Ruby RC-1001 User Manual

Page 1
Page 2
Publication date: March, 2011
Revision A2
i
User's Manual
Web Smart 10/100Base-TX to 100Base-FX
Media Converter
Release 1.04
Page 3
Publication date: March, 2011
Revision A2
ii
Table of Contents
C
AUTION........................................................................................................................................... IV
ELECTRONIC EMISSION NOTICES..................................................................................................... IV
1. INTRODUCTION ............................................................................................................ 1
1-1. OVERVIEW .................................................................................................................................. 1
1-2. FEATURES ................................................................................................................................... 1
1-3. CHECKLIST ................................................................................................................................. 2
1-4. VIEW OF THE CONVERTER .......................................................................................................... 3
2. INSTALLATION .............................................................................................................. 4
2-1. CABLE AND HARDWARE INSTALLATION ..................................................................................... 4
3. OPERATION OF WEB-BASED MANAGEMENT ...................................................... 5
3-1. WEB MANAGEMENT HOME OVERVIEW ..................................................................................... 6
3-2. THE FUNCTION TREE IN WEB MANAGEMENT ............................................................................ 8
3-3. LOCAL SETTING ......................................................................................................................... 9
3-3-1. IP Configuration .............................................................................................................. 9
3-3-2. Password Setting ............................................................................................................ 11
3-3-3. Converter Configuration ............................................................................................... 12
3-3-4. Port Configuration......................................................................................................... 14
3-3-5. MIB Counter .................................................................................................................. 16
3-3-6. VLAN .............................................................................................................................. 17
3-3-6-1. V LAN Group ........................................................................................................................... 17
3-3-6-2. V LA N P er Port Setting ........................................................................................................... 19
3-3-7. Q-in-Q ............................................................................................................................. 21
3-4. REMOTE SETTING .................................................................................................................... 23
3-4-1. TS-1000 Functions ......................................................................................................... 23
3-4-1-1. TS -1000 Setting ....................................................................................................................... 23
3-4-1-2. Loopback Test ......................................................................................................................... 25
3-4-1-3. Remote Device Reset ............................................................................................................... 26
3-4-1-4. Remote Port Information ....................................................................................................... 27
3-4-1-5. Remote Port Setting ................................................................................................................ 27
3-4-2. 802.3ah Function ............................................................................................................ 28
3-4-2-1. 802.3ah Con figuration ............................................................................................................ 28
3-4-2-2. Loopback Test ......................................................................................................................... 29
3-4-2-3. 802.3ah Status .......................................................................................................................... 30
3-5. TOOLS ....................................................................................................................................... 31
3-5-1. System Reboot ................................................................................................................ 31
3-5-2. Save and Restore ............................................................................................................ 32
3-5-3. Firmware Upgrade ........................................................................................................ 33
3-5-4. Logout ............................................................................................................................. 33
4. MAINTENANCE .............................................................................................................34
4-1. RESOLVING NO LINK CONDITIONS ........................................................................................... 34
4-2. Q&A ........................................................................................................................................ 34
APPENDIX A TECHNICAL SPECIFICATIONS ...........................................................35
Page 4
Publication date: March, 2011
Revision A2
iii
Revision History
Release Date Revision
0.96 12/04/2009
A
1
1.01 10/7/2010
A
1
1.02 10/29/2010
A
1
1.04 03/03/2011
A
2
Page 5
Publication date: March, 2011
Revision A2
iv
Caution
Circuit devices are sensitive to static electricity, which can damage their delicate electronics. Dr y weather conditions or walking acr oss a carpeted floor may cause you to acquire a static electrical charge.
To protect your device, always:
Touch the metal chassis of your computer to ground the static electrical
charge before you pick up the circuit device.
Pick up the device by holding it on the left and right edges only.
Electronic Emission Notices
Federal Communications Commission (FCC) Statement
This equipment has been tested and found to comply with the FCC Part 15, Subpart B, Class A. CISPR 22:A1:2000+A2:2002;ICES-003:2004, Class A
European Community (CE) Electromagnetic Compatibility Directive
This equipment has been tested and found to comply with the protection requirements of European Emission Standard EN55022 and EN55024.
EMI
EN55022:2006 Class A EN61000-3-2:2006 EN61000-3-3:1995+A1:2001+A2/2005+A1/2001+A2/2005
EMS
EN55024/1998+A1:2001+A2:2003
IEC61000-4-2:2001 IEC61000-4-3:2002+A1:2002 IEC61000-4-4:1995+A1:2000+A2:2001 IEC61000-4-5:2001 IEC61000-4-6:2003 IEC61000-4-8:2001 IEC61000-4-11:2001
Page 6
Publication date: March, 2011
Revision A2
v
About this user’s manual
In this user’s manual, it wi ll not o nly tell you how to install and conn ec t your network system but configur e and m onitor the W eb Smart MEDIA CONVERTER through the built-in web by E ther net po rts step- by-ste p. Man y expl anations in detail of hard wa re and software functions ar e sho wn as we ll as the ex am ples of the oper atio n for web­based interface.
Overview of this user’s manual
Chapter 1 “Introduction” describes the features of Web Smart MEDIA
CONVERTER
Chapter 2 “Installation”  Chapter 3 “Operation of Web-based Management”  Chapter 4 “Maintenance”  Appendix A
Page 7
Publication date: March, 2011
Revision A2
1
1. Introduction
1-1. Overview
The Converter is des igned to m ake conver sion betwee n 10/100Base- TX and 100Base-FX Fast Ethernet. With Web-based management, the network administrator can logon the converter to monitor, configure and control the activity of each port. In addition, the converter implements bandwidth rating management capability via the intel ligent software. T he over all net work managem ent is enhance d, and the network efficiency is also improved to accommodate and deliver high bandwidth applications.
1-2. Features
The Web Smart MEDIA CONVERTER provides the following features for users to perform system network administration.
Management
• Supports Web UI for management
• Supports OAM for remote management via TS-1000
• Supports OAM for remote management via IEEE802.3ah
• Supports Ingress/Egress Rate Limitation
• Supports Link Loss Carry Forward Function
• Supports per Port MIB Counters
• Supports IEEE802.1Q VLAN
• Supports Q-in-Q (Double-Tag) VLAN
• Supports one 10/100Base-TX Fast Ethernet UTP port and one 100Base-FX FE Fiber port
• Supports 802.3x flow control for full-duplex ports and backpressure for half-duplex ports
• Supports comprehensive types of fiber with different distances and connections, including SC/Bidi/LC and so on
• Supports auto mode on the TP port
• Supports jumbo frame 9KB
• RoHS Compliance
• On-board firmware can be updated via HTTP web function.
• The converter allows administrator to reboot system from management station.
• Dying Gasp function can send out a signal when DC power down is detected.
Page 8
Publication date: March, 2011
Revision A2
2
1-3. Checklist
Before you start installing the converter, please verify that the package contains the
following:
Web Smart Media Converter AC-DC Power adapter This User's Manual(CD)
Please notify your sales representative immediately if any of the aforementioned
items is missing or damaged.
Model
Model Description
RC-1001 Web Smart 10/100Base-T to 100Base-FX Media Converter RC-1001A Web Smart 10/100Base-T to SFP Media Converter
Page 9
Publication date: March, 2011
Revision A2
3
1-4. View of the Converter
RC-1001 RC-1001A
Fig. 1-1 WEB SMART MEDIA CONVERTER
RC-1001 RC-1001A
Fig. 1-2 Front View of the WEB SMART MEDIA CONVERTER
LED Indicators Description
LED Color Function
POWER Green Lit when +5V power is coming up FX LINK/ACT Green
Lit when fiber connection is go od Blinks when any traffic is present
TP LINK/ACT Green
Lit when TP connection is good Blinks when any traffic is present
TP 10/100 Amber
Lit when 100Base-TX is active Off when 10Base-T is active
Table 1-1
Fig. 1-3 Rear View of the WEB SMART MEDIA CONVERTER
Reset button:
Press this button over 5 seconds then (1) Restore to default (2) Reboot
Page 10
Publication date: March, 2011
Revision A2
4
2. Installation
2-1. Cable and Hardware Installation
Wear a grounding device for electrostatic discharge
Verify that the AC-DC adapter conforms to your country AC power requirement
and then insert the power plug
TP Cable
Use Cat. 5 TP cable to connect server/host or work s tation to TP port of the
converter
TP port supports MDI/MDI-X auto-crossover, use:
straight-through cable (Cable pin-outs for RJ-45 jack 1, 2, 3, 6 to 1, 2, 3, 6) to cascade or up-link the converter to an upper layer L2/L3 switch or server/host/work station
TP Cable Limitations: Cat. 5 and up to 100m
Fiber Cable
Use fiber cable to connect FX port of an upper layer converter Fiber Cable Limitations:
SC/LC Converter Models
Multi-mode Half-duplex 412m Multi-mode Full-duplex 2Km
Single-mode Half-duplex 412m Single-mode Full-duplex 10/30/50Km
Table 2-1
Note: The other side of the fiber cable plugg ed into the c onverter’s RX connector at
the near end sh ould plug into the FX device ’s TX connector at the far en d, and vice versa.
Page 11
Publication date: March, 2011
Revision A2
5
3. Operation of Web-based Management
The converter prov id es a web f unc tio n by Ethernet Port (Br o wser) to manage and monitor the port activity. For instance, http ://192.168.1.1, then enter password and click “Login” button.
The default values of Web Smart Media Converter are as follows: IP Address :192.168.1.1 Subnet Mask :255.255.255.0 Default Gateway :192.168.1.254 Password :admin
Fig. 3-1
Page 12
Publication date: March, 2011
Revision A2
6
3-1. Web Management Home Overview
Home Page and Main MENU will be shown up after you fill in “admin” to serve as password an d click the <Login> button. T he main functions will be listed on the left side of a browser. On the top is the fr ont panel view of the converte r. In the middle is the basic S ystem Inform ation. T he m ain f unctio ns wil l be i ntroduc ed in the following sections.
On the front panel, t he LEDs will displa y the status color which is the same as physical hardware. The fiber and TP plug will display the status color as well. Green stands for “Link up” status.
The main functions ar e “Information”, “Loc al Setting”, “Remote Setti ng”, and “Tools”.
Function name:
System Information
Function description:
Show the local and remote device network information.
Fig. 3-2
Parameter description:
Remote Device Control:
Disable (Default): When Remote Device Co ntrol is disabled, the r emote dev ice inform ation
will not be shown on the screen.
Page 13
Publication date: March, 2011
Revision A2
7
Enable: When Remote Device Cont rol is enabled, the rem ote device information
will be shown on the screen.
MAC address:
It is the Ethernet MAC address of the management agent in this device.
Software Version:
It’s a firmware version of this device.
IP address/Gateway/Subnet Mask:
It’s an IP address of the device. Default Setting:
IP Address: 192.168.1.1 Default Gateway: 192.168.1.254 Subnet Mask: 255.255.255. 0
Description:
It is a field for model description.
Serial number:
It is a product serial number.
Hardware Version:
It is a hardware version of product.
Page 14
Publication date: March, 2011
Revision A2
8
3-2. The Function Tree in Web Management
For offering you a clear guide to use this Web Smart Media Con verter, the following is the whole function tree of Web Smart Media Converter in web management. User can refer to the following sections based on the order of this function tree below for more details.
Fig. 3-3
Page 15
Publication date: March, 2011
Revision A2
9
3-3. Local Setting
3-3-1. IP Configurat io n
IP configuration is one of the mos t important configur ations in WEB SMA RT MEDIA CONVERTER. Without the proper setting, n etwork manager will not be abl e to view the device. WEB SMART MEDIA CONVERTER supports both manual IP address setting and automatic IP address setting via DHCP server. When IP address is chan ged, you must r eboot the conver ter to have the s etting taken effect and use the new IP to browse for web management.
Function name:
IP Configuration
Function description:
Set IP address, subnet mask and default gateway for WEB SMART MEDIA CONVERTER.
Fig. 3-4
Fig. 3-5 IP Configuration
Page 16
Publication date: March, 2011
Revision A2
10
Parameter description:
DHCP Client:
WEB SMART MEDIA CONVERTER supports DHCP client used to get an IP address autom atically if you set this function “Enable”. W EB SMART MEDIA CONVERTER will find the DHCP server existed in the network to get an IP address . If this function is set “Disable”, you hav e to input IP address manually.
Default: Disable
IP address:
Users can configure the I P settings and fill in new values if users set the DHCP function “Disable”. Then, click <Apply> button to update it.
Default: 192.168.1.1
Subnet mask:
Set the subnet mask value which is the same as that of network it attaches. For more inf ormation, please also see th e section “IP Address Assignment” in this manual.
Default: 255.255.255.0
Default gateway:
Set an IP address for a gateway to handle those packets that do not meet the rules predefined in a device. If a packet does not meet the criteria for other routers, then it must be sent to a default router. This means any packet with undefined T CP/IP information will be sent to t his device unconditionally.
Default: 192.168.1.254 Description: Input data or model name about this device then click <Apply> button.
Page 17
Publication date: March, 2011
Revision A2
11
3-3-2. Password Setting
Function name:
Password Setting
Function description:
The default user ac count is “ admin” that can not be m odif ied or dele ted and is the only one user account. T he password mus t be ‘a’-‘z’, ‘A’-‘Z’, ‘0’-‘9’ and ‘_’. The max. length is 16 characters. After input the data as Fig. 3-6 click <Apply> button.
The default setting of user account is:
Username: admin
Password: admin
Parameter description:
Old Password: Input the old password New Password: Input new password Confirm: Input the new password again
Fig. 3-6
Page 18
Publication date: March, 2011
Revision A2
12
3-3-3. Converter Configuration
Function name:
Converter Configuration
Function description:
This converter provides the following configurable parameters.
Parameter description:
Jumbo Frame(9K):
If enable this function, the media converter could pass the max. 9KB
packets.
Link Transparent:
Only if link transparent is enabled, the Remote Fault Detect and Link
Loss Carry Forward will take effect.
Remote Fault Detect:
If enable this func tion, when f iber port enab le TS-100 0 and rec eive OAM
packet. This converter will set local UTP port link up or link down
Fig. 3-7 Converter Configuration
Page 19
Publication date: March, 2011
Revision A2
13
according to remote device’s UTP port link status. This function need
enable link transparent first.
Link Loss Carry Forward:
If enable this func tion , whe n the UT P p ort link do wn, t he f iber por t will be
forced link down. And the fiber will be resume when UTP port link up.
This function need enable link transparent first.
Notice
If local MC (Media Co nverter) enables TS1000 an d is configured as
Center Mode, when configuring Jumbo Frame and Link Transparent
functions for local MC, the remote MC will be configured at the
same time even if it is a dump MC. And the configuration of remote
side is the same as local side.
Forward CRC Error Frame:
If enable this function , the CRC error packet will be pass, other wise, the
CRC error packets will be dropped.
Forward Pause Frame:
If this function was e nab le d , this MC wil l f orward pause fram e and r e gard
it as a normal packet.
Management Packet High Priority:
If enable this function , this MC will enable Q OS. W e enable four queu es,
and set queue 3 as strict priority. All management packets, such as
802.3ah OAM packets will be in queue 3 to guarantee bandwidth.
Broadcast Storm Filter, Multicast Storm Filter, Unknown DA Unicast Storm Filter:
If enable this func tion, when too many broadc ast/multicast/unknown DA
unicast packets arrive in a period time, the packets will be dropped.
Page 20
Publication date: March, 2011
Revision A2
14
3-3-4. Port Configuration
Function name:
Port Configuration
Function description:
Change the state and configuration of each port. This page could set local device’s port status, include work mode, flow control ability, ingress and egress rate limit.
Parameter description:
Port:
The TP Port is MEDIA CONVERTER’s Ethernet UTP interface.
The FX Port is MEDIA CONVERTER’s Ethernet Fiber interface.
Link:
Show port current link status:
100F = Speed 100M, Full Duplex Mode
100H = Speed 100M, Half Duplex Mode
10F = Speed 10M, Full Duplex Mode
10H = Speed 10M, Half Duplex Mode
Down = Link Down
Mode:
The Auto Speed algorithm to exchange the capability with the linked
partner. When enabled, the speed, duplex mode and f low control mode
may change. You must have both port configuration of local port and
linked partner be the sam e. If their configuration is different, the link will
not be set up successfull y. In WEB SMA RT MEDIA CONVE RTER, fiber
port supports forced mode only.
Set the mode of speed and duplex. In speed, 10/100Mbps baud r ate is
Fig. 3-8 Port Configuration
Page 21
Publication date: March, 2011
Revision A2
15
available for Fast Ethernet. If the media is fiber, it is always 100Mbps and
the duplex is 100full/auto; if the media is TP, the Speed/Duplex is
comprised of the com bination of speed mode, 10/100Mbps, and du plex
mode, full duplex and half duplex.
Flow Control:
There are two m odes to choose in flow control, Enable and Disable. If
flow control is set “Enable”, both parties can send PA USE frame to the
transmitting device(s) while the receiving port is too busy to handle.
When it is set “Dis able” , flow co ntrol wil l not exis t in the por t. It drops th e
packet if too much to handle.
Default: Enable
Ingress Rate Limit and Egress Rate Limit:
There are some predefined rate settings. If user needs some special
usage, you cou ld input the rate b y yours elf after “User Setting” has bee n
selected from pull down list. Because the rate limit is 64kbps as a
minimal step, the inpu t rate lim it, it sh ould b e divide d ex actly b y 64. If the
rate value can not be div ided exactl y b y 64, f or exam ple 65, t he pr ogram
will be change the rate to 64 automatically.
Default: Not Limit
Page 22
Publication date: March, 2011
Revision A2
16
3-3-5. MIB Counter
Function name:
MIB Counter
Function description:
The page shows loc al de vice’s MIB co unters. If c lick the “clear” button , all MI B counters will be clear to zer o. Click ther efres h” button, s how the curr ent MIB
counters again.
Parameter description:
TP:
To display the converter UTP port counter information.
FX:
To display the FX (The converter’s Fiber port) port counter information.
CPU:
To display the CPU (The converter’s CPU) counter information.
Fig. 3-9
Page 23
Publication date: March, 2011
Revision A2
17
3-3-6. VLAN
The Converter supports Tag-based VLAN (802.1Q). VLAN configuration is used to partition your LAN into small ones as your demand. Properly configuring it, you can gain not only improving security and increasing performance but greatly reducing VLAN management.
3-3-6-1. VLAN Group
Function name:
802.1Q VLAN Group
Function description:
If enable VLAN functions, user could set 16 VLAN entries. Each VLAN entry could set VID and member port. The VID should be 1~4094.Others when the member port is evoked, this port will belongs to this VLAN group.
Fig. 3-10
Page 24
Publication date: March, 2011
Revision A2
18
Parameter description:
VLAN Group:
To display the VLAN Group Index. The maximum is 16 and the range is
from 0 to 15.
VID:
VLAN identifier. Each tag-based VLAN group has a unique VID. It
appears only in tag-based and Double-tag mode.
TP:
To evoke the TP (The converter’s UTP port) to become a VLAN group
member.
FX:
To evoke the FX (The converter’s Fiber port) to become a VLAN group
member.
CPU:
To evoke the CPU (The converter’s CPU) to become a VLAN group
member. It means that CPU needs to become a VLAN member for
management purpose.
Page 25
Publication date: March, 2011
Revision A2
19
3-3-6-2. VLAN Per Port Se tt in g
Function name:
802.1Q VLAN Per Port Setting
Function description:
In this page, we could set each port’s PVID and egress tag behavior.
Parameter description:
Egress Link Type:
Replace Tag:
The switch will remove VLAN tags from packets then add new tags to them. The inser ted tag is the ingress port’s Def ault tag”,
which is indexed by port Port based VLAN index”. This is a replacement processing for tagged packets and an insertion for
untagged packets.
Remove Tag:
The switch will remove VLAN tags from packets, if they are tagged when these pack ets are output. The switc h will not modif y packets received without tags.
AddTag:
The switch will add VLAN tags to pack ets, if they are not tagged when these packets are output on this port. The switch will not add tags to packets already tagged. The inserted tag is the ingress port’s Def ault tag, which is indexed b y port’s “Port based VLAN index”.
Don’t Touch Tag:
Do not insert or remove VLAN tags to/from packet which is output on this port.
Port VLAN Entry:
Select Port based VLAN index. The number means VLAN table entry index, not VID.
Ingress Filter:
Fig. 3-11
Page 26
Publication date: March, 2011
Revision A2
20
Enable or Disable VLAN ingress filter.
Page 27
Publication date: March, 2011
Revision A2
21
3-3-7. Q-in-Q
Function name:
Q-in-Q
Function description:
This page could configure Q in Q function.
Fig. 3-12
Fig. 3-13
Page 28
Publication date: March, 2011
Revision A2
22
Parameter description:
Out Layer VLAN Tag:
User defined Q-in-Q out layer VLAN tag Ether type.
Out Layer VLAN VID:
User defined Q-in-Q out layer VLAN tag VID
VLAN Tag Priority Decision:
Decide out layer VLAN Tag’s priority, use internal VLAN tag priority or
use IP remarking priority.
Q in Q direction:
Select Q in Q direction, which port adds tag, and which port removes tag.
“TP Port Add Q in Q Tag F X Port Rem ove Tag” or “FX Port Add Q in Q
Tag TP Port Remove Tag”.
Page 29
Publication date: March, 2011
Revision A2
23
3-4. Remote Setting
Fig. 3-14
3-4-1. TS-1000 Functions
TS-1000 Functions include “TS1000 Setting”, “Loopback Test”, “Remote
Device Reset”, “Remote Port Information”, “Remote Port Setting” five functions.
3-4-1-1. TS-1000 Setting
Function name:
TS-1000 Setting
Function description:
This page could enable /disable TS1000 functio n, and set TS-1000 mode as terminal or center. If TS1000 is enabled, the TS1000 information will be displayed in the web. And if it’s in center mode, and remote device is in terminal mode, remote TS1000 information will also be shown in the page.
Page 30
Publication date: March, 2011
Revision A2
24
Fig. 3-15
Page 31
Publication date: March, 2011
Revision A2
25
3-4-1-2. Loopback Test Function name:
Loopback Test
Function description:
This page could start TS1000 loopback function. User could set TS1000 loopback packet number.
Fig. 3-16
Parameter description:
Send packet number:
After input the number between 1 and 255, click the “<Apply>” button. Result:
Pass or not as Fig. 3-16 Result Counter: Show packet number and pass or not
Page 32
Publication date: March, 2011
Revision A2
26
3-4-1-3. Remote Device Reset Function name:
Remote Device Reset
Function description:
We could reset remote device through this function. Before that “TS1000 ability” should be enabled, local device should be set in center mode and remote device should be set in terminal mode.
Fig. 3-17
Parameter description:
Reset button: After click this button, if success shown as Fig. 3-17.
Page 33
Publication date: March, 2011
Revision A2
27
3-4-1-4. Remote Port Information
Function name:
Remote Port Information
Function description:
This page shows remote device port information.
Fig. 3-18
3-4-1-5. Remote Port Setting
Function name:
Remote Port Setting
Function description:
In this page, user could enable/disable remote device’s UTP port, change remote device port’s speed & duplex and flow control ability. Fiber port should not be disabled.
Fig. 3-19
Page 34
Publication date: March, 2011
Revision A2
28
3-4-2. 802.3ah Function
This menu includes “802.3ah Configuration”, “Loopback Test”, “802.3ah Status” three functions.
3-4-2-1. 802.3ah Configuration
Function name:
802.3ah Configuration
Function description:
This page could set IEEE802.3ah OAM function. User could enable/disable
802.3ah function and set its mode as passive or active mode.
Fig. 3-20
Parameter description:
802.3ah Function: Enable/Disable
802.3ah Mode:
Active/Passive Remote Loopback: Enable/Disable
After select the parameters, then click the <Apply> button and <refresh> button to show “Discovery Status” and “Fiber Port Status”.
Page 35
Publication date: March, 2011
Revision A2
29
3-4-2-2. Loopback Test Function name:
Loopback Test
Function description:
This page could start 802.3ah loopback test. User could configure packet length and packet number.
Fig. 3-21
Parameter description:
Send Packet Number: Available value:1~255 Packet Length (Not include CRC):
Available value:60~1514
After input the parameters, then click the <Apply> button. Test result(Fig. 3-22, Fig. 3-23)
Fig. 3-22
Fig. 3-23
Page 36
Publication date: March, 2011
Revision A2
30
3-4-2-3. 802.3ah Status
Function name:
802.3ah Status
Function description:
This page shows 802.3ah status information.
Fig. 3-24
Page 37
Publication date: March, 2011
Revision A2
31
3-5. Tools
This menu contains “System Reboot”, “Save and Restore”, “Firmware
Upgrade” and “Logout” four functions.
Fig. 3-25
3-5-1. System Reboot
Function name:
System Reboot
Function description:
Click this function to reboot the device.
Fig. 3-26
Parameter description:
OK:
To restart the device.
Cancel:
To exit the function.
Page 38
Publication date: March, 2011
Revision A2
32
3-5-2. Save and Restore
Function name:
Save and Restore
Function description:
SaveToFlash: Save local configuration to flash. LoadFromFlash: Restore last saved configuration. ResetToFactory: Factory default setting.
Fig. 3-27
Page 39
Publication date: March, 2011
Revision A2
33
3-5-3. Firmware Upgrade
Function name:
Firmware Upgrade
Function description:
In this page, user co uld update t he firm ware by the web browser. User could click the browser button, select the new firmware image file, and then the new code image will be bur ned into th e flas h, and rese t the devic e to use th e new firmware.
Fig. 3-28
Parameter description:
Browse: To select the location of the firmware file.
Upgrade: To execute “firmware upgrade” function.
3-5-4. Logout
Function description:
Logout
Function description:
Exit Web management.
Fig. 3-29
Parameter description:
OK: T o exit Web management.
Cancel: To cancel logout action.
Page 40
Publication date: March, 2011
Revision A2
34
4. Maintenance
4-1. Resolving No Link Conditions
The possible causes for a no link LED status are as follows:
The attached device is not powered on The cable may not be the correct type or is faulty The installed building premise cable is faulty The port may be faulty
4-2. Q&A
1. Computer A can connect to Computer B, but cannot connect to Computer C through the WEB SMART MEDIA CONVERTER Converter.
The network device of Computer C may fail to work. Please check the
link/act status of Computer C on the LED indicator. Try another network device on this connection.
The network configuration of Computer C may be something wrong. Please
verify the network configuration on Computer C.
2. The uplink connection function fails to work.
The connection ports on another must be connection ports. Please check if
connection ports are used on that converter.
Please check the uplink setup of the WEB SMART MEDIA CONVERTER to
verify the uplink function is enab le d.
Page 41
Publication date: March, 2011
Revision A2
35
Appendix A
Technical Specifications
Hardware Specification
Feature Detailed Description
Power requ irement
5VDC
Power consumption
1.5 W
Fiber Connector
RC-1001:SC, LC / RC-1001A:SFP
Ambient Temperature
0 to 50C
Humidity
5% to 90%
Dimensions
70.3(W) x 26.2( H) x 94(D) mm
Weight
0.44kg
Safety
Comply with FCC Part 15
Class A & CE Mark Approval
Shock IEC60068-2-27 Freefall IEC60068-2-32 Vibration IEC60068-2-6
Note: Any specification is subject to change without notice.
Loading...