Warrior Gas Water Heater for Manufactured Housing now with the Guardian System
E
G
BA
C
F
HOT
WATER
CONNECTION
D
1/2"
3/4" N.P. T.
RELIEF
VALVE
OPENING
FLUE
3/4" N.P.T.
ANODE ROD
20-1/8"
COLD
WATER
CONN.
3/4"
N.P.T.
™
Available in 30, 40 and 50 Gallon Tall Gas Models
5-Year Limited Tank Warranty*1-Year Limited Parts Warranty*
Guardian System
One-of-a-kind air/fuel shut-off device offers double
•
protection
aintenance free – no filter to clean
M
•
Standard replacement parts
•
Environmentally Friendly Burner
Low NOx design for low nitrous oxide emissions
•
Standard Features:
Optional base kits for replacement of
•
pre-FVIR units
Side inlet temperature and pressure relief valve
•
opening
Two hole top for anode rod and hot
•
water outlet
Factory installed temperature and pressure
•
relief valve – side location
ESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFORMATION
D
T
Y
GAL. THOUS. BTU/HR. G.P.H. 90° RISE DEL. G.P.H. VENT HT. DIAM. CONN. SIZE CNTR. T&P. WT. ENERGY OPER. COSTS
P
E
AP. MODEL NUMBER NAT. LP NAT. LP NAT. LP AB C DEFG(LBS) FACTOR NAT. LP
C
30 22V30FT 32 30 32.3 30.3 48 – 59-3/4 56-3/8 16-1/8 14-1/2 3850-3/4 100 0.61 $299 $503
T
A
40 22V40FT 34 32 34.3 32.3 59 – 61-3/4 58-3/8 18-1/8 14-1/2 3851-3/8 120 0.59 $309 $520
L
L
50 22V50FT 38 36 38.4 36.4 65 – 61-1/2 58-1/4 20-1/8 14-1/2 3851-3/8 130 0.58 $315 $529
Note: For 1 year tank warranty, substitute “I” for “V” in model number. Example: 22I40FT.
GAS INPUT IN RECOVERY IN FIRST HOUR HT.TO TANK GAS VENT CONN. SIDE SHIP. AVG. ANN.
™
Altitude certification up to 6,000 ft. above sea
•
level. High altitude models available
Exclusive Rheemglas®tank lining resists
•
orrosion and prolongs tank life
c
Patented R-Foam®insulation process
•
for superior heat retention
Piezo ignitor – easy light pilot, no matches
•
required
Anode rod equalizes aggressive water action
•
Cold water inlet – side connection allows for
•
quick, economical hook-up
Optional leg kit for replacement units
•
*See Residential Warranty Information Brochure for complete
warranty information.
Energy Factor and Average Annual Operating
Costs based on D.O.E. (Department of Energy)
test procedures. D.O.E. national average fuel rate
natural gas $1.218/therm; LP $1.87/gallon
HT.TO WATER HT.TO
.
Rheem Guardian System Features…
Exclusive Combustion
Shut-off System
Should a spill incident occur, the
Guardian System shuts off the gas
supply and the air supply preventing
a sustained vapor burn in the
combustion chamber.
These units are designed to
meet or exceed ANSI
(American National Standards
Institute) requirements and
have been tested according to
D.O.E. test procedures and
meet or exceed the energy
efficiency requirements of
NAECA II, ASHRAE standard
90, ICC Code and all state
energy efficiency performance
criteria for energy consuming
appliances.
Before purchasing this
appliance, read important
energy cost and efficiency
information available from
your supplier.
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Water Heating • 101 Bell Road • Montgomery, Alabama 36117-4305 • www.rheem.com
P R I N T E D I N U . S . A 0 8 / 0 8 W P F O R M N O . 1 0 2 G W- 7 R ev . 5
Flame Arrestor Plate
A specially-designed flame
arrestor prevents ignition of
vapors outside the combustion
chamber.
Maintenance Free
Superior air filtration prevents the
flame arrestor from becoming
clogged by lint, dust and oil.
Draft Diverter
Improved design
provides efficient
heating with
down-draft
protection.
THE WARRIOR IS C.S.A.
CERTIFIED FOR MANUFACTURED
HOME USE, MEETS ANSI
STANDARDS FOR MODULAR
HOME CONSTRUCTION, AND
COMPLIES WITH HUD SAFETY
AND CONSTRUCTION
STANDARDS.