The AutoFlush®sends out a continuous infrared beam that is reflected back by the presence of a person in front of the urinal or toilet.“Object Lock”technology differentiates between someone walking past the unit or actually using the fixture.
AUTOFLUSH®COMPONENTS
Sensor
Adjustment Tool
Allen Wrench
NOTE: Fits Sloan and Zurn flush handles. To fit other flush handles contact TC customer service at 800-551-5155.
Courtesy Flush Button
Step 1.
If flush handle is leaking, replace before installing AutoFlush
Using the supplied Allen wrench, remove battery compartment.
®
-
+
+
-
2.1 Open hinged screw covers
and loosen screws to leave a
1
4”gap between the base
and mounting cover
2.2 Slide the AutoFlush
the flush handle and secure the mounting clamp over the existing handle base.
NOTE: If the unit is on a high mount toilet flush valve where the flush han­dle is approximately 40”above the floor,you should rotate the AutoFlush down to ensure sensor is directed at user.
®
on to
Step 3.Step 2.
2.1a
2.2a
®
2.1b
2.2b
1/4” Gap
Install 4 “C”cell alkaline batteries into the battery compartment not­ing the battery position marks on the inside of the compartment. Slide the battery compartment into the AutoFlush compartment with Allen wrench. The last three turns of the wrench will activate the AutoFlush
®
unit and secure
®
unit.
--
++
+
-
1ON2
Courtesy Manual Flush Button
(Toilet Model Only)
Allows manual activation of flush if needed.
Battery LED (Yellow) Flashing LED = Change Batteries
Object Lock Sensor- Detects User or Object
User-In-View LED (Green) Flashes 3 Times = User acknowledged & ready to operate.
1ON2
-
+
Sensor Range
Adjustment Screw
Short
Long
Operation Features*
Switch 1
24 Hours Flush Off
Switch 2
Alarm Tone Off
Switch 1
24 Hours Flush Off
Switch 2
Alarm Tone On
Switch 1
24 Hours Flush On
Switch 1
24 Hours Flush On
Switch 2
Alarm Tone On
Switch 2
Alarm Tone Off
Sensor Range Reset Button
Sensor Range
Adjustment
1ON2
1ON2
1ON21ON2
Step 4.
ACTIVATION
Your AutoFlush®unit comes preset from the facto­ry.If special circumstances require adjustment of the activation distance,see Appendix A— Adjusting Your AutoFlush
The AutoFlush
®
unit has a 7 minute start-up
®
.
sequence in which the Object Lock Sensor will activate the User-In-View
ggrreeeenn LL..EE..DD..
continu­ously as long as a user or object is in view. After the start-up sequence is completed and when the Object Lock Sensor has a user in view,the User-In-
ggrreeeenn LL..EE..DD..
View
will flash 3 times once the user
is in front of the unit for a minimum of 5 seconds.
4.3
--
++
+
-
4.1
4.2
1ON2
Use Allen wrench to remove battery compartment tray.
Remove cover by rotating the cover up at the end over the battery compartment and slide out.
Remove rubber seal.
VISUAL INDICATOR GUIDE
USER-IN-VIEW L.E.D. (Green light flashes 3 times, after
5 second delay, when a user is in view. The green light flashes constantly when a user is in view during the 7 minute start up sequence).
BATTERY L.E.D. (Yellow light flashes indicating it is time to replace batteries with 4 new “C” cell alkaline batteries).
OBJECT LOCK SENSOR (Detects user or object).
COURTESY MANUAL FLUSH BUTTON
(Allows manual activation of flush when needed—Toilet model only).
APPENDIX A - ADJUSTING YOUR AUTOFLUSH
®
TO CHANGE ACTIVATION DISTANCE FOR THE OBJECT LOCK SENSOR:
Remove battery compartment. See Step 1.
1
2 Remove cover. See illustration 4.2.
3 Replace battery compartment in AutoFlush®to activate unit and remove rubber seal. See Step 3.
4 Press sensor range reset button as indicated in Appendix A. NOTE:the green L.E.D.will flash continuously
when it has an object in view for the seven minute reset period.
5 Stand at desired activation distance.
6 Use provided sensor adjustment tool and turn Sensor Range Adjustment Screw all the way down (count-
er clockwise) and then turn slowly up (clockwise) until green L.E.D.begins to flash.
7 Ensure Object Lock Sensor is not detecting stall door or wall by closing door,stepping out of sensor path
and making sure green L.E.D.is not flashing. If sensor locks onto door or wall, unit will not flush properly. Shorten activation distance.
8 Remove battery compartment,and replace cover. Replace battery compartment tray to reactivate
AutoFlush
9 After 7 minute start-up sequence,the green L.E.D.will flash only 3 times when a user is in view
(after a 5 second delay).
®
unit.
TROUBLE SHOOTING GUIDE
Green L.E.D.(light) flashes 3 times when there are no users
Green L.E.D.(light) flashes continuously when Object Lock Sensor is activated by a user
PROBLEM CAUSE SOLUTION TO PROBLEM
Yellow L.E.D.(light) flashes
Not enough water to fixture or too much water to fixture
Flush valve will not operate
Water continuously runs
Unit does not flush even after Sensor Range has been adjusted
Front of Object Lock Sensor is covered or Object Lock Sensor is set too far out,detecting the opposite wall or door as a user
AutoFlush®unit is in 7 minute start up mode (when first activated) or Sensor Range Reset Button has been depressed
Batteries are low and need replacing
Flush valve diaphragm damaged or valve control stop improperly adjusted
Object Lock Sensor range set too close to AutoFlush®, batteries are dead,or water supply is turned off
Dirt or debris preventing diaphragm from func­tioning properly
Dead batteries
Remove item covering sensor or adjust Object Lock Sensor activation distance.(See Appendix A ­Adjusting the AutoFlush)
Green L.E.D.(light) will flash only 3 times acknowledging a user is in view after the 7 minute start up mode
Replace batteries. Use ONLY alkaline batteries
Consult flush valve manufacturers directions
Adjust Object Lock Sensor—Replace batteries—Turn water on.If the AutoFlush®does not begin to function, call (800) 551-5155 for technical assistance.
Consult flush valve manufacturer’s directions
Replace batteries.
Have Questions or Need Supplies?
Call Toll Free:1-800-551-5155
World Headquarters:
Serving North & South America
Technical Concepts LLC.
1301 Allanson Road Mundelein, Illinois 60060 U.S.A.
®
847-837-4100 Fax: 1-800-551-5046
Toll Free: 1-800-551-5155 Web: www.technicalconcepts.com Email: info@technicalconcepts.com
European Headquarters:
Serving Europe, Africa & Middle East
Technical Concepts International Ltd.
Pin Green Business Park Eastman Way Stevenage, Herts SG1 4UH, England +44 (0)870 568 6824 Fax: +44 (0)1438 311200
Asian Headquarters:
Serving Asia & Pacific
Technical Concepts Asia
51 (B) Lorong Perindustrian Bukit minyak 9 14100 Bukit Mertajam, Penang, Malaysia (60) 4 508 5008 Fax: (60) 4 508 5001
108112
Loading...