Russound DPA-4.8 User Manual

4-Zone / 8-Channel Amplifier
DPA-4.8
Instruction Manual
DPA-4.8 manual 11/1/02 4:14 PM Page 1
POWER
1234
ONE
Z
4 ZONE — 8 CHANNEL AMPLIFIER
DPA-4.8
WARNINGS
“WARNING” “ TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE
THIS APPLIANCE TO RAIN OR MOISTURE.”
“CAUTION” “ TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER. NO USER - SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
The lightning flash with arrowhead symbol, within an equilateral trian­gle, is intended to alert the user to the presence of uninsulated “dan­gerous voltage” within the products enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
Double Insulated, when servicing use only identical replacement parts
SAFETY INSTRUCTIONS
1. Read Instructions - All the safety and operating instructions should be read before the appliance is operated.
2. Retain Instructions - The safety and operating instructions should be retained for future reference.
3. Heed Warnings - All warnings on the appliance in the operating instructions should be adhered to.
4. Follow Instructions - All operating and user instructions should be followed.
5. Water and Moisture - The appliance should not be used near water - for exam­ple, near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool, and the like.
6. Carts and Stands - The appliance should be used only with a cart or stand that is recommended by the manufacturer. An appliance and cart combination should be moved with care. Quick stops, excessive force and uneven surfaces may cause the appliance and cart combination to overturn.
7. Wall or ceiling Mounting - The appliance should be mounted to a wall or ceiling only as recommended by the manufacturer.
8. Ventilation - The appliance should be situated so that its location or position does not interfere with its proper ventilation. For example, the appliance should not be situated on a bed, sofa, rug, or similar surface that may block the ventila­tion openings or, placed in a built - in installation, such as a bookcase or cabinet that may impede the flow of air through the ventilation openings. Place the DPA-4.8 in a well-ventilated location, leaving at least 2 inches (5cm) of clear­ance on all sides, top and rear of unit for air flow. If ventilation is blocked, the DPA-4.8 may overheat and malfunction.
9. Heat - The appliance should be situated away from heat sources such as radia­tors, heat registers, stoves, or other appliances ( including amplifiers ) that pro­duce heat.
10.Power Sources - The appliance should be connected to a power supply only of the type described in the operating instructions or as marked on the appliance.
11 .Grounding or Polarization - The precautions that should be taken so that the
grounding or polarization means of an appliance is not defeated .
12. Power - Cord Protection - Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords at plugs, receptacles, and the point where they exit from the appliance.
13. Cleaning - The appliance should be cleaned only as recommended by the manu­facturer.
14. Non-use Periods - The power cord of the appliance should be unplugged from the outlet when left unused for a long period of time.
15. Object and Liquid Entry - Care should be taken so that objects do not fall and liquids are not spilled into the enclosure through the openings.
16. Damage Requiring Service - The appliance should be serviced by qualified serv­ice personnel when:
A. The power - supply cord or the plug has been damaged; or B. Objects have fallen, or liquid has been spilled into the appliance; or C. The appliance has been exposed to rain; or D. The appliance does not appear to operate normally; or E. The appliance has been dropped or the enclosure is damaged.
17. Servicing - The user should not attempt to service the appliance beyond that described in the operating instructions. All other servicing should be referred to qualified service personnel.
18. Avoid using a telephone (other than cordless type) during an electrical storm. There may be a remote risk of electric shock from lightning.
19. Do not use the telephone to report a gas leak near the leak.
20. The apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases, shall be placed on the apparatus.
PRECAUTIONS
1. Do Not Touch The DPA-4.8 With Wet Hands. Do not handle the DPA-4.8 or power cord when your hands are wet or damp. If water or any other liquid enters the DPA-4.8 cabinet, take the DPA-4.8 to qualified service personal for inspection.
2. Location of the DPA-4.8 - Do not expose the DPA-4.8 to direct sun light or heating units as the DPA-4.8 internal components temperature may rise and shorten the life of the components. Avoid damp and dusty places.
3. Care – From time to time you should wipe off the front and side panels and the cabinet with a soft cloth. Do not use rough material, thinners, alcohol or other chemical solvents or cloths since this may damage the finish or remove the panel lettering.
CONTENTS
Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Possible System Configuration . . . . . . . . . . . . . . . . . . . . . . . . .4
Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Back Panel Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Bridged Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
2
Conforms to
ANSI/UL 6500
Certified to
CSA C22.2
No1-94
DPA-4.8
DPA-4.8 manual 11/1/02 4:14 PM Page 2
Russound
Tested to Comply
with FCC Standards
FOR HOME OR OFFICE USE
INTRODUCTION
Congratulations on your recent purchase of the Russound DPA-4.8 8-channel amplifier. The DPA-4.8 high-current, high­quality amplifier is the heart of the home theater or multi­zone system. The DPA-4.8 8-channel amplifier is capable of amplifying four stereo line level sources (CD players, tape decks, preamplifiers, tuners, etc.) simultaneously in multi-zone, multi-source installations. The eight amplifiers are arranged in pairs to provide four stereo amplifiers. With separate gain controls for each channel, sound levels can be preset to accommodate most rooms. The Main Bus Input allows for two or more stereo amplifiers to share the same audio source. With the stereo/mono selector in the mono position, two amplifiers can serve as mono outputs. In the mono position
the four stereo pairs can be bridged to two stereo pairs for higher output power. The DPA-4.8 power output is 50 watts per channel into 8 ohms, and 75 watts into 4-ohms. Bridged adjacent outputs provide 100 watts of power into 8-ohms and 150 watts of power into 4-ohms. All this power is backed by two high output toroidal transformers. Each amplifier out­put channel incorporates thermal, short circuit protection and Russound’s unique Dynamic Clipping Sensor that allows for better headroom and volume without clipping or distortion that is normally heard in most amplifiers.
The Russound DPA-4.8 amplifier is built with pride. Fidelity, reliability and quality are the primary objective. Russound products are guaranteed to provide years of enjoyment.
3
DPA-4.8 manual 11/1/02 4:14 PM Page 3
POWER
POWER
4 ZONE — 8 CHANNEL AMPLIFIER
1234
ONE
Z
DPA-4.8
+ L
– L
– R
+ R
R
LINE
BUS
SPEAKERS
MAIN BUS
R
L
3
ZONE 4
L
L
GAIN
R
4
MUTING
DELAY TIME
INE
L
INPUT
STEREO
BRGD MONO
MAIN BUS
R
*
OUTPUT
L
NEWMARKET, NH USA
DESIGNED IN THE USA MADE IN TAIWAN
+ L
– L
– R
+ R
R
LINE
BUS
SPEAKERS
DPA-4.8
3
2
1
ZONE 3
L
L
GAIN
R
4
MUTING
DELAY TIME
INE
L
INPUT
STEREO
BRGD MONO
*
MINIMUM LOAD IMPEDANCE: 4 OHM
* SEE MANUAL FOR BRIDGED MONO OPERATION INSTRUCTIONS
R
LINE
BUS
+ L
– L
2
– R
1
+ R
SPEAKERS
3
ZONE 2
L
L
GAIN
R
4
MUTING
DELAY TIME
INE
L
INPUT
STEREO
BRGD MONO
SERIAL #
ZONE 1
WARNING : SHOCK HAZARD
O NOT OPEN
D
L
R
LINE
BUS
+
*
L –
3
L
2
– R
1
+ R
SPEAKERS
L
GAIN
R
4
MUTING
DELAY TIME
INE
L
INPUT
STEREO
BRGD MONO
AVIS : RISQUE DE CHOC ELECTRIQUE – NES PAS OUVRIR.
Russound
DPA-4.8
Tested to
Comply with
FCC Standards
FOR HOME OR OFFICE USE
Conforms to ANSI/UL 6500
Certified to
CAN/CSA
*
E65-94
Double Insulation - When servicing use
~120VAC ~60Hz 5A
only identical replacement parts
INPUT
2
1
Loading...