Deep down cleaning on:
Carpets
Areas
Stairs Upholstery Vehicles
Y
E
A
R
G
E
E
T
N
A
U
R
A
Founded by a professional carpet cleaner in 1972,
the first machines were designed and built for
professional use. A brand was born and soon after, Rug
Doctor launched the first rental program that made
professional-grade carpet cleaning machines available
to the public. More than 40 years later, Rug Doctor has
grown to become a household name and continues as
the leader in carpet care rental systems with powerful
machines and innovative products.
3 Safety Instructions 4 Parts, Components 5 Tool Caddy Wrap System 6 Getting Ready To
Clean Carpets 7 Cleaning Carpets 10 Getting Ready To
Clean Upholstery etc. 11 Cleaning Upholstery etc. 14 Troubleshooting 15 Replacement Parts 16 Rug Doctor Solutions 18 Guarantee Information
2 1800 441 900 rugdoctor.com.au
Retain for your records: To s av e
time if calling Customer Service for information about your Rug Doctor® machine, it is recommended that you record your machine information below.
Serial #:
Model #:
Date of Purchase:
Rug Doctor LTD.
Unit 10/25-37 Chapman St,
Blackburn North, Vic, 3130
info@rugdoctor.com.au
www.rugdoctor.com.au
IMPORTANT SAFETY INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, INJURY OR PROPERTY DAMAGE:
Please read all instructions before using. When using an electrical appliance, basic precautions should always be followed, including the following:
SAVE THESE INSTRUCTIONS
6 To avoid scalding or burns, use caution when filling hand hot tap water into the clean water tank. Do not boil or microwave water to be used in machine.
6 Do not leave appliance unattended when plugged in or while it is on. Unplug from mains socket when not in use and before cleaning or servicing.
6 To reduce the risk of fire and electric shock due to internal component damage, use only Rug Doctor
See the Cleaning Product section of this manual. 6 Do not allow to be used as a toy. Not intended for use by children age 12 and under.
Close attention and adult supervision is necessary when used near children. Do not allow children to place their body parts in or near openings and moving parts.
6 Use only as described in this manual. Use only Rug Doctor’s recommended products. 6 Do not use with damaged cable or plug. If appliance is not working as it should, has
been dropped, damaged, left outdoors, or dropped into water, stop using and return it to Rug Doctor.
6 Do not pull or carry by cable, use cable as a handle, close a door on cable, or pull cable around sharp edges or corners. Do not run appliance over cable. Keep cable away from heated surfaces.
6 Do not unplug by pulling on cable. To unplug, grasp the plug, not the cable. 6 Do not handle plug or appliance with wet hands. 6 Do not put any object into openings. Do not use if any opening is blocked;
keep fr 6 Keep hair, loose clothing, fingers, and all parts of body away from openings and
moving parts.
6 6 Use extra care when cleaning on stairs. 6 Do not use to pick up flammable or combustible liquids or materials such as petrol,
solvents, paints or use in areas where they may be present. 6 Do not use to pick up anything that is burning or smoking, such as cigarettes,
matches, or hot ashes. 6 Do not place in or pick up caustic or toxic materials (Such as, bleach, ammonia, toilet
bowl cleaner and drain cleaners) with machine. 6 Use only on surfaces moistened by cleaning process or small spills. Do not place or
submerge machine in standing water or try to clear flooded areas.
6 Do not clean over floor electrical sockets. 6 The use of an extension cable is not recommended. Failure to follow the foregoing
instructions may expose the user to the possibility of electric shock, personal injury and/or death.
6 When clean water tank runs out stop using and follow instructions to refill. 6 Do not operate without tanks or in any manner inconsistent with above warnings or
the operating instructions set forth in this manual.
ee of dust, lint, hair, and anything that may reduce air flow.
®
cleaning products intended for use with this appliance.
rugdoctor.com.au 1800 441 900 3
bl
e
PRODUCT PARTS, COMPONENTS
Deep Clean Activation Button
Comfort
Grip
Handle
Cleaning mode selector / power switch
Quick release no tangle mains cable wrap
Main Carry Handle
Upholstery Tool Waste Port
Easy lift out WAST E water tank
Removable Tool
Brush Tool for
Flexible vacuum and
i
uti
solutions hoses for
compact storage
CLEAN Water
Rear Carry Handle -
use only when tanks
Caddy
Upholstery
stains, stairs
and versatile
cleaning
Easy lift out
Tank Handle
are empty
Rotating Grooming & Polishing Brush
CLEANING SOLUTION
• RUG DOCTOR CARPET DETERGENT WITH SPOTBLOK® STAIN REPELLENT.
Cleans, deodorises, rejuvenates and protects your carpets. Proven deep cleaning performance. Protects your carpets against future stains and spills. Wool friendly and pet safe.
• RUG DOCTOR CARPET ANTI-FOAM: Specially formulated to prevent suds build-up
in the recovery tank and improve the efficiency of the machine, ensuring optimal vacuum pressure.
Large, carpet friendly
wheels for extra
manoeuvrability
Vibrating Deep Cleaning Brush
4 1800 441 900 rugdoctor.com.au
HAND TOOL CADDY SYSTEM
Your RUG DOCTOR DEEP CARPET CLEANER has a HAND TOOL and REMOVABLE TOOL CADDY. Designed to easily
the machine handle, the HAND TOOL CADDY can hang on a hook or peg when not in use. Simply slide the TOOL CADDY
Complete Tool Caddy
Wrap System
To wrap the HAND TOOL around the HAND TOOL CADDY follow these 4 simple steps:
onto the back of the machine to store in one convenient and compact package.
12
Insert large connector with
hose pointing up into clips.
Wrap the tool hose clockwise around the caddy 3 times.
34
Insert the Hand Tool into place with the brush facing out. Secure the tool in place.
with the clips locking it
Finally, insert the small connector into the opening directly above the Hand Tool.
rugdoctor.com.au 1800 441 900
5
GETTING READY TO CLEAN CARPETS
Your RUG DOCTOR DEEP CARPET CLEANER is ready to start cleaning right out of the box. No assembly required! Follow these simple instructions to start cleaning.
1. Using the HANDLE RELEASE raise the handle to a comfortable position: It will click into the nearest locking position. You will need to keep the front nozzle in contact with the carpet at all times when pulling machine backwards. (Fig. 6).
(Fig 6)
2. Fill the CLEAN WATER TANK: a. Remove the CLEAN WATER TANK by
gripping the tank HANDLE and lifting straight up. (Fig. 7)
d. The TANK LID is also the “Carpet
Detergent” measure. Fill the lid with Rug Doctor cleaning solution to the desired level. For normally soiled carpets fill up to the 60ml mark. For heavily soiled carpets fill up to the 120ml mark (Fig. 8)
(Fig 8)
e. Pour the cleaning solution into the
CLEAN WATER TANK and replace the lid. Turn clockwise to tighten.
f. Place the CLEAN WATER TANK back in
the machine, making sure it is secure.
g. Check the black POWER SWITCH in the
handle to make sure it is in
the middle
(Fig 7)
b. Loosen the TANK LID by turning
anti-clockwise and remove from th machine, set aside.
c. Fill the tank with hand hot tap water
to the “CLEAN WATER FILL LINE”. Use luke warm water only on wool / wool mix carpets.
DO NOT USE BOILED OR MICROWAVED WATER IN TANK.
DO NOT USE BOILED OR MICROWAVED WATER IN TANK. Doing so could result in scalding or burns and damage to the machine. Not recommended for use on wool, jute, sisal carpets and rugs. Doing so could damage material and void guarantee on machine. Do not walk on wet carpet.
6 1800 441 900 rugdoctor.com.au
e
cleaning mode selector.
h. The MAINS POWER CABLE will come
wrapped and tied. Release the MAINS POWER CABLE and plug in to a mains socket.
i. NOTE: The machine was designed with
convenient rotating CABLE WRAP HOOKS to store the CABLE on board the machine. The CABLE WRAP HOOKS on the handle rotate to easily release the mains power cable.
Loading...