RUSH MH 3 Beam User Manual 45
Control and Programming
Control system .......................................................................................... DMX
DMX channels ............................................................................................... 19
Setting and addressing ........................ Control panel with backlit LCD display
DMX compliance ............................................................ USITT DMX512/1990
Pan and tilt speed................... Adjustable via onboard control panel and DMX
Head position ........................................................ Pan/tilt feedback correction
Construction
Color ......................................................................................................... Black
IP rating .................................................................................................... IP 20
Installation
Minimum distance from illuminated surfaces ............................. 12 m (39.4 ft.)
Location .................. Indoor use only, must be fastened to surface or structure
Mounting points ......................... Two quarter-turn brackets for rigging clamps
Orientation .................................................................................................. Any
Connections
AC power input .................................................................... Neutrik PowerCon
DMX data in/out ........................................................ 3-pin & 5-pin locking XLR
Electrical
AC power ........................................................................... 100-240 V, 50/60Hz
Fuse ........................................................................................................... T5A
Power supply unit ................................... Auto-ranging electronic switch mode
Typical power and current
110 V, 60 Hz ................................................................ 3.1 A, 348 W, PF 0.990
230 V, 50 Hz ................................................................ 1.6 A, 330 W, PF.0.917
Measurements made at nominal voltage. Allow for a deviation of +/- 10%.
Thermal
Cooling ............................................................................................. Forced air
Maximum ambient temperature (T
a
max.) .................................. 40° C (104° F)
Minimum ambient temperature (T
a
m i n) ..................................................... 0 ° C (3 2 ° F)
Total heat dissipation (calculated, +/- 10%) ................................ 1200 BTU/hr.
Approvals
EU safety ....................... EN 60598-2-17 (EN 60598-1), EN 62471, EN 62493
EU EMC ................................................ EN 55015, EN 55103-1, EN 55103-2,
......................................................... EN 61000-3-2, EN 61000-3-3, EN 61547
US safety (pending)............................................................................. UL 1573