Ruijie RG-S8600E Series Quick Installaion Manual

RG-S8600E Series Switches Quick Installation Guide V1.02
Copyright Statement
or commercial use of this document or any portion of this document, in any form or by any means, without the prior written consent of Ruijie Networks is prohibited.
Exemption Statement
This document is provided “as is”. The contents of this document are subject to change without any notice. Please obtain the latest information through the Ruijie Networks website. Ruijie Networks endeavors to ensure content accuracy and will not shoulder any responsibility for losses and damages caused due to content omissions, inaccuracies or errors.
Preface
Thank you for using our products. This manual will guide you through the installation of the device. This manual describes the functional and physical features and provides the device installation steps, hardware
troubleshooting, module technical specifications, and specifications and usage guidelines for cables and connectors.
Audience
It is intended for the users who have some experience in installing and maintaining network hardware. At the same time, it is assumed that the users are already familiar with the related terms and concepts.
Obtaining Technical Assistance
Ruijie Networks Website: http://www.ruijienetworks.com/ Service Email: service_rj@ruijienetworks.com Technical Support: http://www.ruijienetworks.com/service.aspx Technical Support Hotline: +86-4008-111-000
Related Documents
Documents
Description
Configuration Guide
Describes network protocols and related mechanisms that supported by the product, with configuration examples.
Command Reference
Describes the related configuration commands, including command modes, parameter descriptions, usage guides, and related examples.
Symbol Conventions
Means reader take note. Notes contain helpful suggestions or references.
Means reader be careful. In this situation, you might do something that could result in equipment damage or loss of data.
1 Product Overview
Launched by Ruijie independently, RG-S8600E series next generation core switches adopt the Full Mesh/Clos architecture and support large buffer. RG-S8600E series support dual supervisor modules and power supply redundancy, which are available in three models, namely, RG-S8605E, RG-S8607E, RG-S8610E and RG-S8612E.
RG-S8605E adopts Full Mesh architecture and supports dual supervisor modules and provides 3 slots for service modules. RG-S8607E adopts Full Mesh architecture and supports dual supervisor modules and provides 5 slots for service modules. RG-S8610E adopts Clos architecture and supports dual supervisor modules and provides 8 slots for service modules. RG-S8612E adopts Clos architecture and supports dual supervisor modules and provides 8 slots for service modules.
2 Safety Precautions for Movement
RG-S8600E series is large and heavy. When you carry them, please pay attention to the following requirements:
Unplug all power cords before you move the switch. Note: There may be more than one power cord. Remove the power supply, fans and service modules to reduce the chassis weight before moving the switch for a long distance. At least 4 people are needed to move the switch. Keep balance when moving the switch by 4 people, and keep the pace with each other. Grasp the handles on both sides of the chassis, not the power supply handle, fan handle or the rear panel handle. Those handles
are just used to install and remove corresponding parts, and cannot bear the whole switch weight.
The whole switch weight may be higher than 80 kg during the movement.
To correctly move the RG-S8605E, refer to the Figure 2-1. For the RG-S8607E, refer to Figure 2-2. For the RG-S8610E, refer to Figure 2-3. And for RG-S8612E, refer to Figure 2-4.
Note that the following figures are just the schematic diagrams, do not insert the line card and power supply when moving the chassis to avoid the chassis weight increment or line card damage.
Figure 2-1 Moving the RG-S8605E Switch
Figure 2-2 Moving the RG-S8607E Switch
·
Figure 2-3 Moving the RG-S8610E Switch
Figure 2-4 Moving the RG-S8612E Switch
·
3 Preparations Before Installation
3.1 ESD Prevention
Precaution
To avoid the damages from static electricity to the internal parts of switches, do as follows:
ESD prevention measures are taken in the sites where switches are installed. Wear the antistatic wrist strap while installing various switch parts, especially when you may touch circuit boards with hands. Grasp the edge of modules. Do not touch the parts or printed circuits directly.
Wearing the anti-static wrist strap
The antistatic wrist strap is shipped with RG-S8600E, which is used as follows:
1. Stretch out your hand into the antistatic wrist strap.
2. Lock the wrist strap and make sure that the metal part of the antistatic wrist strap is in good contact with skin.
3. Insert the antistatic wrist strap in the antistatic wrist strap jack of the switch chassis or clip on the grounding pole of the chassis. The antistatic wrist strap jack is located on the front panel of the chassis marked with yellow ESD.
4. The antistatic wrist strap is grounded well and the DC electric resistance between the body and the ground is in the range of 1 to 10 mega ohms.
Figure 3-1 ESD Prevention on RG-S8605E
·
Figure 3-2 ESD Prevention on RG-S8607E
Figure 3-3 ESD Prevention on RG-S8610E
·
Figure 3-4 ESD Prevention on RG-S8612E
·
3.2 Installation Site
RG-S8600E series must be used in the room. To ensure normal operation and a prolonged use life of the device, the installation site must meet the requirements of weight capacity, humidity , cleanness, EMI consideration, grounding system, power, and ventilation. See the Preparation before Installation chapter of RG-S8600E Series Switches Hardware Installation and Reference Guide for details.
3.3 Cabinet Mounting
Make sure the cabinet complies with the following conditions:
Install the switch in a 19-inch cabinet in 4-port form hold. Be sure the distance between two square hole strips, one on each side, is 465 mm.
Figure 3-4 19-inch Cabinet
·
Be sure that the square hold strip is at least 180 mm far from the outboard front door and the door is at most 25 mm thick to
ensure a minimum available distance of 155 mm. The front door is at least 1000 mm far from the back door,
Figure 3-5 Cabinet Dimensions
Be sure that the slide rail in the cabinet is enough to bear the weight of a RG-S8600E and its installation accessories.
·
Be sure that the cabinet provides an earthing terminal for the switch to be grounded. Be sure that the front and back doors of the cabinet have porosities greater than 50% for good ventilation and heat dissipation.
3.4 Installation Tools
Common Tools
Cross screwdriver, straight screwdriver, related electric and optical cables Bolts, diagonal pliers, straps
Special Tools
Anti-static glove, stripping pliers, crimping pliers, crimping pliers for the crystal head, wire cutter
Fiber Optic Cleaning Tools
Air-laid paper, optical fiber microscope
Meter
Multimeter, bit error rate tester (BERT), optical power meter
The tool kit is customer supplied.
3.5 Fiber Connection
Before connecting fiber cables, make sure the model of the optical transceiver and fiber type match the optical port. The transmit port on the local device should be connected to the receive port on the peer device and vice versa.
3.6 Unpacking
Goods Checklist
Chassis Carton
Device panels are installed and operational. Fans, screwdriver, anti-static wrist strap, yellow/green grounding wires, quick installation
guide, packing list
Module Carton
Modules, packing list, documentation
A normal delivery should contain the above mentioned items, which may differ from the actual delivery, depending on purchase contracts. Please check your goods carefully against the packing list or purchase contract. If you have any questions or there are
any errors, please contact your distributor.
·
4 Installing the Switch
4.1 Installation Flowchart
Figure 4-1 Installation Flowchart
4.2 Installing Slide Rails
When installing slide rails for the RG-S8600E, ensure that the plane to carry the chassis should be installed on the plane of delimiters of 1 RU, as shown in Figure 4-2.
Figure 4-2 Installing Slide Rails
·
Note: 1 and 2 represent 1 RU delimiters.
Before installing a slide rail, please verify that it is firm enough to bear the device weight and its installation accessories. The RG-S8600E series switch is available in three models with different heights. There are variable kinds of slide rails. The rail appearance and installation is subject to actual conditions. In order to keep the cabinet balanced, please install the slide rail to as low a position as possible in the cabinet if only one
RG-S8600E switch is installed. If you are mounting multiple device to the cabinet, mount the heaviest device in the lowest position of the cabinet first and proceed to mount the rest of the devices from bottom to top.
4.3 Installing the Air Filter (Optional)
Install air filters of the supervisor module, service module and switch fabric module on the RG-S8600E.
If an air filter is used for a long time, dust may block its air vent, weakening system ventilation. It is recommended you wash the air filter every three months.
Installing the Air Filters of the Supervisor Module and Service Module
(1) RG-S8605E Figure 4-3 Air Filter of the Supervisor Module and Service Module on RG-S8605E Switch
·
Note:
1 Captive screws
2 Air filter
To install the air filter , follow these steps:
1) Insert the air filter along the slide rail. Note the direction identifier to ensure the correct direction.
2) Use a screwdriver to tighten the captive screws on the air filter.
Figure 4-4 Installing the Air Filter of the Supervisor Module and Service Module on RG-S8605E Switch
(2) RG-S8607E Figure 4-5 Air Filter of the Supervisor Module and Service Module on RG-S8607E Switch
·
Note:
1 Captive screws
2 Air filter
To install the air filter , follow these steps:
1) Insert the air filter along the slide rail. Note the direction identifier to ensure the correct direction.
2) Use a screwdriver to tighten the captive screws on the air filter.
Figure 4-6 Installing the Air Filter of the Supervisor Module and Service Module on RG-S8607E Switch
·
(3) RG-S8610E
To install the air filter , follow these steps:
1) Seat the air filter in the plastic cover and tighten screws.
2) Install the plastic cover before the air filter by pressing firmly the two buttons on the both sides of the plastic cover.
Figure 4-7 Installing the Air Filter of the Supervisor Module and Service Module on RG-S8610E Switch
Installing the Air Filters of the Switch Fabric Module
(1) RG-S8610E To install the air filter, follow these steps:
1) Seat the air filter in the plastic cover and tighten screws.
2) Install the plastic cover before the air filter by pressing firmly the two buttons on the both sides of the plastic cover.
Figure 4-8 Installing the Air Filter of the Switch Fabric Module on RG-S8610E Switch
·
Note:
1 Air filter
4.4 Installing Brackets
Wear the antistatic wrist strap and make sure the antistatic wrist strap is grounded well. The brackets of RG-S8605E, RG-S8607E, RG-S8610E and RG-S8612E are installed before delivery, as shown in figure 4-9,
4-10, 4-11 and 4-12. If you want to adjust the location of the bracket, see figure 4-13, 4-14 and 4-15. Location adjustment of brackets is not supported on the RG-S8612E.
Install the bracket to the front chassis side
(1) RG-S8605E bracket (installed before delivery) Figure 4-9 Installing Brackets to Front Chassis Side
(2) RG-S8607E bracket (installed before delivery) Figure 4-10 Installing Brackets to Front Chassis Side
·
(3) RG-S8610E bracket (installed before delivery) Figure 4-11 Installing Bracket to Front Chassis Side
·
(4) RG-S8612E bracket (installed before delivery) Figure 4-12 Installing Bracket to Front Chassis Side
Move the bracket backward
(1) RG-S8605E bracket
1. Remove the bracket from the front chassis side.
2. Install the bracket at a backward location, as shown in figure 4-13: Figure 4-13 RG-S8605E Bracket
·
(2) RG-S8607E bracket
1. Remove the bracket from the front chassis side.
2. Install the bracket at a backward location, as shown in figure 4-14: Figure 4-14 RG-S8607E Bracket
(3) RG-S8610E bracket
1. Remove the bracket from the front chassis side.
2. Install the bracket at a backward location, as shown in figure 4-15:
·
Figure 4-15 RG-S8610E Bracket
4.5 Mounting Cabling Rack
Make sure the antistatic wrist strap is grounded well and wear the antistatic wrist strap. The RG-S8610E cabling rack is mounted before delivery while RG-S8605E, RG-S8607E and RG-S8612E not. Please refer to
the following steps and figures for installation.
Mount the cabling rack for RG-S8605E
1. Take out cabling racks.
2. There are three cabling racks on each side respectively. Pay attention to the direction to mount cabling racks, as shown in figure 4-16.
3. Align the screw holes on the cabling rack with those on the chassis and tighten the screws, as shown in figure 4-16.
·
Figure 4-16 Mounting the Cabling Rack for RG-S8605E
Mount the cabling rack for RG-S8607E
1) Take out cabling racks.
2) There are five cabling racks on each side respectively. Pay attention to the direction to mount cabling racks, as shown in figure 4-17.
3) Align the screw holes on the cabling rack with those on the chassis and tighten the screws, as shown in figure 4-17.
Figure 4-17 Mounting the Cabling Rack for RG-S8607E
·
Mount the cabling rack for RG-S8610E (mounted before delivery)
Figure 4-18 Mounting the Cabling Rack for RG-S8610E
Mount the cabling rack for RG-S8612E (mounted before delivery)
Figure 4-19 Mounting the Cabling Rack for RG-S8612E
4.6 Mounting the Switch to a Cabinet
Precautions
Before mounting RG-S8600E series to the cabinet, first verify that the front and back brackets of the cabinet are at the right locations. If the bracket is too far forward, the front panel of the equipment may be too close to the front door, so that the front door cannot be
·
closed when network cables and fibers are connected. Usually, you should reserve at least 10 mm between the front panel of the switch and the front door of the cabinet. Before mounting the switch to a cabinet, you need to address the following conditions:
Fasten the cabinet. Insert various modules in the frame properly. Remove any obstacle in the frame and the surrounding environment. Prepare the equipment and move it to the place near the cabinet where you can handle it easily.
Five people is recommended to carry or lift the switch. One is responsible for directing and the other four carrying or lifting the switch.
Installation Steps
Measure the cabinet height and locate the position on the bracket for installing the slide rail. Then locate the position on the other bracket through the carrying plane and mark the locations. Install seven cage nuts on the marked square holes on each bracket as shown in figure 4-18.
Figure 4-20 Slide Rail Installation Positions
Place the switch on the slide rail, and drive it smoothly into the cabinet until the front bracket reaches the square hole strip. Align the installation holes on the bracket with the cage nuts on the square hole strip, and mount them with screws.
Figure 4-21 Mounting the Switch into the Cabinet
·
4.7 Connecting the System Ground
A good grounding system protects your switch against lightning strikes and interferences and ensures its normal operation and reliability.
Precautions
The sectional area of the grounding wire should be determined according to the possible maximum current. Cables of good
conductor should be used.
Do not use bare wire. The grounding resistance for combined grounding should be less than 1Ω.
Connecting the System Ground
To connect the system ground, follow these steps:
1) Remove the two screws on the rear of the switch.
2) Attach the one end of the grounding wire to the switch with the two screws. Connect the other end of the grounding wire to the grounding wire of the cabinet.
Figure 4-22 Grounding Point on the Rear of the RG-S8605E Switch
·
Figure 4-23 Grounding Point on the Rear of the RG-S8607E Switch
Figure 4-24 Grounding Point on the Rear of the RG-S8610E Switch
·
Figure 4-25 Grounding Point on the Rear of the RG-S8612E Switch
To guarantee the security of the person and the device, the RG-N18000 must be well-grounded. The grounding resistance shall be less than 1Ω.
A service person shall check whether or not the socket-outlet from which the equipment is to be powered provides a connection the building protective earth. If not, the service person shall arrange for the installation of a protective earthing conductor from the separate protective earthing terminal to the protective earth wire in the building.
The socket-outlet shall be installed near the equipment and shall be easily. When installing the unit, always make the ground connection first and disconnect it last. The cross-sectional area of protective earthing conductor shall be at least 2.5 mm2 (12AWG).
·
4.8 Installing Power Supplies
The RG-S8600E series switches provide AC power supplies including RG-PA1600I, RG-PA600I, RG-PA1600I-P, RG-PA1600I-PL, and RG-PA3000I-PL as well as DC power supplies including RG-PD1600I and RG-PD600I. Before performing the following procedures, wear an anti-static wrist trap close to your kin and keep it grounded well.
The RG-S8605E power system provides two power supply slots, which support 1+1 redundancy. It is recommended users configure power supply redundancy. The power system also provides one PoE port.
The RG-S8607E power system provides four power supply slots, which support n+m redundancy. The power system also provides two PoE ports, which support 1+1 redundancy. It is recommended users configure power supply redundancy.
The RG-S8610E power system provides eight power supply slots, which support n+m redundancy. The power system also provides two PoE ports, which support 1+1 redundancy. It is recommended users configure power supply redundancy.
The RG-S8612E power system provides six power supply slots, which support n+m redundancy. By adopting the external PSE power frame, the power system also provides two PoE ports, which support 1+1 redundancy. It is recommended users configure power supply redundancy.
When RG-S8605E/ RG-S8607E/ RG-S8610E/ RG-S8612E is powered up by more than one source, the power must be in the same model.
The RG-PA1600I-P power system is applicable to RG-S8605E/ RG-S8607E/ RG-S8610E of versions earlier than V1.20 (V1.20 excluded).
The RG-PA1600I-PL/ RG-PA3000I-PL power system is applicable to RG-S8612E and RG-S8605E/ RG-S8607E/ RG-S8610E of versions later than V1.20 (V1.20 included).
If you want to carry or lift the power module, please hold the bottom of the module with your hand instead of carrying the module by the handle. Otherwise, the module may be damaged.
Before inserting or removing the power module, please verify whether the switch is well mounted. The switch is high, avoid switch tumble when you are inserting or removing the power module.
If you want to hot swap a power supply, please make sure that the interval between two operation is greater than 30s. Please do not touch the golden finger part of the power supply which is removed after power off in case that capacitor discharge
is not full.
Install the AC power system
1. Loosen the captive screws on the fake panel covering the power slot at the rear of the chassis.
2. Insert the power module into the slot along the rail until the rear connector of the power module stays in good contact with the rear
panel.
3. Tighten the captive screws on the power module to fix it.
Figure 4-23 Installing Power Supplies
·
Install the PoE power system
The PoE power system and the DC power system share the same installation steps with the AC power system.
The total power of power supplies of the RG-S8600E must be greater than the working power of the host. Otherwise, some modules may fail to start.
The host power is the summation of the power of all working modules, including the supervisor module, service module and fan. For the power of each module, please refer to
RG-S8600E Series Switches Hardware Installation and Reference Guide.
4.9 Installing Fans
The RG-S8600E provides a ventilation system: M05-FAN for RG-S8605E, M07-FAN for RG-S8607E, M10-FAN-R, M10-FAN-F for RG-S8610E and M12-FAN-R for RG-S8612E. Before the following procedures, wear an anti-static wrist trap close to your skin and have it properly grounded.
Steps for installing the M05-FAN fan tray:
1) Install the fan tray into the fan slot in the rear panel of RG-S8605E. Note the direction identifier of the fan tray’s name to ensure the correct direction.
2) Tighten the captive screws on the fan tray with a screwdriver.
Figure 4-27 Installing M05-FAN Fan Tray
·
Steps for installing the M07-FAN fan tray:
1) Install the fan tray into the fan slot in the rear panel of RG-S8607E. Note the direction identifier of the fan tray’s name to ensure the correct direction.
2) Tighten the captive screws on the fan tray with a screwdriver.
Figure 4-28 Installing M07-FAN Fan Tray
·
Steps for installing the M10-FAN-R fan tray:
1) Install the fan tray into the fan slot in the rear panel of RG-S8610E. Note the direction identifier of the fan tray’s name to ensure the correct direction.
2) Tighten the captive screws on the fan tray with a screwdriver.
Figure 4-29 Installing M10-FAN-R Fan Tray
Steps for installing the M10-FAN-F fan tray:
1) Install the fan tray into the fan slot in the front panel of RG-S8610E. Note the direction identifier of the fan tray’s name to ensure the correct direction.
2) Tighten the captive screws on the fan tray with a screwdriver.
Figure 4-30 Installing M10-FAN-F Fan Tray
·
Steps for installing the M12-FAN-R fan tray:
1) Install the fan tray into the fan slot in the front panel of RG-S8612E. Note the direction identifier of the fan tray’s name to ensure the correct direction.
2) Tighten the captive screws on the fan tray with a screwdriver.
Figure 4-31 Installing M12-FAN-R Fan Tray
Do not remove the fan tray forcibly. You can use the fan handle. Otherwise, component damage may occur, which causes deformation of the fan tray, and the fan tray cannot be removed.
4.10 Installing Modules
·
Always wear an anti-static wrist strap when installing the module and the metallic part of the anti-static wrist strap should be fully touched with the skin. Besides, for the sake of security, please not touch any component of the module.
Do not hold the edge of the PCB or collide the components on the PCB. Do not plug/unplug a supervisor module, service module or switch fabric module forcedly, use the ejector.
Select slots
The supervisor module, service module and the switch fabric module adopt the design of self-locking lever. Please refer to figure 4-28 for operation.
1. Lever Operation
Hold down the button on the lever (refer to 1 in figure 4-28) and then pull out the lever (refer to 2 in figure 4-22). Figure 4-32 Pulling out the Lever
Figure 4-33 Pulling out the Levers with Both Hands
·
2) Select slots (RG-S8605E)
Figure 4-34 RG-S8605E Chassis
Note:
1 Supervisor module slot 2 Service modulo slot
3) Select slots (RG-S8607E)
Figure 4-35 RG-S8607E Chassis
Note:
1 Supervisor module slot 2 Service module slot
4) Select slots (RG-S8610E)
Figure 4-36 RG-S8610E Chassis
·
Note:
1 Supervisor module slot 2 Service module slot 3 Switch fabric module slot
5) Select slots (RG-S8612E)
Figure 4-37 RG-S8612E Chassis
Note:
1 Service module slot 2 Supervisor module slot 3 Switch fabric module slot
Install modules
For the installation of the supervisor module, service module and switch fabric module, please refer to figure 4-38, 4-39, 4-40 and 4-41.
Install modules into slots (RG-S8605E)
·
1) Pull out both levers (refer to in figure 4-38).
2) Insert the module into the slot along the rail and drive it ahead smoothly (refer to in figure 4-38).
3) Push both levers toward the slot (refer to in figure 4-38).
Figure 4-38 RG-S8605E in the Chassis
Install modules into slots (RG-S8607E)
1) Pull out both levers (refer to in figure 4-39).
2) Insert the module into the slot along the rail and drive it ahead smoothly (refer to in figure 4-39).
3) Push both levers toward the slot (refer to in figure 4-39).
Figure 4-39 RG-S8607E in the Chassis
Install modules into slots (RG-S8610E)
1) Pull out both levers (refer to in figure 4-40).
2) Insert the module into the slot along the rail and drive it ahead smoothly (refer to in figure 4-40).
3) Push both levers toward the slot (refer to in figure 4-40).
Figure 4-40 RG-S8610E in the Chassis
·
Install modules into slots (RG-S8612E)
1) Pull out both levers (refer to in figure 4-41).
2) Insert the module into the slot along the rail and drive it ahead smoothly.
3) Push both levers toward the slot (refer to in figure 4-41).
Figure 4-41 RG-S8612E in the Chassis
If a slot is not inserted with a supervisor module, service module or switch fabric module, please cover the slot with a baffle for heat dissipation.
·
4.11 Connecting the Power Cord
Connect the power cord to the location as required according to the identification on the AC power module panel, including RG-PA1600I, RG-PA600I, RG-PA1600I-P, RG-PA1600I-PL and RG -PA3000I-PL.
Make sure the socket is powered off before the power cord is connected.
Connect the AC power cord
1) Insert the AC power plug into the power module socket.
2) Take out the anti-loose buckle.
3) Install the anti-loose buckle on the front panel of the power module
4) Fasten the anti-loose buckle to the power cord.
5) Connect the other end of the power cord to an external power socket.
Figure 4-42 Connecting the Power Cord
Please use the 3-pin power cord. The cross-sectional area of each pin is 1.5 mm2 or 14 AWG minimum. 16A and 10A power cords are available for the RG-S8605E, RG-S8607E, RG-S8610E and RG-S8612E AC power supply. Adopt
the proper socket and verify the AC power supply capacity in the machine room.
Connect the power cord to the DC power module (RG-PD1600I or RG-PD600I.) as required according to the identification on the
module panel.
1. Take out the DC power module and power cord. Insert the DC power into the power module slot.
2. Remove the screws on the grounding terminal of the DC power supply with the screwdriver.
3. Connect the DC power cords according to the instructions on the panel, which are green with yellow strip(ground wire), blue(-) and red(+) from left to right, as shown in the following figure.
4. Fasten the OT terminal of the DC power cord to the connecting terminal with the screwdriver.
Figure 4-43 Power Cord Instruction on Chassis
·
Before connecting the power supply, make sure the external power supply matches the power module installed. Before connecting the DC power cord to the terminal, make sure the other end of power cord is not plugged in.
Make sure the power supply is properly connected.
4.12 Installation Verification
Before you check the installation, please make sure that all power supplies have been turned off to avoid hurting you or the switch.
Before powering up the RG-S8600E, please verify the following items:
Verify that the fan meets the requirement. Please refer to RG-S8600E Series Hardware Installation and Reference Guide for
details.
Verify that the power supply is properly selected. Please refer to RG-S8600E Series Hardware Installation and Reference Guide
for details.
Verify that the power module is inserted properly and the screws are fastened tightly. Please dont power up the switch by yourself and dont perform live-line maintenance. Verify that there is no potential danger in the working area, for example, the power supply is not grounded well, or the ground is
wet.
Please do not place the switch at a damp place to prevent the moisture from entering the switch. Be sure of the location of the emergency power switch. If an emergency occurs, cut off the power first.
·
Verify that all power supplies are turned off if you want to turn off the power. Verify that the power cord is connected properly and wont be loosened. Verify that the power cord is long enough to avoid being stretched. Verify that the rated current of the external power socket is greater 16A and that the socket is grounded well. Verify that each power module is connected to a power socket. Verify that the vacant slot is covered with a baffle for ventilation and heat dissipation.
5 Logging in to the Switch
You can log in to the switch through the Console port.
Connecting Console Cables
1) Connect one end of the DB-9 jack of the console cable to the serial port of the PC or the terminal.
2) Connect one end of the console cable DB-9 to the console port on the switch fabric module.
Figure 5-1 Connecting the Switch to the PC through the Console Port
Powering-on and Checking
·
Make sure that the power cord is connected to the power supply, and the power supply is operational. The following table lists the operational conditions indicated by the module LEDs.
Module
LED Indicator
Status
Supervisor Module
Status
Solid green
Service Module
Status
Solid green
Switch Fabric Module
Status
Solid green
Power Supply
Status
Solid green
Fan
Status
Solid green
For the detailed description of LEDs, refer to RG-S8600E Series Switches Hardware Installation and Reference Guide.