RULE 35A, 35FA, 37A, 37FA, 40A User guide

...
Page 1
Features
• Patent pending snap switch design
• Snap switch tested to over 1,000,000 cycles @ 12V
• Highly abrasion resistant marine grade blocked wire
• Exclusive moisture tight seals
• Environmentally friendly mercury free design.
Models
Model Description
35A Rule-a-Matic 14A
35FA Rule-a-Matic with fuse holder 14A
37A Super Switch 20A
37FA Super Switch with fuse holder 20A
40A Rule-a-Matic covered switch 20A
40FA Rule-a-Matic covered switch 20A
with fuse holder
Float Switches
The N ext G ener a tio n
Models 35A, 35FA, 37A, 37FA, 40A, 40FA
Dimensional Drawings
Dimensions in Inches (millimeters)
Installation Instructions
The Rule-a-Matic, Super Switch, and Rule-a-Matic Plus float switches are suitable for any submersible bilge pump with an operating current rating as listed below.
Maximum Current Rating
Voltage Rule-a-Matic Super Switch /
Rule-a-Matic Plus
12V 14A 20A
24V 7A 10A
32V n/a 6.5A
All switches will turn the pump on when the water level reaches 2” (51mm) and will turn the pump off when water level falls to 3/4” (19mm). They can also be used to operate high water alarm systems.
This product must be fused with the correct recommended fuse size for the pump to which it is connected. Do NOT use these switches in applications where the pump is operating above the maximum current in the table above.
Specifications
Model Voltage Wire Size Wire Length Max. Amps Guard Warranty
35A 12/24/32 VDC 16 Gauge (1.29mm) 28” (712 mm) 14 No 2 Years
37A 12/24/32 VDC 14 Gauge (1.63mm) 28” (712 mm) 20 No 5 Years
40A 12/24/32 VDC 14 Gauge (1.63mm) 28” (712 mm) 20 Yes 2 Years
Page 2
Mounting Instructions
FWD
30°
Figure 1
F
igure 2
AFT
Switch Base
AdapterPump Base (Strainer)
Screw
Fuse
Battery
Hot Side
(+ usually)
Pump
Float Switch
Red Indicator Light
Automatic On-Off Toggle Switch
All these parts are incluced in the Deluxe Switch Control Panel, No. 41 Series
Ground (typical)
Ground (typical)
On-Off Switch
Best System - Provides Manual On/Automatic Control of the
Pump and Red LIght Indication of Operation
Simple System - Provides Automatic Operation of Pump
Fuse
Battery
Hot Side
(+ usually)
Pump
Float Switch
Figure 3
For best operation, the Rule switch should be located on
flat surface in the bilge compartment. Do not exceed
a the installation angles as described in the diagrams below as this will affect switch performance.
It is important that the switch is mounted 1/4” (6mm) above the bottom of the pump strainer. This will assure a positive shut off of the pump.
1. Position the switch parallel to the vessel's water line with the wire exiting the switch toward the stern.
2. For models 35A, 35FA, 37A, 37FA, unclip the switch base and attach base to the surface using suitable stainless steel screws. Re-clip switch into base (see Figure 3).
3. For models 40A and 40FA partially fit one screw in place and slide the switch into place before fitting second screw.
4. Ensure there is free movement of the float.
The Rule Switch may be mounted directly on to non automatic Rule pumps that accept an adapter (pumps with capacity of 1500 GPH (5678 lph) or greater). Rule adapters (model 64 and 65) are also available separately.
Electrical Installation
ire the Rule switch as shown in the diagrams below.
W The positive (+) side of the battery should connect directly to the fuse (note models 35FA, 37FA, and 40FA include a fuse holder). Adding a fuse will prevent damage to both the pump and switch should an electrical problem occur. When adding additional wire up to 20 ft (6m), the wire added should be the same size (gauge) or larger than the size of the wire leads coming directly from the pump. For installations requiring over 20 ft (6m) of additional wire, the size of the added wire should be increased (e.g. if pump is fitted with 14 gauge, added wire should be increased to 12 gauge (2.05mm)).
THIS PRODUCT
IMPORTANT
S H O U L D B E
FUSED WITH THE RECOMMENDED FUSE SIZE FOR THE PUMP TO WHICH IT IS CONNECTED!
Operation
Rule float switches are designed to automatically turn the bilge pump on and off as required. If it is desired to pump the water level even lower, the pump can be operated by a 3-way Rule panel switch (models 41,42, and 43) in the “manual” mode (see below diagram for illustration). To test the operation of the 40A /40FA switch and pump, press down on the lever located in the back of the switch. This will lift the float mechanism, which will turn on the bilge pump. Periodically clean any accumu­lated debris from around the switch or integral switch guard. This will allow free flow of water to the float.
Wiring Diagrams
IMPORTANT
HIGHEST WATER LEVEL. WIRES SHOULD BE SEALED WITH A WATERPROOF MARINE SEALANT TO PREVENT WIRE CORROSION!
© 2011 Xylem Inc Printed in U.S.A. All Rights Reserved Form: 950-0290 Rev. C 11/2012