Fury DV (Vertical Vent Option) Direct Vent Gas Water Heaters
®
Roof Jack
(Purchased Separately)
Roof Jack
Adjustment Range
12"
Min
FRONT VIEW
A
B
C
X
E
D
ADJUSTABLETILT ROOF FLANGE
34° MAX. (8 - 12 PITCH)
42° MAX. TILT IS AVAI LABLE WITH OPTIONAL KIT (10-3/4 - 12 PITCH)
Available in 40 and 50 Gallon Tall Gas Models
FVIR Compliant!
LP Models Available!
With ProtectionPlus™the 6-Year LimitedTank Warranty Becomes 10Years!
Get
4 MORE YEARS
with ProtectionPlus
Adjustable coaxial vent kits allow flexibility
of installation – uses outside air for combustion and requires no electrical power
Brass drain valve
Factory installed temperature and pressure
relief valve R-Foam®insulation for superior heat retention
Exclusive Rheemglas®tank lining resists
Internal air tube for reduced footprint
Meets ANSI Z21.10.1 requirements for
Flammable Vapor Ignition Resistance (FVIR) Meets or exceeds National Appliance Energy
Conservation Act (NAECA) requirements
See Residential Warranty Information Brochure for complete
*
arranty information.
w
corrosion and prolongs tank life Heat saving flue baffle design
Gas control and combination thermostat
Piezo ignition
Patented magnesium anode rod design
incorporates a special resistor that protects the tank from corrosion
ESCRIPTION FEATURES DIMENSIONS ENERGY INFO.
D
T Y
GAL. MODEL THOUS. BTU/HR. G.P.H. 90° RISE DEL. G.P.H. DIAMETER HT. SIZE GAS CONN. SIDE T&P WT.
P
CAP. NUMBER
E
40 22DV40F-VX 36 30 36.4 30.3 66 65 19-3/4 59-3/4 5 14-1/4 51-5/8 155 7,700 7,700 0.59 $309
TALL
50 22DV50F-VX 36 32 36.4 32.3 80 80 21-3/4 59-1/2 5 14-1/4 52-1/2 165 7,700 7,700 0.59 $309
• Specify LP gas when ordering. Add “PF” suffix to the model number. Example 22DV40PF-VX
AS INPUT IN RECOVERY IN FIRST HOUR TANK VENT HT.TO HT.TO SHIP. UP TO “X” FEET ENERGY AVG. ANN.
G
NAT. LP NAT. LP NAT. LP
ABCD E(LBS)
Energy Factor and Average Annual Operating Costs based on D.O.E. (Department of Energy) test procedures. D.O.E. national average fuel rate natural gas $1.218/therm; LP $1.87/gallon
.
ALTITUDE
RATING
ABOVE SEALEVEL
NAT. LP NAT. NAT.
FACTOR OPER. COSTS
These units are designed to meet or exceed ANSI (American National Standards Institute) requirements and have been tested according to D.O.E. test procedures and meet or exceed the energy efficiency requirements of NAECA, ASHRAE standard 90, ICC Code and all state energy efficiency perfor­mance criteria for energy consuming appliances.
Before purchasing this appliance, read important energy cost and efficiency information available from your supplier.
THESE UNITS CAN ONLY BE INSTALLED
WITH THE ROOF JACKS LISTED BELOW.
CO-AXIAL ROOF JACK SIZING TABLE
34° MAX. (8 – 12 42° MAX. (10-3/4 – 12 ROOF JACK PITCH) ROOF JACK PITCH) ROOF JACK ADJUSTMENT
KIT PART NUMBER KIT PART NUMBER RANGE (SEE X)
AP14363A AP14334A 24 - 37 Inches
AP14363B AP14334B 33 - 68 Inches
AP14363C AP14334C 45 - 97 Inches
AP14363D AP14334D 60 - 130 Inches
AP14363E AP14334E 72 - 160 Inches
Roof Jacks must be ordered separately with this direct vent water heater and installed in accordance with the instructions furnished with the heater. No other roof jack or vertical vent kit is approved for installation with this heater.
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
P R I N T E D I N U. S.A 0 3 / 0 9 W P F O R M N O . 1 0 2 - 4 5