Ruby Tech GS-1224L User Manual

GS-1224L User's Manual
Release 1.01
© 2007, RubyTech Corporation. All rights reserved. All brand and product names are trademarks or
The information in this document is subject to change without notice. Unless the explicit written permission of RubyTech Corporation, this document in whole or in part shall not be replicated or modified or amended or transmitted, in any from, or by any means manual, electric, electronic, electromagnetic, mechanical, optical or otherwise for any purpose.
DURATION OF HARDWARE WARRANTY
HARDWARE: In accordance with the provisions described under, RubyTech Corporation (hereinafter called “RubyTech”) warrants its hardware products (hereinafter referred to as "Product") specified herein to be for a period of twelve (12) months from the date of shipment.
Should a Product fail to perform during the effective warranty period as described above, RubyTech shall replace the defective Product or part, or delivering a functionally equivalent Product or part in receipt of customer’s request, provided that the customer complies with the return material authorization (RMA) procedures and returns all defective Product prior to installation of the replacements to RubyTech.
All defective Products must be returned to RubyTech with issuance of a Return Material Authorization number (RMA number) assigned to the reseller from whom the end customer originally purchased the Product. The reseller is responsible for ensuring the shipments are insured, with the transportation charges prepaid and the RMA number clearly marked on the outside of the package. RubyTech will not accept collect shipments or those returned without an RMA number.
RubyTech shall not be responsible for any software, firmware, information or memory data contained in, stored on or integrated with any Product returned to RubyTech pursuant to any warranty.
EXCLUSIONS. The warranty as mentioned above does not apply to the following conditions, in RubyTech’s judgment, it contains (1) customer does not comply with the manual instructions offered by RubyTech in installation, operation, repair or maintenance, (2) Product fails due to damage from unusual external or electrical stress, shipment, storage, accident, abuse or misuse, (3) Product is used in an extra hazardous environment or activities, (4) any serial number on the Product has been removed or defaced, (5) this warranty will be of no effect if the repair is via anyone other than RubyTech or the approved agents, or (6) In the event of any failures or delays by either party hereto in the performance of all or any part of this agreement due to acts of God, war, riot, insurrection, national emergency, strike, embargo, storm, earthquake, or other natural forces, or by the acts of anyone not a party to this agreement, or by the inability to secure materials or transportation, then the party so affected shall be executed from any further performance for a period of time after the occurrence as may reasonably be necessary to remedy the effects of that occurrence, but in no event more than sixty (60) days. If any of the stated events should occur, Party A shall promptly notify Party B in writing as soon as commercially practicable, but in no event more than twenty (20) business days and provide documentation evidencing such occurrence. In no event shall the maximum liability of RubyTech under this warranty exceed the purchase price of the Product covered by this warranty.
DISCLAIMER. EXCEPT AS SPECIFICALLY PROVIDED ABOVE AS REQUIRED “AS IS” AND THE WARRANTIES AND REMEDIES STATED ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHERS, ORAL OR WRITTEN, EXPRESS OR IMPLIED. ANY AND ALL OTHER WARRANTIES, INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OR THIRD PARTY RIGHTS ARE EXPRESSLY EXCLUDED.
RUBYTECH SOFTWARE LICENSE AGREEMENT
NOTICE: Please carefully read this Software License Agreement (hereinafter referred to as this “Agreement”) before copying or using the accompanying software or installing the hardware unit with pre-enabled software or firmware (each of which is referred to as “Software” in this Agreement). BY COPYING OR USING THE SOFTWARE, YOU ACCEPT ALL OF THE PROVISIONS AND CONDITIONS OF THIS AGREEMENT. THE PROVISIONS EXPRESSED IN THIS AGREEMENT ARE THE ONLY PROVISION UNDER WHICH RUBYTECH WILL PERMIT YOU TO USE THE SOFTWARE. If you do not accept these provisions and conditions, please immediately return the unused software, manual and the related product. Written approval is NOT a prerequisite to the validity or enforceability of this Agreement and no solicitation of any such written approval by or on behalf of RubyTech shall be deemed as an inference to the contrary.
LICENSE GRANT. The end user (hereinafter referred to as “Licensee”) of the Software is granted a personal, non-sublicensable, nonexclusive, nontransferable license by RubyTech Corporation (“RubyTech”): (1) To use the RubyTech’s software (“Software”) in object code form solely on a single central processing unit owned or leased by Licensee or otherwise embedded in the equipment offered by RubyTech. (2) To copy the Software only for backup purposes in support of authorized use of the Software. (3) To use and copy the documentation related to the Software solely in support of authorized use of the Software by Licensee. The License applies to the Software only except other RubyTech’s software or hardware products. Without the prior written consent of RubyTech, Licensee has no right to receive any source code or design documentation with respect to the Software.
RESTRICTIONS ON USE; RESERVATION OF RIGHTS. The Software and related documentation are protected under copyright laws. RubyTech and/or its licensors retain all title and ownership in both the Software and its related documentation, including any revisions made by RubyTech. The copyright notice must be reproduced and included with any copy of any portion of the Software or related documentation. Except as expressly authorized above, Licensee shall not copy or transfer the Software or related documentation, in whole or in part. Licensee also shall not modify, translate, decompile, disassemble, use for any competitive analysis, reverse compile or reverse assemble all or any portion of the Software, related documentation or any copy. The Software and related documentation embody RubyTech’s confidential and proprietary intellectual property. Licensee is not allowed to disclose the Software, or any information about the operation, design, performance or implementation of the Software and related documentation that is confidential to RubyTech to any third party. Software and related documentation may be delivered to you subject to export authorization required by governments of Taiwan and other countries. You agree that you will not export or re-export any Software or related documentation without the proper export licenses required by the governments of affected countries.
LIMITED SOFTWARE WARRANTY. RubyTech warrants that any media on which the Software is recorded will be free from defects in materials under normal use for a period of twelve (12) months from date of shipment. If a defect in any such media should occur during the effective warranty period, the media may be returned to RubyTech, then RubyTech will replace the media. RubyTech shall not be responsible for the replacement of media if the failure of the media results from accident, abuse or misapplication of the media.
EXCLUSIONS. The warranty as mentioned above does not apply to the Software, which (1) customer does not comply with the manual instructions offered by RubyTech in installation, operation, or maintenance, (2) Product fails due to damage from unusual external or electrical stress, shipment, storage, accident, abuse or misuse, (3) Product is used in an extra hazardous environment or activities, (4) any serial number on the Product has been removed or defaced, or (5) this warranty will be of no effect if the repair is via anyone other than RubyTech or the authorized agents. The maximum liability of RubyTech under this warranty is confined to the purchase price of the Product covered by this warranty.
ii
DISCLAIMER. EXCEPT AS PROVIDED ABOVE, THE SOFTWARE IS PROVIDED “AS IS ” AND RUBYTECH AND ITS LICENSORS MAKE NO WARRANTIES, EXPRESS OR IMPLIED, WITH REPSECT TO THE SOFTWARE AND DOCUMENTAITON. RUBYTECH AND ITS LICENSORS DISCLAIM ALL OTHER WARRANTIES, INCLUSIVE OF WITHOUT LIMITATION, IMPLIED WARRANTIES OR MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. FURTHER, RUBYTECH DOES NOT WARRANT, GUARANTEE, OR MAKE ANY REPRESENTATIONS REGARDING THE USE, OR THE RESULTS OF THE USE, OF THE SOFTWARE OR RELATED WRITTEN DOCUMENTAITON IN TERMS OF CORRECTNESS, ACCURACY, RELIABILITY, OR OTHERWISE.
CONSEQUENTIAL DAMAGES. IN NO EVENT SHALL RUBYTECH OR ITS AUTHORIZED RESELLER BE LIABLE TO LICENSEE OR ANY THIRD PARTY FOR (A) ANY MATTER BEYOND ITS REASONABLE CONTROL OR (B) ANY CONSEQUENTIAL, SPECIAL, INDIRECT OR INCIDENTAL DAMAGES ARISING OUT OF THIS LICENSE OR USE OF THE SOFTWARE PROVIDED BY RUBYTECH, EVEN IF RUBYTECH HAS BEEN NOTIFIED OF THE POSSIBILITY OF SUCH DAMAGES IN ADVANCE. IN NO EVENT SHALL THE LIABILITY OF RUBYTECH IN CONNECTION WITH THE SOFTWARE OR THIS AGREEMENT EXCEED THE PRICE PAID TO RUBYTECH FOR THE LICENSE.
TERM AND TERMINATION. The License is effective until terminated; however, all of the restrictions in regard to RubyTech’s copyright in the Software and related documentation will cease being effective at the date of expiration; Notwithstanding the termination or expiration of the term of this agreement, it is acknowledged and agreed that those obligations relating to use and disclosure of RubyTech’s confidential information shall survive. Licensee may terminate this License at any time by destroying the software together with all copies thereof. This License will be immediately terminated if Licensee fails to comply with any term and condition of the Agreement. Upon any termination of this License for any reason, Licensee shall discontinue to use the Software and shall destroy or return all copies of the Software and the related documentation.
GENERAL. This License shall be governed by and construed pursuant to the laws of Taiwan. If any portion hereof is held to be invalid or unenforceable, the remaining provisions of this License shall remain in full force and effect. Neither the License nor this Agreement is assignable or transferable by Licensee without RubyTech’s prior written consent; any attempt to do so shall be void. This License constitutes the entire License between the parties with respect to the use of the Software.
LICENSEE ACKNOWLEDGES THAT LICENSEE HAS READ THIS AGREEMENT, UNDERSTANDS IT, AND AGREES TO BE BOUND BY ITS TERMS AND CONDITIONS. LICENSEE FURTHER AGREES THAT THIS AGREEMENT IS THE ENTIRE AND EXCLUSIVE AGREEMENT BETWEEN RUBYTECH AND LICENSEE.
iii
Table of Contents
Caution ................................................................................................................................viii
Electronic Emission Notices ................................................................................................viii
1. Introduction .......................................................................................................................2
1-1. Overview of 24-Port GbE Web Smart Switch ................................................................2
1-2. Checklist.........................................................................................................................3
1-3. Features .........................................................................................................................3
1-4. View of 24-Port GbE Web Smart Switch........................................................................5
1-4-1. User Interfaces on the Front Panel (Button, LEDs and Plugs)...............................5
1-4-2. User Interfaces on the Rear Panel .........................................................................6
1-5. View of the Optional Modules ........................................................................................7
2. Installation .........................................................................................................................8
2-1. Starting 24-Port GbE Web Smart Switch Up..................................................................8
2-1-1. Hardware and Cable Installation ............................................................................8
2-1-2. Cabling Requirements ............................................................................................ 9
2-1-3. Configuring the Management Agent of 24-Port GbE Web Smart Switch .............14
2-1-4. IP Address Assignment......................................................................................... 16
2-2. Typical Applications......................................................................................................21
3. Basic Concept and Management....................................................................................23
3-1. What’s the Ethernet......................................................................................................23
3-2. Media Access Control (MAC).......................................................................................26
3-3. Flow Control .................................................................................................................32
3-4. How does a switch work?.............................................................................................35
3-5. Virtual LAN ...................................................................................................................39
3-6. Link Aggregation ..........................................................................................................45
4. Operation of Web-based Management .............................................................................47
4-1. Web Management Home Overview .............................................................................48
4-2. Configuration................................................................................................................50
4-2-1. System Configuration ...........................................................................................51
4-2-2. Ports Configuration...............................................................................................54
4-2-3. VLAN Mode Configuration....................................................................................55
4-2-4. VLAN Group Configuration...................................................................................57
4-2-5. Aggregation...........................................................................................................60
4-2-6. LACP ....................................................................................................................61
4-2-7. RSTP ....................................................................................................................62
4-2-8. 802.1X ..................................................................................................................64
4-2-9 IGMP Snooping .....................................................................................................71
4-2-10. Mirror Configuration............................................................................................72
4-2-11. QoS(Quality of Service) Configuration ...............................................................73
4-2-12 Filter.....................................................................................................................76
4-2-13 Rate Limit.............................................................................................................78
4-2-14 Storm Control.......................................................................................................79
4-2-15 SNMP ..................................................................................................................81
4-3. Monitoring ....................................................................................................................83
4-3-1. Statistics Overview ...............................................................................................83
4-3-2. Detailed Statistics .................................................................................................85
4-3-3. LACP Status .........................................................................................................88
4-3-4. RSTP Status .........................................................................................................89
iv
4-3-5. IGMP Status..........................................................................................................91
4-3-6. Ping Status............................................................................................................92
4-4. Maintenance.................................................................................................................94
4-4-1. Warm Restart........................................................................................................95
4-4-2. Factory Default .....................................................................................................96
4-4-3. Software Upgrade.................................................................................................97
4-4-4. Configuration File Transfer ...................................................................................98
4-4-5. Logout...................................................................................................................99
5. Maintenace .......................................................................................................................100
5-1. Resolving No Link Condition......................................................................................100
5-2. Q&A............................................................................................................................100
Appendix A Technical Specifications.....................................................................................101
Appendix B MIB Specifications..............................................................................................105
v
Revision History
Release Date Revision
1.00 02/10/2007 A1
1.01 03/13/2007 A1
vi
vii
Caution
Circuit devices are sensitive to static electricity, which can damage their delicate electronics. Dry weather conditions or walking across a carpeted floor may cause you to acquire a static electrical charge.
To protect your device, always:
Touch the metal chassis of your computer to ground the static electrical charge before
you pick up the circuit device.
Pick up the device by holding it on the left and right edges only.
Electronic Emission Notices
Federal Communications Commission (FCC) Statement
This equipment has been tested and found to comply with the limits for a class A computing device pursuant to Subpart J of part 15 of FCC Rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment.
European Community (CE) Electromagnetic Compatibility Directive
This equipment has been tested and found to comply with the protection requirements of European Emission Standard EN55022/EN60555-2 and the Generic European Immunity Standard EN50082-1.
EMC:
EN55022(1988)/CISPR-22(1985) class A EN60555-2(1995) class A EN60555-3 IEC1000-4-2(1995) 4K V CD, 8KV, AD IEC1000-4-3(1995) 3V/m IEC1000-4-4(1995) 1KV – (power line), 0.5KV – (signal line)
viii
About this user’s manual
In this user’s manual, it will not only tell you how to install and connect your network system but configure and monitor the 24-Port GbE Web Smart Switch through the Ethernet ports step-by-step. Many explanation in detail of hardware and software functions are shown as well as the examples of the operation for web­based interface.
Overview of this user’s manual
Chapter 1 “Introduction” describes the features of 24 Gigabit Web Smart Switch
Chapter 2 “Installation” Chapter 3 “Operating Concept and Management” Chapter 4 “Operation of Web-based Management” Chapter 5 “Maintenance”
Publication date: March, 2007
Revision A1
1
User Manual
1. Introduction
1-1. Overview of 24-Port GbE Web Smart Switch
24-port Gigabit Web Smart Switch is a standard switch that meets all IEEE
802.3/u/x/z Gigabit, Fast Ethernet specifications. The switch included 20-Port 10/100/1000Mbps TP and 4-Port Gigabit TP/SFP Fiber Web Smart management Ethernet Switch. The switch can be managed through Ethernet port using Web­based management unit, associated with web-based management, the network administrator can logon the switch to monitor, configure and control each port’s activity. In addition, the switch implements the QoS (Quality of Service), VLAN, and
Trunking. It is suitable for office application.
In this switch, Port 21, 22, 23, 24 includes two types of media --- TP and SFP Fiber (LC, BiDi-SC…); this port supports 10/100/1000Mbps TP or 1000Mbps SFP Fiber with auto-detected function. 1000Mbps SFP Fiber transceiver is used for high­speed connection expansion.
1000Mbps LC, Multi-Mode, SFP Fiber transceiver 1000Mbps LC, 10km, SFP Fiber transceiver 1000Mbps LC, 30km, SFP Fiber transceiver 1000Mbps LC, 50km, SFP Fiber transceiver 1000Mbps BiDi-SC, 20km, 1550nm SFP Fiber WDM transceiver
1000Mbps BiDi-SC, 20km, 1310nm SFP Fiber WDM transceiver
10/100/1000Mbps TP is a standard Ethernet port that meets all IEEE
802.3/u/x/z Gigabit, Fast Ethernet specifications. 1000Mbps SFP Fiber transceiver is a Gigabit Ethernet port that fully complies with all IEEE 802.3z and 1000Base­SX/LX standards.
1000Mbps Single Fiber WDM (BiDi) transceiver is designed with an optic Wavelength Division Multiplexing (WDM) technology that transports bi-directional full duplex signal over a single fiber simultaneously.
Key Features in the Device
QoS:
The
switch offers powerful QoS function. This function supports 802.1p
VLAN tag priority and DSCP on Layer 3 of network framework.
VLAN:
Supports Port-based VLAN, IEEE802.1Q Tag VLAN. And supports 24 active VLANs and VLAN ID 1~4094.
Port Trunking:
Allows one or more links to be aggregated together to form a Link Aggregation Group by the static setting.
Publication date: March, 2007
Revision A1
2
User Manual
1-2. Checklist
Before you start installing the switch, verify that the package contains the following:
A 24-Port GbE Web Smart Switch Modules (optional) Mounting Accessory (for 19” Rack Shelf) This User's Manual in CD-ROM AC Power Cord
Please notify your sales representative immediately if any of the aforementioned items is missing or damaged.
1-3. Features
The 24-Port GbE Web Smart Switch, a standalone off-the-shelf switch, provides the comprehensive features listed below for users to perform system network administration and efficiently and securely serve your network.
Hardware
20 10/100/1000Mbps Auto-negotiation Gigabit Ethernet TP ports
4 10/100/1000Mbps TP or 1000Mbps SFP Fiber dual media auto sense
400KB on-chip frame buffer
Jumbo frame support
Programmable classifier for QoS (Layer 2/Layer 3)
8K MAC address and support VLAN ID (1~4094)
Per-port shaping, policing, and Broadcast Storm Control
IEEE802.1Q-in-Q nested VLAN support
Full-duplex flow control (IEEE802.3x) and half-duplex backpressure
Extensive front-panel diagnostic LEDs; System: Power, TP Port1-24: LINK/ACT, 10/100/1000Mbps, SFP Port 21, 22, 23,24: SFP(LINK/ACT)
Management
Supports concisely the status of port and easily port configuration
Supports per port traffic monitoring counters
Supports a snapshot of the system Information when you login
Supports port mirror function
Supports the static trunk function
Publication date: March, 2007
Revision A1
3
User Manual
Supports 802.1Q VLAN
Supports user management and limits one user to login
Maximal packet length can be up to 9600 bytes for jumbo frame application
Supports Broadcasting Suppression to avoid network suspended or crashed
Supports to send the trap event while monitored events happened
Supports default configuration which can be restored to overwrite the current
configuration which is working on via Web UI and Reset button of the switch
Supports on-line plug/unplug SFP modules
Supports Quality of Service (QoS) for real time applications based on the information taken from Layer 2 to Layer 3.
Built-in web-based management instead of using CLI interface, providing a more convenient GUI for the user
Publication date: March, 2007
Revision A1
4
User Manual
1-4. View of 24-Port GbE Web Smart Switch
Fig. 1-1 Full View of 24-PORT GBE WEB SMART SWITCH
1-4-1. User Interfaces on the Front Panel (Button, LEDs and Plugs)
There are 24 TP Gigabit Ethernet ports and 4 SFP fiber ports for optional removable modules on the front panel of the switch. LED display area, locating on the left side of the panel, contains a Power LED, which indicates the power status and 24 ports working status of the switch.
TP Port Status Indication LEDs
Power Indication LED
Fiber Port Status Indication LEDs
Fig. 1-2 Front View of 24-PORT GBE WEB SMART
Gigabit Ethernet Port
RESET Button:
RESET button is used to restore the system default setting.
SFP Fiber Port
Publication date: March, 2007
Revision A1
5
User Manual
A
LED Indicators
LED Color Function
System LED
POWER Green
10/100/1000Ethernet TP Port 1 to 24 LED
LINK/ACT Green
10/100/1000Mbps
1000SX/LX Gigabit Fiber Port 21, 22, 23, 24 LED
SFP(LINK/ACT) Green
Green/ Amber
1-4-2. User Interfaces on the Rear Panel
Lit when +3.3V power is coming up
Lit when connection with remote device is good Blinks when any traffic is present
Lit Green when TP link on 1000Mbps speed Lit Amber when TP link on 100Mbps speed Off when 10Mbps or no link occur Blinks when any traffic is present
Lit when SFP connection with remote device is good Blinks when any traffic is present
Table1-1
C Line 100-240V 50/60 Hz
Fig. 1-3 Rear View of 24-PORT GBE WEB SMART SWITCH
Publication date: March, 2007
Revision A1
6
User Manual
1-5. View of the Optional Modules
In the switch, Port 21~24 includes two types of media --- TP and SFP Fiber (LC, BiDi-SC…); this port supports 10/100/1000Mbps TP or 1000Mbps SFP Fiber with auto-detected function. 1000Mbps SFP Fiber transceiver is used for high­speed connection expansion; nine optional SFP types provided for the switch are listed below:
1000Mbps LC, MM, SFP Fiber transceiver (SFP.0LC.202)
1000Mbps LC, SM 10km, SFP Fiber transceiver (SFP.0LC.212.10)
1000Mbps LC, SM 30km, SFP Fiber transceiver (SFP.0LC.212.30)
1000Mbps LC, SM 50km, SFP Fiber transceiver (SFP.0LC.212.50)
1000Mbps LC, SM 70km, SFP Fiber transceiver (SFP.0LC.212.70)
1000Mbps LC, SM 110km, SFP Fiber transceiver (SFP.0LC.212.B0)
1000Mbps BiDi SC, type 1, SM 20km, SFP Fiber WDM transceiver
(SFP.0BS.621.201)
1000Mbps BiDi SC, type 2, SM 20km, SFP Fiber WDM transceiver
(SFP.0BS.621.202)
1000Mbps LC, SM 10km, SFP Fiber transceiver with DDM
(SFP.DLC.212.10)
Fig. 1-4 Front View of 1000Base-SX/LX LC, SFP Fiber Transceiver
Fig. 1-5 Front View of 1000Base-LX BiDi SC SFP Fiber Transceiver
Publication date: March, 2007
Revision A1
7
User Manual
r
2. Installation
2-1. Starting 24-Port GbE Web Smart Switch Up
This section will give users a quick start for:
- Hardware and Cable Installation
- Management Station Installation
- Software booting and configuration
2-1-1. Hardware and Cable Installation
At the beginning, please do first:
Wear a grounding device to avoid the damage from electrostatic discharge
Be sure that power switch is OFF before you insert the power cord to power
source
Installing Optional SFP Fiber Transceivers to the 24-Port GbE Web Smart
Switch
Note: If you have no modules, please skip this section.
Connecting the SFP Module to the Chassis:
The optional SFP modules are hot swappable, so you can plug or unplug it before or after powering on.
1. Verify that the SFP module is the right model and conforms to the chassis
2. Slide the module along the slot. Also be sure that the module is properly
seated against the slot socket/connector
3. Install the media cable for network connection
4. Repeat the above steps, as needed, for each module to be installed into
slot(s)
5. Have the power ON after the above procedures are done
Publication date: March, 2007
Revision A1
Fig. 2-1 Installation of Optional SFP Fiber Transceive
8
User Manual
TP Port and Cable Installation
In the switch, TP port supports MDI/MDI-X auto-crossover, so both types of
cable, straight-through (Cable pin-outs for RJ-45 jack 1, 2, 3, 6 to 1, 2, 3, 6 in 10/100M TP; 1, 2, 3, 4, 5, 6, 7, 8 to 1, 2, 3, 4, 5, 6, 7, 8 in Gigabit TP) and crossed-over (Cable pin-outs for RJ-45 jack 1, 2, 3, 6 to 3, 6, 1, 2) can be used. It means you do not have to tell from them, just plug it.
Use Cat. 5 grade RJ-45 TP cable to connect to a TP port of the switch and the
other end is connected to a network-aware device such as a workstation or a server.
Repeat the above steps, as needed, for each RJ-45 port to be connected to a
Gigabit 10/100/1000 TP device.
Now, you can start having the switch in operation.
Power On
The switch supports 100-240 VAC, 50-60 Hz power supply. The power supply will automatically convert the local AC power source to DC power. It does not matter whether any connection plugged into the switch or not when power on, even modules as well. After the power is on, all LED indicators will light up and then all off except the power LED still keeps on. This represents a reset of the system.
Firmware Loading
After resetting, the bootloader will load the firmware into the memory. It will take about 30 seconds, after that, the switch will flash all the LED once and automatically performs self-test and is in ready state.
2-1-2. Cabling Requirements
To help ensure a successful installation and keep the network performance good, please take a care on the cabling requirement. Cables with worse specification will render the LAN to work poorly.
Publication date: March, 2007
Revision A1
9
User Manual
2-1-2-1. Cabling Requirements for TP Ports
For Fast Ethernet TP network connection
The grade of the cable must be Cat. 5 or Cat. 5e with a maximum length of
100 meters.
Gigabit Ethernet TP network connection
The grade of the cable must be Cat. 5 or Cat. 5e with a maximum length of
100 meters. Cat. 5e is recommended.
2-1-2-2. Cabling Requirements for 1000SX/LX SFP Module
It is more complex and comprehensive contrast to TP cabling in the fiber media. Basically, there are two categories of fiber, multi mode (MM) and single mode (SM). The later is categorized into several classes by the distance it supports. They are SX, LX, LHX, XD, and ZX. From the viewpoint of connector type, there mainly are LC and BIDI SC.
Gigabit Fiber with multi-mode LC SFP module
Gigabit Fiber with single-mode LC SFP module
Gigabit Fiber with BiDi SC 1310nm SFP module
Gigabit Fiber with BiDi SC 1550nm SFP module
The following table lists the types of fiber that we support and those else not listed here are available upon request.
Multi-mode Fiber Cable and Modal Bandwidth
IEEE 802.3z Gigabit Ethernet
1000SX 850nm
1000Base­LX/LHX/XD/ZX
1000Base-LX Single Fiber (BIDI SC)
Table2-1
Multi-mode 62.5/125μm Multi-mode 50/125μm
Modal
Bandwidth
160MHz-Km 220m 400MHz-Km 500m
200MHz-Km 275m 500MHz-Km 550m
Single-mode Fiber 9/125μm
Single-mode transceiver 1310nm 10Km
Single-mode transceiver 1550nm 30, 50Km
Single-Mode
Single-Mode
Distance
*20Km
*20Km
Modal Bandwidth
TX(Transmit) 1310nm
RX(Receive) 1550nm
TX(Transmit) 1550nm
RX(Receive) 1310nm
Distance
Publication date: March, 2007
Revision A1
10
User Manual
2-1-2-3. Switch Cascading in Topology
Takes the Delay Time into Accou nt
Theoretically, the switch partitions the collision domain for each port in switch cascading that you may up-link the switches unlimitedly. In practice, the network extension (cascading levels & overall diameter) must follow the constraint of the IEEE 802.3/802.3u/802.3z and other 802.1 series protocol specifications, in which the limitations are the timing requirement from physical signals defined by 802.3 series specification of Media Access Control (MAC) and PHY, and timer from some OSI layer 2 protocols such as 802.1d, 802.1q, LACP and so on.
The fiber, TP cables and devices’ bit-time delay (round trip) are as follows:
1000Base-X TP, Fiber 100Base-TX TP 100Base-FX Fiber
Round trip Delay: 4096 Round trip Delay: 512
Cat. 5 TP Wire: 11.12/m Cat. 5 TP Wire: 1.12/m Fiber Cable: 1.0/m
Fiber Cable : 10.10/m TP to fiber Converter: 56
Bit Time unit : 1ns (1sec./1000 Mega bit)
Bit Time unit: 0.01μs (1sec./100 Mega bit)
Table 2-2
Sum up all elements’ bit-time delay and the overall bit-time delay of wires/devices must be within Round Trip Delay (bit times) in a half-duplex network segment (collision domain). For full-duplex operation, this will not be applied. You may use the TP-Fiber module to extend the TP node distance over fiber optic and provide the long haul connection.
Typical Network Topology in Deployment
A hierarchical network with minimum levels of switch may reduce the timing delay between server and client station. Basically, with this approach, it will minimize the number of switches in any one path; will lower the possibility of network loop and will improve network efficiency. If more than two switches are connected in the same network, select one switch as Level 1 switch and connect all other switches to it at Level 2. Server/Host is recommended to connect to the Level 1 switch. This is general if no VLAN or other special requirements are applied.
11
Publication date: March, 2007
Revision A1
User Manual
Case1: All switch ports are in the same local area network. Every port can access
each other (See Fig. 2-2).
Fig. 2-2 No VLAN Configuration Diagram
If VLAN is enabled and configured, each node in the network that can communicate each other directly is bounded in the same VLAN area.
Here VLAN area is defined by what VLAN you are using. The switch supports both port-based VLAN and tag-based VLAN. They are different in practical deployment, especially in physical location. The following diagram shows how it works and what the difference they are.
Case2a: Port-based VLAN (See Fig.2-3).
1. The same VLAN members could not be in different switches.
2. Every VLAN members could not access VLAN members each other.
3. The switch manager has to assign different names for each VLAN groups at one switch.
Publication date: March, 2007
Revision A1
Fig. 2-3 Port-based VLAN Diagram
12
Case 2b: Port-based VLAN (See Fig.2-4).
User Manual
Fig. 2-4 Port-based VLAN Diagram
1. VLAN1 members could not access VLAN2, VLAN3 and VLAN4 members.
2. VLAN2 members could not access VLAN1 and VLAN3 members, but they could access VLAN4 members.
3. VLAN3 members could not access VLAN1, VLAN2 and VLAN4.
4. VLAN4 members could not access VLAN1 and VLAN3 members, but they could access VLAN2 members.
Case3a: The same VLAN members can be at different switches with the same VID (See Fig. 2-5).
Fig. 2-5 Attribute-based VLAN Diagram
13
Publication date: March, 2007
Revision A1
User Manual
2-1-3. Configuring the Management Agent of 24-Port GbE Web Smart
Switch
In the way of web, user is allowed to startup the switch management function. Users can use any one of them to monitor and configure the switch. You can touch them through the following procedures.
Section 2-1-3-1: Configuring Management Agent of 24-Port GbE Web Smart Switch
through Ethernet Port
Publication date: March, 2007
Revision A1
14
User Manual
A
2-1-3-1. Configuring Management Agent of 24-Port GbE Web Smart Switch
through Ethernet Port
There are two ways to configure and monitor the switch through the switch’s Ethernet port. They are Web browser and SNMP manager. The user interface for the last one is RubyView dependent and does not cover here. We just introduce the first type of management interface. Web-based UI for the switch is an interface in a highly friendly way.
Fig. 2-6
Managing 24-Port GbE Web Smart Switch through Ethernet Port
Before you communicate with the switch, you have to finish first the configuration of the IP address or to know the IP address of the switch. Then, follow the procedures listed below.
1. Set up a physical path between the configured the switch and a PC by a qualified UTP Cat. 5 cable with RJ-45 connector.
24-PORT GBE WEB SMART SWITCH Default IP Setting: IP = 192.168.1.1 Subnet Mask = 255.255.255.0 Default Gateway = 192.168.1.254
ssign a reasonable IP address,
For example:
Ethernet LAN
IP = 192.168.1.100 Subnet Mask = 255.255.255.0 Default Gateway = 192.168.1.254
Note: If PC directly connects to the switch, you have to setup the
same subnet mask between them. But, subnet mask may be different for the PC in the remote site. Please refer to Fig. 2-6 about the 24-Port GbE Web Smart Switch default IP address information.
2. Run web browser and follow the menu. Please refer to Chapter 4.
Publication date: March, 2007
Revision A1
15
User Manual
Fig. 2-7 the Login Screen for Web
2-1-4. IP Address Assignment
For IP address configuration, there are three parameters needed to be filled
in. They are IP address, Subnet Mask, Default Gateway and DNS.
IP address:
The address of the network device in the network is used for internetworking communication. Its address structure looks is shown in the Fig. 2-8. It is “classful” because it is split into predefined address classes or categories.
Each class has its own network range between the network identifier and host identifier in the 32 bits address. Each IP address comprises two parts: network identifier (address) and host identifier (address). The former indicates the network where the addressed host resides, and the latter indicates the individual host in the network which the address of host refers to. And the host identifier must be unique in the same LAN. Here the term of IP address we used is version 4, known as IPv4.
32 bits
Network identifier Host identifier
Fig. 2-8 IP address structure
Publication date: March, 2007
Revision A1
16
User Manual
N
With the classful addressing, it divides IP address into three classes, class A, class B and class C. The rest of IP addresses are for multicast and broadcast. The bit length of the network prefix is the same as that of the subnet mask and is denoted as IP address/X, for example, 192.168.1.0/24. Each class has its address range described below.
Class A:
Address is less than 126.255.255.255. There are a total of 126 networks can be defined because the address 0.0.0.0 is reserved for default route and
127.0.0.0/8 is reserved for loopback function.
Bit # 0 1 7 8 31
0
etwork address Host address
Class B:
IP address range between 128.0.0.0 and 191.255.255.255. Each class B network has a 16-bit network prefix followed 16-bit host address. There are 16,384 (2^14)/16 networks able to be defined with a maximum of 65534 (2^16 –2) hosts per network.
Bit # 01 2 15 16 31
10
Network address Host address
Class C:
IP address range between 192.0.0.0 and 223.255.255.255. Each class C network has a 24-bit network prefix followed 8-bit host address. There are 2,097,152 (2^21)/24 networks able to be defined with a maximum of 254 (2^8 –2) hosts per network.
Bit # 0 1 2 3 23 24 31
110
Network address Host address
Publication date: March, 2007
Revision A1
17
User Manual
t
N
Class D and E:
Class D is a class with first 4 MSB (Most significance bit) set to 1-1-1-0 and is used for IP Multicast. See also RFC 1112. Class E is a class with first 4 MSB set to 1-1-1-1 and is used for IP broadcast.
According to IANA (Internet Assigned Numbers Authority), there are three specific IP address blocks reserved and able to be used for extending internal network. We call it Private IP address and list below:
Class A 10.0.0.0 --- 10.255.255.255 Class B 172.16.0.0 --- 172.31.255.255 Class C 192.168.0.0 --- 192.168.255.255
Please refer to RFC 1597 and RFC 1466 for more information.
Subnet mask:
It means the sub-division of a class-based network or a CIDR block. The subnet is used to determine how to split an IP address to the network prefix and the host address in bitwise basis. It is designed to utilize IP address more efficiently and ease to manage IP network.
For a class B network, 128.1.2.3, it may have a subnet mask 255.255.0.0 in default, in which the first two bytes is with all 1s. This means more than 60 thousands of nodes in flat IP address will be at the same network. It’s too large to manage practically. Now if we divide it into smaller network by extending network prefix from 16 bits to, say 24 bits, that’s using its third byte to subnet this class B network. Now it has a subnet mask 255.255.255.0, in which each bit of the first three bytes is 1. It’s now clear that the first two bytes is used to identify the class B network, the third byte is used to identify the subnet within this class B network and, of course, the last byte is the host number.
Not all IP address is available in the sub-netted network. Two special addresses are reserved. They are the addresses with all zero’s and all one’s host number. For example, an IP address 128.1.2.128, what IP address reserved will be looked like? All 0s mean the network itself, and all 1s mean IP broadcast.
10000000.00000001.00000010.1 0000000
Publication date: March, 2007
Revision A1
etwork
25 bits
All 0s = 128.1.2.128
All 1s= 128.1.2.255
18
Subne
1 0000000 1 1111111
User Manual
In this diagram, you can see the subnet mask with 25-bit long,
255.255.255.128, contains 126 members in the sub-netted network. Another is that the length of network prefix equals the number of the bit with 1s in that subnet mask. With this, you can easily count the number of IP addresses matched. The following table shows the result.
Prefix Length No. of IP matched No. of Addressable IP
/32
1 -
/31
/30
/29
/28
/27
/26
/25
/24
/23
/22
/21
/20
/19
/18
/17
2 ­4 2
8 6 16 14 32 30 64 62
128 126 256 254
512 510 1024 1022 2048 2046 4096 4094 8192 8190
16384 16382 32768 32766
/16
65536 65534
Table 2-3
According to the scheme above, a subnet mask 255.255.255.0 will partition a network with the class C. It means there will have a maximum of 254 effective nodes existed in this sub-netted network and is considered a physical network in an autonomous network. So it owns a network IP address which may looks like
168.1.2.0.
With the subnet mask, a bigger network can be cut into small pieces of network. If we want to have more than two independent networks in a worknet, a partition to the network must be performed. In this case, subnet mask must be applied.
Publication date: March, 2007
Revision A1
19
User Manual
For different network applications, the subnet mask may look like
255.255.255.240. This means it is a small network accommodating a maximum of 15 nodes in the network.
Default gateway:
For the routed packet, if the destination is not in the routing table, all the traffic is put into the device with the designated IP address, known as default router. Basically, it is a routing policy.
For assigning an IP address to the switch, you just have to check what the IP address of the network will be connected with the switch. Use the same network address and append your host address to it.
Fig. 2-9
First, IP Address: as shown in the Fig. 2-9, enter “192.168.1.1”, for instance. For sure, an IP address such as 192.168.1.x must be set on your PC.
Second, Subnet Mask: as shown in the Fig. 2-9, enter “255.255.255.0”. Any subnet mask such as 255.255.255.x is allowable in this case.
Publication date: March, 2007
Revision A1
20
Loading...