Rudd 21VR30DV User Manual

G
2"
1/2"
RELIEF
VALVE
COLD
WATER
CONN.
ADJUSTS TO PITCHES
OF UP TO 5/12"
WATER CONNECTIONS
ALL 3/4" N.P.T.
H
D
E
C
F
A B
24" MIN.
0" MIN.
WALL
CLEARANCE
Warrior DVThe Direct Vent Gas Water Heater for Manufactured Housing
®
Available in 30, 40 and 50 Gallon Models
5-Year Limited Tank Warranty*1-Year Limited Parts Warranty*
No external vented door is required
All combustion air comes from outside the
home Provides maximum design freedom since it
can be placed anywhere within the home Hot water outlet located at top
Factory installed temperature and pressure
Peizo ignitor – easy light pilot
Certified for manufactured (HUD) and
modular construction Anode rod equalizes aggressive water
action Cold water inlet – side connection allows
for fast, economical hook-up relief valve – side location. Exclusive Rheemglas®tank lining resists
corrosion and prolongs tank life Field convertable controls for natural gas or
*See Residential Warranty Information Brochure for
complete warranty information.
LP operation Meets or exceeds National Appliance
Energy Conservation Act (NAECA) requirements
ESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFORMATION
D
T
Y
GAL. THOUS. BTU/HR. G.P.H. 90° RISE DEL. G.P.H. VENT HT. DIAM. CONN. SIZE VENT SZ. T&P CONN. WT. FACTOR OPER. COSTS
P E
AP. MODEL NUMBER NAT/ LP NAT./LP NAT./ LP AB C DEFGH(LBS) NAT./LP NAT. LP
C
30 21VR30DV 30 30.3 51 57 57 17-3/4 14-1/2 3551-1/2 20 110 0.61 $299 $503
T A
40 21VR40DV 30 30.3 60 57-1/2 57-1/2 19-3/4 14-1/2 3551-1/2 20 125 0.59 $309 $520
L L
50 21VR50DV 32 32.3 67 57 57 21-3/4 14-1/2 3551-1/2 20 150 0.58 $315 $529
GAS INPUT IN RECOVERY IN FIRST HOUR HT.TO TANK GAS VENT JACK SIDE WATER SHIP. ENERGY AVG. ANN.
Energy Factor and Average Annual Operating Costs based on D.O.E. (Department of Energy) test procedures. D.O.E.national average fuel rate natural gas $1.218/therm; LP $1.87/gallon
HT.TO ROOF HT.TO
.
These units are designed to meet or exceed ANSI (American National Standards Institute) requirements and have been tested according to D.O.E. test procedures and meet or exceed the energy efficiency requirements of NAECA, ASHRAE standard 90, ICC Code and all state energy efficiency perfor­mance criteria for energy consuming appliances.
Before purchasing this appliance, read important energy cost and efficiency information available from your supplier.
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Water Heaters • 101 Bell Road, Montgomery, Alabama 36117-4305 • www.rheem.com
P R INTE D I N U . S .A 0 7 /08 WP F O RM N O . 1 0 2 GW- 9 Re v. 4
Adjustable Roof Jack Vent
Design allows adjustment to roof pitches of up to 5/12". Four roof jacks available to accommodate roof thickness of 12" up to 95".
Direct Combustion Air Inlet
Air is drawn directly into combustion chamber through air inlet fixed to base; 1/2" screen for rodent protection.
ROOF JACKS
12" Non Adjustable & Air Inlet AP12032E 15-32" Adjustable & Air Inlet AP12032B 30-60" Adjustable & Air Inlet AP12032C 48-95" Adjustable & Air Inlet AP12032D
AIR INLETS
6" Non Adjustable AP12019B 11-22" Adustable AP12017B
EXTENSION PIPE KIT
Roof Jack Extension Pipe Kit AP12021
• Roof jack and air inlet must be ordered separately with 30, 40 and 50 gallon direct vent models and must be in accordance with instructions furnished with the heater. No other roof jack or air inlet assemblies are approved for installation with this heater. Clamps and secure strapping are packed in water heater carton.
THE WARRIOR DV IS U.L. CERTIFIED FOR
MANUFACTURED HOME USE, MEETS
ANSI STANDARDS FOR MODULAR HOME
CONSTRUCTION, AND COMPLIES WITH HUD SAFETY AND CONSTRUCTION STANDARDS.
*FOUR ROOF
JACKS AVAILABLE TO ACCOMMODATE ROOF THICKNESS OF 12" UP TO 95"