Neptune Installation Sheet.Q6 6/18/07 9:53 AM Page 1
N
OO
WWNNEER
&& II
Th
o
horoughly satisfied with your new Runtal Neptune. We urge you to
t
contact your local Runtal representative if you have comments or
questions.This manual is intended to show installation and care for your
Runtal Neptune. Electrical connection, or hydronic piping should be
performed by qualified professionals. The plug-in model is intended for
quick and easy homeowner installation.
•
an upright position with the contr
NNSSTTAALLLLAATTIIOON
ank you for purchasing the Runtal Neptune. We are very proud of
ur workmanship and quality, and we are certain that you will be
The electric Runtal Neptune must be used only when wall mounted in
Neptune Installation Sheet.Q6 6/18/07 9:53 AM Page 2
I
I
NSSTTAALLLLAATTII
N
O
O
N
N
Please check the contents of the Runtal Neptune carton to be
ure you have received all of the parts required. Runtal has
s
made every effort to ensure that all materials required for
mounting your unit have been included, and depending upon
specific installation conditions, you may have parts left over.
The mounting system has been designed for installation by one
person, but you may find an assistant helpful.
R
STEP 1DETERMINE WIRING
The electrician should start by providing the wiring to the Neptune if
the model is electrical. The easiest termination of wires at the radiator is
accomplished using stranded conductors or 14/2 Romex (#12 AWG solid
wire is not recommended because of termination difficulties). If the unit
is hydronic, the plumber should determine the piping configuration.
O
PIPING (IF
OTHER THAN A
PLUG-IN MODEL)
STEP 2ATTACH THE FOUR POSTS TO THE RADIATOR
Position the four posts (Parts A) into their fixed positions on the unit.
All four posts supplied with the towel radiator must be used, half as top
supports and half as bottom supports.
STEP 3POSITION THE RADIATOR ON THE WALL
To hang the unit either: (1) Ask an assistant to hold the unit against
the wall while you trace the four mounting posts. (2) Measure out
the post positions. (3) Make a template by placing the towel radiator
onto a posterboard or a large piece of the carton and tracing the
mounting posts. The template is then taped to the wall.
STEP 4DETERMINE WALL CONSTR
For solid wood or placement into blocking use the provided #8 x 1-1/2" long
ew with washers, (par
scr
anchors with washers, (part G). Runtal towel radiators are very sturdy and
care should be taken that they are securely hung using all four mounting posts.
STEP 5DRILL HOLES
Drill holes for appropriate anchors in the middle of all four traced
circles. Use of the metal wall anchors will require a 5/16" hole; use
of the 1-1/2" screw will require a 1/16" pilot hole.
STEP 6FASTEN THE BRACKET SLEEVES TO THE WALL
Using the proper fasteners (either the metal anchors or #8 screws)
attach the mounting sleeves (Part B) to the wall. Fasten the sleeves
with the set scr
ew positioned on the inside.
t F). For dr
ywall construction use the included metal
UCTION
Use Cardboard
from Radiator
Packing Carton to
make Template
Set Screws should be
facing toward the
inside of the radiator
Set Screws should be
inside of the r
facing tow
ard the
adiator
Neptune Installation Sheet.Q6 6/18/07 9:53 AM Page 3
STEP 7HANG THE TOWEL RADIATOR ON THE WALL
Insert all four radiator posts into the four wall sleeves and tighten
each set screw.
STEP 8MAKE THE ELECTRICAL OR PIPING CONNECTIONS
Please refer to electrical details or hydronic details below.
Lights
Select
Button
STEP9(HY
Install air vent, (par
DRONICMODELSONLY
)
t H) and properly seal with pipe dope.
ELECTRICAL DETAILS
Electrical Installation Procedure:
All electrical towel radiators are designed for 120v AC 60HZ and must be GFCI protected. In the case of plug-in models
this protection is integrated into the cord provided. In the case of the direct wire models, GFIC protection must be
provided at the circuit breaker by a qualified electrician.
To install the direct wire model the electrician should follow these steps:
(1) Remove the two screws on the side of the control unit.
3 Hour High
High
Medium
Low
Ready Light
Electrical Connection Access
(2) Remove the control unit cover by pulling it forward.
(3) Remove the electrical connection access cover.
(4) Using the appropriate cement, cement Part M into Part N. Leave an 1/8” space
between these parts.
(5) Cut Part O to the required length and cement it to Parts N and P. A strain relief
(provided by the electrician ) is threaded to Part O.
(6) Run the electrical wires through the conduit, secure the strain relief and slide
t M into the slot of the electrical junction box as shown.
Par
Connect the three wires as
(7)
indicated.
Replace the electrical
(8)
14/2
connection access cover and
the control unit cover, fasten
in place with two screws.
Location of Conduit:
Starting at the bottom right side of the contr
where you drill the hole in the wall to make the connection to the junction box on the unit.
ol go up 3/4” and over to the left 3/4”. This is
Connections for wires is as follows: Black to line, White to neutral, Green to ground
HYDRONIC PIPING DET
AILS
BOTTOM TYPE- VERTICAL PIPING TO FLOORBOTTOM TYPE- VERTICAL PIPING TO WALL
Neptune Installation Sheet.Q6 6/18/07 9:53 AM Page 4
OO
PPEERRAATTIIO
ERATION
OP
When plugged in or direct-wired the red ready light
will always remain on unless the power is interrupted.
This ready light is the basic off position. Towel
radiators come complete with 5 power settings (Off,
Low, Medium, High, and 3 Hour Timer at High
Setting). Press the select button to reach the desired
setting. While the fastest heating will be achieved on
the high setting (approximately 25 minutes to full
heat), the low or medium settings will produce
MAINTENANCE
Your Runtal towel radiator has been designed to
require the absolute minimum maintenance and care
under normal use. However, care should be taken
when cleaning the surface of the towel radiator.
As with any electrical appliance, the electric towel
radiator should only be cleaned when in the OFF
O
N
N
&& MM
NTTEE
AAIIN
optimum heating efficiency. Cold rooms will benefit by
leaving the unit on longer. You may wish to use our
Electric Programmable Controller (EPC) for maximum
efficiency.
hot water heating system only. Typical concerns are:
water temperature, flow rate, and controlling
thermostats and valves. Consult with the installing
heating contractor for the proper choice of the
available Hydronic models, and installation specifics.
position (unplugged if possible). The towel radiator’s
painted or chrome finish provides an elegant yet
durable finish to this welded steel product. Occasional
cleaning of this finish is best done with a water
dampened cloth.
abrasive cleaners, cloths or pads be used.
Hydronic models are made for a closed-loop
NAA
N
Under no circumstances should
N
N
CEE
C
IMPORTANT INSTRUCTIONS
When using electrical appliances, basic precautions should always be followed to reduce the risk of fire,
electric shock, and injury to persons, including:
1) Read all instructions before using this heater.
2) Extreme caution is necessary when any heater is used
by or near children or invalids and whenever the
heater is left operating and unattended.
3) Always unplug heater when not in use.
4) Do not operate any heater with a damaged cord or
plug or after the heater malfunctions, or has been
damaged in any manner. Return the heater to an
authorized service facility for examination, electrical
or mechanical adjustment, or repair.
5) Do not run the cord under carpeting. Do not cover
the cord with throw rugs, runners, or the like.
Arrange the cord away from traffic areas and where
it will not be tripped over
6) To disconnect heater, press control to off, then
remove the plug from the outlet.
7)
Use this heater only as described in this manual. Any
other use not r
may cause fire, electric shock, or injury to persons.
ecommended by the manufacturer
.
8) Avoid the use of an extension cord, because the
extension cord may overheat and cause a risk of fire.
However, if you have to use an extension cord, the
cord should be No. 18 AWG min. size and rated not
less than 875 watts.
9) This heater is for use on 120 volts. The plug-in model
has a cord as shown in A of drawings below. An
adapter as shown at C is available for connecting
three-blade grounding-type plugs to two slot
eceptacles. The green grounding lug extending from
r
the adapter must be connected to a permanent
ground such as a properly grounded outlet box. The
adapter should not be used if a thr
receptacle is available.
Cover of
grounded
outlet box
Grounding Pin
C
Grounding Means
Metal Screw
A
ee-slot gr
B
ounded
RUNTAL NORTH AMERICA,INC.
el: (978) 373-1666
T
Fax (978) 372-7140
www.runtalnorthamerica.com
10) Connect to properly grounded outlets only.
11) Do not use outdoors.
SAVE THESE INSTRUCTIONS