Rudd 22DV50F User Manual

G
E
A
B
C
F
D
10"
3/4" N.P. T.
RELIEF VALVE
OPENING
1/2"
EXTERIOR
WALL
(G:
SIDE VENTING
RANGE OF
ADJUSTMENT)
Fury DV Rheemglas
®
HOT WATER CONNECTION
COLD WATER CONNECTION
®
Energy Miser®Direct Vent Gas Water Heaters now with the Guardian System
LONGER VENTING AVAILABLE
Available in 40 and 50 Gallon Tall Gas Models
NEW FVIR Compliant!
NEW LP Models Available!
6-Year Limited Tank and Parts Warranty*
With ProtectionPlus™the 6-Year Limited Tank Warranty Becomes 10 Years!
Adjustable coaxial vent allows flexibility
f installation – uses outside air for combustion
Get
4 MORE YEARS
with ProtectionPlus
o and requires no electrical power Aluminum vent and cap base to prevent
staining of building exterior Brass drain valve
Factory installed temperature and pressure
relief valve R-Foam®insulation for superior heat retention
Exclusive Rheemglas®tank lining resists
corrosion and prolongs tank life Heat saving flue baffle design
Gas control and combination thermostat
Piezo ignition
ESCRIPTION FEATURES DIMENSIONS ENERGY INFO.
D
T Y
GAL. MODEL THOUS. BTU/HR. G.P.H. 90° RISE DEL. G.P.H. VENT HT. DIAMETER GAS CONN. SIZE SIDE T&P WT.
P
CAP. NUMBER
E
40 22DV40F 38 30 38.4 30.3 66 64 68-1/4 59-3/4 19-3/4 14-1/4 6 51-5/8 155 2,000* 7,700 0.59 $231
TALL
50 22DV50F 38 34 38.4 34.3 80 79 68 59-1/2 21-3/4 14-1/4 6 52-1/2 165 6,000 6,000 0.58 $235
• Specify LP gas when ordering. Add “PF” suffix to the model number. Example 22DV40PF
VENTING – ROUGHING IN DIMENSIONS (INCHES)
TYPE NUMBER AVAILABLE
TALL
SCAQMD rule 1121 compliant * High altitude model available upon request: 22DV40HF ** Horizontal Vent Kit #SP20131. Venting dimensions are approximate. † Vertical Vent Kit #SP20132. Venting dimensions are approximate.
• If side wall is combustible material, 1" clearance must be included in adjustment range.
MODEL 4 FEET VENTING OPTIONAL HEIGHT (A)
22DV40F 22DV50F
AS INPUT IN RECOVERY IN FIRST HOUR HT. TO TANK HT.TO VENT HT. TO SHIP. UP TO “X” FEET ENERGY AVG. ANN.
G
NAT. LP NAT. LP NAT. LP
SIDE VENTING (G)
WITH INCLUDED
VENT KIT
MIN. MAX. MIN. MAX.
Horizontal
& Vertical
9-1/8 19-1/8 9-1/8 48** 68-1/4 – 107-3/4† 8-1/8 18-1/8 8-1/8 48** 68 – 107†
AB C DEF(LBS)
SIDE VENTING (G)
WITH OPTIONAL
VENT KIT
WITH VENT KIT
Patented magnesium anode rod design
ncorporates a special resistor that protects
i the tank from corrosion High temperature silicone bands reduce venting
installation time Internal air tube for reduced footprint
Meets ANSI Z21.10.1 requirements for
Flammable Vapor Ignition Resistance (FVIR) Meets or exceeds National Appliance Energy
Conservation Act (NAECA) requirements
* See Residential Warranty Information Brochure for complete
arranty information.
w
nergy Factor and Average Annual Operating Costs based on D.O.E.
E
Department of Energy) test procedures.D.O.E. national average fuel rate
(
atural gas 91¢/therm; LP $1.23/gallon.
n
ALTITUDE
RATING
ABOVE SEA LEVEL
NAT. LP NAT. NAT.
FACTOR OPER. COSTS
These units are designed to meet or exceed ANSI (American National Standards Institute) requirements and have been tested according to D.O.E. test procedures and meet or exceed the energy efficiency requirements of NAECA, ASHRAE standard 90, ICC Code and all state energy efficiency performance criteria for energy consuming appliances.
Before purchasing this appliance, read important energy cost and efficiency information available from your supplier.
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Water Heating • 101 Bell Road, Montgomery, Alabama 36117-4305 • www.rheem.com
P R I N T E D I N U. S.A 1 0 / 0 7 W P F O R M N O . 1 0 1 - 2 2 R e v. 1 9
NEW LONGER VENTING!
• Up to 4 feet above the water heater and 4 feet from an outside wall.
Order Horizontal Vent Kit:
Rheem Exclusive Adjustable Coaxial Vent Allows Flexibility of Installation…
You may orient the Fury DV for easiest service access, because the adjustable coaxial vent can swivel 360 degrees.
#SP20131
Order Vertical Vent Kit:
#SP20132
Loading...