Rudd 22V30FT User Manual

Warrior Gas Water Heater for Manufactured Housing now with the Guardian System
E
G
BA
C
F
HOT
WATER
CONNECTION
D
1/2"
3/4" N.P. T.
RELIEF
VALVE
OPENING
FLUE
3/4" N.P.T.
ANODE ROD
20-1/8"
COLD
WATER
CONN.
3/4"
N.P.T.
®
Available in 30, 40 and 50 Gallon Tall Gas Models
5-Year Limited Tank Warranty*1-Year Limited Parts Warranty*
Guardian System
One-of-a-kind air/fuel shut-off device offers double
protection
aintenance free – no filter to clean
M
Standard replacement parts
Environmentally Friendly Burner
Low NOx design for low nitrous oxide emissions
Standard Features:
Optional base kits for replacement of
pre-FVIR units Side inlet temperature and pressure relief valve
opening Two hole top for anode rod and hot
water outlet Factory installed temperature and pressure
relief valve – side location
ESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFORMATION
D
T
Y
GAL. THOUS. BTU/HR. G.P.H. 90° RISE DEL. G.P.H. VENT HT. DIAM. CONN. SIZE CNTR. T&P. WT. ENERGY OPER. COSTS
P E
AP. MODEL NUMBER NAT. LP NAT. LP NAT. LP AB C DEFG(LBS) FACTOR NAT. LP
C
30 22V30FT 32 30 32.3 30.3 48 59-3/4 56-3/8 16-1/8 14-1/2 3850-3/4 100 0.61 $299 $503
T A
40 22V40FT 34 32 34.3 32.3 59 61-3/4 58-3/8 18-1/8 14-1/2 3851-3/8 120 0.59 $309 $520
L L
50 22V50FT 38 36 38.4 36.4 65 61-1/2 58-1/4 20-1/8 14-1/2 3851-3/8 130 0.58 $315 $529
Note: For 1 year tank warranty, substitute “I” for “V” in model number. Example: 22I40FT.
GAS INPUT IN RECOVERY IN FIRST HOUR HT.TO TANK GAS VENT CONN. SIDE SHIP. AVG. ANN.
Altitude certification up to 6,000 ft. above sea
level. High altitude models available Exclusive Rheemglas®tank lining resists
orrosion and prolongs tank life
c Patented R-Foam®insulation process
for superior heat retention Piezo ignitor – easy light pilot, no matches
required Anode rod equalizes aggressive water action
Cold water inlet – side connection allows for
quick, economical hook-up Optional leg kit for replacement units
*See Residential Warranty Information Brochure for complete
warranty information.
Energy Factor and Average Annual Operating Costs based on D.O.E. (Department of Energy) test procedures. D.O.E. national average fuel rate natural gas $1.218/therm; LP $1.87/gallon
HT.TO WATER HT.TO
.
Rheem Guardian System Features…
Exclusive Combustion Shut-off System
Should a spill incident occur, the Guardian System shuts off the gas supply and the air supply preventing a sustained vapor burn in the combustion chamber.
These units are designed to meet or exceed ANSI (American National Standards Institute) requirements and have been tested according to D.O.E. test procedures and meet or exceed the energy efficiency requirements of NAECA II, ASHRAE standard 90, ICC Code and all state energy efficiency performance criteria for energy consuming appliances.
Before purchasing this appliance, read important energy cost and efficiency information available from your supplier.
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Water Heating • 101 Bell Road • Montgomery, Alabama 36117-4305 • www.rheem.com
P R I N T E D I N U . S . A 0 8 / 0 8 W P F O R M N O . 1 0 2 G W- 7 R ev . 5
Flame Arrestor Plate
A specially-designed flame arrestor prevents ignition of vapors outside the combustion chamber.
Maintenance Free
Superior air filtration prevents the flame arrestor from becoming clogged by lint, dust and oil.
Draft Diverter
Improved design provides efficient heating with down-draft protection.
THE WARRIOR IS C.S.A.
CERTIFIED FOR MANUFACTURED
HOME USE, MEETS ANSI STANDARDS FOR MODULAR HOME CONSTRUCTION, AND
COMPLIES WITH HUD SAFETY
AND CONSTRUCTION
STANDARDS.
Loading...