Ruckus T610 User Manual

T610 Access Point
Quick Setup Guide
CAUTION! The minimum software revision for the T610
is ZoneDirector (ZD) 9.13.1 or later, or SmartZone (SZ) 3.4 or later, or standalone AP firmware 104.0 or later.
DO NOT CONNECT THE T610 TO A RUCKUS WIRELESS ZONEDIRECTOR RUNNING 9.13 OR EARLIER.
This Quick Setup Guide provides step-by-step instructions on how to field-install the Ruckus Wireless T610 access point (AP). For detailed information on planning the installation, performing a site survey, and operating the T610, refer to the ZoneFlex Outdoor Access Point User Guide, available at https://support.ruckuswireless.com
WARNING: Only trained and qualified personnel should be allowed to
install, replace, or service this equipment.
WARNING: Installation of this equipment must comply with local and
national electrical codes.
CAUTION: Make sure that you form a 80mm - 130mm (3”-5”) drip
loop in any cable that is attached to the AP or the building. This will prevent water from running along the cable and entering the AP or the building where the cable terminates.
CAUTION: Be sure that grounding is available and that it meets local
and national electrical codes. For additional lightning protection, use lightning rods and lightning arrestors.
CAUTION: Make sure that proper lightning surge protection
precautions are taken according to local electrical code.
WARNING: Ruckus Wireless strongly recommends that you wear eye
protection before mounting the T610.
.

THIS GUIDE IN OTHER LANGUAGES

请从以下网站获得该指南的简体中文版
https://support.ruckuswireless.com
Vous trouverez la version française de ce guide à l'adresse suivante
https://support.ruckuswireless.com
こ の ガ イ ド の⽇本語版 は https://support.ruckuswireless.com でご覧く ださい。
가이드의 한국어 버전은 사이트 (https://support.ruckuswireless.com) 에서 확인하시기 바랍니다 .
Veja a versão em português (Brasil) deste guia em
https://support.ruckuswireless.com.
Puede ver la versión en español (América Latina) de esta guía en
https://support.ruckuswireless.com.
.
.

BEFORE YOU BEGIN

Before deploying your Ruckus Wireless T610, verify that all items listed in Package Contents damaged or missing, notify your authorized Ruckus Wireless sales representative. Also, make sure that you have the required hardware and tools.

are included in the package. If any item is

REQUIRED HARDWARE AND TOOLS

Customer-supplied outdoor-rated three-wire (1-2mm2 or 14­18AWG) AC cable
1/2” (13mm) flat-blade screwdriver or equivalent
No. 2 Phillips screwdriver
Small flat-blade screwdriver
Torque wrench or torque screwdriver with sockets
Long-nose pliers
Electrical wire stripping and terminal crimping pliers
Pipe or pole --OR-- a sturdy flat surface
Electric drill with drill bits and customer-supplied wall anchors, flat washers, and hex nuts for flat-surface mount
Four factory-supplied 1/2” (12.7mm) wide stainless steel adjustable clamps, 2.5” (63.5mm) diameter, for main mounting bracket on smaller poles
•Ruler
PACKAGE CONTENTS
A complete T610 field installation package includes all of the items listed below (see Figure 1for illustrations):
T610 Access Point (A)
Two M25 data cable glands (B)
Ground wire with lug (C)
Service Level Agreement/Limited Warranty Statement
Declaration of Conformity
Regulatory Statement
Ruckus Wireless AP Getting Started Guide
This Quick Setup Guide
Figure 1: Package Contents
NOTE: The outdoor AP Mounting Bracket and security cable are
optional accessories that must be purchased separately.
Copyright © 2016 Ruckus Wireless, Inc. Published June 2016, Part Number 800-71230-001 Rev A
Page 1 of 4
STEP 1: CONNECTING AND SEALING THE RJ-45
Cable gland base
Clamping ring assembly
Rubber O-ring
Sealing nut
C
B
A
ABLES
C
Connect and seal the RJ-45 cable(s) using the M25 data cable gland as shown in Figure 3.
WARNING: Do not use any PoE injector not tested and approved by
Ruckus Wireless to power the T610 Access Point.
WARNING: Do NOT plug PoE in power into the non-PoE Port (see
Figure 2).
Figure 2: T610 bottom view
1 Feed the end of the cable through the sealing nut, rubber O-ring,
clamping ring assembly and cable gland base as shown in Figure
3.
Figure 3: RJ-45 cable and cable gland assembly
STEP 2: ATTACHING THE U-JOINT BRACKET TO THE
OUNTING BRACKET
M
NOTE: The following mounting instructions require purchase of
optional accessories that are not included in the standard T610 package. The outdoor AP Mounting Bracket and safety cable are optional accessories that must be purchased separately.
1 Position the U-joint bracket on the mounting bracket.
Figure 4: U-joint bracket attached horizontally to the mounting bracket
NOTE: Mount the U-joint bracket in any direction on the mounting
bracket, preferably to allow AP azimuth adjustments. Then the AP bracket allows AP elevation adjustments.
2 Use four 1/4-28 bolt and washer sets (A) to mount the U-joint
bracket (B) to the mounting bracket (C). Tighten the bolts to 9.5 N.m (7 ft-lbs).
3 Continue with
Flat Surface Metal Pole
Step 3a: Attaching the Mounting Bracket to a
or Step 3b: Attaching the Mounting Bracket to a
.
5 Using the mounting hardware instructions, tighten the hardware to
secure the mounting bracket.
6 Continue with
Joint Bracket
Step 4: Mounting the Linkage Bracket to the U-
.
STEP 3B: ATTACHING THE MOUNTING BRACKET TO A
ETAL POLE
M
1 Insert the open end of one steel clamp into the upper two slots on
the mounting bracket.
2 Take the other steel clamp and insert it into the lower two slots on
the mounting bracket.
NOTE: The clamps can be daisy-chained together to accommodate
larger poles.
3 Use the clamps to attach the mounting bracket to the pole.
Tighten the clamps to 3 N.m or 27 in-lbs, or per manufacturer’s specifications.
Figure 6: Attaching the mounting bracket to a vertical pole
2 Use a wide flat-blade screwdriver to remove the required (PoE IN)
blanking cap from the T610.
3 Connect the cable to the Ethernet port on the T610. 4 Tighten the cable gland base into the T610 chassis to 7 N.m or
62 in-lbs.
5 Wrap the clamping ring assembly around the rubber O-ring. Make
sure that the clamping ring assembly fully encloses the rubber O­ring.
6 Seat the clamping ring assembly and rubber O-ring in the cable
gland base.
7 Hand-tighten the sealing nut.
Copyright © 2016 Ruckus Wireless, Inc. Published June 2016, Part Number 800-71230-001 Rev A
STEP 3A: ATTACHING THE MOUNTING BRACKET TO A F
LAT SURFACE
1 Place the mounting bracket at the location on the flat surface
where you want to mount the AP. Use the holes on the mounting bracket as a template to mark the locations of the mounting holes.
Figure 5: Mounting bracket flat surface holes
2 Remove the mounting bracket from the flat surface. 3 Drill holes required for the mounting hardware.
NOTE: The hardware required for mounting to a wall are not included
in the mounting kit.
4 Attach the mounting bracket to the flat surface using the
mounting hardware.
4 Continue with
Joint Bracket
Step 4: Mounting the Linkage Bracket to the U-
.
STEP 4: MOUNTING THE LINKAGE BRACKET TO THE
OINT BRACKET
U-J
The linkage bracket attaches to the U-joint bracket using an M8 bolt and washer set. The linkage bracket is symmetrical, and either end can be attached to the U-joint bracket.
NOTE: Make sure that linkage bracket is installed with its serrated
external-tooth lock washer on the inside flanges. This ensures that the azimuth adjustment does not change.
1 Loosely assemble the linkage bracket (A), the U-joint bracket (C),
one
serrated external-tooth lock washer (B), and one M8 bolt
and washer set (D).
of the U-joint bracket
Page 2 of 4