DUAL REFRIGERANT AIR COOLED CONDENSING UNITS
Description
Minicon R-series condensing units are ideally suited for use in a variety of commercial applications such as cafeterias, convenience stores, restaurants and fast food outlets. Minicon units offer a winning combination of quality, economy, and fl exibility coupled with lower long term operating costs.
This low profi le product line has been designed around environmentally safer refrigerants. Units are available with a choice of compressors: low cost hermetic, effi cient and quiet scroll compressors or heavy duty semi-hermetic and discus compressors.
In addition to the basic Indoor and Outdoor models described in this bulletin, Russell can also provide pre-engineered system packages with matching evaporators and accessories.
The standard R-series condensing unit is designed for operation in ambient air temperatures up to 110°F. Oversized condensers are available for most models. Contact our Applications Engineering department for requirements exceeding 110°F ambient temperature.
Features
Indoor/Outdoor Models (REH/RES/RED/REO)
• Hermetic, Semi-hermetic or Scroll compressor.
• Generously sized condenser, Copper tubes/ Aluminum fi ns
• Large electrical control panel for power and control circuits
• Compressor contactor or start kit
• Encapsulated high and low pressure controls (adjustable low pressure control on low temp models)
• Refrigerant receiver with shutoff valve and relief plug
• PSC motors are standard for all condenser fans
• All-weather housing
• UL and cUL listed for indoor or outdoor use
Optimized Packaged Units (RLH / RLS / RLD / RLO)
• Includes all Indoor model features - plus:
• Liquid line kit with fi lter/drier and sight glass with moisture indicator
• Suction line piping to exterior of cabinet
• Low Ambient - fl ooded head pressure control valve
• Crankcase heater
• Electric defrost timer with defrost contactor/relay on low temperature models (ED10-230/1)
• Air Defrost Timer (2-1/2 through 6 HP High and Medium temp models only, optional for other HP)
Options
• Factory installed air defrost timer
• Factory installed electric defrost timer with contactor
• Low ambient fl ooded control (STD on RL models)
• Mild ambient fan cycle control (for 2 fan units only)
• Suction line piping to exterior of cabinet (STD on RL models)
• Suction line kit with fi lter and piping
• Liquid line (piping only)
• Liquid line kit with piping, fi lter/ drier and sight glass (STD on RL models
• Suction accumulator
• Oil separator (not available with mounted accumulator)
• Crankcase heater
• Copper fi ns, or coated condenser coil
• Tiered stacking
• Liquid line solenoid
• Fused disconnect
• High ambient oversized condenser coil - contact Applications
• Spring mounting for semi-hermetic compressors
DUAL REFRIGERANT AIR COOLED CONDENSING UNITS
Features and Options
COMPRESSOR
ELECTRICAL
CONTROLS
CONDENSER
PIPING
COMPONENTS
RECEIVER
HOUSING
LOW AMBIENT
CONTROLS
DEFROST
PROVISIONS
TESTING
DESCRIPTION
Hermetic STD N/A N/A N/A STD N/A N/A N/A
Discus N/A STD N/A N/A N/A STD N/A N/A
Semi-Hermetic N/A N/A STD N/A N/A N/A STD N/A
Oil failure control (as required) N/R STD STD N/R N/R STD STD N/R
Encapsulated high and low pressure controls**
Compressor contactor (1Ø or 3Ø), start kit (1Ø)
Control transformer (460v to 230V) as required
Copper tubes, Aluminum fins
Fan motor(s) - overload protection
Fan blade(s) - individually balanced
Suction line ( vibrasorber
Suction kit (vibrasorber
Galvanized steel all weather housing
Fan cycle control (2 Fan models only)
Leak and dielectric tested before shipping
Dry Nitrogen shipping charge (25 to 35 PSI)
, piping and suction filter)
Suction line accumulator
Flooded head pressure control
Electric defrost package (1) (1) (1) (1)
Fan guard(s)
and piping only)
*Liquid line kit
Discharge vibrasober N/R STD†† STD†† N/R N/R STD†† STD†† N/R
Shut-off valve(s)
Fusible plug
Control panel
SIERRA
HIGH SIERRA
Air defrost time clock
UL and C-UL listed
PACKAGED UNITSSTANDARD UNITS
REH RED RES REO RLH RLD RLS RLO
Scroll N/A N/A N/A STD N/A N/A N/A STD
STANDARD STANDARD STANDARD STANDARD STANDARD STANDARD
OPTIONAL OPTIONAL OPTIONAL OPTIONAL OPTIONAL
STANDARD STANDARD
STANDARD STANDARD
See publication No. 506
See Publication No. 508
OPTIONAL OPTIONAL
OPTIONAL
OPTIONAL STANDARD STANDARD
STANDARD
STANDARD STANDARD STANDARD STANDARD STANDARD STANDARD
OPTIONAL
STANDARD
OPTIONAL OPTIONAL
STANDARD
STANDARD STANDARD
STANDARD
STANDARD NOT AVAILABLE NOT AVAILABLE
OPTIONAL
STANDARD
STD on 3-6 HP
STANDARD
STANDARD
STANDARD
STD = Standard Feature N/R = Not Required N/A = Not Available OPT = Optional Feature
† Vibrasorber not required for Hermetic and Scroll compressors. Vibrasorber not included for 1/2 through 2HP models. Add kit SPR-VB if suction vibrasorber required. ††Standard for 2-1/2 through 6HP Models. For 1/2 to 2HP models, add kit number SPR-VB to include vibrasorbers and compressor spring mounting. *Liquid line kit includes: piping, fi lter drier, sight glass/moisture indicator. ** Adjustable low pressure control on low temp models in lieu of fi xed control. (1) Electric defrost kit is included on Low temperature models. ED-10-230/1 for 1/2 to 3 HP models, and ED11-230/3 for 4 to 6 HP models.
MODEL NUMBER NOMENCLATURE
Voltage code
C=230/60/1 D= 208-230/60/1 E= 208-230/60/3 G= 460/60/3
215 = 2 HP 250 = 2 HP 251 = 2 HP 300 = 3 HP 301 = 3 HP 315 = 3 HP 400 = 4 HP 401 = 4 HP 500 = 5 HP 600 = 6 HP
Russell MiniCon R-Series
Model Style
E = Indoor/Outdoor Model L = Outdoor Flooded Model I= Sierra H = High Sierra
Compressor Type
S = Semi-Hermetic H = Hermetic D = Discus O = Scroll
R L D 500 M 44 —E
Refrigerant Type
22 = R22 44* = R404A / 507 * Some models can be used with R22 or R407C
Temperature Range (varies by unit)
H = High/Medium (0° to 45°F S.T.) M = Medium (-25° to 30° F S.T.) L = Low (-40° to 0° F S.T.)
Horsepower
055 = 1/2 HP 080 = 3/4 HP 090 = 1 HP 100 = 1 HP 125 = 1 HP 151 = 1-1/2 HP 165 = 1-1/2 HP 200 = 2 HP 201 = 2 HP 202 = 2 HP
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
090M4
4
9,5608,7007,8906,4205,1304,0303,1002,710
4
4
0
4
27,31,82,65,94,68,86,110
4
29,135,39,96,06,64,67,840
DUAL REFRIGERANT AIR COOLED CONDENSING UNITS
Capacity Data - High and Medium Temp Hermetic R404A Rating
R404A - HERMETIC - CAPACITY (BTUH)
HIGH TEMPERATURE - HERMETIC EXTENDED MEDIUM TEMPERATURE - HERMETIC
MODEL +40°F +35°F
R*H055H44
R*H090H44 R*H100H44
R*H151H44
R*H251H44
R*H325H44
9,250 8,340
12,920 11,760 14,140 12,760
22,000 19,710
27,160 24,500
44,290 39,740
90°F
AMBIENT
MODEL +30°F +25°F +20°F +10°F 0°F -10°F -20°F -25°F
R*H055M4 R*H080M4 R*H090M4
R*H R*H100M4
R*H100M R*H125M4
6,920 6,250 5,620 4,500 3,500 2,660 1,930 1,610
8,280 7,490 6,760 5,440 4,310 3,370 2,600 2,270
9,560 8,700 7,890 6,420 5,130 4,030 3,100 2,710
10,340 9,240 8,230 6,440 4,950 3,700 2,610 2,100
14,370 12,920 11,560 9,120 7,030 5,240 3,740 3,080
7
R*H151M44 17,920 15,900 14,000 10,630 7,820 5,510 3,620 2,820 R*H200M44 R*H251M44
19,470 17,420 15,510 12,030 9,040 6,550 4,520 3,680
21,560 19,290 17,190 13,420 10,220 7,550 5,380 4,450 R*H301M44 29,370 26,270 23,360 18,080 13,580 9,790 6,730 5,490 R*H325M44 32,160 28,800 25,620 19,910 15,090 11,060 7,710 6,260
51,320
44M005H*R096,45047,0644H005H*R
45,680 40,490 31,380 23,840 17,680 12,700 10,600
006,8053,01096,41042,02080,72053,53010,04080,5444M004H*R044,94079,4544H004H*R
MODEL
R*H055H44
R*H090H44 R*H100H44
R*H151H44
R*H251H44
R*H325H44
MODEL
R*H055H44
R*H090H44 R*H100H44
R*H151H44
R*H251H44
R*H325H44
+40°F +35°F
8,790 7,930
12,290 11,180 13,370 12,040
20,690 18,500
25,640 23,110
41,760 37,400
+40°F +35°F
8,330 7,510
11,650 10,590 12,590 11,330
19,380 17,290
24,130 21,720
39,230 35,070
95°F
AMBIENT
100°F
AMBIENT
MODEL
R*H055M4 R*H080M4 R*H090M4 R*H100M4 R*H125M4
+30°F +25°F +20°F +10°F 0°F -10°F
6,620 5,970 5,120 4,070 3,160 2,380 1,710 1,420
7,840 7,080 6,090 4,890 3,870 3,010 2,320 2,030
9,080 8,260 7,140 5,800 4,620 3,610 2,770 2,420
9,730 8,690 7,380 5,760 4,410 3,260 2,240 1,750
13,570 12,180 10,390 8,160 6,250 4,620 3,240 2,640
-20°F -25°F
R*H151M44 16,830 14,860 13,050 9,840 7,170 4,980 3,180 2,420 R*H200M44
R*H200M4
251M4
R*H251M44
,
18,270 16,310 13,820 10,650 7,940 5,680 3,860 3,110
,
20,290 18,130 15,390 11,960 9,060 6,640 4,670 3,840 R*H301M44 27,650 24,690 21,900 16,850 12,550 8,960 6,100 4,960 R*H325M44 30,190 26,960 23,920 18,520 13,940 10,110 6,910 5,500
43,050 36,380 28,110 21,270 15,700 11,190 9,270
-20°F -25°F
6,290 5,670 5,080 4,020 3,110 2,330 1,650 1,360 7,390 6,670 6,010 4,810 3,790 2,940 2,260 1,980 8,600 7,810 7,070 5,720 4,550 3,540 2,710 2,370 9,120 8,140 7,240 5,640 4,290 3,130 2,080 1,550
MODEL
R*H055M4 R*H080M4 R*H090M4 R*H100M4 R*H125M4
48,440
44M005H*R076,15064,7544H005H*R
+30°F +25°F +20°F +10°F 0°F -10°F
12,770 11,450 10,210 7,980 6,060 4,430 3,050 2,450 R*H151M44 15,710 13,840 12,120 9,070 6,540 4,460 2,750 2,030 R*H200M44 R*H251M44
17,070 15,200 13,450 10,280 7,590 5,370 3,590 2,850
19,030 16,970 15,060 11,650 8,770 6,380 4,430 3,600 R*H301M44 25,930 23,100 20,440 15,630 11,550 8,160 5,510 4,470 R*H325M44 28,200 25,120 22,260 17,130 12,800 9,160 6,110 4,740
45,580
44M005H*R046,84071,4544H005H*R
40,460 35,760 27,540 20,760 15,240 10,750 8,840
088,7005,9055,31057,81012,52040,33084,73003,2444M004H*R076,64089,1544H004H*R
002,7017,8064,21023,71093,32097,03099,43075,9344M004H*R088,34069,8444H004H*R
MODEL
R*H055H44
R*H090H44 R*H100H44
R*H151H44
R*H251H44
+40°F +35°F
7,410 6,660
10,350 9,390 11,050 9,920
16,790 14,910
21,130 18,930
110°F
AMBIENT
MODEL
R*H055M4 R*H080M4 R*H090M4 R*H100M4 R*H125M4
+30°F +25°F +20°F +10°F 0°F -10°F
5,630 5,050 4,520 3,550 2,720 2,000 1,380 1,110
6,490 5,850 5,250 4,170 3,260 2,520 1,930 1,700
7,600 6,900 6,230 5,020 3,960 3,070 2,340 2,040
8,850 7,900 7,030 5,480 4,170 3,040 2,020 1,510
11,210 10,000 8,880 6,860 5,130 3,650 2,380 1,820
-20°F -25°F
R*H151M44 13,510 11,830 10,290 7,560 5,310 3,450 1,940 1,270 R*H200M44 R*H251M44
14,700 13,010 11,430 8,590 6,210 4,260 2,700 2,040
16,510 14,680 12,970 9,930 7,360 5,240 3,520 2,790 R*H301M44 22,550 19,980 17,560 13,260 9,610 6,660 4,440 3,630
R*H325H44
34,160 30,410
R*H325M44 24,350 21,560 19,010 14,440 10,570 7,310 4,490 3,210