RTS Zeus III User Manual

Zeus III Matrix Intercom
User Manual
Up to and including version 1.0.0
F.01U.193.289
Rev. 05
OCTOBER/2015
2 Zeus III
PROPRIETARY NOTICE
The product information and design disclosed herein were origi­nated by and are the property of Bosch Security Systems, Inc. Bosch reserves all patent, proprietary design, manufacturing, repro­duction, use and sales rights thereto, and to any article disclosed therein, except to the extent rights are expressly granted to others.
THE EXCLAMATION POINT WITHIN THE TRIANGLE IS A WARNING SIGN ALERTING YOU OF IMPORTANT INSTRUCTIONS ACCOMPANYIN G THE PRODUCT.
COPYRIGHT NOTICE
Copyright 2015 by Bosch Security Systems, Inc. All rights reserved. Reproduction, in whole or in part, without prior written permission from Bosch is prohibited.
*All other trademarks are property of their respective owners.
WARRANTY AND SERVICE INFORMATION
For warranty and service information, refer to the appropriate web site below:
RTS Intercoms .............................. www.rtsintercoms.com/warranty
RTS Digital RTS TW AudioCom RadioCom
Intercom Headsets.....................................................www.telex.com
THE LIGHTNING FLASH AND ARROWHEAD WITHIN THE TRIANGLE IS A WARNING SIGN ALERTING YOU OF “DANGEROUS VOLTAGE” INSIDE THE PRODUCT.
SEE MARKING ON BOTTOM/BACK OF PRODUCT.
WARNING: APPARATUS SHALL NOT BE EXPOSED TO DRIPPING OR SPLASHING AND NO OBJECTS FILLED WITH LIQUIDS, SUCH AS VASES, SHALL BE PLACED ON THE APPARATUS.
WARNING: THE MAIN POWER PLUG MUST REMAIN READILY OPER­ABLE.
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, GROUNDING OF THE CENTER PIN OF THIS PLUG MUST BE MAINTAINED.
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER. NO USER­SERVICABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
CUSTOMER SUPPORT
Technical questions should be directed to:
Customer Service Department Bosch Security Systems, Inc. www.telex.com
TECHNICAL QUESTIONS EMEA
Bosch Security Systems Technical Support EMEA
http://www.rtsintercoms.com/contact_main.php
DISCLAIMER
The manufacturer of the equipment described herein makes no expressed or implied warranty with respect to anything contained in this manual and shall not be held liable for any implied warranties of fitness for a particular application or for any indirect, special, or consequential damages. The information contained herein is subject to change without prior notice and shall not be construed as an expressed or implied commitment on the part of the manufacturer.
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPRATUS TO RAIN OR MOISTURE.
WARNING: TO PREVENT INJURY, THIS APPARATUS MUST BE SECURELY ATTACHED TO THE FLOOR/WALL/RACK IN ACCOR­DANCE WITH THE INSTALLATION INSTRUCTIONS.
This product is AC only.
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
Zeus III 3
Important Safety Instructions
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
Bosch Security Systems, Inc.
Technical Manual
F.01U.193.289
Rev. 05
4 Zeus III
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
Table
of
Contents
INTRODUCTION ........................................................................................................................ 9
General Description ................................................................................................................................ 9
Features .................................................................................................................................................. 9
Reference View ...................................................................................................................................... 10
Specifications ........................................................................................................................................ 11
Indicators and Controls ........................................................................................................................ 12
Connector Pinouts ................................................................................................................................. 15
Dip Switches .......................................................................................................................................... 18
2-Wire Settings in AZedit ...................................................................................................................... 22
Zeus III and GPIO-16 ........................................................................................................................... 24
Zeus and Accessory Dimensions ........................................................................................................... 25
CABLES ..................................................................................................................................... 27
Cable Requirements .............................................................................................................................. 27
INSTALLATION ....................................................................................................................... 31
Requirements ......................................................................................................................................... 31
Default Ethernet IP Addresses .............................................................................................................. 31
Initial Power Up .................................................................................................................................... 32
Zeus III Configuration .......................................................................................................................... 33
Typical System Installations .................................................................................................................. 41
PARTY LINE INTRODUCTION AND OPERATION ............................................................ 45
Party Line Operation ............................................................................................................................ 45
ZEUS III AND VOX .................................................................................................................. 51
Bosch Security Systems, Inc.
Technical Manual
F.01U.193.289
Rev. 05
6 Zeus III
CHANGING THE IP PROPERTIES ON YOUR PC .............................................................. 57
UPL RESOURCE GUIDE .........................................................................................................61
Notes ..................................................................................................................................................... 69
Bosch Security Systems, Inc.
Technical Manual
F.01U.193.289
Rev. 05
List
of
Figures
FIGURE 1. Zeus III Front and Rear Reference View .......................................................................... 10
FIGURE 2. Red LED Status, Orange Status, and Green Status Indicator ........................................... 12
FIGURE 3. CH A and CH B 2W/Party Line LEDs and Controls ........................................................ 13
FIGURE 4. Power 1 and Power 2 Status LEDs ................................................................................... 14
FIGURE 5. Typical GPI input connection ........................................................................................... 17
FIGURE 6. Typical GPI output connection .........................................................................................17
FIGURE 7. Screw locations on the Zeus III unit ................................................................................. 18
FIGURE 8. Dip Switch Locations ........................................................................................................ 19
FIGURE 9. S1 Dip Switch ................................................................................................................... 20
FIGURE 10. S2 Dip Switch ................................................................................................................... 21
FIGURE 11. 2-Wire Settings Page ......................................................................................................... 22
FIGURE 12. Keypanel / Ports Window ................................................................................................. 23
FIGURE 13. Zeus and Accessory Dimensions ...................................................................................... 25
FIGURE 14. Connector Numbering ....................................................................................................... 28
FIGURE 15. Cable Requirements .......................................................................................................... 28
FIGURE 16. Configuration Computer Cable .........................................................................................28
FIGURE 17. Trunking Configuration Cable .......................................................................................... 28
FIGURE 18. GPIO-16 Interconnect Cable ............................................................................................. 28
FIGURE 19. GPIO-16/PAP/LCP Interconnect Cable ............................................................................ 29
FIGURE 20. LCP Interconnect Cable .................................................................................................... 29
FIGURE 21. RJ-45 Straight Cat-5 and RJ-45 Cat-5 Crossover Cable ................................................... 29
FIGURE 22. Apply power to the Zeus III. ............................................................................................. 32
FIGURE 23. Serial Connector ................................................................................................................ 33
FIGURE 24. Serial Connection – Communications Window ................................................................ 34
FIGURE 25. USB Connector ................................................................................................................. 35
FIGURE 26. USB Connection – Communication Window ................................................................... 36
FIGURE 27. Straight Cat-5 Ethernet Connection .................................................................................. 37
FIGURE 28. Communications Window – Straight Cat-5 Ethernet Cable ............................................. 38
FIGURE 29. Available Intercoms Window ...........................................................................................38
FIGURE 30. Crossover Cat-5 Connection ............................................................................................. 39
FIGURE 31. Communications Window – CAT-5 Crossover Cable ...................................................... 39
FIGURE 32. Ethernet Setup Window .................................................................................................... 40
FIGURE 33. 2-Wire Channel A and B Configuration ........................................................................... 41
FIGURE 34. Audiocom (Balanced) Mode Configuration for Single Channel System ......................... 42
FIGURE 35. ClearCom (Unbalanced) Mode Configuration .................................................................. 43
FIGURE 36. Keypanel Configuration .................................................................................................... 44
FIGURE 37. Trunking Configuration .................................................................................................... 44
FIGURE 38. Zeus III 4-Wire and 2-Wire Port Allocation ..................................................................... 45
Bosch Security Systems, Inc.
Technical Manual
F.01U.193.289
Rev. 05
8 Zeus III
FIGURE 39. Input/Output Gain Window .............................................................................................. 46
FIGURE 40. User Programmable Statements Window – AZedit ......................................................... 47
FIGURE 41. Edit UPL Statement Window – AZedit ........................................................................... 48
FIGURE 42. Naming the UPL Statement .............................................................................................48
FIGURE 43. Configure the Input Action .............................................................................................. 49
FIGURE 44. Configure the Output Action ............................................................................................ 49
FIGURE 45. VOX Window .................................................................................................................. 51
FIGURE 46. Open the Local Area Connection Status Window ........................................................... 58
FIGURE 47. Open the Local Area Connection Properties Window ..................................................... 59
FIGURE 48. Enter the IP Address of the Zeus III. ................................................................................60
FIGURE 49. Edit UPL Statement Window ........................................................................................... 62
Bosch Security Systems, Inc.
Technical Manual
F.01U.193.289
Rev. 05
CHAPTER 1
Introduction
General Description
Introducing a totally re-engineered Zeus Intercom System—Zeus III is the next generation of small intercom system units, giving smaller systems more options for their intercom configurations. We; now have 32 channels IN/OUT and two (2) configurable party-line channels. This system is excellent for smaller installations, as well as OB (Outside Broadcast) vans. Its compact size is perfect for small environments with limited space. With the addition of Ethernet, the Zeus III can be configured from virtually anywhere on the network using AZedit Intercom software. Alternatively, the Zeus III can be directly connected to AZedit through the use of the USB connector on the front panel. The Zeus II’s 24 DB-9 connectors have been replaced with 32, RJ-45 connectors.
Features
Redundant Power Supplies The unit comes with two (2) completely independent power supplies powered from
separate AC (Alternating Current) feeds. Because of the extremely low power consumption, the use of UPS (Uninterrupted Power Supply) units is possible.
USB Port The USB (Universal Serial Bus) port is used for the AZedit Intercom software system
configuration.
Trunk Capable Using the dedicated DB-9 trunk connector with standard RS485 protocol, the Zeus III is
able to communicate in a trunked system.
10 Additional Audio Channels Expanding on the Zeus II’s 24-channel unit, we have added 10 additional audio channels
to the Zeus III; eight (8) channels of audio IN and OUT, as well as two (2) channels that can be configured for party line use. The two (2) party-line channels interface two separate 2-wire lines to 4-wire lines. From the front panel, it can be configured for RTS, Audiocom (Balanced), or ClearCom (Unbalanced) mode.
Remote Configuration With the addition of Ethernet to the Zeus III unit, you can now remotely configure your
Zeus III intercom system using the AZedit Intercom System software.
Dynamic Keypanel Addressing Zeus III now automatically addresses keypanels when they are connected to
the Zeus III frame. This eliminates the need for setting keypanel addresses and maintaining port allocations.
Relays New relay connection supports Relay 1 and Relay 2.
Simultaneous Download Faster downloads to multiple ports supporting the same type of keypanels.
Bosch Security Systems, Inc.
Technical Manual
F.01U.193.289
Rev. 05
10 Introduction Zeus III
Reference View
FIGURE 1. Zeus III Front and Rear Reference View
1. Status LED - 2-color status LED, for a more detailed description see “Status LEDs” on page 12.
2. USB Connector
3. Recessed Reset Button - Resets the Zeus III to its default configuration.
4. Channel A Peak LED - If within the normal range of operation, the LED lights green, if the operating range is above the
normal range the LED lights red. For more information, see “CH A and CH B 2W/Party Line LEDs and Controls” on page 13.
5. Channel A Channel Selector - Using a flathead screwdriver, turn the indicator to the channel mode you want to operate.
6. Channel A Channel LEDs - When lit green, the channel mode is selected.
7. Channel B Peak LED - If within the normal range of operation, the LED lights green, if the operating range is above the
normal range the LED lights red. For more information, see “CH A and CH B 2W/Party Line LEDs and Controls” on page 13.
8. Channel B Channel Selector - Using a flathead screwdriver, turn the indicator to the channel mode you want to operate.
9. Channel B Channel LEDs - When lit green, the channel mode is selected.
10. Power 1 LED - When lit green, power supply 1 is operating normally. When unlit, the power supply is bad.
11. Power 2 LED - When lit green, power supply 2 is operating normally. When unlit, the power supply is bad.
12. AC Connector
13. AC Connector
14. GPI Connector - 25-pin Female connector. For pin outs, see Table 8 on page 16.
15. GPIO-16/PAP/LCP Connector - DB-9 Female connector. For pin outs, see Table 5 on page 15.
16. Relays 1 & 2 Connector - DB-9 male connector. For pin outs, see Table 6 on page 16.
17. CH A Connector - 3-pin XLR Female. For pin outs, see Table 7 on page 16.
18. CH B Connector - 3-pin XLR Female. For pin outs, see Table 7 on page 16.
19. Port Connectors - 32, RJ-45 port connectors. For pin outs, see Table 2 on page 15.
20. Trunk/To PC Connector - DB-9 Female connector. For pin outs, see Table 3 on page 15.
21. Ethernet Connector - RJ-45 Connector. For pin outs, see Table 4 on page 15.
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
Zeus III Introduction 11
Specifications
MATRIX
Description:
32 keypanel ports, 2-party line ports with call signaling
Conversion:
48.0kHz, 24-bits
Programming:
AZedit via Windows
Memory:
Non-volatile Flash
Communication:
USB and Ethernet interface
AUDIO PERFORMANCE
Keypanel Ports
Signal Type:
Balanced
Nominal Level:
8dBu
Maximum Level:
20dBu
Input Impedance:
22k
Output Impedance:
600
SNR at 20dBu(A-weighted):
>85dB
THD+N at 20dBu, 1kHz (unweighted):
<0.007%
Frequency Response at 20dBu:
within ±1dB from 50Hz - 20kHz
Crosstalk at 20dBu:
< -80dBu
Note: All measurements performed using an Audio Precision System 1 Dual Domain System at f=1kHz and Level=20dBu. Measurement bandwidth= 20Hz to 20kHz.
Party Line Ports
Nominal Operating Levels:
Audiocom: 1 VRMS
RTS/TW/ClearCom: 775mVRMS
Nominal Input/Output:
5k
Frequency Response:
200Hz to 3.5kHz, ±4dB
THD:
<1% at channel output with nominal input
DATA PORTS
Keypanel Data Ports
RS485 with dedicated transceivers for every port.
Peripheral Data Port
RS485 for GPIO-16/LCP-102
Trunk Port
RS485 for Trunking
PC Port
RS232 for AZedit (supports CPL)
USB Port
USB for AZedit
Ethernet Port
10/100Mbps for remote AZedit
Call Signals:
Balanced:
Receive:
20kHz ±100Hz, 100mVrms
Send:
20kHz ±100Hz, 500mVrms
RTS Channel 1 and Channel 2
Receive:
20kHz ±100Hz, 100mVrms
Send:
20kHz ±200Hz, 350mVrms
ClearCom (Unbalanced) (DC-call)
Receive:
4VDC
Send:
12VDC
Controls
Reset Switch:
Accessible from the front panel; recessed.
Power Requirements
AC Input:
90-264VAC 50/60Hz
Power Consumption
42 Watts (Full Load)
Physical Dimension
1.72” H x 19” W x 15” D (4.37cm H x 48.26cm W x 38.1cm D)
Weight
7.0lbs (3.18kg)
NOTE: It is recommended to mount the Zeus III with a
half inch (1/2”) spacing on the top and bottom of the unit to allow for proper air flow.
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
12 Introduction Zeus III
Indicators and Controls
Status LEDs
When the Zeus III powers on each time, the Status LED, located on the front panel (see Figure 2), cycle through a three (3) color sequence as it verifies the Zeus III is working properly. The LED color cycle starts with Red, goes to Orange, and ends with Green.
Red - System Malfunction
Orange - Boot Load Mode
NOTE: If Switch S1-7 is set to ON (Force Boot Loader Mode, see Table 9 on page 20) and the Zeus III unit is
powered on, the LED stays at the Orange level of the color cycle, indicating you are in boot loader mode.
Green - Normal Operation
Red LED Orange LED Green LED
FIGURE 2. Red LED Status, Orange Status, and Green Status Indicator
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
Zeus III Introduction 13
CH A and CH B 2W/Party Line LEDs and Controls
The CH A and CH B 2W/Party Line LEDs and Controls are used to configure dual-channel party line interface. Ports 33 and 34 in the intercom system are designated as the 2-wire party line channels. For more information on party line operation, see “Party Line Operation” on page 45.
FIGURE 3. CH A and CH B 2W/Party Line LEDs and Controls
Peak LED Indicator
The Peak LED indicator displays if the party line channel or 2-wire channel is operating within the normal operating levels.
When the level is less than -12dBu, the LED is off.
When the level is between -12dBu to 1dBu, the LED is green.
When the level is greater than 1dBu, the LED is red.
2-Wire Mode Rotary Switch
The 2-Wire Mode Rotary Switch is used to select the 2-wire mode you want to configure your party line channel.
Available options are:
OFF - No modes are active
1 - RTS Channel 1 mode
2 - RTS Channel 2 mode
Audiocom (Balanced) - Audiocom Mode
ClearCom (Unbalanced) - ClearCom mode. Unbalanced with DC call
To change the 2-Wire Mode, do the following:
1. Using a flathead screwdriver, insert the head into the rotary switch slot.
2. Turn the flathead screwdriver until the arrow is pointing to the mode you desire.
The corresponding green LED (to the right) lights, designating your selection.
2-Wire Mode LED Indicators
The 2-Wire Mode LED indicators signal which 2-wire mode is currently active. When a mode is active, the green LED next to it lights.
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
14 Introduction Zeus III
Power 1 and Power 2 LED
The Zeus III has two (2) power supplies powered by independent AC feeds. This allows for full power failover protection if one of the power supplies stops working.
Green LEDs located on the front panel (see Figure 4) indicates whether the power supply is working properly or is broken.
When the green LED is lit, the power supply is working properly.
When the green LED is not lit, the power supply is not working properly.
FIGURE 4. Power 1 and Power 2 Status LEDs
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
Zeus III Introduction 15
Connector Pinouts
TABL E 1 . USB Connector Pin Out
Front USB
Standard Type B
Pin Function
1V_BUS
2D -
3D +
4 GND
TABL E 2 . Keypanel Port Connector Pin Out
Rear Keypanel Port
(32) RJ–45(Cat5)
Pin Function
1N/C
2 RS485 Data -
3 Audio Out +
4 Audio In +
5 Audio In -
6 Audio Out -
7 RS485 Data +
8N/C
TABL E 3 . Trunking / To PC Connector Pin Out
Trunking/ To PC Connection
DB–9 Female
TAB L E 4 . Ethernet Connector Pin Out
Ethernet
RJ–45(Cat5)
Pin Function
1TX +
2TX -
3RX +
4-
5-
6RX -
7-
8-
TAB L E 5 . GPIO-16/LCP/PAP Connector Pin Out
Peripheral Data Port
(GPIO-16, LCP-102, Etc.)
DB–9 Female
Pin Function
1 RS485 Data -
2 GND
3N/C
4 GND
5N/C
6 RS485 Data +
7 GND
8N/C
9N/C
Pin Function
1 RS485 Data -
2 RS232 RX
3 RS232 TX
4N/C
5 GND
6 RS485 Data +
7 GND
8N/C
9N/C
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
16 Introduction Zeus III
TAB L E 6 . Relay Connector Pin Out
TABLE 8. GPI Connector Pin Out
Relays
DB–9 Male
Pin Function
1
2
Relay 1:NC
Relay 1:NO
1
1
3 +12V through 300
4
5
6
Relay 2:NC
Relay 2:NO
Relay 1:Common
2
2
1
7GND
8GND
9
1. Relay 1 is also controlled by GPI Output #1
2. Relay 2 is also controlled by GPI Output #2
TAB L E 7 .
Party Line Connector Pin Out
Relay 2:Common
2
Party Line
(2) 3-Pin Female XLR
RTS CH1 RTS CH2
Audiocom (Balanced)
Clear Com
(Unbalanced)
Pin Function Function Function Function
1 Common Common Common Common
2
3
Audio +CALL signal
Audio +CALL signal
CH1 Audio Low +Call
CH1 Audio High +Call
Audio + DC Call
GPI
DB-25 Female
Pin Function
1 GPI Input #1
2 GPI Input #2
3 GPI Input #3
4 GPI Input #4
5 GPI Input #5
6 GPI Input #6
7 GPI Input #7
8 GPI Input #8
9 GND
10 GND
11 GND
12 GND
13 GND
14
15
GPI Output #1
GPI Output #2
1
2
16 GPI Output #3
17 GPI Output #4
18 GPI Output #5
19 GPI Output #6
20 GPI Output #7
21 GPI Output #8
22 GND
23 GND
24 GND
25 GND
1. Control for GPI Output #1 also controls relay 1.
2. Control for GPI Output #2 also controls relay 2.
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
Zeus III Introduction 17
General Purpose Interface (GPI) Connector
The GPI connector provides eight (8) general purpose control outputs. The control inputs can be assigned, using AZedit, to activate intercom ports, party lines, etc. The control outputs can also be assigned, using AZedit, to be activated by keypanel keys. The control outputs can be used to control lighting, to key remote transmitter, to activate a paging system, etc.
Connections
The GPI inputs require +5 to +12VDC for activation. Figure 5 shows a typical connection. The GPI outputs are open collector outputs and require an external voltage to operate. These output pull to common when activated (Figure 6 shows a typical connection). Pin outs for the GPI inputs and outputs are summarized in Table 8.
FIGURE 5. Typical GPI input connection
FIGURE 6. Typical GPI output connection
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
18 Introduction Zeus III
Dip Switches
To access the dip switches in the Zeus III unit, do the following:
1. Using a Phillips head screwdriver, remove the four (4) top screws (see Figure 7).
FIGURE 7. Screw locations on the Zeus III unit
2. Remove the three (3) screws located on the right-side of the unit.
3. Remove the three (3) screws located on the left-side of the unit.
4. Carefully remove the top cover panel and set it to the side.
5. Using Figure 8, locate the dip switch you want to configure.
6. Using Table 9 on page 20 or Table 10 on page 21, configure the dip switch as required.
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
Zeus III Introduction 19
FIGURE 8. Dip Switch Locations
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
20 Introduction Zeus III
S1 Dip Switch
FIGURE 9. S1 Dip Switch
TAB L E 9 . Dip Switch S1 Reference
Dip Switch Description Default Setting
Serial Baud Rate Set
1
Off = 9600 baud On= 38.4k
Authentication Not Required when using USB Connection
2
Off = Authentication not required On = Authentication required when using the USB connection
3 Reserved, Do Not Modify Off
4 Reserved, Do Not Modify Off
5 Reserved, Do Not Modify Off
6 Reserved, Do Not Modify Off
Force Boot Loader Mode
7
Off = normal mode On = force boot loader mode
8 Reserved, Do Not Modify Off
1
Off
Off
Off
1. Make sure the rate set here matches the rate set in AZedit. A 9600 baud permits a longer PC cable, but uploads and downloads are slower (approximately 30 seconds for a complete system update). Alternatively, 38.4 kbaud provides faster uploads and downloads, but the PC cable should be kept to a length less than 10 ft (3m), and some older PC's may not operate reliably at this speed.
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
Zeus III Introduction 21
S2 Dip Switch
FIGURE 10. S2 Dip Switch
TABLE 10. S2 Dip Switch Reference
Dip Switch Description Default Setting
Half duplex on 2-Wire Port 1
1
2
3
4
Off = disable half duplex mode on 2-wire port 1 On = enable half duplex mode on 2-wire port 1
Noise suppression on 2-Wire Port 1 Off = enable noise suppression on 2-wire port 1 On = disable noise suppression on 2-wire port 1
Half duplex on 2-Wire Port 2 Off = disable half duplex mode on 2-wire port 2 On = enable half duplex mode on 2-wire port 2
Noise suppression on 2-Wire Port 2 Off = enable noise suppression on 2-wire port 2 On = disable noise suppression on 2-wire port 2
Off
Off
Off
Off
NOTE: By default, S2 is used to configure the speakerphone IC. However, AZedit cab be used to override the DIP switch
settings.
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
22 Introduction Zeus III
2-Wire Settings in AZedit
The 2-Wire Setting window, shown in Figure 11, is used to override the DIP switch settings you set on the Zues III unit (see “Dip Switches” on page 18) using AZedit.
NOTE: CH-A or CH-B must be selected for the 2-Wire Settings page to be available.
NAVIGATION: On the Keypanel / Ports Window, select the Edit button (see Figure 12).
FIGURE 11. 2-Wire Settings Page
2-Wire Settings Group Box
Use the 2-Wire Settings options to either use the currently set DIP switches, as set in the Zeus III or to override the DIP switch settings for the selected channel. You can set CH-A and CH-B independent from each other, if desired.
Use DIP Switch Settings Radio Button
The Use DIP Switch Settings radio button indicates the currently set DIP switch settings should be used. The current settings are displayed below the radio button.
Manually Override Settings Radio Button
The Manually Override Settings radio button allows the user to select override options to the currently set DIP switch options. Once the Manually Override Settings radio button is selected, the override options check boxes become active below the radio button.
Available override check box options are:
Half Duplex Check Box - Half Duplex operation is enabled.
Full Duplex Check Box - Full Duplex operation is enabled. Audio flows in both directions simultaneously.
Disable Noise Suppression Check Box - Noise suppression is disabled.
Enable Noise Suppression Check Box - Noise suppression is enabled.
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
Zeus III Introduction 23
To configure the 2-wire settings, do the following:
1. From the System menu in AZedit, select Keypanel Assignment.
The Keypanel / Ports window appears.
FIGURE 12. Keypanel / Ports Window
2. From the Alphas drop down list, select CH-A or CH-B.
3. Click Edit.
The Keypanel / Port Configuration Window appears.
4. Click the 2-Wire Settings tab.
The 2-Wire Settings page appears.
5. Make the configuration modifications you desire.
6. Click Apply.
The changes are applied.
7. Click OK.
The Keypanel / Port Configuration window closes.
8. Send Changes to the Intercom.
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
24 Introduction Zeus III
Zeus III and GPIO-16
You can connect a GPIO-16 to the Zeus III intercom system. A GPIO-16 provides 16 GPI (General Purpose Inputs) and 16 GPO (General Purpose Outputs). GPIs can be set up as remotely controlled keypanel keys to activate intercom ports, party lines, GPOs, etc. within the intercom system. GPOs are typically assigned for activation from keypanel keys. They can be used to control lighting or to key remote transmitters, paging systems, etc.
The maximum number of devices that can be connected when using a GPIO-16 are as follows:
Zeus, Zeus II, and ADAM CS = Four (4) devices (64 relays)
ADAM, Zeus III and Cronus = 16 devices (256 relays)
NOTE: In the AZedit GPI Output window, Relays 1 – 8 are dedicated to Zeus III GPI Output. In the AZedit GPI Input
window, GPI Inputs 1 – 8 are dedicated to Zeus III GPI Inputs.For more information on the GPIO-16, see the GPIO User Manual (9350-7842-000).
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
Zeus III Introduction 25
Zeus and Accessory Dimensions
FIGURE 13. Zeus and Accessory Dimensions
NOTE: Front panel rack mounts fit industry standard 19” (483mm) racks and consoles. Dimensions exclude connectors.
Allow at least 2 inches (51mm) for cables and connections.
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
26 Introduction Zeus III
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
CHAPTER 2
Cables
Each Zeus III intercom system has unique requirements for cables, so it is not practical to apply these with the unit. A USB interconnect cable has been provided, but even this may not be long enough for your system layout requirements. Most cables need to be custom built. The following paragraphs and diagrams contain some useful general information for those who are not familiar with cable construction. Connection diagrams are also included for all of the common types of Zeus III connections.
Cable Requirements
We recommend 22AWG, stranded, twisted pair cable for your connections. For most applications, you can use unshielded cable. Shielded cable is only required when some condition in the environment is inducing noise into the intercom system. For keypanels and the TIF, the cables should have three (3) twisted pairs. To connect 4-wire audio devices, you need two (2) twisted pair cables. The LCP-102 and GPIO-16 require a single twisted pair. Ask your intercom dealer about recommended sources for cabling.
Bosch Security Systems, Inc.
Technical Manual
F.01U.193.289
Rev. 05
28 Cables Zeus III
FIGURE 16. Configuration Computer Cable
IMPORTANT: Pins 2 and 3 are switched between the
two (2) connectors.
FIGURE 14. Connector Numbering
FIGURE 15. Cable Requirements
FIGURE 17. Trunking Configuration Cable
FIGURE 18. GPIO-16 Interconnect Cable
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
Zeus III Cables 29
FIGURE 19. GPIO-16/PAP/LCP Interconnect Cable
FIGURE 20. LCP Interconnect Cable
FIGURE 21. RJ-45 Straight Cat-5 and RJ-45 Cat-5
Crossover Cable
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
30 Cables Zeus III
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
Requirements
AZedit version 3.6.2 or later
Default Ethernet IP Addresses
CHAPTER 3
Installation
TABL E 11 . Default Ethernet IP Addresses
Product Default IP Address Default Subnet Mask
RVON-I/O 192.168.0.1 255.255.0.0
RVON-8 192.168.0.2 255.255.0.0
RVON-1 192.168.0.3 255.255.0.0
RVON-C 192.168.0.4 255.255.0.0
RVON-16 192.168.0.5 255.255.0.0
GPIO-16 192.168.0.6 255.255.0.0
MCII-e 192.168.0.7 255.255.0.0
Cronus 192.168.0.8 255.255.0.0
Zeus III 192.168.0.9 255.255.0.0
Bosch Security Systems, Inc.
Technical Manual
F.01U.193.289
Rev. 05
32 Installation Zeus III
Initial Power Up
To power on the Zeus III unit, do the following:
1. Attach the power cord to the power entry module on the rear of the Zeus III.
FIGURE 22. Apply power to the Zeus III.
2. Plug the other end of the power cord into the electrical outlet.
The unit powers on. The Status LED, located on the front panel (see Figure 2 on page 12), cycles through a three (3) color sequence as it verifies the Zeus III is working properly. The LED color cycle starts with Red, goes to Orange, and ends with Green.
NOTE: Repeat step 1 and step 2 for redundant power supplies.
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
Zeus III Installation 33
Zeus III Configuration
There are three (3) configuration types for Zeus III operation:
RS-232 (serial)
USB
Ethernet
NOTE: You can only use one (1) type of communication configuration at a time. For example, if the Zeus III is
connecting to AZedit via USB, it cannot also connect over Ethernet at the same time.
Serial Configuration
To configure the Zeus III for serial configuration, do the following:
1. Attach a serial cable to the Trunk/To PC connector on the rear of the Zeus III.
FIGURE 23. Serial Connector
2. Attach the other end of the serial cable to any available serial connector on the computer with AZedit loaded on it.
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
34 Installation Zeus III
3. In AZedit, from the Options menu, select Communications.
The Communications window appears.
FIGURE 24. Serial Connection – Communications Window
4. Select the Serial radio button.
5. Click OK.
The Zeus III is configured to connect to AZedit serially.
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
Zeus III Installation 35
USB Configuration
IMPORTANT: If you are configuring a USB connection for the first time, you must download the drivers (either 32-bit
or 64-bit) from www.rtsintercoms.com/. The drivers are located under Documents and Downloads in Software - USB 32Bit or USB 64Bit.
Since this is a .zip file,
• extract the AZeditUSB32.exe file to C:\Telex\AZedit\USB on your computer
• run the executable.
To configure the Zeus III for USB configuration, do the following:
1. Attach the supplied USB cable to the USB connector located on the front of the Zeus III.
FIGURE 25. USB Connector
2. Attach the other end of the USB cable to any available USB connector on the computer with AZedit loaded on it.
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
36 Installation Zeus III
3. In AZedit, select Options|Communications.
The Communications window appears.
FIGURE 26. USB Connection – Communication Window
4. Select the USB radio button.
5. Click OK.
The Zeus is configured to connect to AZedit via USB.
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
Zeus III Installation 37
Ethernet Configuration
There are two (2) ways to connect the Zeus III to AZedit over Ethernet:
Using a straight CAT-5 Ethernet cable and connecting to an existing IP Network.
Using a fabricated CAT-5 crossover cable and connecting directly to the AZedit computer. (For the
CAT-5 crossover cable pin out, see Figure 21 on page 29.)
NOTE: The straight CAT-5 cable assembly cannot be directly connected to the computer with AZedit loaded on it. It can
only be used with a router or switch that is connected to the computer. Use the CAT-5 crossover cable to directly connect to the Zeus III with Ethernet.
To configure the Zeus III for Ethernet configuration using the supplied Ethernet cable, do the following:
1. Attach the Ethernet cable to your existing IP network using a network router or switch.
FIGURE 27. Straight Cat-5 Ethernet Connection
2. Attach the other end of the Ethernet cable to the Ethernet connector located on the rear of the Zeus III.
NOTE: By default, Zeus III is shipped with the IP Address 192.68.0.9 and the Network Mask 255.255.0.0.
To change the IP Address, initially you must connect either serially or via USB.
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
38 Installation Zeus III
3. From Options menu, select Communications.
The Communications window appears.
FIGURE 28. Communications Window – Straight Cat-5 Ethernet Cable
4. Select the Network radio button.
5. Click the browse button.
The Available Intercoms window appears.
FIGURE 29. Available Intercoms Window
6. From the Intercoms list field, select the Zeus III intercom you want to connect to.
7. Click OK.
The Available Intercoms window closes and the Communications window appears.
8. Click OK.
The Communications window closes. The Zeus III is configured for Ethernet operation via the supplied cable.
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
Zeus III Installation 39
To configure the Zeus III for Ethernet configuration using the CAT-5 crossover cable, do the following:
By default, Zeus III is shipped with the IP Address 192.168.0.9 and the Network Mask 255.255.255.0. To change the IP Address, you must initially connect either serially or via USB. For crossover cable construction, see Figure 21 on page 29.
NOTE: If access to serial port and USB is not available on the host PC, you must configure your TCP/IP properties on
the PC to match the Zeus III unit subnet (192.168.0.X) for proper communication.
1. Using the CAT-5 crossover cable, attach one end to the Ethernet connector located on the rear of the Zeus III.
FIGURE 30. Crossover Cat-5 Connection
2. Attach the other end of the crossover cable to an Ethernet port on the computer with AZedit loaded.
3. In AZedit, from the Options menu, select Communications.
The Communications window appears.
FIGURE 31. Communications Window – CAT-5 Crossover Cable
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
40 Installation Zeus III
4. Select the Network radio button.
The IP Address group box becomes active.
5. Click OK.
The Communications window closes. The Zeus III is configured for Ethernet operation via the CAT-5 crossover cable.
Initial IP Configuration of the Zeus III
By default, the Zeus III is shipped with the IP Address 192.168.0.9 and the Net Mask 255.255.255.0. to change the IP Address initially, you must connect either serially or via USB.
1. Connect to the PC with AZedit via a serial or USB cable.
2. In AZedit, from the Options menu, select Ethernet Setup.
The Ethernet Setup window appears.
FIGURE 32. Ethernet Setup Window
3. In the IP Address field, enter the IP Address for the Zeus III.
4. In the Netmask field, enter the Netmask Address for the Zeus III, if needed.
5. In the Gateway field, enter the Gateway Address for the Zeus III, if needed.
6. Click Apply.
The IP Address, Network Mask, and Gateway Address are changed.
7. Click Close.
The Ethernet Settings window closes.
NOTE: Remember to send your changes to the Matrix. To send changes to the matrix, from the edit menu, select
Send Changes
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
Zeus III Installation 41
Typical System Installations
2-Wire Channel A and B Configuration
FIGURE 33. 2-Wire Channel A and B Configuration
NOTE: CH A and CH B are not powered by the Zeus III, therefore a power supply must be used for party line channels.
To configure a typical 2-wire channel A and B system, do the following:
NOTE: A TW5W or TW7W breakout panel can be used to connect the 2-wire device, power supply and Zeus III
unit.
1. Connect the Zeus III 2-wire party line channel(s) (CHA and/or CHB) to the breakout panel using a female 3-pin
XLR connector.
2. Connect the 2-wire device to the breakout panel using the specified 3-pin XLR connector.
3. Connect the power supply to the breakout panel using the specified 3-pin XLR connector.
4. Depending on the channel being used by the 2-wire device, set the Zeus III 2-wire mode appropriately.
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
42 Installation Zeus III
Audiocom (Balanced) Mode Configuration for Single Channel System
FIGURE 34. Audiocom (Balanced) Mode Configuration for Single Channel System
NOTE: CH A and CH B are not powered by the Zeus III, therefore a power supply must be used for party line channels.
To configure a typical balanced mode system, do the following:
NOTE: A TW5W or TW7W breakout panel can be used to connect the 2-wire device, power supply and Zeus III
unit.
1. Connect the Zeus III 2-wire party line channel(s) (CHA and/or CHB) to the breakout panel using a female 3-pin
XLR connector.
2. Connect the 2-wire device to the breakout panel using the specified 3-pin XLR connector.
3. Connect the power supply to the breakout panel using the specified 3-pin XLR connector.
4. Using a small, flathead screw driver, set the 2W/Party Line mode to balanced.
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
Zeus III Installation 43
ClearCom (Unbalanced) Mode Configuration
FIGURE 35. ClearCom (Unbalanced) Mode Configuration
NOTE: CH A and CH B are not powered by the Zeus III, therefore a power supply must be used for party line channels.
To configure a typical ClearCom (unbalanced) mode system, do the following:
NOTE: A TW5W or TW7W breakout panel can be used to connect the 2-wire device, power supply and Zeus III
unit.
1. Connect the Zeus III 2-wire party line channel(s) (CHA and/or CHB) to the breakout panel using a female 3-pin
XLR connector.
2. Connect the 2-wire device to the breakout panel using the specified 3-pin XLR connector.
3. Connect the power supply to the breakout panel using the specified 3-pin XLR connector.
4. Using a small, flathead screw driver, set the 2W/Party Line mode to Clear Com (unbalanced).
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
44 Installation Zeus III
Keypanel Configuration
FIGURE 36. Keypanel Configuration
To configure a typical keypanel system, do the following:
> Using an RJ-45 keypanel cable, connect the cable to a keypanel port (ports 1 to 32) located on the back of the Zeus
III unit.
NOTE: For the pin out of the RJ-45 keypanel cable, see Table 2 on page 15.
Trunking Configuration
FIGURE 37. Trunking Configuration
To configure a trunking system, do the following:
1. Connect a serial cable to the TRUNK/TO PC connector located on the rear panel of the Zeus III unit.
2. Connect the other end of the serial cable to the serial cable connector located on the back of the MTM-2000.
3. Use TrunkSupervisor/Editor to configure the Zeus III trunking system (for trunking configuration information,
see the TM-2000/MTM-2000 User Manual – 93507715000).
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
CHAPTER 4
Party Line Introduction and Operation
Party Line Operation
The Zeus III integrates 32 4-wire intercom ports (ports 1 – 32) with two (2) 2-wire intercom ports (ports 33 and 34), allowing audio to pass between the 2-wire channels and 4-wire channels. Any 2-wire system can be connected directly to the Zeus III without an SSA-324 or a DSI-2008, saving the space and expense of supporting two (2) units to convert the signal.
IMPORTANT: Channels must be configured the same between products. For example, a PS-4001 connected to CH1 of
the Zeus III must be set to BAL on both units.
FIGURE 38. Zeus III 4-Wire and 2-Wire Port Allocation
Bosch Security Systems, Inc.
Technical Manual
F.01U.193.289
Rev. 05
46 Party Line Introduction and Operation Zeus III
Party Line Gain Adjustment with Zeus III
Unlike the Zeus III 4-wire channels that can have their input and output gain adjusted, the 2-wire channels (Channel A and Channel B) can only have their input gains adjusted. This is because there is a limit on the amount of gain a 2-wire device can receive (see “Specifications” on page 11), therefore a limiter between the 2-wire device and the Zeus III system limits the amount of gain received by the 2-wire device.
The range for this field is -20dB to +20dB. The default is 0.0dB.
FIGURE 39. Input/Output Gain Window
To adjust the party line input gain, do the following:
1. From the System menu in AZedit, select Gains.
A flyout menu appears.
2. From the flyout menu, select Input/Output Gains.
The Input/Output Gains window appears.
3. Select the party line channel you want to adjust the input value (Port 33 CHA or Port 34 CHB).
NOTE: Notice in Figure 39, the Output Gain column for CHA and CHB has n/a (not available) in the output gain
column.
4. From the Gain drop down menu, select the input gain amount you want to assign to the channel.
OR Using the spinner arrows, adjust the input gain amount up or down.
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
Zeus III Party Line Introduction and Operation 47
5. Click Set Input Gain when you are finished.
The input is adjusted.
Call Signalling
Zeus III party line channels (CH1 and CH2, see Figure 3 on page 13) support an integrated call signalling function controlled through the use of UPL statements in AZedit. Using a UPL statement, you can configure an indicator to activate when calls are received.
NOTE: Call signalling support is only available with AZedit version 3.6.4 and later.
To configure incoming call signalling from a 2-wire system, do the following:
1. In AZedit, from the System menu, select UPL Statements.
The User Programmable Logic Statements window appears.
FIGURE 40. User Programmable Statements Window – AZedit
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
48 Party Line Introduction and Operation Zeus III
2. Double-click a UPL Statement.
The Edit UPL Statement window appears.
FIGURE 41. Edit UPL Statement Window – AZedit
3. In the comment field, enter an identifiable description for the UPL statement.
4. Select the Enabled check box to enable the UPL statement.
FIGURE 42. Naming the UPL Statement
5. From the Input A Type drop down menu, select Call Signal.
A port field and drop down menu appear.
6. In the port field, enter the 2-wire channel port.
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
Zeus III Party Line Introduction and Operation 49
7. From the drop down menu, select the channel the 2-wire system is connected to.
FIGURE 43. Configure the Input Action
8. In the Output Action Type drop down menu, select the output action you want to configure.
9. In the Port field, enter the port number to send the call signal.
10. From the Port drop down menu, select the channel you want to send the call signal.
11. Using the Duration spin box, select the amount of time, in seconds, the call indicator activates (0.1 to 20 seconds).
FIGURE 44. Configure the Output Action
NOTE: In the Description box, to the right of the Output Action group box, you can read a description of the UPL
Statement you just created.
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
50 Party Line Introduction and Operation Zeus III
12. When finished, click Done.
The Edit UPL Statement window closes. The UPL Statement appears in the User Programmable Logic Statement window list.
NOTE: Be sure to send your changes to the intercom system.
To send changes either:
Click the Send icon
From the Online menu, select Send Changes.
NOTE: In most cases, when the input conditions for the UPL statement are true, the output action occurs. Then when the
input condition ceases to be true, the output action terminates. The exceptions are Load File, Force Keys (talk and listen), and Force Headset Transfer. When a UPL statement loads a file, there is no way to “unload” the file when the UPL statement is no longer true. When a talk or listen key is forced ON, or a headset is force ON, with a UPL statement, you must use a second UPL statement to force the keys or headset OFF.
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
CHAPTER 5
Zeus III and VOX
The VOX window, shown in Figure 45, is used to configure Vox on ports in your intercom system. VOX is an audio threshold level you set at the point a channel becomes active. When the threshold is set, a channel does not activate until the preset audio level is attained. This prevents a channel from staying on when no one is around in a high activity area.
NAVIGATION: From the menu bar, select System|Vox.
NOTE: Remember to send any changes you make to the intercom system using Edit|Send Changes or the Activate
button.
FIGURE 45. VOX Window
Bosch Security Systems, Inc.
Technical Manual
F.01U.193.289
Rev. 05
52 Zeus III and VOX Zeus III
Threshold Group Box
Adjust Box
The Adjust box is used to fine tune the VOX threshold level, in dB, for the port after using the Set To slider. Use the adjustment arrows to increase or decrease the VOX threshold level in .5dB increments.
The range for this field is –126dB to 0.0dB.
NOTE: The threshold change is only seen in the Threshold column to the right.
Set To Button and Slider
The Set To button and Slider is used to quickly get to the approximate threshold level, in dB, you want to set for the port. Once you have used the slider, click the Set To button to set the level for the port. Use the Adjust arrows to fine tune the threshold level.
To use the threshold slider, do the following:
1. Click and hold the slider.
2. Drag the slider left to decrease the threshold amount or right to increase the threshold amounts.
Hold Time Group Box
Adjust Box
The Adjust box is used to fine tune the hold time, in seconds, for the port after using the Set To slider. Use the adjustment arrows to increase or decrease the VOX threshold level in .1 second increments.
The range for this field is .02 seconds to 12.5 seconds.
NOTE: The time change is only seen in the Hold Time column to the right.
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
Zeus III Zeus III and VOX 53
Set To Button and Slider
The Set To button and Slider is used to quickly get to the approximate hold time you want to set for the port. Once you have used the slider, click the Set To button to set the time for the port. Use the Adjust arrows to fine tune the hold time.
To use the hold time slider, do the following:
1. Click and hold the slider.
2. Drag the slider left to decrease the hold time amount or right to increase the hold time amount.
Options Group Box
Show Enabled Only Check Box
The Show Enabled Only check box is used to show vox enabled ports only. This feature is used to quickly view ports with vox enabled. If this check box is not selected, all available ports are shown.
Real-Time Changes Check Box
The Real-Time Changes check box is used to make changes to the vox threshold in real time. When selected and in ONLINE mode, vox changes are automatically sent to the intercom system as you make the adjustments.
Port Column
The Port column displays all available ports in the intercom.
Alpha Column
The Alpha column displays the alphas for all the available ports in the intercom.
Supported? Column
The Supported? column displays whether vox is supported on the intercom port. If vox is supported on the port, a green Yes appears in the column. If vox is not supported on the port, a red No appears in the column.
Enabled? Column
The Enabled? column displays whether vox is enabled on the specified port. If vox is enabled on the port, a green Yes appears in the column. If vox is not supported on the port, a red No appears in the column.
To enable vox on the port, do the following:
> Highlight the port or ports you want to enable, and then click Enable Vox.
NOTE: You can also enable vox from the Keypanel/Port Configuration Window.
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
54 Zeus III and VOX Zeus III
Threshold Column
The Threshold column displays the audio level, in dB, at which vox activates on the port.
Hold Time Column
The Hold Time column displays the time, in seconds, the port waits for the presence of audio before turning off.
Audio? Column
The Audio? column indicates if audio is present on the port. If audio is present, a green Yes displays in the column. If there is not audio on the port, a red No appears in the column.
Enable Vox Button
The Enable Vox button is used to enable vox on the selected port or ports. You can also use the Vox page in the Keypanel/Port Configuration window to enable or disable vox on a port.
NOTE: To select more than one port to enable, do one of the following:
To select random ports, press and hold the Ctrl key and click the ports you want to select.
To select a block of ports, click the top-most port in the block; press and hold the Ctrl + Shift; press
the bottom-most port in the block.
All the ports in between the top and bottom port are selected.
Disable Vox Button
The Disable Vox button is used to disable vox on the selected port or ports. You can also use the Vox page in the Keypanel/Port Configuration window to enable or disable vox on a port.
NOTE: To select more than one port to disable, do one of the following:
To select random ports, press and hold the Ctrl key and click the ports you want to select.
To select a block of ports, click the top-most port in the block; press and hold the Ctrl + Shift; press
the bottom-most port in the block.
All the ports in between the top and bottom port are selected.
Reset Threshold Button
The Reset Threshold button is used to return the threshold levels of the selected port or ports to the default level.
The default threshold level is -30.0dB.
NOTE: To select more than one port to reset, do one of the following:
To select random ports, press and hold the Ctrl key and click the ports you want to select.
To select a block of ports, click the top-most port in the block; press and hold the Ctrl + Shift; press
the bottom-most port in the block.
All the ports in between the top and bottom port are selected.
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
Zeus III Zeus III and VOX 55
Reset Hold Time Button
The Reset Hold Time button is used to return the hold time for the selected port or ports to the default time.
The default hold time is 0.5 seconds.
NOTE: To select more than one port to reset, do one of the following:
To select random ports, press and hold the Ctrl key and click the ports you want to select.
To select a block of ports, click the top-most port in the block; press and hold the Ctrl + Shift; press
the bottom-most port in the block. All the ports in between the top and bottom port are selected.
Select All Button
The Select All button highlights all of the items from the Available or Selected list.
De-Select All Button
The De-select All button de-selects any selected items from the Available or Selected list.
Invert Selections Button
The Invert Selections button reverses the selections in the current view. For example, if ports 1 through 5 are highlighted, while ports 6 through 10 are not, when the Invert Selection button is clicked, ports 1 through 5 are deselected and ports 6 through 10 become highlighted.
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
56 Zeus III and VOX Zeus III
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
APPENDIX A
Changing the IP Properties on your PC
IMPORTANT: Before you change any network settings on your computer, please make note of the current settings.
NOTE: The following instructions are for Microsoft XP operating system and may differ slightly for other operating
systems.
To change the IP properties on your PC, do the following:
1. Disable any Ethernet connections on the PC you want to alter the IP Properties for.
2. From the Windows Start menu, select Control Panel.
The Control Panel window appears.
3. Click Network and Internet|Network and Sharing Center.
The Network and Sharing Center window appears.
4. Right-click the Local Area Connection.
Bosch Security Systems, Inc.
Technical Manual
F.01U.193.289
Rev. 05
58 Zeus III
5. Select Properties.
The Local Area Connection Status window appears.
FIGURE 46. Open the Local Area Connection Status Window
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
Zeus III 59
6. Click Properties.
The Local Area Connection Properties window appears.
FIGURE 47. Open the Local Area Connection Properties Window
7. Select Internet Protocol (TCP/IP) from the connection list.
8. Click Properties.
The Internet Protocol (TCP/IP) Properties window appears.
TIP: Remember to note the current settings.
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
60 Zeus III
9. Select the Use the following IP address radio button.
The corresponding IP Address fields become active.
FIGURE 48. Enter the IP Address of the Zeus III.
10. In the IP address field, enter the IP Address you want to configure for the Zeus III, if desired.
11. In the Subnet mask field, enter the Subnet Mask you want to configure the Zeus III, if desired.
12. In the Default gateway field, enter the Gateway Address you want to configure for the Zeus III, if desired.
13. Click OK.
The IP (TCP/IP) Properties window closes.
14. Click OK.
The Local Area Connection Properties window closes and the IP Address has been changed.
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
APPENDIX B
UPL Resource Guide
UPL (User Programmable Language) is a powerful feature which lets you quickly and easily program the intercom system to perform output actions you specify based on input conditions you specify. The UPL Statements window displays information concerning the UPL statements configured for your intercom system.
EXAMPLE:You can program the intercom system to load a new setup file at a specified time or load whenever
someone presses a particular keypanel key. On the other hand, you can program talk and listen path to turn on or off at specified times. Using UPL Statements Setup, you can build the custom operations quickly and easily to get the most out of your intercom system.
Use the Edit UPL Statement window to create your customized UPL statements.
To access the Edit UPL Statements window, do the following:
1. From the Alphas menu, select UPL Statements.
The User programmable Logic Statements window appears.
2. Double-click the UPL Statement you want to create.
The Edit UPL Statement window appears.
Bosch Security Systems, Inc.
Technical Manual
F.01U.193.289
Rev. 05
62 Zeus III
FIGURE 49. Edit UPL Statement Window
UPL Statement Group Box
Comment Field
The Comment field is used to enter a description or comment about the current UPL statement.
This field can contain up to 32 characters.
Enabled Check Box
The Enabled check box indicates the UPL statement is enabled and ready to use. Clear the check box to disable the UPL statement, but not delete it.
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
Zeus III 63
Input A Group Box
Type and Variable Drop Down Menu
The Type and Variable drop down menu is used to select an input condition that causes the intercom system to perform an output action. Each UPL statement can have either one (1) or two (2) input conditions. Depending on which is selected from the Type drop down menu, dictates what variable is needed.
Use Table 12 on page 63 to determine the type and variables you want to use.
TABLE 12. Input A and Variables
Input Condition Input Description Variables Needed
UPL Statement If a specified UPL statement is true... UPL Statement # and Description
GPI Input If a system GPI Input is activated.... GPI Input # and Alpha
GPI Input (Local) If a Local GPI Input is activated...
GPI Output If a system GPI Output is activated... GPI Output # and Alpha
GPI Output (Local) If a Local GPI Output is activated...
Talk Key If a specified Talk Key on a keypanel is ON...
Listen Key If a specified Listen Key on a keypanel is ON...
UPL Resource If a UPL Resource key is activated... UPL Resource # and Description
Crosspoint If a specified Crosspoint is activated...
Input Talking If a specified port is talking to anyone... Input # and Alpha
Output Listening If a specified port is listening to anyone... Output # and Alpha
Headset Transfer
If the Headset Transfer switch on a keypanel is activated...
Port # and Alpha
GPI Input # and Alpha
Port # and Alpha
GPI Output # and Alpha
Port # and Alpha
Key #
Port # and Alpha
Key #
Input # and Alpha
Output # and Alpha
Port # and Alpha
Year, Month, and Day (YY/MM/DD).
Current Date If the Current Date is...
Current Time If the Current Time is...
NOTE: You must use the Operator drop down menu
when using the Date and/or Time input.
Hour, Minute, Second (00:00:00)
All times are entered in the 24-hour or military time format. For example, 1:00 pm is 13:00:00.
NOTE: You must use the Operator drop down menu
when using the Date and/or Time input.
IFB Interrupted If the specified IFB is interrupted... IFB # and Alpha
If the Counter is...
NOTE: Counters count increments of time.
Each counter is equal to 100ms of
Counter
The counter input selection is used to write UPL statements to occur in a timed event. For example, when a key is pushed, wait 10 seconds before running the UPL statement to turn a light ON.
Vox Audio If the Vox Audio is... Input # and Alpha
Any Talk Key If Any Talk Key is on a keypanel is ON.... Port # and Alpha
Call Signal If a call signal is detected.... Port # and Alpha
time. AZedit allows for up to 256 counters to be used.
Counter #
NOTE: You must use the Operator drop down menu
when using the Counter input.
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
64 Zeus III
Invert Input A Check Box
The Invert Input A check box is used to reverse the input condition.
For example, if the input condition is Talk K e y, which by itself means, when a specified talk key is on, run the assigned output. However, by selecting the Invert Input A check box, it means a specified talk key is off, run the assigned output.
The invert check box is often used in one UPL statement to cancel an action caused by some other UPL statement.
Operation Group Box
Operation Drop Down Menu
The Operation drop down menu is used to select the type of operator to use when joining Input A and Input B or when using the Current Date, Current Time, or the Counter input for Input A. In all other cases, the Operation drop down menu is not used.
NOTE: Operators, also known as logical operators, are used to construct more complex searches in a database. They
help make a search more accurate. There are three (3) logical operators: AND, OR and NOT.Operators for Two Input Conditions
Operator Description
AND If input A and input B are both true....then run the specified output.
OR If input A or input B (or both) are true....then run the specified output.
XOR If input A or input B (but not both) are true....then run the specified output.
Operators for Current Date and Current Time
Operator Description
= If the current date or time equals...
! = When the current date or time does not equal...
< When the current date or time is earlier than...
> = When the current date or time is equal to or later than...
> When the current date or time is later than...
< = When the current date or time is equal to or earlier than...
Example: Operators for current time have a 5-second window. For example, if you create a test for a specific time
(i.e., = 12:00:00), the given time is matched for a 5-second window. It returns a true result for the time 12:00:00 through 12:00:05. A test for inequality returns true for all but this 5-second window.
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
Zeus III 65
Input B Group Box
Type and Variable Drop Down Menus
The Type and Va ri ab le drop down menu is used to select an input condition that causes the intercom system to perform an output action. Each UPL statement can have either one (1) or two (2) input conditions. Depending on which is selected from the Type drop down menu. Use Table 13 on page 65 to determine the type and variables you want to use.
TABLE 13. Input B Types and Variables
Input
Condition
UPL Statement If a specified UPL statement is true... UPL Statement # and Description
GPI Input If a system GPI Input is activated.... GPI Input # and Alpha
GPI Input (Local) If a Local GPI Input is activated...
GPI Output If a system GPI Output is activated... GPI Output # and Alpha
GPI Output (Local)
Talk Key If a specified Talk Key on a keypanel is ON...
Listen Key If a specified Listen Key on a keypanel is ON...
UPL Resource If a UPL Resource key is activated... UPL Resource # and Description
Crosspoint If a specified Crosspoint is activated...
Input Talking If a specified port is talking to anyone... Input # and Alpha
Output Listening If a specified port is listening to anyone... Output # and Alpha
Headset Transfer
If a Local GPI Output is activated...
If the Headset Transfer switch on a keypanel is activated...
Input Description Variables Needed
Port # and Alpha
GPI Input # and Alpha
Port # and Alpha
GPI Output # and Alpha
Port # and Alpha
Key #
Port # and Alpha
Key #
Input # and Alpha
Output # and Alpha
Port # and Alpha
Year, Month, and Day (YY/MM/DD).
Target Date If the Target Date is...
NOTE: Target Date is used in conjunction
Hour, Minute, Second (00:00:00)
NOTE: All times are entered in the 24-hour
Target Time Target Time is used in conjunction with Current Time.
NOTE: Target Time is used in conjunction
IFB Interrupted If the specified IFB is interrupted... IFB # and Alpha
Target Value is used in conjunction with the Counter input.
Tar g et Val ue
NOTE: Automatically switches input A to
Counter.
Vox Audio If Vox Audio is... Input # and Alpha
Any Talk Key If Any Talk Key is on a keypanel is ON.... Port # and Alpha
Call Signal If a Call Signal is detected Port # and Alpha
Bosch Security Systems, Inc.
The target value is an increment of time, in ms, to trigger an event. 1 counter equals 100ms.
The counter input selection is used to write UPL statements to occur in a timed event. For example, when a key is pushed, wait 10 seconds before running the UPL statement to turn a light ON.
with Current Date.
or military time format. For example, 1:00 pm is 13:00:00.
with Current Time.
F.01U.193.289
Rev. 05
66 Zeus III
Invert Input B Check Box
The Invert Input B check box is used to reverse the input condition.
For example, if the input condition is “Talk Key”, which by itself means, when a specified talk key is on, run the assigned output. However, by selecting the Invert Input A check box, it means changes to when a specified talk key is off, run the assigned output.
The invert check box is often used in one UPL statement to cancel an action caused by some other UPL statement.
Output Action Group Box
Type and Variable Drop Down Menus
The Type and Var i a b l e drop down menu is used to select an output result that occurs when an input definition is met. Depending on which is selected from the Ty pe drop down menu, dictates what variable is needed.
Use Table 14 on page 66 to determine the type and variables you want to use.
TABLE 14. Output Values
Output Output Description Variables Needed
Close Crosspoint
Inhibit Crosspoint
Assert GPI Output
Inhibit GPI Output
Assert GPI Output (Local) Activate the specified Local GPI Output
Inhibit GPI Output (Local)
Force Talk Key Closure Force the specified talk key ON Port Number, Alpha and Key Number
Force Talk Key Open Force the specified talk key OFF Port Number, Alpha and Key Number
Dim Crosspoint Volume
Load File
Force Listen Key Closure Force the specified listen key ON Port Number, Alpha, and Key Number
Force Listen Key Open Force the specified listen key OFF Port Number, Alphas, and Key Number
Clear Counter Clear the Counter
Inhibit Output Open the output port. Output Port Number, and Alpha
Close the crosspoint from the specified input to the specified output
Open the crosspoint from the specified input to the specified output.
Activate the specified System GPI Output
Deactivate the specified System GPI Output
Deactivate the specified Local GPI Output
Cause the specified output to hear the specified input at a reduced volume level.
Cause a file to be loaded from disk and sent to the intercom system.
NOTE: AZedit must be in SERVER
mode.
Input Number, Alpha, Output Number, Alpha
Input Number, Alpha, Output Number, Alpha
GPI Output Number and Alpha
GPI Output Number and Alpha
Port Number and Alpha, GPI Output Number and Alpha
Port Number and Alpha, GPI Output Number and Alpha
Input Number, Alpha, Output Number, Alpha and DIM amount (-1.0dB to -72.2dB, and Mute)
The Load File pulls files from the directory you have configured on the General page in the Preferences window.
Clears the counter input from the UPL statement. If you select 0 all counters are cleared
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
Zeus III 67
TABLE 14. Output Values
Output Output Description Variables Needed
THIS IS NOT CONFIGURABLE FROM AZEDIT. This option is used by command line
Inform Command Line Protocol
Set Headset Transfer State Set the Headset to the specified state.
Set Talk Key LED State Set the Talk Key LED State
Set Listen Key LED State Set the Listen Key LED State
protocol only. When a query is sent from the command line protocol to AZedit, a UPL statement is written with “Inform Command Line Protocol” as the output. This can be used to monitor the query sent from the command line protocol.
For more information, contact customer service.
Port Number, Alpha, Headset State Headset state selections are:
Turn Headset transfer OFF
Turn Headset transfer ON
Force Headset transfer OFF
Force Headset transfer ON
Release Headset transfer
NOTE: The difference between Turn and
Force is when force is used the user cannot change the headset transfer once the transfer is complete.
Port Number, Alpha, Key, and LED State LED state selections are:
Local Control
Solid Red
Solid Green
Solid Amber
Slow Red Flash
Slow Green Flash
Fast Red Flash
Fast Green Flash
Slow Red Wink
Slow Green Wink
Port Number, Alpha, Key, and LED State LED state selections are:
Local Control
Solid Red
Solid Green
Solid Amber
Slow Red Flash
Slow Green Flash
Fast Red Flash
Fast Green Flash
Slow Red Wink
Slow Green Wink
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
68 Zeus III
TABLE 14. Output Values
Output Output Description Variables Needed
IFB Number, Alpha, Input Port Number, and Alpha
NOTE: If you set the Input Port Number to 0,
you are assigning no input port.
Set IFB Program Input
Set the Program Input Port for an IFB assignment.
Send a signal over a serial connection to a paging system to start a macro.
Start Paging System Macro
NOTE: The macro is stored in the
Macro Number paging system. AZedit sends an event to trigger the macro on the Paging System.
Send a signal over a serial connection to a paging system to end the macro.
Stop Paging System Macro
NOTE: The macro is stored in the
Macro Number paging system. AZedit sends an event to trigger the macro on the Paging System
Generate Call Signal Sends a call signal to the specified port Port #, Alpha, and Signal Duration
Generate Mic Kill Sends a mic kill signal Port #, Alpha, and Signal Duration
NOTE: In most cases, when the input conditions for the UPL statement are true, the output action occurs. Then, when the
input condition ceases to be true, the output action terminates. The exceptions are Load File, Force Keys (talk and listen), and Force Headset Transfer. When a UPL statement loads a file, there is no way to unload the file when the UPL statement is no longer true. When a talk or listen key is forced on, or a headset is force on, with a UPL statement, you must use a second UPL statement to force the keys or headset off.
Description Field
The Description field displays a plain-text description of the UPL statement you build. You can use this description to verify the UPL statement is constructed to run as anticipated.
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
Zeus III 69
Notes
Bosch Security Systems, Inc.
F.01U.193.289
Rev. 05
Bosch Security Systems, Inc.
12000 Portland Avenue South
Burnsville, MN 55337 U.S.A.
www.boschcommunications.com