Rudd 15PJL-24 Installation Manual

Page 1
“Visit www.Rheem.com
for complete details.”
FORM NO. P11-789 REV. 1
Supersedes Form No. P11-789
Features
35" Maximum Unit Height.
Coils constructed with copper tubing and enhanced alu-
Strong, attractive cabinet—louvered design protects the
coil from damage.
Expansion Valves with Internal Check Valve—Provides
for quieter refrigerant metering.
Enhanced Demand Defrost Control
Factory Installed Low Pressure Control
Non-Cycling Reversing Valve
Hot Gas Muffler
Service Valves
Grille/motor mount for quiet fan operation.
Easily accessible control box.
Bi-Directional Filter Drier (Field Installed)
Certified and rated under AHRI Standard 240.
U.L listed.
Optional High Pressure Control (Field-Installed: 1.5-4 ton/
Factory Installed: 5 ton only)
Heat Pump Thermostat Warning Light Kit
Accessories/Options
Low Ambient Control (Model No. RXAD-A08)
Outdoor Thermostats (Model No. RXPT-A01, A02,
A03 or A04)
Heat Pump Monitor (Model No. RXPM-B01)
Thermostats and Subbases
(Available through the PROSTOCK®department)
Compressor Time Delay Control (Model No.
RXMD-B01)
Blower Time Delay Control (Model No. RXMD-C04)
RXMD-C04 is not required if the outdoor unit is matched with a Rheem Value Series furnace or air handler, or if the furnace or air handler used has a blower off time delay built-in.
Sound Enclosure*
Start Components*
*Available through the PROSTOCK
®
department.
Applications
Rheem Value Series remote heat pumps offer comfort and depend ability for single, multi-family and light commercial applications.
15 SEER
HEAT PUMPS
15PJL SERIES
Featuring New Industry Standard R-410A Refrigerant
(IN CERTAIN
MATCHED SYSTEMS)
Page 2
Model Numbers
AHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)
80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Outdoor Air
47°F [8.5°C] DB/
43°F [6°C] WB
DOE High Temp.
Outdoor Air 17°F [–8.5°C] DB/ 15°F [–9.5°C] WB
DOE Low Temp.
DOE
Region
IV
HSPF
Outdoor
Unit
15PJL
Indoor Coil and/or Air Handler
Tot al
Capacity
BTU/H
[kW]
Net
Sens.
BTU/H
[kW]
Net Latent BTU/H
[kW]
EER SEER
Snd. Rate
dB
Indoor
CFM [L/s]
BTU/H
[kW]
COP
BTU/H
[kW]
COP
18
RHLL-HM2417 (RCSL-H*2417)
18,500
[5.4]
13,400
[3.9]
5,100
[1.5]
12.50 15.00 76
600
[283]
17,700
[5.2]
3.68
10,800
[3.2]
2.38 8.50
RHBL-FR24T
19,600
[5.7]
14,900
[4.4]
4,700
[1.4]
12.50 15.00 76
600
[283]
16,500
[4.8]
3.48
9,500
[2.8]
2.04 8.20
RCFL-H*2414
18,200
[5.3]
13,100
[3.8]
5,100
[1.5]
11.50 13.50 76
600
[283]
18,200
[5.3]
3.42
11,300
[3.3]
2.24 7.70
RCFL-H*2417
18,200
[5.3]
13,100
[3.8]
5,100
[1.5]
11.00 13.50 76
600
[283]
18,200
[5.3]
3.42
11,300
[3.3]
2.24 7.70
RCFL-H*2417 (RGFD-06?MCK?)
18,400
[5.4]
13,350
[3.9]
5,050
[1.5]
12.50 15.00 76
600
[283]
17,800
[5.2]
3.64
10,900
[3.2]
2.36 8.20
RCFL-H*2417 (RGFD-07?MCK?)
18,400
[5.4]
13,350
[3.9]
5,050
[1.5]
12.50 15.00 76
600
[283]
17,800
[5.2]
3.64
10,900
[3.2]
2.36 8.20
RCFL-H*2417 (RGFE-06?MCK?)
18,500
[5.4]
13,400
[3.9]
5,100
[1.5]
12.50 15.00 76
575
[271]
17,700
[5.2]
3.68
10,800
[3.2]
2.38 8.20
RCFL-H*2417 (RGFE-07?MCK?)
18,400
[5.4]
13,300
[3.9]
5,100
[1.5]
12.50 15.00 76
600
[283]
17,700
[5.2]
3.68
10,800
[3.2]
2.38 8.20
RCFL-H*2417 (RGGD-06?MCK?)
18,500
[5.4]
13,400
[3.9]
5,100
[1.5]
12.50 15.00 76
600
[283]
17,700
[5.2]
3.68
10,800
[3.2]
2.38 8.20
RCFL-H*2417 (RGGD-07?MCK?)
18,400
[5.4]
13,300
[3.9]
5,100
[1.5]
12.50 15.00 76
625
[295]
17,700
[5.2]
3.66
10,800
[3.2]
2.36 8.20
RCFL-H*2417 (RGGE-06?MCK?)
18,400
[5.4]
13,300
[3.9]
5,100
[1.5]
12.50 15.00 76
600
[283]
17,700
[5.2]
3.66
10,800
[3.2]
2.38 8.20
RCFL-H*2417 (RGGE-07?MCK?)
18,500
[5.4]
13,400
[3.9]
5,100
[1.5]
12.50 15.00 76
575
[271]
17,700
[5.2]
3.68
10,800
[3.2]
2.38 8.20
RCFL-H*2417 (RGJD-06?MCK?)
18,500
[5.4]
13,400
[3.9]
5,100
[1.5]
12.50 15.00 76
600
[283]
17,700
[5.2]
3.68
10,800
[3.2]
2.38 8.20
RCFL-H*2417 (RGJD-07?MCK?)
18,400
[5.4]
13,300
[3.9]
5,100
[1.5]
12.50 15.00 76
625
[295]
17,700
[5.2]
3.66
10,800
[3.2]
2.36 8.20
RCFL-H*2417 (RGJF-06?MCK?)
18,500
[5.4]
13,400
[3.9]
5,100
[1.5]
12.50 15.00 76
625
[295]
17,700
[5.2]
3.68
10,800
[3.2]
2.38 8.20
RCFL-H*2417 (RGJF-07?MCK?)
18,500
[5.4]
13,400
[3.9]
5,100
[1.5]
12.50 15.00 76
575
[271]
17,700
[5.2]
3.68
10,800
[3.2]
2.38 8.20
RCFL-H*2417 (RGLE-07?AMK?)
18,500
[5.4]
13,400
[3.9]
5,100
[1.5]
12.50 15.00 76
600
[283]
17,700
[5.2]
3.70
10,800
[3.2]
2.38 8.20
RCFL-H*2417 (RGLR-07?AMK?)
18,500
[5.4]
13,400
[3.9]
5,100
[1.5]
12.50 15.00 76
600
[283]
17,700
[5.2]
3.68
10,800
[3.2]
2.38 8.20
RCFL-H*2417 (RGLT-07?AME?)
18,900
[5.5]
13,950
[4.1]
4,950
[1.5]
12.50 15.00 76
675
[319]
17,700
[5.2]
3.66
10,800
[3.2]
2.36 8.20
Rev.
7/1/10
2 Rheem Heating, Cooling and Water Heating
Model Identification Number
15 P J 18
NOMINAL COOLING CAPACITY
18 = 18,000 BTU/HR [5.28 kW] 24 = 24,000 BTU/HR [7.03 kW] 30 = 30,000 BTU/HR [8.79 kW] 36 = 36,000 BTU/HR [10.55 kW] 42 = 42,000 BTU/HR [12.31 kW] 48 = 48,000 BTU/HR [14.07 kW] 60 = 60,000 BTU/HR [17.58 kW]
L A 01
15 SEER P = HEAT PUMP VOLTAGE
J = 208-230 SINGLE PHASE
L = 1ST DESIGN
(R-410A)
CABINET
A = FULL METAL JACKET
RHEEM
VALUE SERIES
Performance Data AHRI Standard Conditions
Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Page 3
Model Numbers
AHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)
80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Outdoor Air
47°F [8.5°C] DB/
43°F [6°C] WB
DOE High Temp.
Outdoor Air
17°F [–8.5°C] DB/
15°F [–9.5°C] WB
DOE Low Temp.
DOE
Region
IV
HSPF
Outdoor
Unit
15PJL
Indoor Coil and/or Air Handler
Tot al
Capacity
BTU/H
[kW]
Net
Sens.
BTU/H
[kW]
Net Latent BTU/H
[kW]
EER SEER
Snd. Rate
dB
Indoor
CFM [L/s]
BTU/H
[kW]
COP
BTU/H
[kW]
COP
18
RCFL-H*2417 (RGPE-05?BMK?)
18,500
[5.4]
13,400
[3.9]
5,100
[1.5]
12.50 15.00 76
575
[271]
17,700
[5.2]
3.68
10,800
[3.2]
2.38 8.20
RCFL-H*2417 (RGPE-07?AMK?)
18,500
[5.4]
13,400
[3.9]
5,100
[1.5]
12.50 15.00 76
625
[295]
17,700
[5.2]
3.68
10,800
[3.2]
2.38 8.20
RCFL-H*2417 (RGPL-05?BMK?)
18,400
[5.4]
13,350
[3.9]
5,050
[1.5]
12.50 15.00 76
600
[283]
17,800
[5.2]
3.64
10,900
[3.2]
2.36 8.20
RCFL-H*2417 (RGPR-05?BMK?)
18,400
[5.4]
13,350
[3.9]
5,050
[1.5]
12.50 15.00 76
600
[283]
17,800
[5.2]
3.64
10,900
[3.2]
2.36 8.20
RCFL-H*2417 (RGPR-07?AMK?)
18,500
[5.4]
13,400
[3.9]
5,100
[1.5]
12.50 15.00 76
600
[283]
17,700
[5.2]
3.68
10,800
[3.2]
2.38 8.20
RCFL-H*2417 (RGPT-05?BMK?)
18,700
[5.5]
13,700
[4.0]
5,000
[1.5]
12.50 15.00 76
650
[307]
17,800
[5.2]
3.64
10,900
[3.2]
2.36 8.20
RCFL-H*2417 (RGPT-07?AME?)
18,400
[5.4]
13,300
[3.9]
5,100
[1.5]
12.50 15.00 76
625
[295]
17,700
[5.2]
3.66
10,800
[3.2]
2.36 8.20
RCFL-H*2417 (RGRM-04?MAE?)
18,400
[5.4]
13,350
[3.9]
5,050
[1.5]
12.50 15.00 76
575
[271]
17,800
[5.2]
3.66
10,900
[3.2]
2.36 8.20
RCFL-H*2417 (RGRM-06?MAE?)
18,400
[5.4]
13,300
[3.9]
5,100
[1.5]
12.50 15.00 76
600
[283]
17,700
[5.2]
3.66
10,800
[3.2]
2.36 8.20
RCFL-H*2417 (RGRM-07?MAE?)
18,300
[5.4]
13,250
[3.9]
5,050
[1.5]
12.50 15.00 76
625
[295]
17,800
[5.2]
3.62
10,900
[3.2]
2.34 8.20
RCFL-H*2417 (RGTM-06?MAE?)
18,500
[5.4]
13,400
[3.9]
5,100
[1.5]
12.50 15.00 76
575
[271]
17,700
[5.2]
3.70
10,800
[3.2]
2.38 8.20
ROCA-070E03 (RCFL-H*2417)
18,500
[5.4]
13,400
[3.9]
5,100
[1.5]
12.50 15.00 76
600
[283]
17,700
[5.2]
3.68
10,800
[3.2]
2.38 8.20
ROLA-070E03 (RCFL-H*2417)
18,400
[5.4]
13,350
[3.9]
5,050
[1.5]
12.50 15.00 76
600
[283]
17,800
[5.2]
3.66
10,900
[3.2]
2.36 8.20
RHKL-HM2417 (RCSL-H*2417)
18,700
[5.5]
13,700
[4.0]
5,000
[1.5]
12.50 15.00 76
650
[307]
17,700
[5.2]
3.66
10,800
[3.2]
2.36 8.20
RHSL-HM1817 (RCSL-H*2417)
18,100
[5.3]
13,100
[3.8]
5,000
[1.5]
11.50 14.00 76
600
[283]
18,100
[5.3]
3.48
11,200
[3.3]
2.26 8.00
24
RHLL-HM2417 (RCSL-H*2417)
23,600
[6.9]
16,800
[4.9]
6,800
[2.0]
12.50 15.00 74
775
[366]
21,600
[6.3]
3.58
12,400
[3.6]
2.22 8.50
RHBL-FR24T
25,000
[7.3]
19,350
[5.7]
5,650
[1.7]
12.50 15.00 74
850
[401]
21,400
[6.3]
3.56
12,300
[3.6]
2.14 8.20
RCFL-A*2414
23,200
[6.8]
16,400
[4.8]
6,800
[2.0]
11.00 13.50 74
775
[366]
22,200
[6.5]
3.34
13,000
[3.8]
2.06 7.70
RCFL-H*2417
23,200
[6.8]
16,400
[4.8]
6,800
[2.0]
11.00 13.50 74
775
[366]
22,200
[6.5]
3.34
13,000
[3.8]
2.06 7.70
RCFL-H*2417 (RGFD-06?MCK?)
23,200
[6.8]
16,500
[4.8]
6,700
[2.0]
11.50 14.00 74
800
[378]
21,800
[6.4]
3.46
12,600
[3.7]
2.12 8.20
RCFL-H*2417 (RGFD-07?MCK?)
23,200
[6.8]
16,500
[4.8]
6,700
[2.0]
11.50 14.00 74
800
[378]
21,800
[6.4]
3.48
12,600
[3.7]
2.12 8.20
RCFL-H*2417 (RGFE-06?MCK?)
23,400
[6.9]
16,650
[4.9]
6,750
[2.0]
12.00 14.50 74
800
[378]
21,800
[6.4]
3.50
12,500
[3.7]
2.14 8.20
RCFL-H*2417 (RGFE-07?MCK?)
23,600
[6.9]
17,000
[5.0]
6,600
[1.9]
12.00 14.50 74
825
[389]
21,800
[6.4]
3.50
12,500
[3.7]
2.14 8.20
RCFL-H*2417 (RGGD-06?MCK?)
23,400
[6.9]
16,650
[4.9]
6,750
[2.0]
12.00 14.50 74
800
[378]
21,800
[6.4]
3.52
12,500
[3.7]
2.14 8.20
RCFL-H*2417 (RGGE-06?MCK?)
23,600
[6.9]
16,950
[5.0]
6,650
[1.9]
12.50 15.00 74
825
[389]
21,600
[6.3]
3.54
12,400
[3.6]
2.16 8.20
Rev.
7/1/10
Rheem Heating, Cooling and Water Heating 3
Performance Data AHRI Standard Conditions (cont.)
Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Page 4
Model Numbers
AHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)
80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Outdoor Air
47°F [8.5°C] DB/
43°F [6°C] WB
DOE High Temp.
Outdoor Air 17°F [–8.5°C] DB/ 15°F [–9.5°C] WB
DOE Low Temp.
DOE
Region
IV
HSPF
Outdoor
Unit
15PJL
Indoor Coil and/or Air Handler
Tot al
Capacity
BTU/H
[kW]
Net
Sens.
BTU/H
[kW]
Net Latent BTU/H
[kW]
EER SEER
Snd. Rate
dB
Indoor
CFM [L/s]
BTU/H
[kW]
COP
BTU/H
[kW]
COP
24
RCFL-H*2417 (RGGE-07?MCK?)
23,400
[6.9]
16,650
[4.9]
6,750
[2.0]
12.50 15.00 74
750
[354]
21,600
[6.3]
3.54
12,400
[3.6]
2.16 8.20
RCFL-H*2417 (RGJD-06?MCK?)
23,400
[6.9]
16,650
[4.9]
6,750
[2.0]
12.00 14.50 74
800
[378]
21,800
[6.4]
3.52
12,500
[3.7]
2.14 8.20
RCFL-H*2417 (RGJD-07?MCK?)
23,400
[6.9]
16,700
[4.9]
6,700
[2.0]
12.00 14.50 74
800
[378]
21,800
[6.4]
3.50
12,600
[3.7]
2.14 8.20
RCFL-H*2417 (RGJF-06?MCK?)
23,600
[6.9]
16,950
[5.0]
6,650
[1.9]
12.50 15.00 74
825
[389]
21,600
[6.3]
3.54
12,400
[3.6]
2.16 8.20
RCFL-H*2417 (RGJF-07?MCK?)
23,400
[6.9]
16,650
[4.9]
6,750
[2.0]
12.50 15.00 74
750
[354]
21,600
[6.3]
3.54
12,400
[3.6]
2.16 8.20
RCFL-H*2417 (RGLE-07?AMK?)
23,600
[6.9]
16,850
[4.9]
6,750
[2.0]
12.50 15.00 74
750
[354]
21,600
[6.3]
3.56
12,400
[3.6]
2.16 8.50
RCFL-H*2417 (RGLR-07?AMK?)
23,400
[6.9]
16,650
[4.9]
6,750
[2.0]
12.00 14.50 74
800
[378]
21,600
[6.3]
3.54
12,400
[3.6]
2.16 8.20
RCFL-H*2417 (RGLT-07?AME?)
23,800
[7.0]
17,250
[5.1]
6,550
[1.9]
12.00 14.50 74
850
[401]
21,800
[6.4]
3.50
12,500
[3.7]
2.14 8.20
RCFL-H*2417 (RGPE-05?BMK?)
23,400
[6.9]
16,650
[4.9]
6,750
[2.0]
12.50 15.00 74
750
[354]
21,600
[6.3]
3.54
12,400
[3.6]
2.16 8.20
RCFL-H*2417 (RGPE-07?AMK?)
23,600
[6.9]
17,000
[5.0]
6,600
[1.9]
12.50 15.00 74
825
[389]
21,600
[6.3]
3.54
12,500
[3.7]
2.16 8.20
RCFL-H*2417 (RGPR-05?BMK?)
23,200
[6.8]
16,500
[4.8]
6,700
[2.0]
12.00 14.50 74
775
[366]
21,800
[6.4]
3.48
12,600
[3.7]
2.12 8.20
RCFL-H*2417 (RGPR-07?AMK?)
23,400
[6.9]
16,650
[4.9]
6,750
[2.0]
12.50 15.00 74
750
[354]
21,600
[6.3]
3.56
12,400
[3.6]
2.16 8.20
RCFL-H*2417 (RGPT-05?BMK?)
23,800
[7.0]
17,250
[5.1]
6,550
[1.9]
12.00 14.50 74
850
[401]
21,800
[6.4]
3.48
12,600
[3.7]
2.12 8.20
RCFL-H*2417 (RGPT-07?AME?)
23,800
[7.0]
17,250
[5.1]
6,550
[1.9]
12.00 14.50 74
850
[401]
21,800
[6.4]
3.50
12,600
[3.7]
2.14 8.20
RCFL-H*2417 (RGRM-04?MAE?)
23,400
[6.9]
16,650
[4.9]
6,750
[2.0]
12.00 14.50 74
750
[354]
21,600
[6.3]
3.52
12,500
[3.7]
2.14 8.20
RCFL-H*2417 (RGRM-06?MAE?)
23,400
[6.9]
16,650
[4.9]
6,750
[2.0]
12.00 14.50 74
775
[366]
21,600
[6.3]
3.52
12,500
[3.7]
2.14 8.20
RCFL-H*2417 (RGRM-07?MAE?)
23,200
[6.8]
16,500
[4.8]
6,700
[2.0]
11.50 14.00 74
800
[378]
21,800
[6.4]
3.46
12,600
[3.7]
2.12 8.20
RCFL-H*2417 (RGTM-06?MAE?)
23,400
[6.9]
16,650
[4.9]
6,750
[2.0]
12.50 15.00 74
750
[354]
21,600
[6.3]
3.56
12,400
[3.6]
2.16 8.50
ROCA-070E03 (RCFL-H*2417)
23,400
[6.9]
16,650
[4.9]
6,750
[2.0]
12.00 14.50 74
800
[378]
21,600
[6.3]
3.54
12,400
[3.6]
2.16 8.20
ROCA-070E04 (RCFL-H*2417)
23,400
[6.9]
16,650
[4.9]
6,750
[2.0]
12.00 14.50 74
800
[378]
21,600
[6.3]
3.54
12,400
[3.6]
2.16 8.20
ROLA-070E03 (RCFL-H*2417)
23,400
[6.9]
16,650
[4.9]
6,750
[2.0]
12.00 14.50 74
800
[378]
21,600
[6.3]
3.54
12,500
[3.7]
2.16 8.20
ROLA-070E04 (RCFL-H*2417)
23,400
[6.9]
16,650
[4.9]
6,750
[2.0]
12.00 14.50 74
800
[378]
21,600
[6.3]
3.54
12,500
[3.7]
2.16 8.20
RHKL-HM2417 (RCSL-H*2417)
23,200
[6.8]
17,200
[5.0]
6,000
[1.8]
12.50 15.00 74
825
[389]
21,800
[6.4]
3.52
12,500
[3.7]
2.14 8.50
RHSL-HM2417 (RCSL-H*2417)
23,000
[6.7]
16,350
[4.8]
6,650
[1.9]
11.00 13.50 74
800
[378]
22,000
[6.4]
3.36
12,900
[3.8]
2.08 7.70
Rev.
7/1/10
4 Rheem Heating, Cooling and Water Heating
Performance Data AHRI Standard Conditions (cont.)
Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Page 5
Model Numbers
AHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)
80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Outdoor Air
47°F [8.5°C] DB/
43°F [6°C] WB
DOE High Temp.
Outdoor Air
17°F [–8.5°C] DB/
15°F [–9.5°C] WB
DOE Low Temp.
DOE
Region
IV
HSPF
Outdoor
Unit
15PJL
Indoor Coil and/or Air Handler
Tot al
Capacity
BTU/H
[kW]
Net
Sens.
BTU/H
[kW]
Net Latent BTU/H
[kW]
EER SEER
Snd. Rate
dB
Indoor
CFM [L/s]
BTU/H
[kW]
COP
BTU/H
[kW]
COP
30
RHLL-HM3617 (RCSL-H*3617)
28,800
[8.4]
21,250
[6.2]
7,550
[2.2]
12.50 15.00 73
950
[448]
27,200
[8.0]
3.62
16,300
[4.8]
2.30 8.50
RHBL-FR36T
29,000
[8.5]
22,300
[6.5]
6,700
[2.0]
12.50 15.00 73
975
[460]
28,000
[8.2]
3.74
16,700
[4.9]
2.42 8.50
RCFL-H*3617
28,600
[8.4]
21,050
[6.2]
7,550
[2.2]
11.50 13.50 73
950
[448]
27,800
[8.1]
3.42
16,900
[5.0]
2.20 7.70
RCFL-H*3617 (RGFD-06?MCK?)
28,600
[8.4]
21,300
[6.2]
7,300
[2.1]
11.50 13.50 73
1,000 [472]
27,600
[8.1]
3.46
16,800
[4.9]
2.22 7.70
RCFL-H*3617 (RGFD-07?MCK?)
28,800
[8.4]
21,500
[6.3]
7,300
[2.1]
11.50 14.00 73
1,000 [472]
27,600
[8.1]
3.50
16,600
[4.9]
2.24 8.20
RCFL-H*3617 (RGFE-06?MCK?)
28,800
[8.4]
21,500
[6.3]
7,300
[2.1]
11.50 14.00 73
1,000 [472]
27,600
[8.1]
3.50
16,600
[4.9]
2.24 8.20
RCFL-H*3617 (RGFE-07?MCK?)
28,800
[8.4]
21,600
[6.3]
7,200
[2.1]
11.50 14.00 73
1,025 [484]
27,600
[8.1]
3.48
16,700
[4.9]
2.24 8.20
RCFL-H*3617 (RGGD-07?MCK?)
29,000
[8.5]
21,800
[6.4]
7,200
[2.1]
11.50 14.00 73
1,025 [484]
27,600
[8.1]
3.50
16,600
[4.9]
2.24 8.20
RCFL-H*3617 (RGGE-06?MCK?)
28,800
[8.4]
21,500
[6.3]
7,300
[2.1]
11.50 14.00 73
1,000 [472]
27,400
[8.0]
3.52
16,600
[4.9]
2.26 8.20
RCFL-H*3617 (RGGE-07?MCK?)
29,000
[8.5]
21,750
[6.4]
7,250
[2.1]
11.50 14.00 73
1,025 [484]
27,400
[8.0]
3.52
16,600
[4.9]
2.26 8.20
RCFL-H*3617 (RGJF-06?MCK?)
28,800
[8.4]
21,500
[6.3]
7,300
[2.1]
11.50 14.00 73
1,000 [472]
27,400
[8.0]
3.52
16,600
[4.9]
2.26 8.20
RCFL-H*3617 (RGJF-07?MCK?)
29,000
[8.5]
21,750
[6.4]
7,250
[2.1]
11.50 14.00 73
1,025 [484]
27,400
[8.0]
3.52
16,600
[4.9]
2.26 8.20
RCFL-H*3617 (RGLE-07?AMK?)
29,200
[8.6]
21,950
[6.4]
7,250
[2.1]
12.00 14.50 73
1,025 [484]
27,400
[8.0]
3.56
16,400
[4.8]
2.28 8.20
RCFL-H*3617 (RGLR-07?AMK?)
29,000
[8.5]
21,750
[6.4]
7,250
[2.1]
12.00 14.50 73
1,025 [484]
27,400
[8.0]
3.54
16,500
[4.8]
2.28 8.20
RCFL-H*3617 (RGLT-07?AME?)
29,200
[8.6]
22,050
[6.5]
7,150
[2.1]
12.00 14.50 73
1,050 [495]
27,400
[8.0]
3.52
16,500
[4.8]
2.26 8.20
RCFL-H*3617 (RGPE-05?BMK?)
28,600
[8.4]
21,100
[6.2]
7,500
[2.2]
11.50 14.00 73
975
[460]
27,400
[8.0]
3.54
16,500
[4.8]
2.26 8.20
RCFL-H*3617 (RGPE-07?AMK?)
29,000
[8.5]
21,650
[6.3]
7,350
[2.2]
12.00 14.50 73
1,000 [472]
27,400
[8.0]
3.54
16,500
[4.8]
2.28 8.20
RCFL-H*3617 (RGPR-05?BMK?)
28,800
[8.4]
21,500
[6.3]
7,300
[2.1]
11.50 14.00 73
1,000 [472]
27,600
[8.1]
3.48
16,700
[4.9]
2.24 8.20
RCFL-H*3617 (RGPR-07?AMK?)
29,000
[8.5]
21,650
[6.3]
7,350
[2.2]
12.00 14.50 73
1,000 [472]
27,400
[8.0]
3.54
16,500
[4.8]
2.26 8.20
RCFL-H*3617 (RGPT-05?BMK?)
29,000
[8.5]
21,850
[6.4]
7,150
[2.1]
11.50 14.00 73
1,050 [495]
27,600
[8.1]
3.48
16,700
[4.9]
2.24 8.20
RCFL-H*3617 (RGPT-07?AME?)
29,200
[8.6]
22,050
[6.5]
7,150
[2.1]
11.50 14.00 73
1,050 [495]
27,600
[8.1]
3.50
16,600
[4.9]
2.24 8.20
RCFL-H*3617 (RGRM-04?MAE?)
28,800
[8.4]
21,600
[6.3]
7,200
[2.1]
11.50 13.50 73
1,025 [484]
27,600
[8.1]
3.46
16,800
[4.9]
2.22 7.70
RCFL-H*3617 (RGRM-06?MAE?)
28,800
[8.4]
21,500
[6.3]
7,300
[2.1]
11.50 14.00 73
1,000 [472]
27,600
[8.1]
3.48
16,700
[4.9]
2.24 8.20
RCFL-H*3617 (RGRM-07?MAE?)
28,400
[8.3]
20,950
[6.1]
7,450
[2.2]
11.50 13.50 73
950
[448]
27,600
[8.1]
3.48
16,700
[4.9]
2.24 7.70
RCFL-H*3617 (RGTM-06?MAE?)
28,600
[8.4]
20,850
[6.1]
7,750
[2.3]
12.00 14.50 73
900
[425]
27,200
[8.0]
3.60
16,300
[4.8]
2.30 8.20
Rev.
7/1/10
Rheem Heating, Cooling and Water Heating 5
Performance Data AHRI Standard Conditions (cont.)
Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Page 6
Model Numbers
AHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)
80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Outdoor Air
47°F [8.5°C] DB/
43°F [6°C] WB
DOE High Temp.
Outdoor Air
17°F [–8.5°C] DB/
15°F [–9.5°C] WB
DOE Low Temp.
DOE
Region
IV
HSPF
Outdoor
Unit
15PJL
Indoor Coil and/or Air Handler
Tot al
Capacity
BTU/H
[kW]
Net
Sens.
BTU/H
[kW]
Net Latent BTU/H
[kW]
EER SEER
Snd. Rate
dB
Indoor
CFM [L/s]
BTU/H
[kW]
COP
BTU/H
[kW]
COP
30
ROCA-070E03 (RCFL-H*3617)
29,000
[8.5]
21,650
[6.3]
7,350
[2.2]
12.00 14.50 73
1,000 [472]
27,400
[8.0]
3.56
16,400
[4.8]
2.28 8.20
ROCA-070E04 (RCFL-H*3617)
29,000
[8.5]
21,650
[6.3]
7,350
[2.2]
12.00 14.50 73
1,000 [472]
27,400
[8.0]
3.56
16,400
[4.8]
2.28 8.20
ROLA-070E03 (RCFL-H*3617)
28,800
[8.4]
21,250
[6.2]
7,550
[2.2]
12.00 14.50 73
975
[460]
27,200
[8.0]
3.58
16,400
[4.8]
2.30 8.20
ROLA-070E04 (RCFL-H*3617)
28,800
[8.4]
21,250
[6.2]
7,550
[2.2]
12.00 14.50 73
975
[460]
27,200
[8.0]
3.58
16,400
[4.8]
2.30 8.20
RCFL-H*3621
28,600
[8.4]
21,050
[6.2]
7,550
[2.2]
11.50 13.50 73
950
[448]
27,800
[8.1]
3.42
16,900
[5.0]
2.20 7.70
RCFL-H*3621 (RGFD-06?MCK?)
28,600
[8.4]
21,300
[6.2]
7,300
[2.1]
11.50 13.50 73
1,000 [472]
27,600
[8.1]
3.46
16,700
[4.9]
2.22 7.70
RCFL-H*3621 (RGFD-07?MCK?)
28,800
[8.4]
21,500
[6.3]
7,300
[2.1]
11.50 14.00 73
1,000 [472]
27,600
[8.1]
3.50
16,600
[4.9]
2.24 8.20
RCFL-H*3621 (RGFE-06?MCK?)
28,800
[8.4]
21,500
[6.3]
7,300
[2.1]
11.50 14.00 73
1,000 [472]
27,400
[8.0]
3.52
16,600
[4.9]
2.26 8.20
RCFL-H*3621 (RGFE-07?MCK?)
29,000
[8.5]
21,800
[6.4]
7,200
[2.1]
11.50 14.00 73
1,025 [484]
27,600
[8.1]
3.50
16,600
[4.9]
2.24 8.20
RCFL-H*3621 (RGFE-09?ZCM?)
28,800
[8.4]
21,250
[6.2]
7,550
[2.2]
12.00 14.50 73
975
[460]
27,200
[8.0]
3.58
16,400
[4.8]
2.30 8.20
RCFL-H*3621 (RGFE-10?ZCM?)
29,000
[8.5]
21,750
[6.4]
7,250
[2.1]
12.00 14.50 73
1,025 [484]
27,400
[8.0]
3.54
16,500
[4.8]
2.28 8.20
RCFL-H*3621 (RGGD-07?MCK?)
29,000
[8.5]
21,800
[6.4]
7,200
[2.1]
11.50 14.00 73
1,025 [484]
27,600
[8.1]
3.50
16,600
[4.9]
2.24 8.50
RCFL-H*3621 (RGGE-06?MCK?)
28,800
[8.4]
21,450
[6.3]
7,350
[2.2]
11.50 14.00 73
1,000 [472]
27,400
[8.0]
3.52
16,500
[4.8]
2.26 8.50
RCFL-H*3621 (RGGE-07?MCK?)
29,000
[8.5]
21,750
[6.4]
7,250
[2.1]
11.50 14.00 73
1,025 [484]
27,400
[8.0]
3.52
16,600
[4.9]
2.26 8.20
RCFL-H*3621 (RGGE-09?ZCM?)
29,200
[8.6]
21,950
[6.4]
7,250
[2.1]
12.00 14.50 73
1,025 [484]
27,400
[8.0]
3.56
16,400
[4.8]
2.28 8.20
RCFL-H*3621 (RGGE-10?ZCM?)
29,000
[8.5]
21,650
[6.3]
7,350
[2.2]
12.00 14.50 73
1,000 [472]
27,200
[8.0]
3.58
16,400
[4.8]
2.28 8.20
RCFL-H*3621 (RGJF-06?MCK?)
28,800
[8.4]
21,450
[6.3]
7,350
[2.2]
11.50 14.00 73
1,000 [472]
27,400
[8.0]
3.52
16,500
[4.8]
2.26 8.50
RCFL-H*3621 (RGJF-07?MCK?)
29,000
[8.5]
21,750
[6.4]
7,250
[2.1]
11.50 14.00 73
1,025 [484]
27,400
[8.0]
3.52
16,600
[4.9]
2.26 8.50
RCFL-H*3621 (RGJF-09?ZCM?)
29,200
[8.6]
21,950
[6.4]
7,250
[2.1]
12.00 14.50 73
1,025 [484]
27,400
[8.0]
3.56
16,400
[4.8]
2.28 8.50
RCFL-H*3621 (RGJF-10?ZCM?)
29,000
[8.5]
21,650
[6.3]
7,350
[2.2]
12.00 14.50 73
1,000 [472]
27,200
[8.0]
3.58
16,400
[4.8]
2.28 8.50
RCFL-H*3621 (RGLE-07?AMK?)
29,200
[8.6]
21,900
[6.4]
7,300
[2.1]
12.00 14.50 73
1,025 [484]
27,400
[8.0]
3.56
16,400
[4.8]
2.28 8.20
RCFL-H*3621 (RGLE-07?BRQ?)
29,200
[8.6]
21,900
[6.4]
7,300
[2.1]
12.50 15.00 73
1,025 [484]
27,200
[8.0]
3.60
16,300
[4.8]
2.30 8.50
RCFL-H*3621 (RGLE-10?BRM?)
29,400
[8.6]
22,200
[6.5]
7,200
[2.1]
12.50 15.00 73
1,050 [495]
27,200
[8.0]
3.62
16,300
[4.8]
2.30 8.50
RCFL-H*3621 (RGLR-07?AMK?)
29,200
[8.6]
21,950
[6.4]
7,250
[2.1]
12.00 14.50 73
1,025 [484]
27,400
[8.0]
3.56
16,400
[4.8]
2.28 8.50
RCFL-H*3621 (RGLR-07?BRQ?)
29,200
[8.6]
21,800
[6.4]
7,400
[2.2]
12.50 15.00 73
1,000 [472]
27,200
[8.0]
3.62
16,300
[4.8]
2.30 8.50
Rev.
7/1/10
6 Rheem Heating, Cooling and Water Heating
Performance Data AHRI Standard Conditions (cont.)
Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Page 7
Model Numbers
AHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)
80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Outdoor Air
47°F [8.5°C] DB/
43°F [6°C] WB
DOE High Temp.
Outdoor Air
17°F [–8.5°C] DB/
15°F [–9.5°C] WB
DOE Low Temp.
DOE
Region
IV
HSPF
Outdoor
Unit
15PJL
Indoor Coil and/or Air Handler
Tot al
Capacity
BTU/H
[kW]
Net
Sens.
BTU/H
[kW]
Net Latent BTU/H
[kW]
EER SEER
Snd. Rate
dB
Indoor
CFM [L/s]
BTU/H
[kW]
COP
BTU/H
[kW]
COP
30
RCFL-H*3621 (RGLR-10?BRM?)
29,400
[8.6]
22,200
[6.5]
7,200
[2.1]
12.50 15.00 73
1,050 [495]
27,200
[8.0]
3.60
16,300
[4.8]
2.30 8.50
RCFL-H*3621 (RGLT-07?AME?)
29,400
[8.6]
22,300
[6.5]
7,100
[2.1]
12.00 14.50 73
1,075 [507]
27,400
[8.0]
3.54
16,500
[4.8]
2.26 8.20
RCFL-H*3621 (RGLT-07?BRQ?)
29,000
[8.5]
21,400
[6.3]
7,600
[2.2]
12.50 15.00 73
975
[460]
27,200
[8.0]
3.62
16,300
[4.8]
2.30 8.50
RCFL-H*3621 (RGLT-10?BRM?)
29,000
[8.5]
21,400
[6.3]
7,600
[2.2]
12.50 15.00 73
975
[460]
27,200
[8.0]
3.62
16,200
[4.7]
2.32 8.50
RCFL-H*3621 (RGPE-05?BMK?)
28,600
[8.4]
21,100
[6.2]
7,500
[2.2]
11.50 14.00 73
975
[460]
27,400
[8.0]
3.54
16,500
[4.8]
2.28 8.20
RCFL-H*3621 (RGPE-07?AMK?)
29,000
[8.5]
21,650
[6.3]
7,350
[2.2]
12.00 14.50 73
1,000 [472]
27,400
[8.0]
3.56
16,400
[4.8]
2.28 8.20
RCFL-H*3621 (RGPE-07?BRQ?)
29,200
[8.6]
21,900
[6.4]
7,300
[2.1]
12.50 15.00 73
1,025 [484]
27,200
[8.0]
3.62
16,300
[4.8]
2.30 8.50
RCFL-H*3621 (RGPE-10?BRM?)
28,800
[8.4]
21,050
[6.2]
7,750
[2.3]
12.50 15.00 73
900
[425]
27,000
[7.9]
3.66
16,100
[4.7]
2.34 8.50
RCFL-H*3621 (RGPR-05?BMK?)
28,800
[8.4]
21,500
[6.3]
7,300
[2.1]
11.50 14.00 73
1,000 [472]
27,600
[8.1]
3.50
16,600
[4.9]
2.24 8.20
RCFL-H*3621 (RGPR-07?AMK?)
29,000
[8.5]
21,650
[6.3]
7,350
[2.2]
12.00 14.50 73
1,000 [472]
27,400
[8.0]
3.54
16,500
[4.8]
2.28 8.20
RCFL-H*3621 (RGPR-07?BRQ?)
29,200
[8.6]
21,800
[6.4]
7,400
[2.2]
12.50 15.00 73
1,000 [472]
27,200
[8.0]
3.62
16,300
[4.8]
2.30 8.50
RCFL-H*3621 (RGPR-10?BRM?)
29,000
[8.5]
21,400
[6.3]
7,600
[2.2]
12.50 15.00 73
925
[437]
27,200
[8.0]
3.64
16,200
[4.7]
2.32 8.50
RCFL-H*3621 (RGPT-05?BMK?)
29,200
[8.6]
22,150
[6.5]
7,050
[2.1]
11.50 14.00 73
1,075 [507]
27,600
[8.1]
3.48
16,700
[4.9]
2.24 8.20
RCFL-H*3621 (RGPT-07?AME?)
29,200
[8.6]
22,050
[6.5]
7,150
[2.1]
11.50 14.00 73
1,050 [495]
27,600
[8.1]
3.50
16,600
[4.9]
2.24 8.20
RCFL-H*3621 (RGPT-07?BRQ?)
29,400
[8.6]
22,150
[6.5]
7,250
[2.1]
12.50 15.00 73
1,050 [495]
27,200
[8.0]
3.62
16,200
[4.7]
2.32 8.50
RCFL-H*3621 (RGPT-10?BRM?)
29,000
[8.5]
21,400
[6.3]
7,600
[2.2]
12.50 15.00 73
975
[460]
27,200
[8.0]
3.62
16,200
[4.7]
2.32 8.50
RCFL-H*3621 (RGRM-04?MAE?)
28,800
[8.4]
21,600
[6.3]
7,200
[2.1]
11.50 13.50 73
1,025 [484]
27,600
[8.1]
3.46
16,700
[4.9]
2.22 8.20
RCFL-H*3621 (RGRM-06?MAE?)
28,800
[8.4]
21,500
[6.3]
7,300
[2.1]
11.50 14.00 73
1,000 [472]
27,600
[8.1]
3.50
16,600
[4.9]
2.24 8.20
RCFL-H*3621 (RGRM-07?MAE?)
28,400
[8.3]
20,950
[6.1]
7,450
[2.2]
11.50 14.00 73
950
[448]
27,600
[8.1]
3.48
16,700
[4.9]
2.24 8.20
RCFL-H*3621 (RGRM-07?YBG?)
28,400
[8.3]
20,950
[6.1]
7,450
[2.2]
11.50 13.50 73
975
[460]
27,600
[8.1]
3.48
16,700
[4.9]
2.24 7.70
RCFL-H*3621 (RGRM-09?ZAJ?)
28,800
[8.4]
21,250
[6.2]
7,550
[2.2]
12.00 14.50 73
950
[448]
27,200
[8.0]
3.58
16,400
[4.8]
2.28 8.20
RCFL-H*3621 (RGRM-10?ZAJ?)
29,000
[8.5]
21,750
[6.4]
7,250
[2.1]
11.50 14.00 73
1,025 [484]
27,400
[8.0]
3.54
16,500
[4.8]
2.26 8.20
RCFL-H*3621 (RGTM-06?MAE?)
28,600
[8.4]
20,850
[6.1]
7,750
[2.3]
12.00 14.50 73
900
[425]
27,200
[8.0]
3.62
16,300
[4.8]
2.30 8.20
RCFL-H*3621 (RGTM-07?RBG?)
28,800
[8.4]
21,250
[6.2]
7,550
[2.2]
12.50 15.00 73
950
[448]
27,200
[8.0]
3.62
16,300
[4.8]
2.30 8.50
RCFL-H*3621 (RGTM-09?ZAJ?)
28,800
[8.4]
21,250
[6.2]
7,550
[2.2]
12.00 14.50 73
975
[460]
27,200
[8.0]
3.62
16,300
[4.8]
2.30 8.20
Rev.
7/1/10
Rheem Heating, Cooling and Water Heating 7
Performance Data AHRI Standard Conditions (cont.)
Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Page 8
Model Numbers
AHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)
80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Outdoor Air
47°F [8.5°C] DB/
43°F [6°C] WB
DOE High Temp.
Outdoor Air 17°F [–8.5°C] DB/ 15°F [–9.5°C] WB
DOE Low Temp.
DOE
Region
IV
HSPF
Outdoor
Unit
15PJL
Indoor
Coil and/or
Air Handler
Tot al
Capacity
BTU/H
[kW]
Net
Sens.
BTU/H
[kW]
Net Latent BTU/H
[kW]
EER SEER
Snd. Rate
dB
Indoor
CFM
[L/s]
BTU/H
[kW]
COP
BTU/H
[kW]
COP
30
ROCA-070E03 (RCFL-H*3621)
29,000
[8.5]
21,650
[6.3]
7,350
[2.2]
12.00 14.50 73
1,000 [472]
27,400
[8.0]
3.58
16,400
[4.8]
2.28 8.20
ROCA-070E04 (RCFL-H*3621)
29,000
[8.5]
21,650
[6.3]
7,350
[2.2]
12.00 14.50 73
1,000 [472]
27,400
[8.0]
3.58
16,400
[4.8]
2.28 8.20
ROLA-070E03 (RCFL-H*3621)
28,600
[8.4]
20,850
[6.1]
7,750
[2.3]
12.50 15.00 73
900
[425]
27,200
[8.0]
3.64
16,200
[4.7]
2.32 8.50
ROLA-070E04 (RCFL-H*3621)
28,600
[8.4]
20,850
[6.1]
7,750
[2.3]
12.50 15.00 73
900
[425]
27,200
[8.0]
3.64
16,200
[4.7]
2.32 8.50
ROLA-115E05 (RCFL-H*3621)
28,600
[8.4]
20,850
[6.1]
7,750
[2.3]
12.50 15.00 73
900
[425]
27,200
[8.0]
3.64
16,200
[4.7]
2.32 8.50
RHKL-HM3617 (RCSL-H*3617)
29,200
[8.6]
21,900
[6.4]
7,300
[2.1]
12.50 15.00 73
1,025 [484]
27,200
[8.0]
3.60
16,300
[4.8]
2.30 8.50
RHSL-HM3017 (RCSL-H*3617)
28,400
[8.3]
20,950
[6.1]
7,450
[2.2]
11.50 13.50 73
950
[448]
27,600
[8.1]
3.46
16,800
[4.9]
2.22 7.70
36
RHLL-HM3617 (RCSL-H*3617)
35,400
[10.4]
25,350
[7.4]
10,050
[2.9]
12.50 15.00 75
1,100 [519]
34,600
[10.1]
3.68
22,200
[6.5]
2.56 8.50
RHBL-FR36T
35,800
[10.5]
26,600
[7.8]
9,200
[2.7]
12.50 15.00 75
1,125 [531]
35,200
[10.3]
3.78
22,600
[6.6]
2.48 8.50
RCFL-H*3617
35,200
[10.3]
25,150
[7.4]
10,050
[2.9]
11.50 14.00 75
1,075 [507]
35,200
[10.3]
3.54
22,800
[6.7]
2.46 8.20
RCFL-H*3617 (RGLE-07?AMK?)
35,800
[10.5]
26,400
[7.7]
9,400
[2.8]
11.50 14.00 75
1,200 [566]
35,000
[10.3]
3.60
22,600
[6.6]
2.48 8.20
RCFL-H*3617 (RGLR-07?AMK?)
35,800
[10.5]
26,400
[7.7]
9,400
[2.8]
11.50 14.00 75
1,200 [566]
35,000
[10.3]
3.58
22,600
[6.6]
2.48 8.20
RCFL-H*3617 (RGLT-07?AME?)
35,800
[10.5]
26,350
[7.7]
9,450
[2.8]
11.50 14.00 75
1,200 [566]
35,000
[10.3]
3.58
22,600
[6.6]
2.48 8.20
RCFL-H*3617 (RGPE-07?AMK?)
35,800
[10.5]
26,500
[7.8]
9,300
[2.7]
11.50 14.00 75
1,225 [578]
35,000
[10.3]
3.56
22,600
[6.6]
2.46 8.20
RCFL-H*3617 (RGPR-07?AMK?)
35,800
[10.5]
26,400
[7.7]
9,400
[2.8]
11.50 14.00 75
1,200 [566]
35,000
[10.3]
3.56
22,600
[6.6]
2.48 8.20
RCFL-H*3617 (RGPT-07?AME?)
35,600
[10.4]
26,100
[7.6]
9,500
[2.8]
11.50 14.00 75
1,175 [554]
35,000
[10.3]
3.56
22,600
[6.6]
2.46 8.20
RCFL-H*3617 (RGTM-06?MAE?)
35,400
[10.4]
25,350
[7.4]
10,050
[2.9]
12.00 14.50 75
1,075 [507]
34,800
[10.2]
3.66
22,400
[6.6]
2.52 8.20
ROCA-070E03 (RCFL-H*3617)
35,800
[10.5]
26,400
[7.7]
9,400
[2.8]
11.50 14.00 75
1,200 [566]
35,000
[10.3]
3.58
22,600
[6.6]
2.48 8.20
ROCA-070E04 (RCFL-H*3617)
35,800
[10.5]
26,400
[7.7]
9,400
[2.8]
11.50 14.00 75
1,200 [566]
35,000
[10.3]
3.58
22,600
[6.6]
2.48 8.20
ROLA-070E03 (RCFL-H*3617)
35,800
[10.5]
26,200
[7.7]
9,600
[2.8]
12.00 14.50 75
1,175 [554]
34,800
[10.2]
3.64
22,400
[6.6]
2.52 8.20
ROLA-070E04 (RCFL-H*3617)
35,800
[10.5]
26,200
[7.7]
9,600
[2.8]
12.00 14.50 75
1,175 [554]
34,800
[10.2]
3.64
22,400
[6.6]
2.52 8.20
RCFL-H*3621
35,200
[10.3]
25,150
[7.4]
10,050
[2.9]
11.50 14.00 75
1,075 [507]
35,200
[10.3]
3.54
22,800
[6.7]
2.46 8.20
RCFL-H*3621 (RGFD-10?ZCM?)
35,800
[10.5]
26,250
[7.7]
9,550
[2.8]
12.00 14.50 75
1,175 [554]
34,800
[10.2]
3.62
22,400
[6.6]
2.50 8.20
RCFL-H*3621 (RGFE-09?ZCM?)
35,800
[10.5]
26,350
[7.7]
9,450
[2.8]
12.00 14.50 75
1,200 [566]
34,800
[10.2]
3.62
22,400
[6.6]
2.50 8.20
RCFL-H*3621 (RGFE-10?ZCM?)
36,000
[10.5]
26,700
[7.8]
9,300
[2.7]
11.50 14.00 75
1,225 [578]
35,000
[10.3]
3.60
22,600
[6.6]
2.48 8.20
Rev.
7/1/10
8 Rheem Heating, Cooling and Water Heating
Performance Data AHRI Standard Conditions (cont.)
Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Page 9
Model Numbers
AHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)
80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Outdoor Air
47°F [8.5°C] DB/
43°F [6°C] WB
DOE High Temp.
Outdoor Air 17°F [–8.5°C] DB/ 15°F [–9.5°C] WB
DOE Low Temp.
DOE
Region
IV
HSPF
Outdoor
Unit
15PJL
Indoor Coil and/or Air Handler
Tot al
Capacity
BTU/H
[kW]
Net
Sens.
BTU/H
[kW]
Net Latent BTU/H
[kW]
EER SEER
Snd. Rate
dB
Indoor
CFM [L/s]
BTU/H
[kW]
COP
BTU/H
[kW]
COP
36
RCFL-H*3621 (RGGE-06?MCK?)
35,800
[10.5]
26,400
[7.7]
9,400
[2.8]
11.50 14.00 75
1,200 [566]
35,000
[10.3]
3.56
22,600
[6.6]
2.46 8.20
RCFL-H*3621 (RGGE-09?ZCM?)
36,000
[10.5]
26,650
[7.8]
9,350
[2.7]
12.00 14.50 75
1,225
[578]
34,800
[10.2]
3.64
22,400
[6.6]
2.50 8.20
RCFL-H*3621 (RGGE-10?ZCM?)
35,800
[10.5]
26,350
[7.7]
9,450
[2.8]
12.00 14.50 75
1,200
[566]
34,800
[10.2]
3.62
22,400
[6.6]
2.50 8.20
RCFL-H*3621 (RGJF-06?MCK?)
35,800
[10.5]
26,400
[7.7]
9,400
[2.8]
11.50 14.00 75
1,200
[566]
35,000
[10.3]
3.56
22,600
[6.6]
2.46 8.20
RCFL-H*3621 (RGJF-09?ZCM?)
36,000
[10.5]
26,650
[7.8]
9,350
[2.7]
12.00 14.50 75
1,225
[578]
34,800
[10.2]
3.64
22,400
[6.6]
2.50 8.20
RCFL-H*3621 (RGJF-10?ZCM?)
35,800
[10.5]
26,350
[7.7]
9,450
[2.8]
12.00 14.50 75
1,200
[566]
34,800
[10.2]
3.62
22,400
[6.6]
2.50 8.20
RCFL-H*3621 (RGLE-07?AMK?)
35,800
[10.5]
26,350
[7.7]
9,450
[2.8]
11.50 14.00 75
1,200 [566]
34,800
[10.2]
3.60
22,400
[6.6]
2.50 8.20
RCFL-H*3621 (RGLE-07?BRQ?)
36,200
[10.6]
26,850
[7.9]
9,350
[2.7]
12.00 14.50 75
1,225 [578]
34,600
[10.1]
3.66
22,200
[6.5]
2.52 8.20
RCFL-H*3621 (RGLE-10?BRM?)
36,200
[10.6]
26,700
[7.8]
9,500
[2.8]
12.50 15.00 75
1,200
[566]
34,600
[10.1]
3.70
22,200
[6.5]
2.54 8.50
RCFL-H*3621 (RGLR-07?AMK?)
35,800
[10.5]
26,350
[7.7]
9,450
[2.8]
11.50 14.00 75
1,200
[566]
35,000
[10.3]
3.60
22,600
[6.6]
2.48 8.20
RCFL-H*3621 (RGLR-07?BRQ?)
36,200
[10.6]
26,800
[7.9]
9,400
[2.8]
12.00 14.50 75
1,225
[578]
34,600
[10.1]
3.66
22,200
[6.5]
2.52 8.20
RCFL-H*3621 (RGLR-10?BRM?)
36,200
[10.6]
26,700
[7.8]
9,500
[2.8]
12.50 15.00 75
1,200
[566]
34,600
[10.1]
3.68
22,200
[6.5]
2.54 8.50
RCFL-H*3621 (RGLT-07?AME?)
35,800
[10.5]
26,350
[7.7]
9,450
[2.8]
12.00 14.50 75
1,200 [566]
35,000
[10.3]
3.58
22,600
[6.6]
2.48 8.20
RCFL-H*3621 (RGLT-07?BRQ?)
36,200
[10.6]
26,700
[7.8]
9,500
[2.8]
12.00 14.50 75
1,200 [566]
34,600
[10.1]
3.66
22,200
[6.5]
2.52 8.20
RCFL-H*3621 (RGLT-10?BRM?)
36,000
[10.5]
26,400
[7.7]
9,600
[2.8]
12.50 15.00 75
1,175
[554]
34,600
[10.1]
3.66
22,200
[6.5]
2.54 8.50
RCFL-H*3621 (RGPE-05?BMK?)
35,800
[10.5]
26,400
[7.7]
9,400
[2.8]
11.50 14.00 75
1,200
[566]
35,000
[10.3]
3.56
22,600
[6.6]
2.46 8.20
RCFL-H*3621 (RGPE-07?AMK?)
35,800
[10.5]
26,500
[7.8]
9,300
[2.7]
11.50 14.00 75
1,225
[578]
35,000
[10.3]
3.58
22,600
[6.6]
2.48 8.20
RCFL-H*3621 (RGPE-07?BRQ?)
36,200
[10.6]
26,800
[7.9]
9,400
[2.8]
12.50 15.00 75
1,225
[578]
34,600
[10.1]
3.66
22,200
[6.5]
2.54 8.50
RCFL-H*3621 (RGPE-10?BRM?)
36,200
[10.6]
26,800
[7.9]
9,400
[2.8]
12.50 15.00 75
1,225
[578]
34,600
[10.1]
3.68
22,200
[6.5]
2.54 8.50
RCFL-H*3621 (RGPR-07?AMK?)
35,800
[10.5]
26,400
[7.7]
9,400
[2.8]
11.50 14.00 75
1,200 [566]
35,000
[10.3]
3.58
22,600
[6.6]
2.48 8.20
RCFL-H*3621 (RGPR-07?BRQ?)
36,200
[10.6]
26,800
[7.9]
9,400
[2.8]
12.50 15.00 75
1,225
[578]
34,600
[10.1]
3.68
22,200
[6.5]
2.54 8.50
RCFL-H*3621 (RGPR-10?BRM?)
36,200
[10.6]
26,850
[7.9]
9,350
[2.7]
12.00 14.50 75
1,225
[578]
34,800
[10.2]
3.64
22,400
[6.6]
2.52 8.20
RCFL-H*3621 (RGPT-07?AME?)
35,800
[10.5]
26,400
[7.7]
9,400
[2.8]
11.50 14.00 75
1,200
[566]
35,000
[10.3]
3.56
22,600
[6.6]
2.46 8.20
RCFL-H*3621 (RGPT-10?BRM?)
36,000
[10.5]
26,350
[7.7]
9,650
[2.8]
12.50 15.00 75
1,175
[554]
34,600
[10.1]
3.68
22,200
[6.5]
2.54 8.50
RCFL-H*3621 (RGRM-09?ZAJ?)
36,000
[10.5]
26,700
[7.8]
9,300
[2.7]
11.50 14.00 75
1,225
[578]
35,000
[10.3]
3.58
22,600
[6.6]
2.48 8.20
Rev.
7/1/10
Rheem Heating, Cooling and Water Heating 9
Performance Data AHRI Standard Conditions (cont.)
Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Page 10
Model Numbers
AHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)
80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Outdoor Air
47°F [8.5°C] DB/
43°F [6°C] WB
DOE High Temp.
Outdoor Air
17°F [–8.5°C] DB/
15°F [–9.5°C] WB
DOE Low Temp.
DOE
Region
IV
HSPF
Outdoor
Unit
15PJL
Indoor Coil and/or Air Handler
Tot al
Capacity
BTU/H
[kW]
Net
Sens.
BTU/H
[kW]
Net Latent BTU/H
[kW]
EER SEER
Snd. Rate
dB
Indoor
CFM [L/s]
BTU/H
[kW]
COP
BTU/H
[kW]
COP
36
RCFL-H*3621 (RGRM-10?ZAJ?)
35,600
[10.4]
25,950
[7.6]
9,650
[2.8]
11.50 14.00 75
1,150 [543]
34,800
[10.2]
3.60
22,400
[6.6]
2.50 8.20
RCFL-H*3621 (RGTM-06?MAE?)
35,400
[10.4]
25,350
[7.4]
10,050
[2.9]
12.00 14.50 75
1,075 [507]
34,600
[10.1]
3.66
22,200
[6.5]
2.52 8.20
RCFL-H*3621 (RGTM-07?RBG?)
35,800
[10.5]
25,950
[7.6]
9,850
[2.9]
12.50 15.00 75
1,125 [531]
34,600
[10.1]
3.68
22,200
[6.5]
2.54 8.50
RCFL-H*3621 (RGTM-09?ZAJ?)
35,400
[10.4]
25,350
[7.4]
10,050
[2.9]
12.50 15.00 75
1,100 [519]
34,600
[10.1]
3.70
22,200
[6.5]
2.56 8.50
ROCA-070E03 (RCFL-H*3621)
35,800
[10.5]
26,400
[7.7]
9,400
[2.8]
11.50 14.00 75
1,200 [566]
34,800
[10.2]
3.60
22,400
[6.6]
2.48 8.20
ROCA-070E04 (RCFL-H*3621)
35,800
[10.5]
26,400
[7.7]
9,400
[2.8]
11.50 14.00 75
1,200 [566]
34,800
[10.2]
3.60
22,400
[6.6]
2.48 8.20
ROLA-070E03 (RCFL-H*3621)
35,800
[10.5]
26,200
[7.7]
9,600
[2.8]
12.00 14.50 75
1,175 [554]
34,600
[10.1]
3.66
22,200
[6.5]
2.52 8.20
ROLA-070E04 (RCFL-H*3621)
35,800
[10.5]
26,200
[7.7]
9,600
[2.8]
12.00 14.50 75
1,175 [554]
34,600
[10.1]
3.66
22,200
[6.5]
2.52 8.20
ROLA-115E05 (RCFL-H*3621)
36,000
[10.5]
26,500
[7.8]
9,500
[2.8]
12.00 14.50 75
1,200 [566]
34,600
[10.1]
3.66
22,200
[6.5]
2.54 8.20
RHKL-HM3617 (RCSL-H*3617)
35,400
[10.4]
25,100
[7.4]
10,300
[3.0]
12.50 15.00 75
1,025 [484]
34,400
[10.1]
3.74
22,000
[6.4]
2.58 8.50
RHSL-HM3617 (RCSL-H*3617)
35,000
[10.3]
25,050
[7.3]
9,950
[2.9]
11.50 13.50 75
1,100 [519]
35,200
[10.3]
3.52
22,800
[6.7]
2.44 7.70
42
RHLL-HM4821 (RCSL-H*4821)
40,000
[11.7]
28,650
[8.4]
11,350
[3.3]
12.50 15.00 77
1,350 [637]
37,400
[11.0]
3.72
24,200
[7.1]
2.60 8.50
RCFL-H*4821
39,500
[11.6]
28,150
[8.2]
11,350
[3.3]
11.50 13.50 77
1,350 [637]
38,000
[11.1]
3.50
25,000
[7.3]
2.46 7.70
RCFL-H*4821 (RGFD-10?ZCM?)
39,000
[11.4]
27,900
[8.2]
11,100
[3.3]
11.50 13.50 77
1,325 [625]
38,000
[11.1]
3.58
24,800
[7.3]
2.50 7.70
RCFL-H*4821 (RGFE-09?ZCM?)
39,500
[11.6]
28,650
[8.4]
10,850
[3.2]
11.50 13.50 77
1,400 [661]
38,000
[11.1]
3.56
24,800
[7.3]
2.48 7.70
RCFL-H*4821 (RGGE-09?ZCM?)
39,500
[11.6]
28,650
[8.4]
10,850
[3.2]
11.50 14.00 77
1,400 [661]
38,000
[11.1]
3.58
24,800
[7.3]
2.52 8.20
RCFL-H*4821 (RGGE-10?ZCM?)
39,500
[11.6]
28,650
[8.4]
10,850
[3.2]
11.50 13.50 77
1,400 [661]
38,000
[11.1]
3.56
24,800
[7.3]
2.50 8.20
RCFL-H*4821 (RGJF-09?ZCM?)
39,500
[11.6]
28,600
[8.4]
10,900
[3.2]
11.50 14.00 77
1,400 [661]
37,800
[11.1]
3.58
24,600
[7.2]
2.52 8.20
RCFL-H*4821 (RGJF-10?ZCM?)
39,500
[11.6]
28,650
[8.4]
10,850
[3.2]
11.50 13.50 77
1,400 [661]
38,000
[11.1]
3.56
24,800
[7.3]
2.50 8.50
RCFL-H*4821 (RGLE-07?BRQ?)
39,500
[11.6]
28,600
[8.4]
10,900
[3.2]
11.50 14.00 77
1,400 [661]
37,800
[11.1]
3.62
24,600
[7.2]
2.54 8.20
RCFL-H*4821 (RGLE-10?BRM?)
40,000
[11.7]
29,050
[8.5]
10,950
[3.2]
12.00 14.50 77
1,400 [661]
37,600
[11.0]
3.66
24,400
[7.1]
2.56 8.20
RCFL-H*4821 (RGLR-07?BRQ?)
40,000
[11.7]
29,200
[8.6]
10,800
[3.2]
11.50 14.00 77
1,425 [672]
37,800
[11.1]
3.62
24,600
[7.2]
2.54 8.20
RCFL-H*4821 (RGLR-10?BRM?)
39,500
[11.6]
28,300
[8.3]
11,200
[3.3]
12.00 14.50 77
1,375 [649]
37,600
[11.0]
3.66
24,400
[7.1]
2.56 8.20
RCFL-H*4821 (RGLT-07?AME?)
39,000
[11.4]
27,900
[8.2]
11,100
[3.3]
11.50 13.50 77
1,350 [637]
38,000
[11.1]
3.56
24,800
[7.3]
2.50 8.20
RCFL-H*4821 (RGLT-07?BRQ?)
40,000
[11.7]
29,350
[8.6]
10,650
[3.1]
11.50 14.00 77
1,450 [684]
37,800
[11.1]
3.60
24,600
[7.2]
2.52 8.20
Rev.
7/1/10
10 Rheem Heating, Cooling and Water Heating
Performance Data AHRI Standard Conditions (cont.)
Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Page 11
Model Numbers
AHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)
80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Outdoor Air
47°F [8.5°C] DB/
43°F [6°C] WB
DOE High Temp.
Outdoor Air 17°F [–8.5°C] DB/ 15°F [–9.5°C] WB
DOE Low Temp.
DOE
Region
IV
HSPF
Outdoor
Unit
15PJL
Indoor Coil and/or Air Handler
Tot al
Capacity
BTU/H
[kW]
Net
Sens.
BTU/H
[kW]
Net Latent BTU/H
[kW]
EER SEER
Snd. Rate
dB
Indoor
CFM [L/s]
BTU/H
[kW]
COP
BTU/H
[kW]
COP
42
RCFL-H*4821 (RGLT-10?BRM?)
40,000
[11.7]
29,200
[8.6]
10,800
[3.2]
11.50 14.00 77
1,425 [672]
37,800
[11.1]
3.62
24,600
[7.2]
2.52 8.20
RCFL-H*4821 (RGPE-07?BRQ?)
39,500
[11.6]
28,550
[8.4]
10,950
[3.2]
12.00 14.50 77
1,400
[661]
37,600
[11.0]
3.64
24,400
[7.1]
2.54 8.20
RCFL-H*4821 (RGPE-10?BRM?)
39,500
[11.6]
28,550
[8.4]
10,950
[3.2]
12.00 14.50 77
1,400
[661]
37,600
[11.0]
3.64
24,600
[7.2]
2.54 8.20
RCFL-H*4821 (RGPR-07?BRQ?)
39,500
[11.6]
28,550
[8.4]
10,950
[3.2]
12.00 14.50 77
1,400
[661]
37,600
[11.0]
3.64
24,400
[7.1]
2.54 8.20
RCFL-H*4821 (RGPR-10?BRM?)
39,500
[11.6]
28,750
[8.4]
10,750
[3.1]
11.50 14.00 77
1,425
[672]
37,800
[11.1]
3.60
24,600
[7.2]
2.52 8.20
RCFL-H*4821 (RGPT-07?AME?)
39,000
[11.4]
27,900
[8.2]
11,100
[3.3]
11.50 13.50 77
1,350
[637]
38,000
[11.1]
3.54
25,000
[7.3]
2.48 8.20
RCFL-H*4821 (RGPT-07?BRQ?)
40,000
[11.7]
28,700
[8.4]
11,300
[3.3]
12.50 15.00 77
1,325 [625]
37,400
[11.0]
3.72
24,200
[7.1]
2.60 8.50
RCFL-H*4821 (RGPT-10?BRM?)
40,000
[11.7]
29,200
[8.6]
10,800
[3.2]
12.00 14.50 77
1,425 [672]
37,800
[11.1]
3.62
24,600
[7.2]
2.54 8.20
RCFL-H*4821 (RGTM-07?RBG?)
39,500
[11.6]
28,300
[8.3]
11,200
[3.3]
12.00 14.50 77
1,325
[625]
37,600
[11.0]
3.64
24,400
[7.1]
2.56 8.20
RCFL-H*4821 (RGTM-09?ZAJ?)
39,500
[11.6]
28,600
[8.4]
10,900
[3.2]
11.50 14.00 77
1,400
[661]
38,000
[11.1]
3.58
24,800
[7.3]
2.52 8.20
ROLA-070E04 (RCFL-H*4821)
39,500
[11.6]
28,300
[8.3]
11,200
[3.3]
11.50 14.00 77
1,375
[649]
37,800
[11.1]
3.62
24,600
[7.2]
2.54 8.20
ROLA-115E05 (RCFL-H*4821)
39,500
[11.6]
28,600
[8.4]
10,900
[3.2]
11.50 14.00 77
1,400
[661]
37,800
[11.1]
3.62
24,600
[7.2]
2.54 8.20
RCFL-H*4824
39,500
[11.6]
28,150
[8.2]
11,350
[3.3]
11.50 13.50 77
1,350 [637]
38,000
[11.1]
3.50
25,000
[7.3]
2.46 7.70
RCFL-H*4824 (RGFD-10?ZCM?)
39,000
[11.4]
27,900
[8.2]
11,100
[3.3]
11.50 13.50 77
1,325 [625]
38,000
[11.1]
3.56
24,800
[7.3]
2.50 7.70
RCFL-H*4824 (RGFE-09?ZCM?)
39,500
[11.6]
28,650
[8.4]
10,850
[3.2]
11.50 13.50 77
1,400
[661]
38,000
[11.1]
3.54
24,800
[7.3]
2.48 7.70
RCFL-H*4824 (RGFE-12?RCM?)
39,500
[11.6]
28,900
[8.5]
10,600
[3.1]
11.50 14.00 77
1,450
[684]
38,000
[11.1]
3.58
24,800
[7.3]
2.52 8.20
RCFL-H*4824 (RGGE-09?ZCM?)
39,500
[11.6]
28,650
[8.4]
10,850
[3.2]
11.50 14.00 77
1,400
[661]
38,000
[11.1]
3.58
24,800
[7.3]
2.52 8.20
RCFL-H*4824 (RGGE-10?ZCM?)
39,500
[11.6]
28,650
[8.4]
10,850
[3.2]
11.50 13.50 77
1,400
[661]
38,000
[11.1]
3.56
24,800
[7.3]
2.50 7.70
RCFL-H*4824 (RGGE-12?RCM?)
39,500
[11.6]
28,300
[8.3]
11,200
[3.3]
11.50 14.00 77
1,375
[649]
37,600
[11.0]
3.64
24,400
[7.1]
2.54 8.20
RCFL-H*4824 (RGJD-12?RCM?)
40,000
[11.7]
29,350
[8.6]
10,650
[3.1]
11.50 14.00 77
1,450 [684]
37,800
[11.1]
3.62
24,600
[7.2]
2.52 8.20
RCFL-H*4824 (RGJF-09?ZCM?)
39,500
[11.6]
28,600
[8.4]
10,900
[3.2]
11.50 14.00 77
1,400
[661]
37,800
[11.1]
3.58
24,600
[7.2]
2.52 8.20
RCFL-H*4824 (RGJF-10?ZCM?)
39,500
[11.6]
28,650
[8.4]
10,850
[3.2]
11.50 13.50 77
1,400
[661]
38,000
[11.1]
3.56
24,800
[7.3]
2.50 7.70
RCFL-H*4824 (RGJF-12?RCM?)
39,500
[11.6]
28,300
[8.3]
11,200
[3.3]
12.00 14.50 77
1,375
[649]
37,600
[11.0]
3.64
24,400
[7.1]
2.56 8.20
RCFL-H*4824 (RGLE-07?BRQ?)
39,500
[11.6]
28,600
[8.4]
10,900
[3.2]
11.50 14.00 77
1,400
[661]
37,800
[11.1]
3.62
24,600
[7.2]
2.54 8.20
RCFL-H*4824 (RGLE-10?BRM?)
40,000
[11.7]
29,050
[8.5]
10,950
[3.2]
12.00 14.50 77
1,400
[661]
37,600
[11.0]
3.66
24,400
[7.1]
2.56 8.20
Rev.
7/1/10
Rheem Heating, Cooling and Water Heating 11
Performance Data AHRI Standard Conditions (cont.)
Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Page 12
Model Numbers
AHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)
80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Outdoor Air
47°F [8.5°C] DB/
43°F [6°C] WB
DOE High Temp.
Outdoor Air
17°F [–8.5°C] DB/
15°F [–9.5°C] WB
DOE Low Temp.
DOE
Region
IV
HSPF
Outdoor
Unit
15PJL
Indoor Coil and/or Air Handler
Tot al
Capacity
BTU/H
[kW]
Net
Sens.
BTU/H
[kW]
Net Latent BTU/H
[kW]
EER SEER
Snd. Rate
dB
Indoor
CFM [L/s]
BTU/H
[kW]
COP
BTU/H
[kW]
COP
42
RCFL-H*4824 (RGLE-12?ARM?)
40,000
[11.7]
29,150
[8.5]
10,850
[3.2]
12.00 14.50 77
1,425 [672]
37,600
[11.0]
3.66
24,400
[7.1]
2.56 8.20
RCFL-H*4824 (RGLR-07?BRQ?)
40,000
[11.7]
29,200
[8.6]
10,800
[3.2]
11.50 14.00 77
1,425 [672]
37,800
[11.1]
3.62
24,600
[7.2]
2.54 8.20
RCFL-H*4824 (RGLR-10?BRM?)
39,500
[11.6]
28,300
[8.3]
11,200
[3.3]
12.00 14.50 77
1,375 [649]
37,600
[11.0]
3.66
24,400
[7.1]
2.56 8.20
RCFL-H*4824 (RGLR-12?ARM?)
40,000
[11.7]
29,200
[8.6]
10,800
[3.2]
12.00 14.50 77
1,425 [672]
37,600
[11.0]
3.64
24,400
[7.1]
2.54 8.20
RCFL-H*4824 (RGLT-07?BRQ?)
40,000
[11.7]
29,350
[8.6]
10,650
[3.1]
11.50 14.00 77
1,450 [684]
37,800
[11.1]
3.60
24,600
[7.2]
2.52 8.20
RCFL-H*4824 (RGLT-10?BRM?)
40,000
[11.7]
29,200
[8.6]
10,800
[3.2]
11.50 14.00 77
1,425 [672]
37,800
[11.1]
3.62
24,600
[7.2]
2.52 8.20
RCFL-H*4824 (RGLT-12?ARM?)
39,500
[11.6]
28,250
[8.3]
11,250
[3.3]
12.00 14.50 77
1,375 [649]
37,600
[11.0]
3.66
24,400
[7.1]
2.56 8.20
RCFL-H*4824 (RGPE-07?BRQ?)
39,500
[11.6]
28,550
[8.4]
10,950
[3.2]
11.50 14.00 77
1,400 [661]
37,800
[11.1]
3.64
24,600
[7.2]
2.54 8.20
RCFL-H*4824 (RGPE-10?BRM?)
39,500
[11.6]
28,550
[8.4]
10,950
[3.2]
11.50 14.00 77
1,400 [661]
37,800
[11.1]
3.64
24,600
[7.2]
2.54 8.20
RCFL-H*4824 (RGPE-12?ARM?)
40,000
[11.7]
29,150
[8.5]
10,850
[3.2]
12.00 14.50 77
1,425 [672]
37,600
[11.0]
3.66
24,400
[7.1]
2.56 8.20
RCFL-H*4824 (RGPR-07?BRQ?)
39,500
[11.6]
28,550
[8.4]
10,950
[3.2]
12.00 14.50 77
1,400 [661]
37,600
[11.0]
3.64
24,400
[7.1]
2.54 8.20
RCFL-H*4824 (RGPR-10?BRM?)
39,500
[11.6]
28,750
[8.4]
10,750
[3.1]
11.50 14.00 77
1,425 [672]
37,800
[11.1]
3.60
24,600
[7.2]
2.52 8.20
RCFL-H*4824 (RGPR-12?ARM?)
39,500
[11.6]
28,550
[8.4]
10,950
[3.2]
12.00 14.50 77
1,400 [661]
37,600
[11.0]
3.64
24,400
[7.1]
2.54 8.20
RCFL-H*4824 (RGPT-07?BRQ?)
40,000
[11.7]
28,700
[8.4]
11,300
[3.3]
12.50 15.00 77
1,325 [625]
37,400
[11.0]
3.72
24,200
[7.1]
2.60 8.50
RCFL-H*4824 (RGPT-10?BRM?)
40,000
[11.7]
29,200
[8.6]
10,800
[3.2]
12.00 14.50 77
1,425 [672]
37,800
[11.1]
3.62
24,600
[7.2]
2.54 8.20
RCFL-H*4824 (RGPT-12?ARM?)
39,500
[11.6]
28,250
[8.3]
11,250
[3.3]
12.00 14.50 77
1,375 [649]
37,600
[11.0]
3.68
24,400
[7.1]
2.58 8.20
RCFL-H*4824 (RGRM-12?RAJ?)
39,500
[11.6]
28,750
[8.4]
10,750
[3.1]
11.50 14.00 77
1,425 [672]
38,000
[11.1]
3.56
24,800
[7.3]
2.50 8.20
RCFL-H*4824 (RGTM-07?RBG?)
39,500
[11.6]
28,300
[8.3]
11,200
[3.3]
12.00 14.50 77
1,325 [625]
37,600
[11.0]
3.64
24,400
[7.1]
2.56 8.20
RCFL-H*4824 (RGTM-09?ZAJ?)
39,500
[11.6]
28,650
[8.4]
10,850
[3.2]
11.50 14.00 77
1,400 [661]
38,000
[11.1]
3.58
24,800
[7.3]
2.50 8.20
RCFL-H*4824 (RGTM-10?RBG?)
39,500
[11.6]
28,700
[8.4]
10,800
[3.2]
11.50 14.00 77
1,425 [672]
37,800
[11.1]
3.62
24,600
[7.2]
2.52 8.20
RCFL-H*4824 (RGTM-10?RBJ?)
39,000
[11.4]
27,400
[8.0]
11,600
[3.4]
12.00 14.50 77
1,275 [602]
37,600
[11.0]
3.68
24,400
[7.1]
2.58 8.20
ROLA-070E04 (RCFL-H*4824)
39,500
[11.6]
28,350
[8.3]
11,150
[3.3]
11.50 14.00 77
1,375 [649]
37,800
[11.1]
3.62
24,600
[7.2]
2.54 8.20
ROLA-115E05 (RCFL-H*4824)
39,500
[11.6]
28,600
[8.4]
10,900
[3.2]
11.50 14.00 77
1,400 [661]
37,800
[11.1]
3.62
24,600
[7.2]
2.52 8.20
RHKL-HM4821 (RCSL-H*4821)
40,000
[11.7]
29,000
[8.5]
11,000
[3.2]
12.50 15.00 77
1,460 [689]
37,600
[11.0]
3.68
24,400
[7.1]
2.58 8.50
RHSL-HM4221 (RCSL-H*4821)
39,000
[11.4]
27,950
[8.2]
11,050
[3.2]
11.50 13.50 77
1,350 [637]
38,500
[11.3]
3.48
25,200
[7.4]
2.46 7.70
Rev.
7/1/10
12 Rheem Heating, Cooling and Water Heating
Performance Data AHRI Standard Conditions (cont.)
Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Page 13
Model Numbers
AHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)
80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Outdoor Air
47°F [8.5°C] DB/
43°F [6°C] WB
DOE High Temp.
Outdoor Air 17°F [–8.5°C] DB/ 15°F [–9.5°C] WB
DOE Low Temp.
DOE
Region
IV
HSPF
Outdoor
Unit
15PJL
Indoor Coil and/or Air Handler
Tot al
Capacity
BTU/H
[kW]
Net
Sens.
BTU/H
[kW]
Net Latent BTU/H
[kW]
EER SEER
Snd. Rate
dB
Indoor
CFM [L/s]
BTU/H
[kW]
COP
BTU/H
[kW]
COP
48
RHLL-HM6024 (RCSL-H*6024)
46,500
[13.6]
35,350
[10.4]
11,150
[3.3]
12.50 15.00 77
1,575
[743]
41,500
[12.2]
3.84
25,000
[7.3]
2.48 8.50
RCFL-H*6024
46,000
[13.5]
34,850
[10.2]
11,150
[3.3]
11.50 14.00 77
1,575
[743]
42,500
[12.5]
3.64
25,800
[7.6]
2.38 8.20
RCFL-H*6024 (RGGE-12?RCM?)
46,000
[13.5]
34,950
[10.2]
11,050
[3.2]
11.50 14.00 77
1,575
[743]
42,000
[12.3]
3.72
25,400
[7.4]
2.44 8.20
RCFL-H*6024 (RGJF-12?RCM?)
46,000
[13.5]
34,950
[10.2]
11,050
[3.2]
11.50 14.00 77
1,575
[743]
42,000
[12.3]
3.72
25,400
[7.4]
2.44 8.20
RCFL-H*6024 (RGLE-07?BRQ?)
46,000
[13.5]
34,950
[10.2]
11,050
[3.2]
11.50 14.00 77
1,600
[755]
42,000
[12.3]
3.70
25,600
[7.5]
2.42 8.20
RCFL-H*6024 (RGLE-10?BRM?)
46,500
[13.6]
35,400
[10.4]
11,100
[3.3]
12.00 14.50 77
1,600
[755]
42,000
[12.3]
3.74
25,400
[7.4]
2.46 8.20
RCFL-H*6024 (RGLE-12?ARM?)
46,500
[13.6]
35,400
[10.4]
11,100
[3.3]
12.00 14.50 77
1,600
[755]
42,000
[12.3]
3.74
25,400
[7.4]
2.46 8.20
RCFL-H*6024 (RGLR-07?BRQ?)
46,500
[13.6]
35,750
[10.5]
10,750
[3.1]
11.50 14.00 77
1,625
[767]
42,000
[12.3]
3.72
25,400
[7.4]
2.44 8.20
RCFL-H*6024 (RGLR-10?BRM?)
46,000
[13.5]
34,900
[10.2]
11,100
[3.3]
11.50 14.00 77
1,575
[743]
42,000
[12.3]
3.72
25,400
[7.4]
2.44 8.20
RCFL-H*6024 (RGLR-12?ARM?)
46,500
[13.6]
35,400
[10.4]
11,100
[3.3]
12.00 14.50 77
1,600
[755]
42,000
[12.3]
3.74
25,400
[7.4]
2.44 8.20
RCFL-H*6024 (RGLT-10?BRM?)
46,500
[13.6]
36,300
[10.6]
10,200
[3.0]
11.50 14.00 77
1,700
[802]
42,500
[12.5]
3.64
25,800
[7.6]
2.38 8.20
RCFL-H*6024 (RGLT-12?ARM?)
46,500
[13.6]
36,250
[10.6]
10,250
[3.0]
11.50 14.00 77
1,700
[802]
42,000
[12.3]
3.68
25,600
[7.5]
2.42 8.20
RCFL-H*6024 (RGPE-07?BRQ?)
46,000
[13.5]
34,950
[10.2]
11,050
[3.2]
11.50 14.00 77
1,600
[755]
42,000
[12.3]
3.72
25,400
[7.4]
2.44 8.20
RCFL-H*6024 (RGPE-10?BRM?)
46,500
[13.6]
35,400
[10.4]
11,100
[3.3]
12.00 14.50 77
1,550
[731]
41,500
[12.2]
3.76
25,200
[7.4]
2.46 8.20
RCFL-H*6024 (RGPE-12?ARM?)
46,500
[13.6]
35,750
[10.5]
10,750
[3.1]
12.00 14.50 77
1,625
[767]
42,000
[12.3]
3.74
25,400
[7.4]
2.44 8.20
RCFL-H*6024 (RGPR-07?BRQ?)
46,500
[13.6]
35,750
[10.5]
10,750
[3.1]
11.50 14.00 77
1,625
[767]
42,000
[12.3]
3.72
25,400
[7.4]
2.44 8.20
RCFL-H*6024 (RGPR-10?BRM?)
46,000
[13.5]
35,300
[10.3]
10,700
[3.1]
11.50 14.00 77
1,625
[767]
42,000
[12.3]
3.66
25,600
[7.5]
2.40 8.20
RCFL-H*6024 (RGPR-12?ARM?)
46,500
[13.6]
35,400
[10.4]
11,100
[3.3]
12.00 14.50 77
1,575
[743]
42,000
[12.3]
3.74
25,400
[7.4]
2.44 8.20
RCFL-H*6024 (RGPT-07?BRQ?)
46,500
[13.6]
35,300
[10.3]
11,200
[3.3]
12.00 14.50 77
1,550
[731]
41,500
[12.2]
3.82
25,000
[7.3]
2.48 8.50
RCFL-H*6024 (RGPT-10?BRM?)
46,500
[13.6]
36,300
[10.6]
10,200
[3.0]
11.50 14.00 77
1,700
[802]
42,000
[12.3]
3.66
25,800
[7.6]
2.40 8.20
RCFL-H*6024 (RGPT-12?ARM?)
46,500
[13.6]
36,250
[10.6]
10,250
[3.0]
11.50 14.00 77
1,700
[802]
42,000
[12.3]
3.68
25,600
[7.5]
2.40 8.20
RCFL-H*6024 (RGRM-12?RAJ?)
46,000
[13.5]
34,950
[10.2]
11,050
[3.2]
11.50 14.00 77
1,550
[731]
42,000
[12.3]
3.68
25,600
[7.5]
2.42 8.20
RCFL-H*6024 (RGTM-07?RBG?)
45,500
[13.3]
33,750
[9.9]
11,750
[3.4]
11.50 14.00 77
1,475
[696]
42,000
[12.3]
3.74
25,400
[7.4]
2.46 8.20
RCFL-H*6024 (RGTM-09?ZAJ?)
46,000
[13.5]
34,950
[10.2]
11,050
[3.2]
11.50 14.00 77
1,550
[731]
42,000
[12.3]
3.68
25,600
[7.5]
2.42 8.20
RCFL-H*6024 (RGTM-10?RBJ?)
46,000
[13.5]
35,300
[10.3]
10,700
[3.1]
11.50 14.00 77
1,625
[767]
42,000
[12.3]
3.68
25,600
[7.5]
2.42 8.20
Rev.
7/1/10
Rheem Heating, Cooling and Water Heating 13
Performance Data AHRI Standard Conditions (cont.)
Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Page 14
Model Numbers
AHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)
80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Outdoor Air
47°F [8.5°C] DB/
43°F [6°C] WB
DOE High Temp.
Outdoor Air 17°F [–8.5°C] DB/ 15°F [–9.5°C] WB
DOE Low Temp.
DOE
Region
IV
HSPF
Outdoor
Unit
15PJL
Indoor
Coil and/or
Air Handler
Tot al
Capacity
BTU/H
[kW]
Net
Sens.
BTU/H
[kW]
Net Latent BTU/H
[kW]
EER SEER
Snd. Rate
dB
Indoor
CFM
[L/s]
BTU/H
[kW]
COP
BTU/H
[kW]
COP
48
ROLA-115E05 (RCFL-H*6024)
46,000
[13.5]
34,950
[10.2]
11,050
[3.2]
11.50 14.00 77
1,600 [755]
42,000
[12.3]
3.68
25,600
[7.5]
2.42 8.20
RHKL-HM6024 (RCSL-H*6024)
47,000
[13.8]
35,750
[10.5]
11,250
[3.3]
12.50 15.00 77
1,600 [755]
41,500
[12.2]
3.88
24,800
[7.3]
2.54 8.50
RHSL-HM6024 (RCSL-H*6024)
46,000
[13.5]
36,300
[10.6]
9,700
[2.8]
11.00 13.00 77
1,625 [767]
43,000
[12.6]
3.46
26,600
[7.8]
2.30 7.70
60
RHLL-HM6024 (RCSL-H*6024)
52,000
[15.2]
37,300
[10.9]
14,700
[4.3]
12.50 15.00 77
1,575 [743]
50,500
[14.8]
3.84
31,400
[9.2]
2.62 8.50
RCFL-H*6024
51,500
[15.1]
36,800
[10.8]
14,700
[4.3]
12.00 14.50 77
1,575 [743]
51,500
[15.1]
3.70
32,200
[9.4]
2.52 8.20
RCFL-H*6024 (RGGE-12?RCM?)
51,500
[15.1]
36,900
[10.8]
14,600
[4.3]
12.00 14.50 77
1,575 [743]
51,000
[14.9]
3.78
31,800
[9.3]
2.56 8.20
RCFL-H*6024 (RGJF-12?RCM?)
51,500
[15.1]
36,900
[10.8]
14,600
[4.3]
12.00 14.50 77
1,575 [743]
51,000
[14.9]
3.78
31,800
[9.3]
2.56 8.20
RCFL-H*6024 (RGLE-07?BRQ?)
51,500
[15.1]
36,950
[10.8]
14,550
[4.3]
12.00 14.50 77
1,600 [755]
51,000
[14.9]
3.76
32,000
[9.4]
2.54 8.20
RCFL-H*6024 (RGLE-10?BRM?)
52,000
[15.2]
37,350
[10.9]
14,650
[4.3]
12.00 14.50 77
1,600 [755]
51,000
[14.9]
3.80
31,800
[9.3]
2.58 8.20
RCFL-H*6024 (RGLE-12?ARM?)
52,000
[15.2]
37,350
[10.9]
14,650
[4.3]
12.00 14.50 77
1,600 [755]
51,000
[14.9]
3.80
31,800
[9.3]
2.58 8.20
RCFL-H*6024 (RGLR-07?BRQ?)
52,000
[15.2]
37,750
[11.1]
14,250
[4.2]
12.00 14.50 77
1,625 [767]
51,000
[14.9]
3.76
31,800
[9.3]
2.56 8.20
RCFL-H*6024 (RGLR-10?BRM?)
51,500
[15.1]
36,900
[10.8]
14,600
[4.3]
12.00 14.50 77
1,575 [743]
51,000
[14.9]
3.78
31,800
[9.3]
2.56 8.20
RCFL-H*6024 (RGLR-12?ARM?)
52,000
[15.2]
37,350
[10.9]
14,650
[4.3]
12.00 14.50 77
1,600 [755]
51,000
[14.9]
3.80
31,800
[9.3]
2.58 8.20
RCFL-H*6024 (RGLT-12?ARM?)
52,500
[15.4]
38,800
[11.4]
13,700
[4.0]
12.00 14.50 77
1,700 [802]
51,000
[14.9]
3.74
32,000
[9.4]
2.54 8.20
RCFL-H*6024 (RGPE-07?BRQ?)
51,500
[15.1]
36,900
[10.8]
14,600
[4.3]
12.00 14.50 77
1,600 [755]
51,000
[14.9]
3.76
31,800
[9.3]
2.56 8.20
RCFL-H*6024 (RGPE-10?BRM?)
52,000
[15.2]
37,750
[11.1]
14,250
[4.2]
12.00 14.50 77
1,625 [767]
51,000
[14.9]
3.76
31,800
[9.3]
2.56 8.20
RCFL-H*6024 (RGPE-12?ARM?)
52,000
[15.2]
37,700
[11.0]
14,300
[4.2]
12.00 14.50 77
1,625 [767]
51,000
[14.9]
3.78
31,800
[9.3]
2.58 8.20
RCFL-H*6024 (RGPR-07?BRQ?)
52,000
[15.2]
37,750
[11.1]
14,250
[4.2]
12.00 14.50 77
1,625 [767]
51,000
[14.9]
3.78
31,800
[9.3]
2.56 8.20
RCFL-H*6024 (RGPR-10?BRM?)
51,500
[15.1]
36,550
[10.7]
14,950
[4.4]
12.00 14.50 77
1,525 [720]
51,000
[14.9]
3.78
31,800
[9.3]
2.58 8.20
RCFL-H*6024 (RGPR-12?ARM?)
52,000
[15.2]
37,350
[10.9]
14,650
[4.3]
12.00 14.50 77
1,575 [743]
51,000
[14.9]
3.80
31,600
[9.3]
2.58 8.20
RCFL-H*6024 (RGPT-10?BRM?)
52,000
[15.2]
38,350
[11.2]
13,650
[4.0]
12.00 14.50 77
1,700 [802]
51,000
[14.9]
3.72
32,200
[9.4]
2.52 8.20
RCFL-H*6024 (RGPT-12?ARM?)
52,500
[15.4]
38,800
[11.4]
13,700
[4.0]
12.00 14.50 77
1,700 [802]
51,000
[14.9]
3.74
32,000
[9.4]
2.54 8.20
RCFL-H*6024 (RGTM-07?RBG?)
51,000
[14.9]
35,700
[10.5]
15,300
[4.5]
12.00 14.50 77
1,475 [696]
51,000
[14.9]
3.80
31,800
[9.3]
2.58 8.20
RCFL-H*6024 (RGTM-09?ZAJ?)
51,500
[15.1]
36,950
[10.8]
14,550
[4.3]
12.00 14.50 77
1,550 [731]
51,000
[14.9]
3.74
32,000
[9.4]
2.54 8.20
RHKL-HM6024 (RCSL-H*6024)
53,000
[15.5]
39,950
[11.7]
13,050
[3.8]
12.50 15.00 77
1,800 [849]
50,500
[14.8]
3.82
31,600
[9.3]
2.58 8.50
RHSL-HM6024 (RCSL-H*6024)
51,500
[15.1]
38,400
[11.3]
13,100
[3.8]
11.50 13.50 77
1,750 [826]
52,000
[15.2]
3.56
33,000
[9.7]
2.42 7.70
Rev.
7/1/10
14 Rheem Heating, Cooling and Water Heating
Performance Data AHRI Standard Conditions (cont.)
Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Page 15
Rheem Heating, Cooling and Water Heating 15
Electrical and Physical Data
Model
Number
15PJL
ELECTRICAL PHYSICAL
Phase Frequency (Hz) Voltage (Volts)
Compressor
Fan Motor
Full Load
Amperes
(FLA)
Minimum
Circuit
Ampacity
Amperes
Fuse or HACR
Circuit Breaker
Outdoor Coil
Refrig.
Per Circuit Oz. [g]
Weight
Rated Load
Amperes
(RLA)
Locked Rotor
Amperes
(LRA)
Minimum
Amperes
Maximum
Amperes
Face Area
Sq. Ft. [m
2
]
No.
Rows
CFM [L/s]
Net
Lbs. [kg]
Shipping Lbs. [kg]
30 1-60-208/230 12.8/12.8 64 1 18/18 25/25 25/25
16.39 [1.52] 1 2595 [1225] 114.5 [3246] 169 [76.7] 181 [82.1]
Rev. 7/1/10
18 1-60-208/230 9/9 48 0.8 13/13 15/15 20/20
13.72 [1.27] 1 2590 [1222]
95.6 [2710] 154 [69.9] 164 [74.4]
60 1-60-208/230 21.4/21.4 135 2.8 30/30 35/35 50/50
21.85 [2.03] 2 3925 [1852]
279 [7910] 264 [119.8] 278 [126.1]
42 1-60-208/230 17.9/17.9 112 1.9 25/25 30/30 40/40
21.85 [2.03] 1 3575 [1687]
146.5 [4153] 210 [95.3] 224 [101.6]
48 1-60-208/230 19.9/19.9 109 1 26/26 35/35 45/45
21.85 [2.03] 1 3575 [1687]
229.2 [6498] 210 [95.3] 224 [101.6]
36 1-60-208/230 16.7/16.7 79 1.4 23/23 30/30 35/35
21.85 [2.03] 1 3000 [1416]
138 [3912] 193 [87.5] 207 [93.9]
24 1-60-208/230 13.5/13.5 58.3 0.8 18/18 25/25 30/30
13.72 [1.27] 1 2590 [1222]
94.2 [2671] 155 [70.3] 165 [74.8]
GENERAL TERMS OF LIMITED WARRANTY
Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable periods stated, in accordance with the terms of the limited warranty.
*For Complete Details of the Limited Warranty, Including Applicable
Terms and Conditions, See the Product Warranty Card.
Conditional Parts Warranty*
(Registration Required) ............................Ten (10) Years
Conditional Compressor*
(Registration Required) ............................Ten (10) Years
Limited Parts* ............................................Five (5) Years
BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER.
NOTES:
20 Fins per inch.Factory charged for 15 ft. line set.
[ ] Designates Metric Conversions
Page 16
16 Rheem Heating, Cooling and Water Heating
Unit Dimensions
[ ] Designates Metric Conversions
L
H
w
SEE DETAIL A
15 SEER
Cooling Capacity
18, 24 30 36, 42, 48, 60
Height “H” (In.) [mm] 261/4 [666.7] 273/8 [695.3] 353/8 [898.5] Length “L” (In.) [mm] 275/8 [701.6] 315/8 [803.2] 315/8 [803.2] Width “W” (In.) [mm]
275/
8 [701.6]
315/
8 [803.2]
315/
8 [803.2]
Page 17
Rheem Heating, Cooling and Water Heating 17
Heat Pump Refrigerant Line Size Information
NOTES: *Standard line size N/A = Application not recommended.
NOTES: [ ] Designates Metric Conversions *Standard line size N/A = Using suction line larger than shown in chart will result in poor oil return and is not recommended.
System
Capacity
11/2 To n
2 Ton
Ton
21/2
3 Ton
31/2 To n
4 Ton
5 Ton
Line Size
Connection
Size
(Inch I.D.)
[mm]
3/8"
[9.53]
3/8"
[9.53]
3/8"
[9.53]
3/8"
[9.53]
3/8"
[9.53]
3/8"
[9.53]
3/8"
[9.53]
Line Size
(Inch O.D.)
[mm]
1/4 [6.35] 5/16 [7.94] 3/8* [9.53]
5/16 [7.94]
1/4 [6.35] 5/16 [7.94] 3/8* [9.53] 5/16 [7.94] 3/8* [9.53] 5/16 [7.94] 3/8* [9.53] 3/8* [9.53] 1/2 [12.7] 3/8* [9.53] 1/2 [12.7]
Outdoor Unit Above or Below Indoor Coil (Heat Pumps Only)
25 [7.62] 50 [15.24] 75 [22.86] 100 [30.48] 125 [38.10] 150 [45.72]
25 [7.62] 40 [12.19] 25 [7.62] 9 [2.74] N/A N/A 25 [7.62] 50 [15.24] 62 [18.90] 25 [7.62] 50 [15.24] 75 [22.86] 23 [7.01] N/A N/A N/A N/A N/A1/4 [6.35] 25 [7.62] 36 [10.97] 29 [8.84] 25 [7.62] 50 [15.24] 72 [21.95] 25 [7.62] N/A N/A N/A N/A N/A 25 [7.62] 49 [14.94] 38 [11.58] 25 [7.62] 50 [15.24] 68 [20.73] 25 [7.62] 50 [15.24] 37 [11.28] 22 [6.71] 7 [2.13] N/A 25 [7.62] 50 [15.24] 68 [20.73] 63 [19.20] 58 [17.68] 53 [16.15] 25 [7.62] 23 [7.01] 4 [1.22] N/A N/A N/A 25 [7.62] 50 [15.24] 43 [13.11] 36 [10.97] 30 [9.14] 24 [7.32] 25 [7.62] 46 [14.02] 38 [11.58] 30 [9.14] 22 [6.71] 15 [4.57] 25 [7.62] 50 [15.24] 56 [17.07] 55 [16.76] 53 [16.15] 52 [15.85] 25 [7.62] 50 [15.24] 56 [17.07] 44 [13.41] 32 [9.75] 20 [6.10] 25 [7.62] 50 [15.24] 75 [22.86] 81 [24.69] 79 [24.08] 76 [23.16]
Suction Line Length/Size versus Capacity Multiplier (R-410A)
1
/2 To n
2
5
/8" [15.88 mm] O.D. Opt.
3
/4" [19.05 mm] O.D. Std.*
7
/8" [22.23 mm] O.D. Opt.
1.00
1.00
1.00
0.96
0.98
0.99
0.94
0.96
0.97
0.91
0.93
0.95
Suction Line
Connection Size
Suction Line Run—
Feet [m]
25' [7.62]
50' [15.24]
100' [30.48]
150' [45.72]
Optional Standard Optional
Optional Standard Optional
Optional Standard Optional
Optional Standard Optional
2 Ton
3/4" [19.05] I.D.
5
/8" [15.88 mm] O.D. Opt.
3
/4" [19.05 mm] O.D. Std.*
1.00
1.00 —
0.98
0.99 —
0.95
0.96 —
0.92
0.93 —
1.00
1.00 —
0.98
0.99 —
0.95
0.96 —
0.92
0.94 —
Liquid Line Sizing (R410A)
Total Equivalent Length—Feet [m]
Maximum Vertical Separation—Feet [m]
58 [17.68] 53 [16.15] 49 [14.94] 72 [21.95]
23 [7.01] 16 [4.88] 9 [2.74] 70 [21.34]
27 [8.23] 17 [5.18] 6 [1.83] 65 [19.81]
7/8" [22.23] I.D.
3
/4" [19.05 mm] O.D. Std.*
7
/8" [22.23 mm] O.D. Opt.
1.00
1.00 —
0.98
0.99 —
0.96
0.97 —
0.94
0.95 —
7
/8" [22.23 mm] O.D. Std.*
3
/4" [19.05 mm] O.D. Opt.
1
/2 To n3 Ton11/2 To nUnit Size
1.00
1.00 —
0.99
0.99 —
0.96
0.98 —
0.94
0.96 —
70 [21.34] 68 [20.73]
68 [20.73] 65 [19.81]3/8* [9.53]
62 [18.90] 58 [17.68]
5 Ton4 Ton3
7
/8" [22.23 mm] O.D. Std.*
1
1
/8" [28.58 mm] O.D. Opt.
1.00
1.00 —
0.99
0.99 —
0.96
0.98 —
0.95
0.96 —
1.00
1.00 —
0.99
0.99 —
0.97
0.98 —
0.94
0.97 —
Page 18
18 Rheem Heating, Cooling and Water Heating
NOTES
Page 19
Rheem Heating, Cooling and Water Heating 19
NOTES
Page 20
Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices.
Rheem Heating, Cooling and Water Heating
P.O. Box 17010, Fort Smith, AR 72917
“In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.”
PRINTED IN U.S.A. 1-11 DC FORM NO. P11-789 REV. 1
Supersedes Form No. P11-789
Loading...