Ruud PH2R40-40F, PH2R50-40F, P2-30F, P40-36F1, P2-40F1 Specification Sheet

...
Page 1
E
G
BA
C
F
H
HOT
WATER
CONNECTION
H
COLD
WATER
CONNECTION
D
1/2"
3/4" N.P.T.
RELIEF 
VALVE
OPENING
FLUE
ANODE ROD
Pacemaker
®
Get
4 MORE YEARS
with ProtectionPlus
®
Gas Water Heaters
Available in 29, 38, 40 and 50 Gallon Tall – 30, 40 and 50 Gallon Short Gas Models
6-Year Limited Tank and Parts Warranty*
With ProtectionPlus™the 6-Year Limited Tank Warranty Becomes 10 Years!
Guardian System
One-of-a-kind air/fuel shut-off device offers double
• protection Maintenance free – no filter to clean
tandard replacement parts
S
Environmentally Friendly Burner
Low NOx design for low nitrous oxide emissions
Self-Cleaning
EverKleen™patented system fights sediment build-up
• Reduces fuel costs
• Provides more hot water
Easy to Light
No matches required
Energy Efficient
More hot water at low operating cost
Longer Life
Patented magnesium anode rod design incorporates a
• special resistor that protects the tank from rust
High Altitude Compliant
All models are certified for applications up to 6,000
• feet above sea level. Some models are certified up to 10,200 feet above sea level. Check factory for listings
lus…
P
Brass drain valve and temperature and pressure relief
• valve are included Meets or exceeds National Appliance Energy
• Conservation Act (NAECA) requirements
H
High Efficiency Models Feature:
E
High performance and lower operating cost
Compliant with many gas utility incentive programs
*See Residential Warranty Information Brochure
for complete warranty information.
Energy Factor and Average Annual Operating Costs based on D.O.E.(Department of Energy) test procedures. D.O.E. national average fuel rate
atural gas $1.218/therm; LP $1.87/gallon
n
.
DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFO.
T Y
GAL. THOUS. BTU/HR. G.P.H. 90° RISE DEL. G.P.H. VENT HT. DIAM. CONN. SIZE CNTR. T&P CONN. WT. FACTOR OPER. COST
P E
CAP. MODEL NUMBER NAT. LP NAT. LP NAT. ABCDEF G H(LBS) NAT. NAT.
0 PH2R40-40F 40 34 40.4 34.3 68 63-1/4 59-3/4 21 14-1/2 3853-1/2 3/4 135 0.62 $294
H E
4
TALL
50 PH2R50-40F 40 36 40.4 36.4 83 62-1/4 58-3/4 23 14-1/2 3852-1/2 3/4 165 0.62 $294 29 P2-30F 32 30 32.3 30.3 50 59-3/4 56-3/8 16-1/8 14-1/2 3850-3/4 3/4 100 0.62 $294 40 P40-36F1 36 36.4 67 61-1/2 58 17-3/4 14-1/2 3853 3/4 120 0.59 $309 40 P2-40F1 38 32 38.4 32.3 73 61-3/4 58-3/8 18-1/8 14-1/2 3852-1/4 3/4 120 0.59 $309
T A
38 PH2-40F 40 34 40.4 34.3 68 61-1/2 57-3/4 19-3/4 14-1/2 3852-1/4 3/4 125 0.60 $304
L L
50 P2-50F1 38 36 38.4 36.4 90 61-1/2 58-1/4 20-1/8 14-1/2 3851-3/8 3/4 130 0.58 $315 50 PH2-50-40F 40 36 40.4 36.4 83 61-1/2 58 21-3/4 14-1/2 3852-1/2 3/4 150 0.58 $315 50 PH2-50-50F 50 50.5 83 62 58 21-3/4 14-1/2 4852-1/2 3/4 150 0.58 $315 30 P2-30S-30F 30 30.3 50 49-3/4 46-1/4 19-3/4 14-1/2 3840-1/4 3/4 98 0.61 $299
S H
40 P2-40SF 36 34 36.4 34.3 72 52-3/4 49-3/8 20-1/8 14-1/2 3842-3/4 3/4 130 0.59 $309
O
40 PH2-40SF 40 36 40.4 36.4 72 53-7/8 50-1/2 20-1/8 14-1/2 3844 3/4 130 0.59 $309
R T
50 PH50SF 40 36 40.4 36.4 84 54-1/4 49-3/4 22-1/4 14-1/2 3844 3/4 158 0.59 $309
SPECIFY LP GAS WHEN ORDERING. Add “P” suffix to the model number. Example: PH2R40-40PF.
• For SCAQMD rule 1121 compliance models (California only), add “SQ” suffix to the model number. Example: PH2R40-40FSQ.
AS INPUT IN RECOVERY IN FIRST HOUR HT.TO TANK GAS VENT CONN. SIDE WATER SHIP. ENERGY AVG. ANN.
G
HT.TO WATER HT.TO
Ruud Guardian System Features…
Exclusive Combustion Shut-off System
Should a spill incident occur, the Guardian System shuts off the gas supply and the air supply preventing a sustained vapor burn in the combustion chamber.
These units are designed to meet or exceed ANSI (American National Standards Institute) requirements and have been tested according to D.O.E. test procedures and meet or exceed the energy efficiency requirements of NAECA, ASHRAE standard 90, ICC Code and all state energy efficiency performance criteria for energy consuming appliances.
Before purchasing this appliance, read important energy cost and efficiency information available from your supplier.
In keeping with its policy of continuous progress and product improvement, Ruud reserves the right to make changes without notice .
Ruud Water Heating • 101 Bell Road, Montgomery, Alabama 36117-4305 • www.ruud.com
P R I N T E D I N U . S. A 0 7 / 0 8 WP F O R M N O. 1 0 1 R - 6 R e v. 1 1
Flame Arrestor Plate
A specially-designed flame arrestor prevents ignition of vapors outside the combustion chamber.
Y E A R L I M I T E D
TANK WARR ANTY
B E C O M E S
6
For more details, see form 101-7.
Maintenance Free
Superior air filtration prevents the flame arrestor from becoming clogged by lint, dust and oil.
10
Loading...