FORM NO. P11-774 REV. 3
Supersedes Form No. P11-774 Rev. 2
Features
■ Coils constructed with copper tubing and enhanced alu-
minum fins.
■ Includes factory installed low pressure control.
■ Strong, attractive cabinet—louvered design protects the
coil from damage.
■ Expansion Valves with Internal Check Valve—Provides
for quieter refrigerant metering.
■ Demand Defrost Control
■ Non-Cycling Reversing Valve
■ Hot Gas Muffler
■ Service Valves
■ Grille/motor mount for quiet fan operation.
■ Easily accessible control box.
■ Bi-Directional Filter Drier (shipped – not installed)
■ Certified and rated under A.R.I. Standard 240.
■ U.L listed.
Accessories/Options
■ Low Ambient Control (Model No. RXAD-A08)
■ Outdoor Thermostats (Model No. RXPT-A01, A02,
A03 or A04)
■ Heat Pump Monitor (Model No. RXPM-B01)
■ Thermostats and Subbases
(Available through the PROSTOCK®department)
■ Compressor Time Delay Control (Model No.
RXMD-B01)
■ Blower Time Delay Control (Model No. RXMD-C04)
RXMD-C04 is not required if the outdoor unit is matched
with a Rheem Value Series furnace or air handler, or if
the furnace or air handler used has a blower off time
delay built-in.
■ Sound Enclosure*
■ High Pressure Control (Model No. RXAB-A07)
■ Start Components*
*Available through the PROSTOCK®department.
Applications
Rheem Value Series remote heat pumps offer comfort and
dependability for single, multi-family and light commercial
applications.
13 SEER
HEAT PUMPS
13PJL SERIES
Featuring
Earth-Friendly
R-410A Refrigerant
earth friendly refrigerant
13.0
2 Rheem Heating, Cooling and Water Heating
Model Identification Number
13 P J 18
NOMINAL COOLING CAPACITY
18 = 18,000 BTU/HR [5.28 kW]
24 = 24,000 BTU/HR [7.03 kW]
30 = 30,000 BTU/HR [8.79 kW]
36 = 36,000 BTU/HR [10.55 kW]
42 = 42,000 BTU/HR [12.31 kW]
48 = 48,000 BTU/HR [14.07 kW]
60 = 60,000 BTU/HR [17.58 kW]
L A 01
13 SEER P = HEAT PUMP VOLTAGE
J = 208-230 SINGLE PHASE
L = R-410A CABINET
A = FULL METAL JACKET
RHEEM
VALUE SERIES
Performance Data ARI Standard Conditions
Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.
➀ Highest sales volume tested combination required by D.O.E. test procedures.
[ ] Designates Metric Conversions
ARI Cooling Performance ARI Htg. Performance (70°F [21.0°C] Indoor)
Model Numbers
[19.5°C] WB Indoor Air 95°F [35.0°C] DB Outdoor Air
Outdoor
Unit
13PJL
Rev.
3/31/09
18
24
30
Indoor
Coil and/or
Air Handler
RHSL-HM1817
(RCSL-H*2417A*) ➀
RCFL-H*2414A*
RCFL-H*2417A*
RBHP-17
(RCHL-24A2)
RHLL-HM2417
(RCSL-H*2417A*)
RHSL-HM2417
(RCSL-H*2417A*) ➀
RCFL-H*2414A*
RCFL-H*2417A*
RBHP-17
(RCHL-24A2)
RHLL-HM2417
(RCSL-H*2417A*)
RHSL-HM3017
(RCSL-H*3617A*) ➀
RCFL-H*3617A*
RCFL-H*3617C*
RCFL-H*3621A*
RCFL-H*3621C*
RBHP-21
(RCHL-36A1)
RHLL-HM3617
(RCSL-H*3617A*)
RHLL-HM3617
(RCSL-H*3617C*)
RHSL-HM3017
(RCSL-H*3617C*)
Total
Capacity
BTU/H
[kW]
18,200
[5.3]
18,100
[5.3]
18,100
[5.3]
17,800
[5.2]
18,900
[5.5]
24,200
[7.1]
24,200
[7.1]
24,200
[7.1]
22,400
[6.6]
24,800
[7.3]
28,600
[8.4]
28,400
[8.3]
28,400
[8.3]
28,400
[8.3]
28,400
[8.3]
28,600
[8.4]
28,800
[8.4]
28,800
[8.4]
28,600
[8.4]
Sens.
BTU/H
[kW]
13,100
[3.8]
12,950
[3.8]
12,950
[3.8]
12,900
[3.8]
13,750
[4.0]
17,050
[5.0]
17,050
[5.0]
17,050
[5.0]
15,850
[4.6]
17,650
[5.2]
21,450
[6.3]
21,250
[6.2]
21,250
[6.2]
21,250
[6.2]
21,250
[6.2]
21,200
[6.2]
21,650
[6.3]
21,650
[6.3]
21,450
[6.3]
80°F [26.5°C] DB/67°F
Net
Latent
BTU/H
[kW]
5,100
[1.5]
5,150
[1.5]
5,150
[1.5]
4,900
[1.4]
5,150
[1.5]
7,150
[2.1]
7,150
[2.1]
7,150
[2.1]
6,550
[1.9]
7,150
[2.1]
7,150
[2.1]
7,150
[2.1]
7,150
[2.1]
7,150
[2.1]
7,150
[2.1]
7,400
[2.2]
7,150
[2.1]
7,150
[2.1]
7,150
[2.1]
Net
dB
Indoor
CFM
[L/s]
600
[283]
600
[283]
600
[283]
600
[283]
800
[378]
800
[378]
800
[378]
800
[378]
800
[378]
1,000
[472]
1,000
[472]
1,000
[472]
1,000
[472]
1,000
[472]
1,000
[472]
1,000
[472]
1,000
[472]
1,000
[472]
Snd.
EER
SEER
11.35 13.00 76
11.10 13.00 76
11.10 13.00 76
12.00 14.00 76
12.00 14.00 76 615 [290]
10.90 13.00 74
10.75 13.00 74
10.75 13.00 74
11.00 13.00 74
12.00 14.00 74
11.40 13.00 73
11.00 13.00 73
11.00 13.00 73
11.00 13.00 73
11.00 13.00 73
12.00 14.00 73
12.00 14.00 73
12.00 14.00 73
11.40 13.00 73
Rate
Outdoor Air
47°F DB/43°F WB
[8.5°C/6.0°C]
DOE High Temp.
BTU/H
[kW]
16,900
[5.0]
17,000
[5.0]
17,000
[5.0]
16,500
[4.8]
16,500
[4.8]
22,800
[6.7]
22,800
[6.7]
22,800
[6.7]
22,200
[6.5]
22,200
[6.5]
27,800
[8.1]
27,400
[8.0]
27,400
[8.0]
27,400
[8.0]
27,400
[8.0]
26,800
[7.9]
26,800
[7.9]
26,800
[7.9]
27,800
[8.1]
COP
3.42
3.36
3.36
3.64
3.62
3.50
3.44
3.44
3.60
3.72
3.74
3.58
3.58
3.58
3.58
3.82
3.78
3.78
3.74
Outdoor Air
17°F DB/15°F WB
[–8.5°C/–9.5°C]
DOE Low Temp.
BTU/H
[kW]
8,700
[2.5]
8,800
[2.6]
8,800
[2.6]
9,100
[2.7]
8,300
[2.4]
13,600
[4.0]
13,800
[4.0]
13,800
[4.0]
14,500
[4.2]
13,100
[3.8]
15,600
[4.6]
15,000
[4.4]
15,000
[4.4]
15,000
[4.4]
15,000
[4.4]
14,500
[4.2]
14,400
[4.2]
14,400
[4.2]
15,600
[4.6]
COP
2.18 7.70
2.08 7.70
2.08 7.70
2.44 8.20
2.22 8.20
2.24 7.70
2.22 7.70
2.22 7.70
2.54 7.70
2.36 8.20
2.52 8.50
2.36 8.00
2.36 8.00
2.36 8.00
2.36 8.00
2.56 9.00
2.44 9.00
2.44 9.00
2.52 8.50
Region
DOE
IV
HSPF
Rheem Heating, Cooling and Water Heating 3
Performance Data ARI Standard Conditions (cont.)
Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.
➀ Highest sales volume tested combination required by D.O.E. test procedures.
[ ] Designates Metric Conversions
ARI Cooling Performance
Model Numbers
Outdoor
Unit
13PJL
Rev.
3/31/09
36
42
48
60
Indoor
Coil and/or
Air Handler
RHSL-HM3617
(RCSL-H*3617A*) ➀
RCFL-H*3617A*
RCFL-H*3617C*
RCFL-H*3621A*
RCFL-H*3621C*
RBHP-21
(RCHL-36A1)
RHLL-HM3617
(RCSL-H*3617A*)
RHLL-HM3617
(RCSL-H*3617C*)
RHSL-HM3617
(RCSL-H*3617C*)
RHSL-HM3621
(RCSL-H*3621A*)
RHSL-HM3621
(RCSL-H*3621C*)
RHSL-HM4221
(RCSL-H*4821A*) ➀
RCFL-H*4821A*
RCFL-H*4824A*
RBHP-24
(RCHL-48A1)
RHLL-HM4821
(RCSL-H*4821A*)
RHSL-HM4821
(RCFL-H*4821A*) ➀
RHSL-HM4821
(RCSL-H*4821A*) ➀
RCFL-H*4821A*
RCFL-H*4824A*
RHLL-HM4821
(RCSL-H*4821A*)
RHLL-HM4824
(RCSL-H*4824A*)
RHSL-HM4824
(RCSL-H*4824A*)
RHLL-HM6024
(RCSL-H*6024A*) ➀
Capacity
BTU/H
34,400
[10.1]
33,400
33,400
33,400
33,400
35,400
[10.4]
35,000
[10.3]
35,000
[10.3]
34,400
[10.1]
34,400
[10.1]
34,400
[10.1]
41,000
[12.0]
41,000
[12.0]
41,000
[12.0]
40,000
[11.7]
42,000
[12.3]
46,500
[13.6]
46,500
[13.6]
45,500
[13.3]
45,500
[13.3]
47,500
[13.9]
48,000
[14.1]
46,500
[13.6]
58,500
[17.1]
80°F [126.5°C] DB/67°F [119.5°C] WB Indoor Air
95°F[135.0°C] DB Outdoor Air
Total
[kW]
[9.8]
[9.8]
[9.8]
[9.8]
Net
Sens.
BTU/H
[kW]
25,350
[7.4]
24,350
[7.1]
24,350
[7.1]
24,350
[7.1]
24,350
[7.1]
25,650
[7.5]
25,950
[7.6]
25,950
[7.6]
25,350
[7.4]
25,350
[7.4]
25,350
[7.4]
30,350
[8.9]
30,350
[8.9]
30,350
[8.9]
28,250
[8.3]
31,350
[9.2]
33,950
[9.9]
33,950
[9.9]
32,950
[9.7]
32,950
[9.7]
34,950
[10.2]
36,500
[10.7]
33,950
[9.9]
41,750
[12.2]
Net
Latent
BTU/H
[kW]
9,050
[2.7]
9,050
[2.7]
9,050
[2.7]
9,050
[2.7]
9,050
[2.7]
9,750
[2.9]
9,050
[2.7]
9,050
[2.7]
9,050
[2.7]
9,050
[2.7]
9,050
[2.7]
10,650
[3.1]
10,650
[3.1]
10,650
[3.1]
11,750
[3.4]
10,650
[3.1]
12,550
[3.7]
12,550
[3.7]
12,550
[3.7]
12,550
[3.7]
12,550
[3.7]
11,500
[3.4]
12,550
[3.7]
16,750
[4.9]
Snd.
EER
SEER
11.10 13.00 75
10.95 13.00 75
10.95 13.00 75
10.95 13.00 75
10.95 13.00 75
11.75 13.50 75
12.00 14.00 75
12.00 14.00 75
11.10 13.00 75
11.10 13.00 75
11.10 13.00 75
11.05 13.00 77
10.90 13.00 77
10.90 13.00 77
12.00 14.00 77
12.00 14.00 77
10.90 13.00 77
10.90 13.00 77
10.85 13.00 77
10.85 13.00 77
12.00 14.00 77
12.00 14.00 77
10.90 13.00 77
10.90 13.00 77
Rate
dB
Indoor
CFM
[L/s]
1,200
[566]
1,075
[507]
1,075
[507]
1,075
[507]
1,075
[507]
1,175
[554]
1,200
[566]
1,200
[566]
1,200
[566]
1,200
[566]
1,200
[566]
1,400
[661]
1,400
[661]
1,400
[661]
1,400
[661]
1,400
[661]
1,600
[755]
1,600
[755]
1,475
[696]
1,475
[696]
1,600
[755]
1,625
[767]
1,600
[755]
1,875
[885]
ARI Htg. Performance (70°F [21.0°C] Indoor)
Outdoor Air
47°F DB/43°F WB
[8.5°C/6.0°C]
DOE High Temp.
BTU/H
[kW]
34,600
[10.1]
34,400
[10.1]
34,400
[10.1]
34,400
[10.1]
34,400
[10.1]
36,000
[10.5]
34,000
[10.0]
34,000
[10.0]
34,600
[10.1]
34,600
[10.1]
34,600
[10.1]
41,500
[12.2]
41,500
[12.2]
41,500
[12.2]
41,500
[12.2]
41,000
[12.0]
46,000
[13.5]
46,000
[13.5]
46,000
[13.5]
46,000
[13.5]
45,500
[13.3]
45,500
[13.3]
46,000
[13.5]
56,000
[16.4]
COP
3.44
3.46
3.46
3.46
3.46
3.50
3.58
3.58
3.44
3.44
3.44
3.60
3.56
3.56
3.60
3.74
3.54
3.54
3.58
3.58
3.72
3.74
3.54
3.64
Outdoor Air
17°F DB/15°F WB
[–8.5°C/–9.5°C]
DOE Low Temp.
BTU/H
[kW]
22,600
[6.6]
22,400
[6.6]
22,400
[6.6]
22,400
[6.6]
22,400
[6.6]
23,400
[6.9]
22,000
[6.4]
22,000
[6.4]
22,600
[6.6]
22,600
[6.6]
22,600
[6.6]
27,600
[8.1]
27,800
[8.1]
27,800
[8.1]
28,000
[8.2]
27,000
[7.9]
30,600
[9.0]
30,600
[9.0]
30,400
[8.9]
30,400
[8.9]
29,800
[8.7]
29,800
[8.7]
30,600
[9.0]
34,400
[10.1]
COP
2.40 8.50
2.40 8.50
2.40 8.50
2.40 8.50
2.40 8.50
2.36 8.20
2.46 9.00
2.46 9.00
2.40 8.50
2.40 8.50
2.40 8.50
2.54 8.50
2.54 8.50
2.54 8.50
2.66 9.00
2.66 9.00
2.60 8.50
2.60 7.70
2.58 8.50
2.58 8.50
2.68 9.00
2.68 9.00
2.60 8.50
2.50 8.50
Region
DOE
IV
HSPF