Rycote PCS-Boom Connector, PCS-Organizer, PCS-Lite, PCS-Spigot, PCS-Utility User guide

...
Page 1
Professional Connection System
Quick Start Guide
Professional Connection System
Page 2
Quick Start Guide
PCS-Boom Connector (RYC185801) PCS-Organizer (RYC185800) PCS-Lite 3/8” (RYC185802) PCS-Lite 5/8” (RYC185812) PCS-Spigot (RYC185803) PCS-Utility (RYC185804) PCS-Utility Half Coupler Kit Small (RYC185809) PCS-Utility Half Coupler Kit Large
Thank you for choosing the Rycote Professional Connection System (PCS)! This guide provides you with the basics to get you started.
For more information go to:
www.rycote.com
(RYC185810)
Page 3
Overview
The Professional Connection System (PCS) is the ingenious quick attach and release system by Rycote.
Depending on which PCS connector you have simply attach the connector to the suitable accessory or surface (3/8” / 5/8” / Spigot / at surface). Ax the included male tip (3/8” or 5/8”) to your desired accessory with the compatible thread/t.
Intuitive, one-handed ‘click-in’ attachment and release mechanism, provides fast and incredibly easy operation and a rock-solid, noise-free connection in use.
Page 4
PCS-Boom
PCS-Boom Connector (RYC185801)
In the Box
1
2
1. PCS-Boom Connector collar
2. Grey outler collar
3. 3/8” Tip with Hytrel® washer
4. Hex/Allen Key
4
3
Page 5
PCS-Organizer
PCS-Organizer (RYC185800)
In the Box
4
1
5
2
3
1. PCS-Organizer quick release collar
2. ‘Dual-lock’ ring
3. Flat surface mounting base
4. 3/8” Tip with Hytrel® washer
5. 2 x pair of steel washers
Page 6
PCS-Lite 3/8” - PCS-Lite 5/8”
PCS-Lite 3/8” (RYC185802) PCS-Lite 5/8” (RYC185812)
In the Box
1
2
1. PCS-Lite quick release collar
2. PCS-Lite female 5/8” thread (3/8” adaptor included only with RYC185802).
3. 3/8” Tip (inc. with RYC185802 only)
4. 5/8” Tip (inc. with RYC185812 only)
3
4
Page 7
PCS-Spigot
PCS-Spigot (RYC185803)
In the Box
1
4
2
1. PCS-Spigot quick release collar
2. 5/8” (16mm) spigot connector
3. Hex/Allen key
4. 3/8” Tip with Hytrel® washer
3
Page 8
PCS-Utility
PCS-Utility (RYC185804)
In the Box
1
4
2
1. PCS-Utility quick release collar
2. 3/8” female connector
3. Hex/Allen key
4. 3/8” Tip with Hytrel® washer
3
Page 9
Page 10
31
1
31
Screw the PCS-Boom Connector on to the male
3/8” thread of the boom pole, in a clockwise rotation/
direction - to the desired position.
4
Screw the PCS ‘tip into the female 3/8” thread of your windshield, shock mount, or other accessory that you
would like to use with your PCS-Boom Connector.
Attaching the PCS Connector:
2
PCS-Boom Connector, PCS-Lite and PCS-Utility – connect to a male
3/8” thread in a clockwise rotation.
PCS-Spigot – connect to a 5/8” (16mm) male spigot and use the includ­ed hex key to fully secure connection as shown above.
PCS-Boom Connector & PCS-Utility Use included hex key to tighten the two small locking screws on the connector, providing a extra secure connection.
PCS-Organizer – surface, using washers (included) and suit­able screws (not included). When mounting vertically always position so that screws are aligned one above another, as shown above.
WARNING: Mounting screws are not included. Always use washers included. Do NOT use countersunk screws. Recommended screw size: M4 15mm
connect to a at
Page 11
5
To attach the two components, simply line up the tip
with the Connector and push the tip in to lock it.
You will hear a click as it locks together!
31
5
6
Screw the PCS ‘tip into the female 3/8” thread of your windshield, shock mount, or other accessory that you
would like to use with your PCS-Boom Connector.
To attach the two components, simply line up the tip
with the Connector and push the tip in to lock it.
You will hear a click as it locks together!
2
Attaching PCS Tip:
3
1. Screw the PCS ‘tip’ into the female * 3/8” thread of your windshield, shock mount, stand, arm or other accessory. * For PCS-Lite 5/8” – screw ‘tip’ into an accessory with a 5/8” thread.
4
2. To tighten connection, use a screw driver (not included), and insert this through the circular hole in the tip, as shown. Turn clockwise to tighten rmly (do not over-tighten).
Page 12
Connection and lock:
To attach the two components, simply line up the tip with the Connector and push the tip in to lock it. You will hear a “click” as it locks toghether!
PCS-Organizer – to engage the ‘accidental release’ Dual-Lock after the ‘tip has been inserted, turn the locking ring anti-clockwise, until you hear a ‘click’.
Page 13
PCS-Boom Connector
5
6
To attach the two components, simply line up the tip
with the Connector and push the tip in to lock it.
You will hear a click as it locks together!
4
Quick Release:
PCS-Boom Connector and PCS-Lite – to release, pull down on the PCS collar, as shown.
PCS-Organizer – to release, twist the ‘dual-lock’ locking ring clockwise until your hear a ‘click’. Then pull down on the PCS collar.
PCS-Spigot and PCS-Utility – to release, twist knurled collar anti-clock­wise and pull down in one movement, as shown.
Page 14
Care of your PCS-Quick Release
• Always store the PCS-Quick Release for longer
periods of time without a tip attached.
• If the PCS is locked without the tip inserted,
pull back the collar and push the tip in as usual.
• Always keep the PCS dry and clean.
• Clean PCS with compressed air or distilled
water only.
• Do not open the PCS-Quick Release itself.
The warranty becomes void if the PCS has been opened.
• When working close to the sea, a small drop
of silicon grease on the tip of the thread of the two locking screws can help prevent the natural process of galvanic corrosion between the aluminium base and the steel screws.
• If working near to the sea, at the end of each
working day it is recommended to clean the PCS, together with the rest of your mechanical equipment, with plenty of distilled water.
Page 15
• PCS is tested to withstand the equivalent
wear of 10+ years of normal use. However, the mechanism relies heavily on the PCS tip being in good condition/order. If your PCS doesn’t work as smoothly as it should, please check the condition of the tip, and replace it if required.
IMPORTANT:
PCS-Boom Connector (RYC185801) PCS-Spigot (RYC185803) PCS-Utility (RYC185804) PCS-Utility Half Coupler Kit Small PCS-Utility Half Coupler Kit Large
Tested operating temperature - 20°C to +70°C
• Max load 10kg (in xed position).
PCS-Organizer (RYC185800) PCS-Lite 3/8” (RYC185802) PCS-Lite 5/8” (RYC185812)
Tested operating temperature - 10°C to +50°C
• Max load 1kg (in xed position).
(RYC185809)
(RYC185810)
Page 16
Rycote Microphone Windshields Ltd
Libby’s Drive, Slad Road, Stroud,
Gloucestershire, GL5 1RN, UK
Tel: +44 (0) 1453 759338
Email: rycote.tech_support@vitecgroup.com
www.rycote.com
Cod. RI000015 10/20