)
3/4 in.(25mm) NPT NIPPLE (NOT PROVIDED)
3/4 in. NPT HUB (2) PROVIDED
ENCLOSED BACK BOX
LOW TEMP
WARNING
THERMOSTAT
WARNING LABEL
SEALING HUB (NOT PROVIDED)
APPLIANCE
WIRE
HEATER ASSEMBLY
FAN
HIGH VOLTAGE TERMINAL BLOCK
APPROVALS & WARRANTY
TESTING
It has been tested and approved or listed by:
· UL and cUL, Type 4X, and UL 50 File S7025
· UL and cUL Hazardous File E228169
· For hazardous applications in Canada, to meet cUL, your strobe must be ULC Listed.UL and cUL, Type 4X, and UL 50 File S7025
WARRANTY
Three year guarantee against breakage of polycarbonate in normal use (one year on electro mechanical and electronic components).
PERFORMANCE REVIEW FOR STI-1229HTR & STI-1229HTR240
Manufacturer
WHEELOCK (RSS 24MCW)
ADT SECURITY (ADTG1-V Series ), EST/Edwards ( G1-V Series, G1-HV Series, G1-HOV Series, EG1-V Series, EG1-HV Series, EG1-HOV Series), Honeywell (XLSG1-V Series, XLS1-HV Series), Mircom ( MG1-V Series, MG1-HV Series, MG1-HOV Series) , Mirtone (MG1-V Series), Siemens (G1-V Series)
FARADAY LLC (2700) EST/ EDWARDS ( 2440 S, 202 Series), HONEYWELL ( XL S202 Series),
MIRCOM (MS Series), SIEMENS (202 Series), ZI TON PTY LTD ( ZG1-V-SERIES )
AMSECO (SL24W-153075), AMSECO COLORED LENSES (SLW24-153075 A, B, G OR R, SL24C-3075110 A, B, G OR R, CSL24W- A, B, G OR R, CSL24C
- A, B, G OR R ), HONE YWELL (X LSG1-HOV SERIES), MIRCOM (FS-240 ),
POTTER ELECTRIC (AS-24-153075R, AS-24-153075W)
PERFORMANCE REVIEW FOR STI-1229HTR-HAZ & STI-1229HTR240-HAZ
FARADAY LLC (2700)
SYSTEM S EN SO R ( SS24110ADA )
AMSECO ( SL24W-153075 ), GENTEX ( GES24-15/75 W, R OR P)
FUSE
CONTROL THERMOSTAT
SCREW #8-32 x 3/8 in. (4) PROVIDED
STROBE APPLIANCE
GASKET (1) PROVIDED
SOLID CLEAR COVER
WASHER (6) PROVIDED
#8-32 x 5/8 in. SOCKET CAP SCREW (6) PROVIDED
Light Loss %
31%
32%
33% 34%
37%
33%
35%
36%
Printed in U.S.A., © 1987-2020 Safety Technology International, Inc.
03 /19Subject to change without notice.
Loading...