SABAF S.p.A.
Via dei Carpini, 1
25035 Ospitaletto (Brescia) Italia
TECHNICAL CHARACTERISTICS
INSTRUCTIONS FOR USE, ASSEMBLY INSTRUCTIONS,
MAINTENANCE INSTRUCTIONS
MODEL 46 – 46R – 46M
MANUALLY OPERATED GAS VALVE WITH FLAME
SURVEILLANCE DEVICE

SABAF S.p.A.
hot plates, ovens, grills etc.
minimum working temperature (body)
maximum working temperature (body)
17.30 ft3/h (490 l/h) (test gas: air - pressure drop 250 Pa)
calculated nominal capacity
21,688 Btu/h (test gas: air - pressure drop 250 Pa)
2.78 ft3/h (79 l/h) (test gas: air – pressure drop 250 Pa)
calculated nominal capacity (reduced)
3,496 Btu/h (test gas: air - pressure drop 250 Pa)
opening angle of max. flow rate
opening angle of min. flow rate
210° (160° R version – 290° M version)
leakage 60 cc/h (air - pressure 3 psi (20.7 kPa))
leakage 20 cc/h (air - pressure 3 psi (20.7 kPa))
gas valve continued operation
Flame supervisor device continued
operation
bracket, flange (see attached sheets)
storage temperature range
hold-on current/drop-out current (safety
device)
< 180 mA / > 60 mA (version 1)
< 110 mA / > 20 mA (version 2)
< 60 mA / > 10 mA (version 3)
Themocouples maximum closing time
TABLE 1 - MICROSWITCH CHARACTERISTICS
Max. operating temperature
Via dei Carpini, 1
25035 Ospitaletto (Brescia) Italia
INSTRUCTIONS FOR USE
To turn the valve on, simultaneously press and turn the control shaft. Holding down the control shaft and
turning it anti-clockwise allows the gas to pass to the burner. A few seconds after the burner ignites, the
thermocouple generates enough current to hold the safety magnet open. The control shaft needs no longer be
pressed down.
If indicated in the assembly drawing, to turn the valve on is necessary, starting from the close position (0°A), to
turn the operating spindle anti-clockwise up to 90°A; only in this position the safety valve can be opened and
consequently is possible to held-on the magnet.
If the valve has a microswitch, press down on the control shaft activating the microswitch which drives the
thermoelectric lighting device (see table 1).
Maximum flow-rate is reached after turning the control shaft through 90°; reduced flow-rate is reached by
continuing the rotation up to 210° (160° mod 46R – 290° mod 46M).
If the flame should accidentally go out, the thermocouple cools and the current is reduced, the safety magnet
is closed and the flow of gas is blocked after a few seconds.
The valve has an adjustable perforated metering screw (by-pass) which fixes the reduced flow-rate at a preset
value when fully tightened. If a different type of gas is used, the amount of reduced flow can be adjusted by
turning the by-pass with a screwdriver.