INSTALLATION OPERATION
Slim - Temp
AND MAINTENANCE INSTRUCTIONS
DIMENSIONS (Inches)
MODEL
SLE15-9
SLE15-12
SLE15-16
SLE25-21
SLE25-28
SLE35-36
SLE45-54
SLE35-70
W
16-1/2
20-1/2
24
24
31-1/2
38-1/2
48-1/2
76-1/2
D
13-1/2
13-1/2
14-1/2
15-1/2
15-1/2
15-1/2
16-1/2
20-1/2
H
4-3/4
4-3/4
4-3/4
6-3/4
6-3/4
6-3/4
6-3/4
6-3/4
B C
6-3/4
6-3/4
6-3/4
8
7-3/4
7-3/4
8
7-3/4
2-1/4
2-1/4
2-1/4
2-1/4
2-1/4
2-1/4
2-1/4
2-1/4
E
13-3/4
13-3/4
14-3/4
15-3/4
15-3/4
15-3/4
16-3/4
20-3/4
FG
14-3/4
18-3/4
22-1/4
22-1/4
29-3/4
36-3/4
46-3/4
74-1/8
7/8
7/8
7/8
7/8
7/8
7/8
7/8
1-1/2
J
7/8
7/8
7/8
7/8
7/8
7/8
7/8
7/8
K
1
1
1
1
1
1
1
1
L N SUC. LIQ.M
2-3/4
3-3/433
11-3/4
6-1/433
5-3/432
13
8-1/2
IOM 109
CONNECTIONS
4-3/4
4-3/4
4-3/4
4-3/4
3-3/4
3-3/4
2
3-3/4
2
3-3/4
2
3/8
3/8
3/8
1/2
1/2
5/8
5/8
7/8
1/2 FN
1/2 FN
1/2 FN
1/2 FN
1/2 FN
1/2 FN
1/2 FN
1/2 FN
WT.
DRAIN
LBS.
1/2 OD
1/2 OD1619
1/2 OD
1/2 OD
1/2 OD
1/2 OD
1/2 OD
1/2 OD
23
31
39
48
70
105
GENERAL
RECEIPT AND EXAMINATION
Carefully check all items against bill of lading to be sure everything has been received as ordered. Carefully inspect all items for damage and, if any is found, report it immediatley to the carrier and file damage claim with same.
INSTALLATION
LOCATION AND MOUNTING
The SLE is designed to mount on the ceiling only. The unit should be installed so that there are no restrictions on the air inlet or outlet
as this will cause the refrigeration system to operate less efficiently.
Remove the unit from the carton. Using the fastner holes in the unit as a guide, locate the mounting fasteners in the ceiling of the
walk-in or reach-in freezer. Use #10 screws or 1/4” diameter bolts to secure the unit to the ceiling. The unit must be installed so as to
allow drainage of condensate coming off the coil.
The National Sanitation Foundation (NSF) requires that any flush mounted unit be properly and completely sealed, with an approved
NSF sealant, between the unit and the mounting surface.
ELECTRICAL
System electrical installation should conform to all applicable codes and practices.
the fan motor and heaters according to the nameplate motor and heater circuit electrical ratings.
REPLACEMENT PARTS
To order replacement parts, contact your local representative or contact the factory (800) 288-9488 for the location of the nearest HTP
wholesaler. Always provide the evaporator model number, serial number, unit voltage and a complete description of the part required.
FAN MOTOR 230V 115V FAN BLADE HEATER 230V 115V FAN GUARD
MODEL
SLE15-9
SLE15-12
SLE25-16
SLE25-21
SLE25-28
SLE35-36
SLE45-54
SLE35-70
MOTOR
43 WATT
43 WATT
43 WATT
9 WATT
9 WATT
9 WATT
9 WATT
16 WATT
HP
MOTOR
RPM
3000
3000
3000
1550
1550
1550
1550
1550
PAR T
NUMBER
102249007
102249007
102249007
103104005
103104005
103104005
103104005
103104008
PAR T
NUMBER
102249005
102249005
102249005
103104004
103104004
103104004
103104004
103104007
BORE DESCRIP
1/4”
621 CW
1/4”
621 CW
621 CW
1/4”
831 CCW
1/4”
1/4”
831 CCW
1/4”
831 CCW
831 CCW
1/4”
1031 CCW
1/4”
PAR T
NUMBER
105849001
105849001
105849001
204395010
204395010
204395010
204395010
204395018
All models will require the connection of power to
W
ATTS
400
500
700
700
900
1200
1500
2300
PAR T
NUMBER
220150031
220150032
220150033
220150033
220150034
220150035
220150036
220150037
PAR T
NUMBER
220150001
220150002
220150003
220150003
220150004
220150005
220150006
220150007
DIA.
6”
6”
6”
8”
8”
8”
8”
10”
PAR T
NUMBER
205932000
205932000
205932000
206569000
206569000
206569000
206569000
201006002
Part No. #08499040
DRAIN PAN
PAR T
NUMBER
20997400
20997600
20997800
20998000
20998200
20998400
20998600
20998800