5 Forbes Rd. Newmarket, NH 03857, USA
Tel 603.659.5170 • Fax 603.659.5388
e-mail: tech@russound.com
PRODUCT OVERVIEW
The SaphIR 860P Phantom Plasma receives IR signals from a handheld IR remote control and relays these signals to the audio-video
equipment for operation from another room. It mounts to a flat
surface with two-sided tape (included).
FEATURES
• Plasma-friendly - can be placed near plasma TV and displays
• CFL friendly - allows installations in areas with compact
fluorescent lighting. Works in most lighting environments.
• Blue IR confirmation LED
• Wide band IR - receives IR from many types of remotes
• Available in black or silver
INSTALLATION
Place the SaphIR 860P Phantom on a shelf or other flat surface with
the IR receiver facing out. Use the included double-sided tape to
secure it to the surface.
28-1209 09/27/05
SaphIR
860P Phantom
Mini Infrared Receiver
CFL Friendly
Instruction Manual
WIRE CONNECTIONS
Direct Connection from 860P Phantom to Connecting Block
Connect the 860P Phantom to the 857 connecting block. Connect
GND (GROUND), IR (SIGNAL) and Voltage (+12VDC) to connector on
the 857.
LIMITED WARRANTY
The Russound 860P Phantom is fully guaranteed for two (2) years from the date of
purchase against all defects in materials and workmanship. For this warranty to apply,
the unit must be installed and used according to its written instructions. During this
period, Russound will replace any defective parts or correct any defect in workmanship
without charge for either parts or labor. Accidental damage and shipping damage are
not considered defects under the terms of this warranty. Russound assumes no
responsibility for defects resulting from abuse or servicing performed by an agency or
person not specifically authorized in writing by Russound. If service is necessary, it
must be performed by Russound. Damage to or destruction of components due to
excessive power voids the warranty. In these cases, the repair will be made at the
owner’s expense. To return for repairs, the unit must be shipped to Russound at the
owner’s expense, along with a note explaining the nature of the service required. Be
sure to pack in a corrugated container with at least 3 inches of resilient material to protect the unit from damage in transit.
Before returning a unit for repair, call Russound at (603) 659-5170 for a Return
Authorization number. Write the RA number on the shipping label and ship to:
Russound, ATTN: Service, 5 Forbes Road, Newmarket NH 03857
Russound sells product only through authorized Dealers and Distributors to ensure that
customers obtain proper support and service. Any Russound product purchased from
an unauthorized dealer or other source, including retailers, mail order sellers and online
sellers will not be honored or serviced under existing Russound warranty policy. Any
sale of products by an unauthorized source or other manner not authorized by
Russound shall void the warranty on the applicable product.
CONNECT TO
846C OR 1201A
POWER
SUPPLY
12 VDC
SIGNAL (White)
+12VDC (Black)
GND (Black)
S
TATU S
+
12VDC
P
OWER
+
12VDC
IR R
ECEIVER IN
IR C
OMMON IN
+
12VDC
GND
STATUS
SIGNAL
DESIGNED IN USA MADE IN CHINA
C
ONNECTING
857 I
NFRARED
B
LOCK
IR C
E
MITTERS
ONFIRM
857
CONNECTING
BLOCK
123456
EMITTER PORTS
PACKAGE INCLUDES:
SaphIR 860P Phantom IR Receiver (1)
Terminal Strip (1)
Screws (2)
Two-way Mounting Tape (1)
WIRE CONNECTIONS
Extended Leads from 860P Phantom to Terminal Strip to Connecting
Block
The extended connection between the IR receiver and the connecting
block should be made with twisted-pair wiring (i.e., CAT-5e cable). It may
be necessary to use shielded twisted-pair wiring if the wiring is exposed
to interference from power wiring centers or from broadcast signals
(FM, TV, etc.) located nearby. The installer should determine the cable
type needed to suit the local conditions of the installation. A terminal strip
is included for extending the leads.
Russound offers both CAT-5e cable (AWCAT5) and shielded twisted-pair
cable (AW2260AB) which are suitable for IR installations. Contact Russound
for ordering information.
860P CAT-5e 857
SIGNAL BL SIGNAL
+12VDC GR/GRW +12VDC
GND BR/BRW GND
OR/ORW GND
BLW GND
SPECIFICATIONS
Receive Frequency Range: 36kHz to 58kHz
Transmit Frequencies: 40kHz and 56kHz
Range: On Axis - 30ft to 50ft (9.1-15.2m)
30º Off Axis - 5ft to 15ft (1.5-4.6m)
Power: 12VDC 31mA max
Dimensions: 2.09”W x 0.47”H x 0.5”D
(53.1 x 11.9 x 12.7mm)
Mounting Cord Length: 78.74” (200cm)
Finishes: Black, Silver
SIGNAL
(White)
GND
(Black)
860P Phantom
+12VDC
(Black)
Terminal
Blue/White
Strip
Open
Blue
Blue/White
Green
Green/White
Brown
Brown/White
Orange Pair
Open
CAT-5e cable
CONNECT TO
846C OR 1201A
POWER
SUPPLY
Green/White
Brown
Brown/White
Orange
Orange/White
Blue
12 VDC
S
TATUS
+
12VDC
P
OWER
+
Green
12VDC
IR R
ECEIVER IN
IR C
OMMON IN
+
12VDC
GND
STATUS
SIGNAL
DESIGNED IN USA MADE IN CHINA
Drain Orange Pair
and Blue/White to
GND on 857
C
ONNECTING
B
LOCK
IR C
ONFIRM
CONNECTING
123456
857 I
NFRARED
E
MITTERS
857
BLOCK