Rudd 024JEZ User Manual

PROJECT NAME ______________________________________________________________________________
LOCATION __________________________________________________________________________________
ARCHITECT__________________________________________________________________________________
ENGINEER __________________________________________________________________________________
CONTRACTOR ______________________________________________________________________________
SUBMITTED BY ______________________________ DATE ________________________________________
UNIT SUMMARY
SUBMIT TAL COVER SHEET
Quantity
Model No.
Total Cooling
Sensible Cooling
Air Ent. Evaporator
Air Lvg. Evaporator
Heating Input
Heating Output
CFM/ESP
EER/SEER
Electrical
Minimum Ampacity
Min.-Max. Breaker
Net Unit Weight
Accessory
Catalog Form Number
ACCESSORIES: NOTES:
PRINTED IN U.S.A. 3-02 DC FORM NO. X11-1123 REV. 1
Supersedes Form No. X11-1123 Rev. 0
SUBMITTAL SHEET FOR (-)ARL- JEZ 2 TO 5 TONS [7.03 TO 17.6 kW] , 16 SEER HIGH EFFICIENCY TWO-STAGE CONDENSING UNITS
FORM NO. X33-1247
JOB NAME LOCATION
CONTRACTOR ORDER NO.
ENGINEER
SUBMITTED FOR APPROVAL RECORD
DATE
UNIT MODEL NO.
COIL MODEL NO.
AIR HANDLER MODEL NO.
DIMENSIONS
[ ] Designates Metric Conversions
UNIT DATA
COOLING PERFORMANCE
EFFICIENCY ................................
_______
SEER
TOTAL CAPACITY*..................
_______
MBH [kW]
SENSIBLE CAPACITY*............
_______
MBH [kW]
OUTDOOR DESIGN TEMP. ....
_______
°F [°C] DB
TEMP. OF AIR ENTERING
EVAPORATOR COIL............
_______
°F [°C] DB
_______
°F [°C] WB
POWER INPUT REQUIREMENT ........
_______
kW
(*uses blower motor heat)
SUPPLY AIR BLOWER PERFORMANCE
TOTAL AIR SUPPLY ................
_______
CFM [L/s]
TOTAL RESISTANCE EXTERNAL
TO UNIT......................................
_______
IWG
BLOWER SPEED ..........................
_______
RPM
POWER OUTPUT REQUIREMENT ..
_______
BHP
MOTOR RATING ........................
_______
HP [W]
POWER INPUT REQUIREMENT ........
_______
kW
ELECTRICAL DATA
POWER SUPPLY ........................
____/____/____
TOTAL UNIT AMPACITY................
_______
AMPS
MINIMUM WIRE SIZE ....................
_______
AWG
MAXIMUM OVERCURRENT DEVICE
FUSES/HACR BREAKER ..........
_______
AMPS
CLEARANCES
ACCESS SIDE 24" [609.6 mm]
AIR INLETS 12" [304.8 mm]
ABOVE UNIT 60" [1524 mm]
Equipped with the Award Winning
Comfort Control System
• Increased Reliability • Fault Recall
• On-Board Diagnostics Active Protection
208-230V/1PH/60Hz
ACCESS PANE L
Model Number
036JEZ/048JEZ/060JEZ 33 [838] 443/8 [1127] 311/2 [800]
ALLOW 60 [1524 mm] CLEARANCE
L
ALLOW 24 [610 mm] ACCESS CLEARANCE
(-)ARL-
024JEZ 23 [584]
AIR DISCHARGE
W
ALTERNATE HIGH VOLTAGE CONNECTION (KNOCKOUT)
11
/32[34 mm]
1
Height “H”
(Inches) [mm]
earth friendly refrigerant
Length “L”
(Inches) [mm]
443/8 [1127] 311/2 [800]
H
AIR INLETS (LOUVERS) ALLOW 6 [152 mm] MIN. CLEARANCE 3 SIDES
Width “W”
(Inches) [mm]