G
E
A
B
C
F
D
10"
3/4" N.P. T.
RELIEF VALVE
OPENING
1/2"
EXTERIOR
WALL
(G:
SIDE VENTING
RANGE OF
ADJUSTMENT)
Fury DV Rheemglas
HOT WATER
CONNECTION
COLD WATER
CONNECTION
®
Energy Miser®Direct Vent Gas Water Heaters now with the Guardian System
LONGER VENTING AVAILABLE
Available in 40 and 50 Gallon Tall Gas Models
NEW FVIR Compliant!
NEW LP Models Available!
6-Year Limited Tank and Parts Warranty*
With ProtectionPlus™the 6-Year Limited Tank Warranty Becomes 10 Years!
™
Adjustable coaxial vent allows flexibility
•
f installation – uses outside air for combustion
Get
4 MORE YEARS
with ProtectionPlus
™
o
and requires no electrical power
Aluminum vent and cap base to prevent
•
staining of building exterior
Brass drain valve
•
Factory installed temperature and pressure
•
relief valve
R-Foam®insulation for superior heat retention
•
Exclusive Rheemglas®tank lining resists
•
corrosion and prolongs tank life
Heat saving flue baffle design
•
Gas control and combination thermostat
•
Piezo ignition
•
ESCRIPTION FEATURES DIMENSIONS ENERGY INFO.
D
T
Y
GAL. MODEL THOUS. BTU/HR. G.P.H. 90° RISE DEL. G.P.H. VENT HT. DIAMETER GAS CONN. SIZE SIDE T&P WT.
P
CAP. NUMBER
E
40 22DV40F 38 30 38.4 30.3 66 64 68-1/4 59-3/4 19-3/4 14-1/4 6 51-5/8 155 2,000* 7,700 0.59 $231
TALL
50 22DV50F 38 34 38.4 34.3 80 79 68 59-1/2 21-3/4 14-1/4 6 52-1/2 165 6,000 6,000 0.58 $235
• Specify LP gas when ordering. Add “PF” suffix to the model number. Example 22DV40PF
VENTING – ROUGHING IN DIMENSIONS (INCHES)
TYPE NUMBER AVAILABLE
TALL
SCAQMD rule 1121 compliant
* High altitude model available upon request: 22DV40HF
** Horizontal Vent Kit #SP20131. Venting dimensions are approximate.
† Vertical Vent Kit #SP20132. Venting dimensions are approximate.
• If side wall is combustible material, 1" clearance must be included in adjustment range.
MODEL 4 FEET VENTING OPTIONAL HEIGHT (A)
22DV40F
22DV50F
AS INPUT IN RECOVERY IN FIRST HOUR HT. TO TANK HT.TO VENT HT. TO SHIP. UP TO “X” FEET ENERGY AVG. ANN.
G
NAT. LP NAT. LP NAT. LP
SIDE VENTING (G)
WITH INCLUDED
VENT KIT
MIN. MAX. MIN. MAX.
Horizontal
& Vertical
9-1/8 19-1/8 9-1/8 48** 68-1/4 – 107-3/4†
8-1/8 18-1/8 8-1/8 48** 68 – 107†
AB C DEF(LBS)
SIDE VENTING (G)
WITH OPTIONAL
VENT KIT
WITH VENT KIT
Patented magnesium anode rod design
•
ncorporates a special resistor that protects
i
the tank from corrosion
High temperature silicone bands reduce venting
•
installation time
Internal air tube for reduced footprint
•
Meets ANSI Z21.10.1 requirements for
•
Flammable Vapor Ignition Resistance (FVIR)
Meets or exceeds National Appliance Energy
•
Conservation Act (NAECA) requirements
* See Residential Warranty Information Brochure for complete
arranty information.
w
nergy Factor and Average Annual Operating Costs based on D.O.E.
E
Department of Energy) test procedures.D.O.E. national average fuel rate
(
atural gas 91¢/therm; LP $1.23/gallon.
n
ALTITUDE
RATING
ABOVE SEA LEVEL
NAT. LP NAT. NAT.
FACTOR OPER. COSTS
These units are designed
to meet or exceed ANSI
(American National
Standards Institute)
requirements and have been
tested according to D.O.E.
test procedures and meet or
exceed the energy efficiency
requirements of NAECA,
ASHRAE standard 90, ICC
Code and all state energy
efficiency performance
criteria for energy consuming
appliances.
Before purchasing this
appliance, read important
energy cost and efficiency
information available from
your supplier.
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Water Heating • 101 Bell Road, Montgomery, Alabama 36117-4305 • www.rheem.com
P R I N T E D I N U. S.A 1 0 / 0 7 W P F O R M N O . 1 0 1 - 2 2 R e v. 1 9
NEW LONGER VENTING!
• Up to 4 feet above the water heater
and 4 feet from an outside wall.
Order Horizontal Vent Kit:
Rheem Exclusive Adjustable
Coaxial Vent Allows Flexibility
of Installation…
You may orient the Fury DV
for easiest service
access, because the
adjustable coaxial
vent can swivel
360 degrees.
#SP20131
Order Vertical Vent Kit:
#SP20132