SPECIFICATIONS
CAPACITY FLA FAN QTY CONNECTIONS(In) WT.
10°TD 12°TD 115V 230V DIA. MOTORS SUC. LIQ. DRAIN LBS
SLA17-10 1000 1200 150 0.73 0.37 6 1 3/8 ODS 1/2 FN. 1/2 OD 15
SLA17-13 1300 1560 180 0.73 0.37 6 1 3/8 ODS 1/2 FN. 1/2 OD 18
SLA27-17 1700 2040 300 1.5 0.75 6 2 3/8 ODS 1/2 FN. 1/2 OD 22
SLA27-23 2300 2760 350 1.5 0.75 6 2 1/2 ODS 1/2 FN. 1/2 OD 29
SLA37-30 3000 3600 500 2.2 1.1 6 3 1/2 ODS 1/2 FN. 1/2 OD 37
SLA47-40 4000 4800 600 2.9 1.5 6 4 1/2 ODS 1/2 FN. 1/2 OD 45
SLA57-50 5000 6000 750 3.7 1.9 6 5 1/2 ODS 1/2 FN. 1/2 OD 61
DIMENSIONS (Inches)
MODEL W D H B C E F G J K L M N
SLA17-10 16-1/2 13-1/2 4-3/4 6-3/4 2-1/4 13-3/4 14-3/4 7/8 7/8 1-1/16 2-3/4 3 4-3/4
SLA17-13 20-1/2 13-1/2 4-3/4 6-3/4 2-1/4 13-3/4 18-3/4 7/8 7/8 1-1/16 3-3/4 3 4-3/4
SLA27-17 24 14-1/2 4-3/4 6-3/4 2-1/4 14-3/4 22-1/4 7/8 7/8 1-1/16 11-3/4 3 4-3/4
SLA27-23 31-1/2 14-1/2 4-3/4 6-3/4 2-1/4 14-3/4 29-3/4 7/8 7/8 1-1/16 11-3/4 3 4-3/4
SLA37-30 40 14-1/2 4-3/4 6-3/4 2-1/4 14-3/4 38-1/4 7/8 7/8 1-1/16 6-3/4 3 4-3/4
SLA47-40 53-1/2 14-1/2 4-3/4 6-3/4 2-1/4 14-3/4 51-3/4 7/8 7/8 1-1/16 8-1/2 3 4-3/4
SLA57-50 53-1/2 14-1/2 6-3/4 6-3/4 2-1/4 14-3/4 51-3/4 7/8 7/8 1-1/16 5-1/4 4 5-3/4
Slim-Temp
7/8" K.O.
AIR FLOW
D
C
B
H
AIR FLOW
W N
F
K J
E
1-1/2" K.O.
7/8" K.O.
K
5/8"
L
M
G
P/N 113343-144 Rev.3 9/00 R-3000
MODEL
CFM
Reach-In
Unit Cooler
Air Defrost
Publication No. H112.0
September, 2000
The “SLA” product line offers 7 air defrost models. Typical installations include;
glass display and solid door upright coolers, walk-ins, salad cases, back bars
and other tight spaced enclosures operating above +34°F.
All models are very low in height. Built with heavy gauge, textured Aluminum,
they are compact and mount flush to the ceiling. Quick removal of the drain pan
allows easy access to electrical and piping components. Capacity ratings are
shown at +25°F evaporator temperature.
Our specially formulated epoxy coil coating is optionally available for all SLA
models. This durable, baked on fin coating is highly resistant to many corrosive
fumes and can significantly extend the life of the coil.
Due to continuing product development, specifications are subject to change without notice.