Fury DV (Vertical Vent Option) Direct Vent Gas Water Heaters
Roof Jack
(Purchased Separately)
Roof Jack
Adjustment Range
12"
Min
FRONT VIEW
A
B
C
X
E
D
ADJUSTABLETILT
ROOF FLANGE
34° MAX.
(8 - 12 PITCH)
42° MAX. TILT IS
AVAI LABLE WITH
OPTIONAL KIT
(10-3/4 - 12 PITCH)
Available in 40 and 50 Gallon Tall Gas Models
FVIR Compliant!
LP Models Available!
6-Year Limited Tank and Parts Warranty*
With ProtectionPlus™the 6-Year LimitedTank Warranty Becomes 10Years!
Get
4 MORE YEARS
with ProtectionPlus
Adjustable coaxial vent kits allow flexibility
•
of installation – uses outside air for combustion
and requires no electrical power
Brass drain valve
•
Factory installed temperature and pressure
•
relief valve
R-Foam®insulation for superior heat retention
•
™
Exclusive Rheemglas®tank lining resists
•
Internal air tube for reduced footprint
•
Meets ANSI Z21.10.1 requirements for
•
Flammable Vapor Ignition Resistance (FVIR)
Meets or exceeds National Appliance Energy
•
Conservation Act (NAECA) requirements
See Residential Warranty Information Brochure for complete
*
arranty information.
w
corrosion and prolongs tank life
Heat saving flue baffle design
•
Gas control and combination thermostat
•
Piezo ignition
•
Patented magnesium anode rod design
•
incorporates a special resistor that protects
the tank from corrosion
ESCRIPTION FEATURES DIMENSIONS ENERGY INFO.
D
T
Y
GAL. MODEL THOUS. BTU/HR. G.P.H. 90° RISE DEL. G.P.H. DIAMETER HT. SIZE GAS CONN. SIDE T&P WT.
P
CAP. NUMBER
E
40 22DV40F-VX 36 30 36.4 30.3 66 65 19-3/4 59-3/4 5 14-1/4 51-5/8 155 7,700 7,700 0.59 $309
TALL
50 22DV50F-VX 36 32 36.4 32.3 80 80 21-3/4 59-1/2 5 14-1/4 52-1/2 165 7,700 7,700 0.59 $309
• Specify LP gas when ordering. Add “PF” suffix to the model number. Example 22DV40PF-VX
AS INPUT IN RECOVERY IN FIRST HOUR TANK VENT HT.TO HT.TO SHIP. UP TO “X” FEET ENERGY AVG. ANN.
G
NAT. LP NAT. LP NAT. LP
ABCD E(LBS)
Energy Factor and Average Annual
Operating Costs based on D.O.E.
(Department of Energy) test procedures.
D.O.E. national average fuel rate natural
gas $1.218/therm; LP $1.87/gallon
.
ALTITUDE
RATING
ABOVE SEALEVEL
NAT. LP NAT. NAT.
FACTOR OPER. COSTS
These units are designed
to meet or exceed ANSI
(American National
Standards Institute)
requirements and have
been tested according to
D.O.E. test procedures and
meet or exceed the energy
efficiency requirements of
NAECA, ASHRAE standard
90, ICC Code and all state
energy efficiency performance criteria for energy
consuming appliances.
Before purchasing this
appliance, read important
energy cost and efficiency
information available from
your supplier.
THESE UNITS CAN ONLY BE INSTALLED
WITH THE ROOF JACKS LISTED BELOW.
CO-AXIAL ROOF JACK SIZING TABLE
34° MAX. (8 – 12 42° MAX. (10-3/4 – 12 ROOF JACK
PITCH) ROOF JACK PITCH) ROOF JACK ADJUSTMENT
KIT PART NUMBER KIT PART NUMBER RANGE (SEE X)
AP14363A AP14334A 24 - 37 Inches
AP14363B AP14334B 33 - 68 Inches
AP14363C AP14334C 45 - 97 Inches
AP14363D AP14334D 60 - 130 Inches
AP14363E AP14334E 72 - 160 Inches
Roof Jacks must be ordered separately with this direct
vent water heater and installed in accordance with the
instructions furnished with the heater. No other roof jack or
vertical vent kit is approved for installation with this heater.
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.