Rudd 22X40F1 User Manual

These units are designed to meet or exceed ANSI (American National Standards Institute) requirements and have been tested according to D.O.E. test procedures and meet or exceed the energy efficiency requirements of NAECA, ASHRAE standard 90, ICC Code and all state energy efficiency performance criteria for energy consuming appliances.
Before purchasing this appliance, read important energy cost and efficiency information available from your supplier.
E
BA
C
F
H
HOT
WATER
CONNECTION
H
COLD
WATER
CONNECTION
D
1/2"
3/4" N.P.T.
RELIEF
VALVE
OPENING
FLUE
ANODE ROD
Imperial Gas Water Heaters
Available in 38, 40 and 50 Gallon Tall – 40 Gallon Short Gas Models
10-Year* Limited Tank and Parts Warranty.
Guardian System
One-of-a-kind air/fuel shut-off device offers double protection
Maintenance free – no filter to clean
Standard replacement parts
Environmentally Friendly Burner
Low NOx design for low nitrous oxide emissions
Self-Cleaning
EverKleen™patented system fights sediment build-up
Reduces fuel costs
Provides more hot water
Easy to Light
No matches required
Energy Efficient
More hot water at low operating cost
High Altitude Compliant
All models are certified for applications up to 6,000 feet above sea level. Some models are certified up to 10,200 feet above sea level. Check factory for listings
Longer Life
Patented magnesium anode rod design incorporates a special resistor that protects the tank from rust
Plus…
Brass drain valve and temperature and pressure relief valve are included
Meets or exceeds National Appliance Energy Conservation Act (NAECA) requirements
Energy Factor and Average Annual Operating Costs based on D.O.E. (Department of Energy) test procedures. D.O.E. national average fuel rate natural gas 91¢/therm; LP $1.23/gallon.
Rheem Water Heating • 101 Bell Road, Montgomery, Alabama 36117-4305 • www.rheem.com
PRINTED IN U.S.A 05/06 WP FORM NO. 101-3 Rev. 4
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Guardian System Features…
Flame Arrestor Plate
A specially-designed flame arrestor prevents ignition of vapors outside the combustion chamber.
Maintenance Free
Superior air filtration prevents the flame arrestor from becoming clogged by lint, dust and oil.
Exclusive Combustion Shut-off System
Should a spill incident occur, the Guardian System shuts off the gas supply and the air supply preventing a sustained vapor burn in the combustion chamber.
40 42XR40-40F 40 34 40.4 34.3 68 63-1/4 59-5/8 21 14-1/2 3 8 53-1/2 3/4 135 0.62 $220
50 42XR50-40F 40 36 40.4 36.4 83 62-1/4 58-3/4 23 14-1/2 3 8 52-1/2 3/4 165 0.62 $220
38 42X40F 40 34 40.4 34.3 68 61-1/2 57-3/4 19-3/4 14-1/2 3 8 52-1/4 3/4 125 0.60 $227
40 22X40F1 38 38.4 73 61-3/4 58-3/8 18-1/8 14-1/2 3 8 52-1/4 3/4 120 0.59 $231
50 22X50F1 38 38.4 90 61-1/2 58-1/4 20-1/8 14-1/2 3 8 51-3/8 3/4 130 0.58 $235
50 42X50-40F 40 36 40.4 36.4 82 61-1/2 58 21-3/4 14-1/2 3 8 52-1/2 3/4 150 0.58 $235
40 22X40SF 36 34 36.4 34.3 72 52-3/4 49-3/8 20-1/8 14-1/2 3 8 42-3/4 3/4 130 0.59 $231
40 42X40SF 40 36 40.4 36.4 72 53-7/8 50-1/2 20-1/8 14-1/2 3 8 44 3/4 130 0.59 $231
T Y P E
H E
TALL
SHORT
TALL
DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFO.
HT.TO WATER HT. TO
GAS INPUT IN RECOVERY IN FIRST HOUR HT.TO TANK GAS VENT CONN. SIDE WATER SHIP. ENERGY AVG. ANN. GAL. THOUS. BTU/HR. G.P.H. 90° RISE DEL. G.P.H. VENT HT. DIAM. CONN. SIZE CNTR. T&P CONN. WT. FACTOR OPER. COST CAP. MODEL NUMBER NAT. LP NAT. LP NAT. A B C D E F G H (LBS) NAT. NAT.
H E
High Efficiency Models Feature:
High performance and lower operating cost
Compliant with many gas utility incentive programs
*See Residential Warranty Information Brochure
for complete warranty information.
For SCAQMD rule 1121 compliance models (California only), add SQsuffix to the model number. Example: 42XR40-40FSQ.
®