RTS RT-2M User Manual

RT-2M (90007891000) Quick Start Guide
CONNECTOR CONNECTION
RJ-12
Plug pins 2 and 5 into the Ch 1 input connector terminals.
Plug pins 3 and 4 into the Ch 1 output connector terminals.
DB-9
Plug pins 7 and 8 into the Ch 1 input connector terminals
Plug pins 4 and 5 into the Ch 1output connector terminals.
INCLUDED PARTS:
RT-2M Unit
DB-9 Cable
NOTE: See the entire system diagram on reverse side.

RS-232 Cable Pinout

Step 1. Cable the Trunk Supervisor/TrunkEdit PC to the
RT-2M.
NOTE: In Trunk Supervisor, you must designate
the intercom and port number the RT-2M sends the test signal over.
Step 2. Cable the RT-2M to the Frame.
To cable the RT -2M to the Frame, do the following:
1. Using the appropriate connector defined below, connect the
RT-2M to the Frame:
1. Using the included cable, connect a COM port on
the Trunk Supervisor computer to the RS-232 Interface connector on the rear panel of the RT-2M.
2. Connect the other end of the connector to the trunking
LIT000306000 Rev. A 11/2008
connection port as defined in the Trunk Supervisor software.
Loading...