DIMENSIONS (IN)
MODEL
WE 17-12 WE 17-15
WE 17-18 WE 17-25 WE 17-35
WE 17-45
WE 18-55
A
12-3/4 12-3/4 15-3/4 18-3/4 21-3/4 24-3/4
24-3/4
B
13-5/8 13-5/8 13-5/8 14-5/8 15-5/8 15-5/8
15-5/8
C
15-13/16 15-13/16 15-13/16 16-13/16
17-7/8 20-1/2
20-1/2
D F
11-7/16 11-7/16
14-1/2 17-1/2 20-1/2 23-5/8
23-5/8
1-1/4 1-1/4 1-1/4 1-1/4 1-1/4 1-7/8
1-7/8
8-5/16 8-5/16 8-5/16 8-5/16
Wedge - Temp
IOM 115
H
9-1/2 9-5/8
9-5/8
W
15-1/4 15-1/4 17-3/4 19-7/8 22-7/8 26-3/4
26-3/4
Liquid Conn.
1/2 FN 1/2 FN 1/2 FN 1/2 FN
1/2 FN 1/2 FN
1/2 FN
Suction
Conn.
1/2 OD 1/2 OD 1/2 OD 1/2 OD
1/2 OD 1/2 OD 1/2 OD
W
(lbs.)
eight
16 19 22 29
36 57 65
GENERAL
RECEIPT AND EXAMINATION
Carefully check all items against bill of lading to be sure everything has been received as ordered. Carefully inspect all items for damage and, if any is found, report it immediately to the carrier and file damage claim with same.
LOCATION AND MOUNTING
The WE is designed to mount on ceiling only. The unit should be installed so that there are no restrictions on the air inlet or outlet as this will cause the refrigeration system to operate less ef
Remove the unit from the carton. Using the fastener holes in the unit as a guide, locate the mounting fasteners in the ceiling of the walk-in or reach-in cooler. Use #10 screws or 1/4” diameter bolts to secure the unit to the ceiling. This unit must be installed so as to allow drainage of condensate coming off the coil.
The National Sanitation Foundation (NSF) requires that any flush mounted unit be properly and completely sealed, with an approved NSF sealant, between the unit and the mounting surface.
ELECTRICAL
System electrical installation should conform to all applicable codes and practices. according to the nameplate motor circuit electrical ratings.
REPLACEMENT PARTS
o order replacement parts, contact your local representative or contact the factory (800) 288-9488 for the location of the nearest HTP
T Always provide the evaporator model number, serial number, unit voltage and a complete description of the part required.
Coil
Model
Number
WE 17-12 WE 17-15 WE 17-18 WE 17-25 WE 17-35 WE 17-45 WE 18-55
MOT
FAN MOTOR
OR
HP
4 Watt 9 Watt 9 Watt 9 Watt
16 Watt
1/20 1/20
MOT
RPM
1550 1550 1550 1550 1550 1550 1550
OR
ficiently.
NUMBER
102104002 103104004 103104004 103104004 103104007 102540001 102540001
All models will require the connection of power to the fan motor
wholesaler
BLADE
AN
P
BORE DESCRIPTION
1/4” 1/4” 1/4”
Hubless
1/4” 5/16 5/16
831 CCW 831 CCW
831 CCW 1020 CCW 1031 CCW 1219 CCW 1219 CCW
T
F
AR
T
AR
P
NUMBER
204395010 204395010 204395010 204395016 204395018
11860 11860
FAN GUARD
DIA.
8” 8” 8”
8” 10” 12” 12”
PAR T
NUMBER
206569000 206569000 206569000 201006002 201006002 201006003 201006003
DRAIN PAN
Part No. #08499044
.
PAR T
NUMBER 20193200
20193200 20193000 20192600 20192400 20194000 20194000