Features
35" Maximum Unit Height.
Coils constructed with copper tubing and enhanced alu-
Strong, attractive cabinet—louvered design protects the
coil from damage.
Expansion Valves with Internal Check Valve—Provides
for quieter refrigerant metering.
Enhanced Demand Defrost Control
Factory Installed Low Pressure Control
Non-Cycling Reversing Valve
Hot Gas Muffler
Service Valves
Grille/motor mount for quiet fan operation.
Easily accessible control box.
Bi-Directional Filter Drier (Field Installed)
Certified and rated under AHRI Standard 240.
U.L listed.
Optional High Pressure Control (Field-Installed: 1.5-4 ton/
Factory Installed: 5 ton only)
Heat Pump Thermostat Warning Light Kit
Accessories/Options
Low Ambient Control (Model No. RXAD-A08)
Outdoor Thermostats (Model No. RXPT-A01, A02,
A03 or A04)
Heat Pump Monitor (Model No. RXPM-B01)
Thermostats and Subbases
(Available through the PROSTOCK®department)
Compressor Time Delay Control (Model No.
RXMD-B01)
Blower Time Delay Control (Model No. RXMD-C04)
RXMD-C04 is not required if the outdoor unit is matched with a Rheem Value Series furnace or air handler, or if the furnace or air handler used has a blower off time delay built-in.
Sound Enclosure*
Start Components*
*Available through the PROSTOCK
®
department.
Applications
Rheem Value Series remote heat pumps offer comfort and depend ability for single, multi-family and light commercial applications.
15 SEER
HEAT PUMPS
15PJL SERIES
Featuring New Industry Standard R-410A Refrigerant
(IN CERTAIN
MATCHED SYSTEMS)
Model Numbers
AHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)
80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Outdoor Air
47°F [8.5°C] DB/
43°F [6°C] WB
DOE High Temp.
Outdoor Air 17°F [–8.5°C] DB/ 15°F [–9.5°C] WB
DOE Low Temp.
DOE
Region
IV
HSPF
Outdoor
Unit
15PJL
Indoor Coil and/or Air Handler
Tot al
Capacity
BTU/H
[kW]
Net
Sens.
BTU/H
[kW]
Net Latent BTU/H
[kW]
EER SEER
Snd. Rate
dB
Indoor
CFM [L/s]
BTU/H
[kW]
COP
BTU/H
[kW]
COP
18
RHLL-HM2417 (RCSL-H*2417)
18,500
[5.4]
13,400
[3.9]
5,100
[1.5]
12.50 15.00 76
600
[283]
17,700
[5.2]
3.68
10,800
[3.2]
2.38 8.50
RHBL-FR24T
19,600
[5.7]
14,900
[4.4]
4,700
[1.4]
12.50 15.00 76
600
[283]
16,500
[4.8]
3.48
9,500
[2.8]
2.04 8.20
RCFL-H*2414
18,200
[5.3]
13,100
[3.8]
5,100
[1.5]
11.50 13.50 76
600
[283]
18,200
[5.3]
3.42
11,300
[3.3]
2.24 7.70
RCFL-H*2417
18,200
[5.3]
13,100
[3.8]
5,100
[1.5]
11.00 13.50 76
600
[283]
18,200
[5.3]
3.42
11,300
[3.3]
2.24 7.70
RCFL-H*2417 (RGFD-06?MCK?)
18,400
[5.4]
13,350
[3.9]
5,050
[1.5]
12.50 15.00 76
600
[283]
17,800
[5.2]
3.64
10,900
[3.2]
2.36 8.20
RCFL-H*2417 (RGFD-07?MCK?)
18,400
[5.4]
13,350
[3.9]
5,050
[1.5]
12.50 15.00 76
600
[283]
17,800
[5.2]
3.64
10,900
[3.2]
2.36 8.20
RCFL-H*2417 (RGFE-06?MCK?)
18,500
[5.4]
13,400
[3.9]
5,100
[1.5]
12.50 15.00 76
575
[271]
17,700
[5.2]
3.68
10,800
[3.2]
2.38 8.20
RCFL-H*2417 (RGFE-07?MCK?)
18,400
[5.4]
13,300
[3.9]
5,100
[1.5]
12.50 15.00 76
600
[283]
17,700
[5.2]
3.68
10,800
[3.2]
2.38 8.20
RCFL-H*2417 (RGGD-06?MCK?)
18,500
[5.4]
13,400
[3.9]
5,100
[1.5]
12.50 15.00 76
600
[283]
17,700
[5.2]
3.68
10,800
[3.2]
2.38 8.20
RCFL-H*2417 (RGGD-07?MCK?)
18,400
[5.4]
13,300
[3.9]
5,100
[1.5]
12.50 15.00 76
625
[295]
17,700
[5.2]
3.66
10,800
[3.2]
2.36 8.20
RCFL-H*2417 (RGGE-06?MCK?)
18,400
[5.4]
13,300
[3.9]
5,100
[1.5]
12.50 15.00 76
600
[283]
17,700
[5.2]
3.66
10,800
[3.2]
2.38 8.20
RCFL-H*2417 (RGGE-07?MCK?)
18,500
[5.4]
13,400
[3.9]
5,100
[1.5]
12.50 15.00 76
575
[271]
17,700
[5.2]
3.68
10,800
[3.2]
2.38 8.20
RCFL-H*2417 (RGJD-06?MCK?)
18,500
[5.4]
13,400
[3.9]
5,100
[1.5]
12.50 15.00 76
600
[283]
17,700
[5.2]
3.68
10,800
[3.2]
2.38 8.20
RCFL-H*2417 (RGJD-07?MCK?)
18,400
[5.4]
13,300
[3.9]
5,100
[1.5]
12.50 15.00 76
625
[295]
17,700
[5.2]
3.66
10,800
[3.2]
2.36 8.20
RCFL-H*2417 (RGJF-06?MCK?)
18,500
[5.4]
13,400
[3.9]
5,100
[1.5]
12.50 15.00 76
625
[295]
17,700
[5.2]
3.68
10,800
[3.2]
2.38 8.20
RCFL-H*2417 (RGJF-07?MCK?)
18,500
[5.4]
13,400
[3.9]
5,100
[1.5]
12.50 15.00 76
575
[271]
17,700
[5.2]
3.68
10,800
[3.2]
2.38 8.20
RCFL-H*2417 (RGLE-07?AMK?)
18,500
[5.4]
13,400
[3.9]
5,100
[1.5]
12.50 15.00 76
600
[283]
17,700
[5.2]
3.70
10,800
[3.2]
2.38 8.20
RCFL-H*2417 (RGLR-07?AMK?)
18,500
[5.4]
13,400
[3.9]
5,100
[1.5]
12.50 15.00 76
600
[283]
17,700
[5.2]
3.68
10,800
[3.2]
2.38 8.20
RCFL-H*2417 (RGLT-07?AME?)
18,900
[5.5]
13,950
[4.1]
4,950
[1.5]
12.50 15.00 76
675
[319]
17,700
[5.2]
3.66
10,800
[3.2]
2.36 8.20
Rev.
7/1/10
2 Rheem Heating, Cooling and Water Heating
Model Identification Number
15 P J 18
NOMINAL COOLING CAPACITY
18 = 18,000 BTU/HR [5.28 kW] 24 = 24,000 BTU/HR [7.03 kW] 30 = 30,000 BTU/HR [8.79 kW] 36 = 36,000 BTU/HR [10.55 kW] 42 = 42,000 BTU/HR [12.31 kW] 48 = 48,000 BTU/HR [14.07 kW] 60 = 60,000 BTU/HR [17.58 kW]
L A 01
15 SEER P = HEAT PUMP VOLTAGE
J = 208-230 SINGLE PHASE
L = 1ST DESIGN
(R-410A)
CABINET
A = FULL METAL JACKET
RHEEM
VALUE SERIES
Performance Data AHRI Standard Conditions
Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Model Numbers
AHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)
80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Outdoor Air
47°F [8.5°C] DB/
43°F [6°C] WB
DOE High Temp.
Outdoor Air
17°F [–8.5°C] DB/
15°F [–9.5°C] WB
DOE Low Temp.
DOE
Region
IV
HSPF
Outdoor
Unit
15PJL
Indoor Coil and/or Air Handler
Tot al
Capacity
BTU/H
[kW]
Net
Sens.
BTU/H
[kW]
Net Latent BTU/H
[kW]
EER SEER
Snd. Rate
dB
Indoor
CFM [L/s]
BTU/H
[kW]
COP
BTU/H
[kW]
COP
18
RCFL-H*2417 (RGPE-05?BMK?)
18,500
[5.4]
13,400
[3.9]
5,100
[1.5]
12.50 15.00 76
575
[271]
17,700
[5.2]
3.68
10,800
[3.2]
2.38 8.20
RCFL-H*2417 (RGPE-07?AMK?)
18,500
[5.4]
13,400
[3.9]
5,100
[1.5]
12.50 15.00 76
625
[295]
17,700
[5.2]
3.68
10,800
[3.2]
2.38 8.20
RCFL-H*2417 (RGPL-05?BMK?)
18,400
[5.4]
13,350
[3.9]
5,050
[1.5]
12.50 15.00 76
600
[283]
17,800
[5.2]
3.64
10,900
[3.2]
2.36 8.20
RCFL-H*2417 (RGPR-05?BMK?)
18,400
[5.4]
13,350
[3.9]
5,050
[1.5]
12.50 15.00 76
600
[283]
17,800
[5.2]
3.64
10,900
[3.2]
2.36 8.20
RCFL-H*2417 (RGPR-07?AMK?)
18,500
[5.4]
13,400
[3.9]
5,100
[1.5]
12.50 15.00 76
600
[283]
17,700
[5.2]
3.68
10,800
[3.2]
2.38 8.20
RCFL-H*2417 (RGPT-05?BMK?)
18,700
[5.5]
13,700
[4.0]
5,000
[1.5]
12.50 15.00 76
650
[307]
17,800
[5.2]
3.64
10,900
[3.2]
2.36 8.20
RCFL-H*2417 (RGPT-07?AME?)
18,400
[5.4]
13,300
[3.9]
5,100
[1.5]
12.50 15.00 76
625
[295]
17,700
[5.2]
3.66
10,800
[3.2]
2.36 8.20
RCFL-H*2417 (RGRM-04?MAE?)
18,400
[5.4]
13,350
[3.9]
5,050
[1.5]
12.50 15.00 76
575
[271]
17,800
[5.2]
3.66
10,900
[3.2]
2.36 8.20
RCFL-H*2417 (RGRM-06?MAE?)
18,400
[5.4]
13,300
[3.9]
5,100
[1.5]
12.50 15.00 76
600
[283]
17,700
[5.2]
3.66
10,800
[3.2]
2.36 8.20
RCFL-H*2417 (RGRM-07?MAE?)
18,300
[5.4]
13,250
[3.9]
5,050
[1.5]
12.50 15.00 76
625
[295]
17,800
[5.2]
3.62
10,900
[3.2]
2.34 8.20
RCFL-H*2417 (RGTM-06?MAE?)
18,500
[5.4]
13,400
[3.9]
5,100
[1.5]
12.50 15.00 76
575
[271]
17,700
[5.2]
3.70
10,800
[3.2]
2.38 8.20
ROCA-070E03 (RCFL-H*2417)
18,500
[5.4]
13,400
[3.9]
5,100
[1.5]
12.50 15.00 76
600
[283]
17,700
[5.2]
3.68
10,800
[3.2]
2.38 8.20
ROLA-070E03 (RCFL-H*2417)
18,400
[5.4]
13,350
[3.9]
5,050
[1.5]
12.50 15.00 76
600
[283]
17,800
[5.2]
3.66
10,900
[3.2]
2.36 8.20
RHKL-HM2417 (RCSL-H*2417)
18,700
[5.5]
13,700
[4.0]
5,000
[1.5]
12.50 15.00 76
650
[307]
17,700
[5.2]
3.66
10,800
[3.2]
2.36 8.20
RHSL-HM1817 (RCSL-H*2417)
18,100
[5.3]
13,100
[3.8]
5,000
[1.5]
11.50 14.00 76
600
[283]
18,100
[5.3]
3.48
11,200
[3.3]
2.26 8.00
24
RHLL-HM2417 (RCSL-H*2417)
23,600
[6.9]
16,800
[4.9]
6,800
[2.0]
12.50 15.00 74
775
[366]
21,600
[6.3]
3.58
12,400
[3.6]
2.22 8.50
RHBL-FR24T
25,000
[7.3]
19,350
[5.7]
5,650
[1.7]
12.50 15.00 74
850
[401]
21,400
[6.3]
3.56
12,300
[3.6]
2.14 8.20
RCFL-A*2414
23,200
[6.8]
16,400
[4.8]
6,800
[2.0]
11.00 13.50 74
775
[366]
22,200
[6.5]
3.34
13,000
[3.8]
2.06 7.70
RCFL-H*2417
23,200
[6.8]
16,400
[4.8]
6,800
[2.0]
11.00 13.50 74
775
[366]
22,200
[6.5]
3.34
13,000
[3.8]
2.06 7.70
RCFL-H*2417 (RGFD-06?MCK?)
23,200
[6.8]
16,500
[4.8]
6,700
[2.0]
11.50 14.00 74
800
[378]
21,800
[6.4]
3.46
12,600
[3.7]
2.12 8.20
RCFL-H*2417 (RGFD-07?MCK?)
23,200
[6.8]
16,500
[4.8]
6,700
[2.0]
11.50 14.00 74
800
[378]
21,800
[6.4]
3.48
12,600
[3.7]
2.12 8.20
RCFL-H*2417 (RGFE-06?MCK?)
23,400
[6.9]
16,650
[4.9]
6,750
[2.0]
12.00 14.50 74
800
[378]
21,800
[6.4]
3.50
12,500
[3.7]
2.14 8.20
RCFL-H*2417 (RGFE-07?MCK?)
23,600
[6.9]
17,000
[5.0]
6,600
[1.9]
12.00 14.50 74
825
[389]
21,800
[6.4]
3.50
12,500
[3.7]
2.14 8.20
RCFL-H*2417 (RGGD-06?MCK?)
23,400
[6.9]
16,650
[4.9]
6,750
[2.0]
12.00 14.50 74
800
[378]
21,800
[6.4]
3.52
12,500
[3.7]
2.14 8.20
RCFL-H*2417 (RGGE-06?MCK?)
23,600
[6.9]
16,950
[5.0]
6,650
[1.9]
12.50 15.00 74
825
[389]
21,600
[6.3]
3.54
12,400
[3.6]
2.16 8.20
Rev.
7/1/10
Rheem Heating, Cooling and Water Heating 3
Performance Data AHRI Standard Conditions (cont.)
Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Model Numbers
AHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)
80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Outdoor Air
47°F [8.5°C] DB/
43°F [6°C] WB
DOE High Temp.
Outdoor Air 17°F [–8.5°C] DB/ 15°F [–9.5°C] WB
DOE Low Temp.
DOE
Region
IV
HSPF
Outdoor
Unit
15PJL
Indoor Coil and/or Air Handler
Tot al
Capacity
BTU/H
[kW]
Net
Sens.
BTU/H
[kW]
Net Latent BTU/H
[kW]
EER SEER
Snd. Rate
dB
Indoor
CFM [L/s]
BTU/H
[kW]
COP
BTU/H
[kW]
COP
24
RCFL-H*2417 (RGGE-07?MCK?)
23,400
[6.9]
16,650
[4.9]
6,750
[2.0]
12.50 15.00 74
750
[354]
21,600
[6.3]
3.54
12,400
[3.6]
2.16 8.20
RCFL-H*2417 (RGJD-06?MCK?)
23,400
[6.9]
16,650
[4.9]
6,750
[2.0]
12.00 14.50 74
800
[378]
21,800
[6.4]
3.52
12,500
[3.7]
2.14 8.20
RCFL-H*2417 (RGJD-07?MCK?)
23,400
[6.9]
16,700
[4.9]
6,700
[2.0]
12.00 14.50 74
800
[378]
21,800
[6.4]
3.50
12,600
[3.7]
2.14 8.20
RCFL-H*2417 (RGJF-06?MCK?)
23,600
[6.9]
16,950
[5.0]
6,650
[1.9]
12.50 15.00 74
825
[389]
21,600
[6.3]
3.54
12,400
[3.6]
2.16 8.20
RCFL-H*2417 (RGJF-07?MCK?)
23,400
[6.9]
16,650
[4.9]
6,750
[2.0]
12.50 15.00 74
750
[354]
21,600
[6.3]
3.54
12,400
[3.6]
2.16 8.20
RCFL-H*2417 (RGLE-07?AMK?)
23,600
[6.9]
16,850
[4.9]
6,750
[2.0]
12.50 15.00 74
750
[354]
21,600
[6.3]
3.56
12,400
[3.6]
2.16 8.50
RCFL-H*2417 (RGLR-07?AMK?)
23,400
[6.9]
16,650
[4.9]
6,750
[2.0]
12.00 14.50 74
800
[378]
21,600
[6.3]
3.54
12,400
[3.6]
2.16 8.20
RCFL-H*2417 (RGLT-07?AME?)
23,800
[7.0]
17,250
[5.1]
6,550
[1.9]
12.00 14.50 74
850
[401]
21,800
[6.4]
3.50
12,500
[3.7]
2.14 8.20
RCFL-H*2417 (RGPE-05?BMK?)
23,400
[6.9]
16,650
[4.9]
6,750
[2.0]
12.50 15.00 74
750
[354]
21,600
[6.3]
3.54
12,400
[3.6]
2.16 8.20
RCFL-H*2417 (RGPE-07?AMK?)
23,600
[6.9]
17,000
[5.0]
6,600
[1.9]
12.50 15.00 74
825
[389]
21,600
[6.3]
3.54
12,500
[3.7]
2.16 8.20
RCFL-H*2417 (RGPR-05?BMK?)
23,200
[6.8]
16,500
[4.8]
6,700
[2.0]
12.00 14.50 74
775
[366]
21,800
[6.4]
3.48
12,600
[3.7]
2.12 8.20
RCFL-H*2417 (RGPR-07?AMK?)
23,400
[6.9]
16,650
[4.9]
6,750
[2.0]
12.50 15.00 74
750
[354]
21,600
[6.3]
3.56
12,400
[3.6]
2.16 8.20
RCFL-H*2417 (RGPT-05?BMK?)
23,800
[7.0]
17,250
[5.1]
6,550
[1.9]
12.00 14.50 74
850
[401]
21,800
[6.4]
3.48
12,600
[3.7]
2.12 8.20
RCFL-H*2417 (RGPT-07?AME?)
23,800
[7.0]
17,250
[5.1]
6,550
[1.9]
12.00 14.50 74
850
[401]
21,800
[6.4]
3.50
12,600
[3.7]
2.14 8.20
RCFL-H*2417 (RGRM-04?MAE?)
23,400
[6.9]
16,650
[4.9]
6,750
[2.0]
12.00 14.50 74
750
[354]
21,600
[6.3]
3.52
12,500
[3.7]
2.14 8.20
RCFL-H*2417 (RGRM-06?MAE?)
23,400
[6.9]
16,650
[4.9]
6,750
[2.0]
12.00 14.50 74
775
[366]
21,600
[6.3]
3.52
12,500
[3.7]
2.14 8.20
RCFL-H*2417 (RGRM-07?MAE?)
23,200
[6.8]
16,500
[4.8]
6,700
[2.0]
11.50 14.00 74
800
[378]
21,800
[6.4]
3.46
12,600
[3.7]
2.12 8.20
RCFL-H*2417 (RGTM-06?MAE?)
23,400
[6.9]
16,650
[4.9]
6,750
[2.0]
12.50 15.00 74
750
[354]
21,600
[6.3]
3.56
12,400
[3.6]
2.16 8.50
ROCA-070E03 (RCFL-H*2417)
23,400
[6.9]
16,650
[4.9]
6,750
[2.0]
12.00 14.50 74
800
[378]
21,600
[6.3]
3.54
12,400
[3.6]
2.16 8.20
ROCA-070E04 (RCFL-H*2417)
23,400
[6.9]
16,650
[4.9]
6,750
[2.0]
12.00 14.50 74
800
[378]
21,600
[6.3]
3.54
12,400
[3.6]
2.16 8.20
ROLA-070E03 (RCFL-H*2417)
23,400
[6.9]
16,650
[4.9]
6,750
[2.0]
12.00 14.50 74
800
[378]
21,600
[6.3]
3.54
12,500
[3.7]
2.16 8.20
ROLA-070E04 (RCFL-H*2417)
23,400
[6.9]
16,650
[4.9]
6,750
[2.0]
12.00 14.50 74
800
[378]
21,600
[6.3]
3.54
12,500
[3.7]
2.16 8.20
RHKL-HM2417 (RCSL-H*2417)
23,200
[6.8]
17,200
[5.0]
6,000
[1.8]
12.50 15.00 74
825
[389]
21,800
[6.4]
3.52
12,500
[3.7]
2.14 8.50
RHSL-HM2417 (RCSL-H*2417)
23,000
[6.7]
16,350
[4.8]
6,650
[1.9]
11.00 13.50 74
800
[378]
22,000
[6.4]
3.36
12,900
[3.8]
2.08 7.70
Rev.
7/1/10
4 Rheem Heating, Cooling and Water Heating
Performance Data AHRI Standard Conditions (cont.)
Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Model Numbers
AHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)
80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Outdoor Air
47°F [8.5°C] DB/
43°F [6°C] WB
DOE High Temp.
Outdoor Air
17°F [–8.5°C] DB/
15°F [–9.5°C] WB
DOE Low Temp.
DOE
Region
IV
HSPF
Outdoor
Unit
15PJL
Indoor Coil and/or Air Handler
Tot al
Capacity
BTU/H
[kW]
Net
Sens.
BTU/H
[kW]
Net Latent BTU/H
[kW]
EER SEER
Snd. Rate
dB
Indoor
CFM [L/s]
BTU/H
[kW]
COP
BTU/H
[kW]
COP
30
RHLL-HM3617 (RCSL-H*3617)
28,800
[8.4]
21,250
[6.2]
7,550
[2.2]
12.50 15.00 73
950
[448]
27,200
[8.0]
3.62
16,300
[4.8]
2.30 8.50
RHBL-FR36T
29,000
[8.5]
22,300
[6.5]
6,700
[2.0]
12.50 15.00 73
975
[460]
28,000
[8.2]
3.74
16,700
[4.9]
2.42 8.50
RCFL-H*3617
28,600
[8.4]
21,050
[6.2]
7,550
[2.2]
11.50 13.50 73
950
[448]
27,800
[8.1]
3.42
16,900
[5.0]
2.20 7.70
RCFL-H*3617 (RGFD-06?MCK?)
28,600
[8.4]
21,300
[6.2]
7,300
[2.1]
11.50 13.50 73
1,000 [472]
27,600
[8.1]
3.46
16,800
[4.9]
2.22 7.70
RCFL-H*3617 (RGFD-07?MCK?)
28,800
[8.4]
21,500
[6.3]
7,300
[2.1]
11.50 14.00 73
1,000 [472]
27,600
[8.1]
3.50
16,600
[4.9]
2.24 8.20
RCFL-H*3617 (RGFE-06?MCK?)
28,800
[8.4]
21,500
[6.3]
7,300
[2.1]
11.50 14.00 73
1,000 [472]
27,600
[8.1]
3.50
16,600
[4.9]
2.24 8.20
RCFL-H*3617 (RGFE-07?MCK?)
28,800
[8.4]
21,600
[6.3]
7,200
[2.1]
11.50 14.00 73
1,025 [484]
27,600
[8.1]
3.48
16,700
[4.9]
2.24 8.20
RCFL-H*3617 (RGGD-07?MCK?)
29,000
[8.5]
21,800
[6.4]
7,200
[2.1]
11.50 14.00 73
1,025 [484]
27,600
[8.1]
3.50
16,600
[4.9]
2.24 8.20
RCFL-H*3617 (RGGE-06?MCK?)
28,800
[8.4]
21,500
[6.3]
7,300
[2.1]
11.50 14.00 73
1,000 [472]
27,400
[8.0]
3.52
16,600
[4.9]
2.26 8.20
RCFL-H*3617 (RGGE-07?MCK?)
29,000
[8.5]
21,750
[6.4]
7,250
[2.1]
11.50 14.00 73
1,025 [484]
27,400
[8.0]
3.52
16,600
[4.9]
2.26 8.20
RCFL-H*3617 (RGJF-06?MCK?)
28,800
[8.4]
21,500
[6.3]
7,300
[2.1]
11.50 14.00 73
1,000 [472]
27,400
[8.0]
3.52
16,600
[4.9]
2.26 8.20
RCFL-H*3617 (RGJF-07?MCK?)
29,000
[8.5]
21,750
[6.4]
7,250
[2.1]
11.50 14.00 73
1,025 [484]
27,400
[8.0]
3.52
16,600
[4.9]
2.26 8.20
RCFL-H*3617 (RGLE-07?AMK?)
29,200
[8.6]
21,950
[6.4]
7,250
[2.1]
12.00 14.50 73
1,025 [484]
27,400
[8.0]
3.56
16,400
[4.8]
2.28 8.20
RCFL-H*3617 (RGLR-07?AMK?)
29,000
[8.5]
21,750
[6.4]
7,250
[2.1]
12.00 14.50 73
1,025 [484]
27,400
[8.0]
3.54
16,500
[4.8]
2.28 8.20
RCFL-H*3617 (RGLT-07?AME?)
29,200
[8.6]
22,050
[6.5]
7,150
[2.1]
12.00 14.50 73
1,050 [495]
27,400
[8.0]
3.52
16,500
[4.8]
2.26 8.20
RCFL-H*3617 (RGPE-05?BMK?)
28,600
[8.4]
21,100
[6.2]
7,500
[2.2]
11.50 14.00 73
975
[460]
27,400
[8.0]
3.54
16,500
[4.8]
2.26 8.20
RCFL-H*3617 (RGPE-07?AMK?)
29,000
[8.5]
21,650
[6.3]
7,350
[2.2]
12.00 14.50 73
1,000 [472]
27,400
[8.0]
3.54
16,500
[4.8]
2.28 8.20
RCFL-H*3617 (RGPR-05?BMK?)
28,800
[8.4]
21,500
[6.3]
7,300
[2.1]
11.50 14.00 73
1,000 [472]
27,600
[8.1]
3.48
16,700
[4.9]
2.24 8.20
RCFL-H*3617 (RGPR-07?AMK?)
29,000
[8.5]
21,650
[6.3]
7,350
[2.2]
12.00 14.50 73
1,000 [472]
27,400
[8.0]
3.54
16,500
[4.8]
2.26 8.20
RCFL-H*3617 (RGPT-05?BMK?)
29,000
[8.5]
21,850
[6.4]
7,150
[2.1]
11.50 14.00 73
1,050 [495]
27,600
[8.1]
3.48
16,700
[4.9]
2.24 8.20
RCFL-H*3617 (RGPT-07?AME?)
29,200
[8.6]
22,050
[6.5]
7,150
[2.1]
11.50 14.00 73
1,050 [495]
27,600
[8.1]
3.50
16,600
[4.9]
2.24 8.20
RCFL-H*3617 (RGRM-04?MAE?)
28,800
[8.4]
21,600
[6.3]
7,200
[2.1]
11.50 13.50 73
1,025 [484]
27,600
[8.1]
3.46
16,800
[4.9]
2.22 7.70
RCFL-H*3617 (RGRM-06?MAE?)
28,800
[8.4]
21,500
[6.3]
7,300
[2.1]
11.50 14.00 73
1,000 [472]
27,600
[8.1]
3.48
16,700
[4.9]
2.24 8.20
RCFL-H*3617 (RGRM-07?MAE?)
28,400
[8.3]
20,950
[6.1]
7,450
[2.2]
11.50 13.50 73
950
[448]
27,600
[8.1]
3.48
16,700
[4.9]
2.24 7.70
RCFL-H*3617 (RGTM-06?MAE?)
28,600
[8.4]
20,850
[6.1]
7,750
[2.3]
12.00 14.50 73
900
[425]
27,200
[8.0]
3.60
16,300
[4.8]
2.30 8.20
Rev.
7/1/10
Rheem Heating, Cooling and Water Heating 5
Performance Data AHRI Standard Conditions (cont.)
Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Model Numbers
AHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)
80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Outdoor Air
47°F [8.5°C] DB/
43°F [6°C] WB
DOE High Temp.
Outdoor Air
17°F [–8.5°C] DB/
15°F [–9.5°C] WB
DOE Low Temp.
DOE
Region
IV
HSPF
Outdoor
Unit
15PJL
Indoor Coil and/or Air Handler
Tot al
Capacity
BTU/H
[kW]
Net
Sens.
BTU/H
[kW]
Net Latent BTU/H
[kW]
EER SEER
Snd. Rate
dB
Indoor
CFM [L/s]
BTU/H
[kW]
COP
BTU/H
[kW]
COP
30
ROCA-070E03 (RCFL-H*3617)
29,000
[8.5]
21,650
[6.3]
7,350
[2.2]
12.00 14.50 73
1,000 [472]
27,400
[8.0]
3.56
16,400
[4.8]
2.28 8.20
ROCA-070E04 (RCFL-H*3617)
29,000
[8.5]
21,650
[6.3]
7,350
[2.2]
12.00 14.50 73
1,000 [472]
27,400
[8.0]
3.56
16,400
[4.8]
2.28 8.20
ROLA-070E03 (RCFL-H*3617)
28,800
[8.4]
21,250
[6.2]
7,550
[2.2]
12.00 14.50 73
975
[460]
27,200
[8.0]
3.58
16,400
[4.8]
2.30 8.20
ROLA-070E04 (RCFL-H*3617)
28,800
[8.4]
21,250
[6.2]
7,550
[2.2]
12.00 14.50 73
975
[460]
27,200
[8.0]
3.58
16,400
[4.8]
2.30 8.20
RCFL-H*3621
28,600
[8.4]
21,050
[6.2]
7,550
[2.2]
11.50 13.50 73
950
[448]
27,800
[8.1]
3.42
16,900
[5.0]
2.20 7.70
RCFL-H*3621 (RGFD-06?MCK?)
28,600
[8.4]
21,300
[6.2]
7,300
[2.1]
11.50 13.50 73
1,000 [472]
27,600
[8.1]
3.46
16,700
[4.9]
2.22 7.70
RCFL-H*3621 (RGFD-07?MCK?)
28,800
[8.4]
21,500
[6.3]
7,300
[2.1]
11.50 14.00 73
1,000 [472]
27,600
[8.1]
3.50
16,600
[4.9]
2.24 8.20
RCFL-H*3621 (RGFE-06?MCK?)
28,800
[8.4]
21,500
[6.3]
7,300
[2.1]
11.50 14.00 73
1,000 [472]
27,400
[8.0]
3.52
16,600
[4.9]
2.26 8.20
RCFL-H*3621 (RGFE-07?MCK?)
29,000
[8.5]
21,800
[6.4]
7,200
[2.1]
11.50 14.00 73
1,025 [484]
27,600
[8.1]
3.50
16,600
[4.9]
2.24 8.20
RCFL-H*3621 (RGFE-09?ZCM?)
28,800
[8.4]
21,250
[6.2]
7,550
[2.2]
12.00 14.50 73
975
[460]
27,200
[8.0]
3.58
16,400
[4.8]
2.30 8.20
RCFL-H*3621 (RGFE-10?ZCM?)
29,000
[8.5]
21,750
[6.4]
7,250
[2.1]
12.00 14.50 73
1,025 [484]
27,400
[8.0]
3.54
16,500
[4.8]
2.28 8.20
RCFL-H*3621 (RGGD-07?MCK?)
29,000
[8.5]
21,800
[6.4]
7,200
[2.1]
11.50 14.00 73
1,025 [484]
27,600
[8.1]
3.50
16,600
[4.9]
2.24 8.50
RCFL-H*3621 (RGGE-06?MCK?)
28,800
[8.4]
21,450
[6.3]
7,350
[2.2]
11.50 14.00 73
1,000 [472]
27,400
[8.0]
3.52
16,500
[4.8]
2.26 8.50
RCFL-H*3621 (RGGE-07?MCK?)
29,000
[8.5]
21,750
[6.4]
7,250
[2.1]
11.50 14.00 73
1,025 [484]
27,400
[8.0]
3.52
16,600
[4.9]
2.26 8.20
RCFL-H*3621 (RGGE-09?ZCM?)
29,200
[8.6]
21,950
[6.4]
7,250
[2.1]
12.00 14.50 73
1,025 [484]
27,400
[8.0]
3.56
16,400
[4.8]
2.28 8.20
RCFL-H*3621 (RGGE-10?ZCM?)
29,000
[8.5]
21,650
[6.3]
7,350
[2.2]
12.00 14.50 73
1,000 [472]
27,200
[8.0]
3.58
16,400
[4.8]
2.28 8.20
RCFL-H*3621 (RGJF-06?MCK?)
28,800
[8.4]
21,450
[6.3]
7,350
[2.2]
11.50 14.00 73
1,000 [472]
27,400
[8.0]
3.52
16,500
[4.8]
2.26 8.50
RCFL-H*3621 (RGJF-07?MCK?)
29,000
[8.5]
21,750
[6.4]
7,250
[2.1]
11.50 14.00 73
1,025 [484]
27,400
[8.0]
3.52
16,600
[4.9]
2.26 8.50
RCFL-H*3621 (RGJF-09?ZCM?)
29,200
[8.6]
21,950
[6.4]
7,250
[2.1]
12.00 14.50 73
1,025 [484]
27,400
[8.0]
3.56
16,400
[4.8]
2.28 8.50
RCFL-H*3621 (RGJF-10?ZCM?)
29,000
[8.5]
21,650
[6.3]
7,350
[2.2]
12.00 14.50 73
1,000 [472]
27,200
[8.0]
3.58
16,400
[4.8]
2.28 8.50
RCFL-H*3621 (RGLE-07?AMK?)
29,200
[8.6]
21,900
[6.4]
7,300
[2.1]
12.00 14.50 73
1,025 [484]
27,400
[8.0]
3.56
16,400
[4.8]
2.28 8.20
RCFL-H*3621 (RGLE-07?BRQ?)
29,200
[8.6]
21,900
[6.4]
7,300
[2.1]
12.50 15.00 73
1,025 [484]
27,200
[8.0]
3.60
16,300
[4.8]
2.30 8.50
RCFL-H*3621 (RGLE-10?BRM?)
29,400
[8.6]
22,200
[6.5]
7,200
[2.1]
12.50 15.00 73
1,050 [495]
27,200
[8.0]
3.62
16,300
[4.8]
2.30 8.50
RCFL-H*3621 (RGLR-07?AMK?)
29,200
[8.6]
21,950
[6.4]
7,250
[2.1]
12.00 14.50 73
1,025 [484]
27,400
[8.0]
3.56
16,400
[4.8]
2.28 8.50
RCFL-H*3621 (RGLR-07?BRQ?)
29,200
[8.6]
21,800
[6.4]
7,400
[2.2]
12.50 15.00 73
1,000 [472]
27,200
[8.0]
3.62
16,300
[4.8]
2.30 8.50
Rev.
7/1/10
6 Rheem Heating, Cooling and Water Heating
Performance Data AHRI Standard Conditions (cont.)
Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Loading...