Rubine RCF-SP900-5BL-GC Instruction Manual

5 6"
Instruction Manual
SAFETY GUIDELINES AND INSTALLATION PROCEDURES
RCF-SP900-5BL
REMOTE CONTROL CEILING FAN WITH LIGHT
PARTS
Page 1
1. DOWNROD 1
2.TOP CANOPY 1 1
3
.COUPLING COVER
4
.
1
5
.BLADES
5
COMPONENTS
SCREW PACKAGE
SCREW PACKAGE
10.BLADE ATTACHMENT SCREWS
11
6.
1
QUANTITY
11.EXPANSION J HOOK
1
10
1 1
1 2
12.BALANCING KIT 1
2
3
5
1
HI
MED
LOW
OFF
1H
3H
6H
6
7
8
DIGITAL TOUCH SCREEN REMOTE (COMES WITH 3V BATT X2)
7.
1
REMOTE HOLDER WITH 2 MOUNTING SCREWS
WHAT YOU HAVE
PARTS QUANTITY
8
.
1RF RECEIVER
9
.
1
Please checkout following parts after opening the box:
FAN SIZE VOLTAGE
CARTON WEIGHT
MAX. FAN POWER
MAX SPEED (RPM)
PRODUCT WEIGHT
220 240V/50Hz 80W 250+-10%
8.1kg 9.1kg
FAN MOTOR &
LED LAMP (7W)
4
9
GLASS SHADE
56”
LIGHT
POWER
7W Led
Double pole single throw switch(Breaker Switch)
Earth
Ceiling Fan
Wall Switch (OFF/ON)
240VAC/50Hz Power Supply
Page 2
1 ) Please do not install the ceiling fan at high humidity areas. 2 ) Distance between fan blades and ground must be at least 2.5 meter and above. 3 ) Do not touch fan blades with any objects when the ceiling fan is spinning. 4 ) To minimize the chances of electrical shock, power switch must be OFF before installing
or dismantling the ceiling fan or any electrical wiring connection. 5 ) All electrical connections must conform to the national electrical safety codes. To prevent
electrical shock, earth wire must be installed correctly (suitable for power supply of
240V AC/50Hz). 6 ) To ensu
re your personal safety and optimize functions of the ceiling fan, assembly and
installation by qualified technician is highly recommended. 7 ) Only direct connection to wall switch is allowed. Please refer to diagram below.
WARNING
1 ) Do not bend the blade holders during installation, blades balancing or fan cleaning. 2 ) To prevent accidents, power switch must be OFF before ceiling fan installation. 3 ) Ceiling fan installation and electrical wiring must be done by qualified technician in
accordance with all applicable codes and air conditioning engineers (ASHRAE) or the local qualified authorities.
4 ) Be cautious when drilling the wall to avoid damaging electrical wiring and other hidden parts.
5 ) Ceiling fan must be hooked on concrete ceiling. Do not install the ceiling fan on plaster ceiling or any types of drywall ceilings. During ceiling fan installation, all screws must be tightened at all allocated parts.
A). TO ENSURE YOUR PERSONAL SAFETY, PLEASE READ THROUGH THE INSTRUCTION MANUAL BEFORE USE
B). SAFETY GUIDELINES
8 ) This product is not provided with cord, plug or other means for disconnection from the supply. Connecting or changing power cord or lead wire, must be done by qualified personnel in order to avoid hazard.
9 ) This appliance is not i
ntended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
10 ) Children should be supervised to ensure that they do not play with the appliance. 11 )
The ceiling fan must be installed with means for disconnection incorporated in the fixed wiring(wall switch)in accordance with the wiring rules.
Page 3
Remove screws on plastic blocks. Put aside
these screws
for fan blade installation in
Step 7.
Motor
Plastic Block
Screw
(Must Remove)
INSTALLATION PROCEDURES
STEP 1 ( See Diagram 1 )
Note:-
1. Plastic blocks must be removed and discarded.
DIAGRAM 1
Before ceiling fan installation,please go through the procedures in detail with picture diagram as reference.
1 ) Remove 1st hex-head screw along with the fixings (pin, metal nut, lock washer and metal washer) from the downrod.
2 ) Remove the pin on 2nd hex-head screw and loosen the other fixings.
1 ) Lift the fan until the hanging wheel seat on the mounted J hook.
2 ) Install the 1st hex-head screw together with fixings.
3 ) Tighten up the 2nd hex-head screw and fixing.
DIAGRAM 2
DIAGRAM 4
(Tighten)
Hook
The 1st
Hex-head Screw
The 2nd
Hex-head Screw
Metal Washer
Pin
Metal Nut
Lock Washer
Fixings
1 ) Loosen 2 screws on the motor coupling.
2 ) Insert the downrod through top canopy and coupling cover.
3 ) Thread the safety cable through the downrod.
4 ) Connect both wire and light connectors from downrod to fan motor.
5 ) Lock the downrod to the motor coupling, tighten up with 2 hex-head screws and fixings.
6 ) Tighten 2 screws on the motor coupling.
7 ) Slide down the coupling cover until it rest on top of the fan housing.
STEP 2 (See Diagram 2)
STEP 3 (See Diagram 3)
STEP 4 (See Diagram 4)
WARNING:
DIAGRAM 3
Safety Cable
C
Wire
Light Connector
onnector
T
7w Led
op Canopy
Coupling Cover
Screw x 2
Hex-head Screw
Motor Coupling
Screw (Loosen)
Downrod
Installation without proper procedures as above mentioned might result to fan loosening or falling.
The 1st Hex-head Screw
The 2nd Hex-head Screw
Pin
Terminal Block
Fixings
Pin
Metal Nut
Lock Washer
Metal Washer
2 Metal nuts
Note:-
2.
Hook must be installed on concrete ceiling.
(2.5 Nm torque for hex-head screws and Metal Nut)
1. Remember to lock the pin after tightening hex-head screws.
Page 4
STEP 5 (See Diagram 5)
DIAGRAM 4
Receiver
Ceiling
Ceiling
Ceiling
Receiver
Receiver
Receiver
Receiver
Brown Wire
(TO MOTOR L)
Blue W
(Orange Wire) (FOR LIGHT)
ire
(TO MOTOR N)
Red / Brown Wire
(Incoming LIVE Wire)
Black / Blue Wire
(Incoming NEUTRAL Wire)
Green Wire
(Incoming EARTH Wire)
Red Wire (AC in L)
Black Wire (AC in N)
Terminal Block (marked )
“L”
Terminal Block (marked )
“N”
Terminal Block (marked )
“ ”
FROM TO
!
Connect the Motor Wiring to Receiver first!
Connect wiring as below:-
LIVE wire
(Red / Brown)
NEUTRAL wire
(Black / Blue )
Terminal Block (marked
)
SUPPLY CIRCUIT
EARTH wire
L N
L N
L
N
FOR LIGHT
FOR LIGHT
Orange
Green
Brown
Blue
Receiver
Fan motor
Fan motor
Fan blade
Fan blade
Screw
Screw
Page 5
Fit the connected receiver into top canopy. Then, tighten the screw on downrod.
STEP 6 ( See Diagram 6 )
STEP 7 ( See Diagram 7 )
STEP 8 ( See Diagram 8 )
DIAGRAM 6
DIAGRAM 7
DIAGRAM 8
Tighten the fan blade onto the motor housing by using the screws which you removed from the plastic plate in Step 1.Repeat proces for the other fan blades.Make sure all the screws are tighten.
Install the glass shade by twisting clockwise ( To unlock, twist anticlockwise).
Glass shade
Light kit (Led lamp included)
Downrod
Receiver
T
Screw
op Canopy
Page 6
WARNING!
FASTEN THE SAFETY CABLE TO THE MOUNTED J HOOK FOR SAFETY PURPOSES.
Page 7
FLOOR
MIN 2.5m
SAFETY TIPS
Please ensure the distance between fan blade and ground must be at least 2.5 meter and above.