Installation
Locate the Encoder with the remote source. Install CAT-5
or CAT-5e cable between the remote source location and
the system controller, up to 300 feet (90 m).
Crimp an RJ-45 connector on the source end of the CAT5 cable, following the T568A standard as shown. Plug
the connector into the RNET A/V jack on the Encoder. (If
desired, use modular wall plates and RJ-45 patch cables
for a neater appearance. Punch down the CAT-5 per the
T568A standard and use a straight-through patch cable
between the Encoder and the wall plate.)
RJ-45 Using T568A
Wiring Standard
Setup for RNET Control
Note: For RNET control of the remote source, both the
source equipment and the system controller must be
RNET capable. If the RNET controller does not have an
RNET A/V jack, you will need to use an RAVD1 Decoder
at the controller to receive signals from the Encoder.
1. Connect RNET source equipment. Using the supplied RJ-45 patch cable, connect from an RNET Link jack
on the source equipment to the RNET Link jack on the
Encoder. Use the supplied RCA patch cable to connect
from the source equipment’s audio and video outputs to
the Encoder’s inputs.
2. Connect Encoder to RNET system. Crimp an RJ-45
connector on the system end of the CAT-5 cable, following the T568A standard as shown. With the RNET system
turned off, plug the connector into the RNET A/V source
input jack on the RNET system controller or RAVD1
Decoder. (If using a wall plate, punch down the CAT-5 per
the T568A standard and use a straight-through patch
cable between the system and the wall plate.)
Note: Do not plug the CAT-5 cable into an RNET Link
jack. It must be plugged into an RNET A/V jack on
either the system controller or the RAVD1 Decoder.
3. Connect Decoder to RNET system. If using an
RAVD1 Decoder, use a straight-through RJ-45 patch
cable to connect from either RNET Link jack on the
Decoder to any unused RNET Link jack on the system or
an RNET source component. Use RCA patch cables to
connect from the Decoder’s audio and video outputs to
inputs on the RNET system controller.
Note: Do not connect the Decoder’s IR input. Doing so
will disable RNET for the entire system.
Setup for IR Control
Note: If the system controller does not have an RNET
A/V jack, you will need to use an RAVD1 Decoder at
the controller to receive signals from the Encoder.
1. Connect source equipment. Attach an IR emitter
to the infrared sensor on the source equipment and plug
the emitter into the IR OUT jack on the Encoder. (Or use
an IR link cable or mono patch cable with 1/8-inch [3.5
mm] TS connectors to connect from the Encoder to the
source equipment’s IR input jack.) Use the supplied RCA
patch cable to connect from the source equipment’s
audio and video outputs to the Encoder’s inputs.
2. Connect Encoder to multiroom system. Crimp an
RJ-45 connector on the system end of the CAT-5 cable,
following the T568A standard as shown. With the system
turned off, plug the connector into the RNET A/V jack on
the system controller or RAVD1 Decoder. (If using a wall
plate, punch down the CAT-5 per the T568A standard
and use a straight-through patch cable between the
system and the wall plate.)
Note: Do not plug the CAT-5 cable into an RNET Link
jack. It must be plugged into an RNET A/V jack on
either the system controller or the RAVD1 Decoder.
3. Connect Decoder to system. If using an RAVD1
Decoder, use RCA patch cables to connect from the
Decoder’s outputs to source inputs on the system.
RNET system. Use a straight-through RJ-45 patch cable
to connect from either RNET Link jack on the Decoder
to any unused RNET Link jack on the system or an RNET
source component.
Note: Do not connect the Decoder’s IR input. Doing so
will disable RNET for the entire system.
Non-RNET system. Use an IR link cable or mono patch
cable with 1/8-inch (3.5 mm) TS connectors to connect
from the system’s IR output to the Decoder’s IR input.
Final Steps
1. Power Encoder. Plug the power supply into an AC
power receptacle and connect its output lead to the
power jack on the Encoder. If using an RAVD1 Decoder,
power it up as well.
2. Turn on source and system. Power up the remote
source and the system. Select the remote source at a
system keypad or touchscreen and begin playing the
source. You should hear it playing through the system.
3. Program multiroom system. Follow the multiroom
system’s programming instructions to set up the remote
source for control from the keypads and touchscreens.
Specifi cations
RNET A/V connector: 8-pole modular RJ-45 jack
Input connectors: (1) composite video RCA jack
(2) left and right audio RCA jacks
IR emitter connector: 2-pole 0.125” (3.5 mm) TS jack
RNET Link connector: 8-pole modular RJ-45 jack
Power requirement: 12 VDC 1 A (power supply included)
Mounting method: Surface
Dimensions: 4.25” W x 1.82” H x 2.5” D
(10.8 x 4.6 x 6.4 cm)
Weight: 10.0 oz (284 g)
Warranty
The Russound RAVE1 is fully guaranteed against all defects in materials
and workmanship for two (2) years from the date of purchase. During this
period, Russound will replace any defective parts and correct any defect in
workmanship without charge for either parts or labor. For this warranty to
apply, the unit must be installed and used according to its written instructions. If service is necessary, it must be performed by Russound. The
unit must be returned to Russound at the owner’s expense and with prior
written permission. Accidental damage and shipping damage are not considered defects, nor is damage resulting from abuse or from servicing by
an agency or person not specifi cally authorized in writing by Russound.
This warranty does not cover: damage caused by abuse, accident, misuse, negligence, or improper installation or operation; power surges and
lightning strikes; normal wear and maintenance; products that have been
altered or modifi ed; any product whose identifying number, decal, serial
number, etc. has been altered, defaced or removed.
Russound sells products only through authorized dealers and distributors
to ensure that customers obtain proper support and service. Any Russound product purchased from an unauthorized dealer or other source,
including retailers, mail order sellers and online sellers will not be honored
or serviced under existing Russound warranty policy. Any sale of products
by an unauthorized source or other manner not authorized by Russound
shall void the warranty on the applicable product.
Damage to or destruction of components due to application of excessive
power voids the warranty on those parts. In these cases, repairs will be
made on the basis or the retail value of the parts and labor. To return for
repairs, the unit must be shipped to Russound at the owner’s expense,
along with a note explaining the nature of service required. Be sure to pack
the unit in a corrugated container with at least three (3) inches of resilient
material to protect the unit from damage in transit.
Before returning a unit for repair, call Russound at 603.659.5170 for a
return authorization number. Write this number on the shipping label and
ship to: Russound, 5 Forbes Road, Newmarket, NH 03857.
5 Forbes Road, Newmarket NH 03857 USA
Tel 603.659.5170 • Fax 603.659.5388
www.russound.com
Copyright © 2007 Russound. All rights reserved. All trademarks are the
property of their respective owners. Specifi cations are subject to change
without notice. Russound is not responsible for typographical errors or
omissions. 28-1264 06/05/07
RAVE1
RNET A/V Encoder
Instruction Manual
Overview
The RAVE1 RNET A/V Encoder enables the use of a remote source with a Russound RNET® or other multiroom
audio-video system. It connects to the source equipment
and sends audio and video signals to the multiroom
system over a single CAT-5 cable. It also provides either
RNET or infrared control of the source equipment.
Housed in a compact surface-mount metal box, the
RAVE1 provides connectors for RNET Link, IR emitter,
stereo audio, and composite video. A special RJ-45 jack
connects through the CAT-5 cable to either an RAVD1
RNET A/V Decoder or an RNET A/V-enabled multiroom
controller at the system end.
The RAVE1 comes with a 12 VDC power supply and
patch cables for connecting to the source equipment.
Features
• Enables remote location of an audio-video source for a
multiroom system
• Provides RNET control and feedback with an RNET
remote source and multiroom system
• Provides IR control of a non-RNET remote source
• Connects to the multiroom system with a single CAT-5
cable
• Easily mounts on any fl at surface
Safety Precautions
1. Read these instructions.
Typical Applications
Front and Rear Panels
CAV6.6 Multiroom Controller
2. Keep these instructions
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus
(including amplifi ers) that produce heat.
9. Do not defeat the safety purpose of the polarized or
grounding plug. A polarized plug has two blades with
one wider than the other. A grounding plug has two
blades and a third grounding prong. The wide blade
or the third prong is provided for your safety. If the
provided plug does not fi t into your outlet, consult an
electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or
pinched, particularly at plugs, convenience receptacles, and the point where it exits from the apparatus.
11. Use only attachments or accessories specifi ed by
the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or
table specifi ed by the manufacturer or sold with the
apparatus. When a cart is used, use caution when
moving the cart-apparatus combination to avoid
injury from tip-over.
13. Unplug this apparatus during lightning storms or
when unused for long periods of time.
14. Refer all servicing to qualifi ed service personnel. Servicing is required when the apparatus has been damaged in any way, such as the power supply cord or
plug is damaged, liquid has been spilled or objects
have fallen into the apparatus, or the apparatus has
been exposed to rain or moisture, does not operate
normally, or has been dropped.
If you have any questions, call Russound at
800.638.8055 or 603.659.5170.
SMS3 Smart Media Server
RJ-45 Patch Cable
Satellite Receiver
A/V OUT
IR
VLR
IR
VLR
RCA Patch Cable
IR Link Cable
RCA Patch Cable
RCA Patch Cable
A/V OUT
RNET A/V Encoder
RNET A/V Encoder
Connections for RNET control of source
CAT-5 Cable
(up to 300 feet)
RJ-45 Wall Plates (optional)
CAV6.6 Multiroom Controller
CAT-5 Cable
(up to 300 feet)
RJ-45 Wall Plates (optional)
Connections for IR control of source
RJ-45 Patch Cable
RJ-45 Patch Cable
IR Link Cable
RCA Patch Cable
RCA Patch Cable
1
2 3 4 5
RNET A/V PORT – For connection to RNET A/V port
1
on multiroom controller or RAVD1 Decoder
2
AUDIO-VIDEO INPUTS – For connection to remote
source outputs
IR OUTPUT – For connecting an infrared emitter for
3
IR control of remote source
4
POWER INPUT – For connecting included 12 VDC
1 A power supply
5
RNET LINK PORT – For connecting to an RNET
source component for RNET control and feedback
Note: The RAVE1 provides either RNET or IR
control of the source. Both control methods
cannot be used at the same time.