Versus Installation Sheet.Q6 6/15/07 8:29 AM Page 1
V
OO
WWNNEER
&& II
Th
o
horoughly satisfied with your new Runtal Versus. We urge you to
t
contact your local Runtal representative if you have comments or
questions.This manual is intended to show installation and care for
your Runtal Versus. Electrical connection, or hydronic piping should
be performed by qualified professionals. The plug-in model is
intended for quick and easy homeowner installation.
•
in an upright position with the contr
NNSSTTAALLLLAATTIIOON
ank you for purchasing the Runtal Versus. We are very proud of
ur workmanship and quality, and we are certain that you will be
The electric Runtal Versus must be used only when wall mounted
Versus Installation Sheet.Q6 6/15/07 8:29 AM Page 2
I
I
NSSTTAALLLLAATTII
N
O
O
N
N
Please check the contents of the Runtal Versus carton to be
ure you have received all of the parts required. Runtal has
s
made every effort to ensure that all materials required for
mounting your unit have been included, and depending upon
specific installation conditions, you may have parts left over.
The mounting system has been designed for installation by one
person, but you may find an assistant helpful.
STEP 1DETERMINE WIRING
The electrician should start by providing the wiring to the Versus if the
model is electrical. The easiest termination of wires at the radiator is
accomplished using stranded conductors or 14/2 Romex (#12 AWG solid
wire is not recommended because of termination difficulties). If the unit
is hydronic, the plumber should determine the piping configuration.
STEP 2ATTACH THE FOUR POSTS TO THE RADIATOR
Position the four posts, parts A, B, & C as shown in the diagram on the
right. The placement of the mounting posts is flexible, however it is
recommended where possible that the posts be placed one on each side
of the vertical tubes between the second and third horizontal tubes
from the top and bottom. All four posts supplied with the towel radiator
must be used, half as top supports and half as bottom supports.
STEP 3POSITION THE RADIATOR ON THE WALL
To hang the unit either: (1) Ask an assistant to hold the unit against
the wall while you trace the four mounting posts. (2) Measur
the post positions. (3) Make a template by placing the towel radiator
onto a posterboar
mounting posts. The template is then taped to the wall.
d or a lar
ge piece of the carton and tracing the
OR
PIPING (IF
OTHER THAN A
PLUG-IN MODEL)
e out
Use Cardboard
from Radiator
Packing Carton to
make Template
STEP 4DETERMINE WALL CONSTRUCTION
For solid wood or placement into blocking use the provided #8 x 1-1/2" long
ew with washers, (par
scr
anchors with washers, (part G). Runtal towel radiators are very sturdy and
e should be taken that they ar
car
STEP 5DRILL HOLES
Drill holes for appropriate anchors in the middle of all four traced
circles. Use of the metal wall anchors will require a 5/16" hole; use
screw will require a 1/16" pilot hole.
of the 1-1/2
STEP 6FASTEN THE BRACKET SLEEVES TO THE WALL
Using the pr
attach the mounting sleeves (Par
with the set screw on the top for sleeves at the top of the radiator
and set screw on bottom for sleeves at bottom of radiator.
"
oper fasteners (either the metal anchors or #8 scr
t F). For dr
ywall constr
e secur
t D) to the wall. Fasten the sleeves
uction use the included metal
ely hung using all four mounting posts.
ews)
Set Screw on top for
mounting post at
top of radiator
Set Screw on bottom
for mounting post at
bottom of r
adiator
Versus Installation Sheet.Q6 6/15/07 8:29 AM Page 3
STEP 7HANG THE TOWEL RADIATOR ON THE WALL
Insert all four radiator posts into the four wall sleeves and tighten
each set screw.
STEP 8MAKE THE ELECTRICAL OR PIPING CONNECTIONS
Please refer to electrical details or hydronic details below.
Lights
Select
Button
STEP9(HY
Install air vent, (par
DRONICMODELSONLY
)
t H) and properly seal with pipe dope.
ELECTRICAL DETAILS
Electrical Installation Procedure:
All electrical towel radiators are designed for 120v AC 60HZ and must be GFCI protected. In the case of plug-in models
this protection is integrated into the cord provided. In the case of the direct wire models, GFIC protection must be
provided at the circuit breaker by a qualified electrician.
To install the direct wire model the electrician should follow these steps:
(1) Remove the two screws on the side of the control unit.
(2) Remove the control unit cover by pulling it forward.
3 Hour High
High
Medium
Low
Ready Light
(3) Remove the electrical connection access cover.
(4) Using the appropriate cement, cement Part M into Part N. Leave an 1/8” space
between these parts.
(5) Cut Part O to the required length and cement it to Parts N and P. A strain relief
(provided by the electrician ) is threaded to Part O.
(6) Run the electrical wires through the conduit, secure the strain relief and slide
Part M into the slot of the electical junction box as shown.
(7) Connect the three wires as
indicated.
(8) Replace the electrical
14/2
connection access cover and
the control unit cover, fasten
in place with two scr
ews.
Electrical Connection Access
Location of Conduit:
For right verticals: Starting at the bottom right side of the control go up 3/4” and over
to the left 5/8”. For left ver
3/4” and over to the right 5/8”. This is where you drill the hole in the wall to make the
connection to the junction box on the unit.
ticals: Starting at the bottom left side of the control go up
Connections for wires is as follows: Black to line, White to neutral, Green to ground
HYDRONIC PIPING DETAILS
BOTTOM TYPE- VERTICAL PIPING TO FLOORBOTTOM TYPE- VERTICAL PIPING TO WALL
Versus Installation Sheet.Q6 6/15/07 8:29 AM Page 4
OO
PPEERRAATTIIO
OPERATION
hen plugged in or direct-wired the red ready light
W
will always remain on unless the power is interrupted.
This ready light is the basic off position. Towel
radiators come complete with 5 power settings (Off,
Low, Medium, High, and 3 Hour Timer at High
etting). Press the select button to reach the desired
S
setting. While the fastest heating will be achieved on
the high setting (approximately 25 minutes to full
heat), the low or medium settings will produce
MAINTENANCE
Your Runtal towel radiator has been designed to
require the absolute minimum maintenance and care
under normal use. However, care should be taken
when cleaning the surface of the towel radiator.
As with any electrical appliance, the electric towel
radiator should only be cleaned when in the OFF
O
N
N
&& MM
NTTEE
AAIIN
ptimum heating efficiency. Cold rooms will benefit by
o
leaving the unit on longer. You may wish to use our
Electric Programmable Controller (EPC) for maximum
efficiency.
hot water heating system only. Typical concerns are:
ater temperature, flow rate, and controlling
w
thermostats and valves. Consult with the installing
heating contractor for the proper choice of the
available
position (unplugged if possible). The towel radiator’s
painted finish provides an elegant yet durable finish
to this welded steel product. Occasional cleaning of
this finish is best done with a water dampened cloth.
Under no circumstances should abrasive cleaners,
cloths or pads be used.
Hydronic models are made for a closed-loop
Hydronic models, and installation specifics.
NAA
N
N
N
CEE
C
IMPORTANT INSTRUCTIONS
When using electrical appliances, basic precautions should always be followed to reduce the risk of fire,
electric shock, and injury to persons, including:
1) Read all instructions before using this heater.
2) Extreme caution is necessary when any heater is used by
or near children or invalids and whenever the heater is
left operating and unattended.
3) Always unplug heater when not in use.
Do not operate any heater with a damaged cor
4)
or after the heater malfunctions, or has been damaged
in any manner. Return the heater to an authorized
service facility for examination, electrical or mechanical
.
adjustment, or r
Do not r
5)
cord with throw rugs, runners, or the like. Arrange the
cord away from traffic areas and where it will not be
tripped over.
o disconnect heater
T
6)
the plug from the outlet.
7) Use this heater only as described in this manual. Any
other use not r
cause fire, electric shock, or injury to persons.
un the cord under carpeting. Do not cover the
epair
ess contr
, pr
ecommended by the manufactur
ol to of
f, then remove
d or plug
er may
8) Avoid the use of an extension cord, because the
extension cord may overheat and cause a risk of fire.
However if you have to use an extension cord, the cord
should be NO. 18 AWG min. size and rated not less than
875 watts. For 900 watt models, the cord should be NO.
WG min. size and
16 A
9) This heater is for use on 120 volts. The plug-in model has
a cord as shown in A of drawings below. An adapter as
shown at C is available for connecting three-blade
ounding-type plugs to two slot
gr
grounding lug extending from the adapter must be
connected to a permanent ground such as a properly
grounded outlet box. The adapter should not be used if
a thr