INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS
Twin - Temp
IOM 111
MODEL
NUMBER
TW 17-9 TW 17-12 TW 17-18 TW 17-25 TW 17-35 TW 17-45
TW 17-55 TW 18-65
TW 17-75 TW 18-85
TW 17-105 TW 18-120
FIG.
1 1 1 1 1 1
1 1
2 2
2 2
A
18-1/2 18-1/2 18-1/2 20-1/2 20-1/2 30-1/2
30-1/2 30-1/2
35-1/4 35-1/4
35-1/4 35-1/4
DIMENSIONS (In)
B
16-1/2 16-1/2 16-1/2 18-1/2 18-1/2
7-5/8 7-5/8 9-1/8 9-5/8
11-1/4
21-1/4 21-1/4
21-1/4 36-1/4
36-1/4 36-1/4
36-1/4
C D
5-7/8 5-7/8 7-3/8 7-3/8
10
7-3/4
12
9-3/4
12
9-3/4
11
7-3/4
11
7-3/4
13
9-3/4
13
9-3/4
CONNECTION SIZE (In)
1/2 FN 1/2 FN 1/2 FN 1/2 FN 1/2 FN
1/2 OD 1/2 OD
1/2 OD 1/2 OD
1/2 OD 5/8 OD
5/8 OD
DRAIN
1/2 OD 1/2 OD 1/2 OD
1/2 OD 1/2 OD 1/2 FPT
1/2 FPT
1/2 FPT
1/2 FPT
1/2 FPT
1/2 FPT
1/2 FPT
E
12-1/2 12-1/2 12-1/2
15
9
15 17
17 17
31 31
31 31
F SUCTION INLET
19
1/2 MF
19
1/2 MF
19
1/2 MF
21
1/2 MF
21
1/2 MF
32
5/8 OD
32
5/8 OD
32
5/8 OD
36-1/2 36-1/2 36-1/2 36-1/2
5/8 OD 5/8 OD
7/8 OD 7/8 OD
SHIP
WT
(lbs)
17 19 23 26 28 44 50 55
109 115
121 128
.
GENERAL
RECEIPT AND EXAMINATION
Carefully check all items against bill of lading to be sure everything has been received as ordered. Carefully inspect all items for damage and, if any is found, report it immediately to the carrier and file damage claim with same.
INSTALLATION
LOCATION AND MOUNTING
The TW is designed to mount on the ceiling only. The unit should be installed so that there are no restrictions on the air inlet or outlet as this will cause the refrigeration system to operate less efficiently.
Remove the unit from the carton. Using the fastener holes in the unit as a guide, locate the mounting fasteners in the ceiling of the walk-in or reach-in freezer. Use #10 screws or 1/4” diameter bolts to secure the unit to the ceiling. The unit must be installed so as to allow drainage of condensate com­ing off the coil.
The National Sanitation Foundation (NSF) between the unit and the mounting surface.
requires that any flush mounted unit be properly and completely sealed, with an approved NSF
sealant,
ELECTRICAL
System electrical installation should conform to all applicable codes and practices. according to the nameplate motor circuit electrical ratings.
All models will require the connection of power to the fan motor
REPLACEMENT PARTS
o order replacement parts, contact your local representative or contact the factory (800) 288-9488 for the location of the nearest HTP
T
wholesaler
Always provide the evaporator model number, serial number, unit voltage and a complete description of the part required.
Coil
Model
MOTOR
Number
TW 17-9 TW 17-12 TW 17-18 TW 17-25 TW 17-35 TW 17-45 TW 17-55 TW 18-65 TW 17-75 TW 18-85 TW 17-105 TW 18-120
HP
4 Watt 4 Watt
att
9 W
att
9 W
16 Watt
1/20 1/20 1/20 1/12 1/12 1/12 1/12
F
AN MOTOR
MOTOR
RPM
1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550
PAR T
NUMBER
103104002 103104002 103104004 103104004 103104004 102540001 102540001 102540001 102540001 102540001 102540001 102540001
BORE DESCRIPTION
Hubless Hubless Hubless Hubless Hubless
5/16 5/16 5/16
1/2 1/2 1/2 1/2
FAN BLADE
820 CCW 820 CCW
831 CCW 1020 CCW 1020 CCW 1218 CCW 1219 CCW 1223 CCW 1616 CCW 1616 CCW 1616 CCW 1616 CCW
PAR T
NUMBER
204395008 204395008 204395010 204395016 204395016
18000
2141
1860
1 11882 11904
1904
1 11904 11904
DIA.
10” 10” 12” 12” 12” 16” 16” 16” 16”
GUARD
AN
F
DRAIN P
PAR T
NUMBER
8” 8” 8”
206569000 206569000 206569000 201006002 201006002 201006003 201006003 201006004 201006004 201006004 201006004 201006004
Part No. #08499041
.
AN
PAR T
NUMBER
208701 208701 208701 208735 208735 208746 208746 208746 105744 105744 105744 105744