The product information and design disclosed herein were originated by and are the property of Bosch Security Systems, Inc.
Bosch reserves all patent, proprietary design, manufacturing, reproduction, use and sales rights thereto, and to any article disclosed
therein, except to the extent rights are expressly granted to others.
COPYRIGHT NOTICE
Copyright 2012 by Bosch Security Systems, Inc. All rights
reserved. Reproduction, in whole or in part, without prior written
permission from Bosch is prohibited.
*All other trademarks are property of their respective owners.
WARRANTYAND SERVICE INFORMATION
For warranty and service information, refer to the appropriate web
site below:
Customer Service Department
Bosch Security Systems, Inc.
12000 Portland Avenue South
Burnsville, MN 55337 USA
Telephone: 877-863-4169
Fax: 800-323-0498
Info@rtsintercoms.com
THE LIGHTNING
FLASH AND
ARROWHEAD
WITHIN THE
TRIANGLE IS A
WARNING SIGN
ALERTING YOU OF
“DANGEROUS
VOLTAGE” INSIDE
THE PRODUCT.
SEE MARKING ON BOTTOM/BACK OF PRODUCT.
WARNING: APPARATUS SHALL NOT BE EXPOSED TO DRIPPING OR
SPLASHING AND NO OBJECTS FILLED WITH LIQUIDS, SUCH AS VASES,
SHALL BE PLACED ON THE APPARATUS.
WARNING: THE MAIN POWER PLUG MUST REMAIN READILY OPERABLE.
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, GROUNDING OF
THE CENTER PIN OF THIS PLUG MUST BE MAINTAINED.
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT
EXPOSE THIS APPRATUS TO RAIN OR MOISTURE.
WARNING: TO PREVENT INJURY, THIS APPARATUS MUST BE SECURELY
ATTACHED TO THE FLOOR/WALL/RACK IN ACCORDANCE WITH THE
INSTALLATION INSTRUCTIONS.
CAUTION: TO REDUCE
THE RISK OF ELECTRIC
SHOCK, DO NOT REMOVE
COVER. NO USERSERVICABLE PARTS
INSIDE. REFER
SERVICING TO
QUALIFIED SERVICE
PERSONNEL.
This product is AC only.
THE EXCLAMATION
POINT WITHIN THE
TRIANGLE IS A
WARNING SIGN
ALERTING YOU OF
IMPORTANT
INSTRUCTIONS
ACCOMPANYING
THE PRODUCT.
TECHNICAL QUESTIONS EMEA
Bosch Security Systems Technical Support EMEA
http://www.rtsintercoms.com/contact_main.php
DISCLAIMER
The manufacturer of the equipment described herein makes
no expressed or implied warranty with respect to anything
contained in this manual and shall not be held liable for any
implied warranties of fitness for a particular application or
for any indirect, special, or consequential damages. The
information contained herein is subject to change without
prior notice and shall not be construed as an expressed or
implied commitment on the part of the manufacturer.
Bosch Security Systems, Inc.
User Manual
F.01U.193.264
Rev. 12
TM-2000 & MTM-2000 User Manual iii
Important Safety Instructions
1.Read these instructions.
2.Keep these instructions.
3.Heed all warnings.
4.Follow all instructions.
5.Do not use this apparatus near water.
6.Clean only with dry cloth.
7.Do not block any ventilation openings. Install in accordance with the
manufacturer’s instructions.
8.Do not install near any heat sources such as radiators, heat registers, stoves,
or other apparatus (including amplifiers) that produce heat.
9.Do not defeat the safety purpose of the polarized or grounding-type plug. A
polarized plug has two blades with one wider than the other. A grounding
type plug has two blades and a third grounding prong. The wide blade or the
third prong are provided for your safety. If the provided plug does not fit
into your outlet, consult an electrician for replacement of the obsolete outlet.
10.Protect the power cord from being walked on or pinched particularly at
plugs, convenience receptacles, and the point where they exit from the
apparatus.
11.Only use attachments/accessories specified by the manufacturer.
12.Use only with the cart, stand, tripod, bracket, or table specified by the
manufacturer, or sold with the apparatus. When a cart is used, use caution
when moving the cart/apparatus combination to avoid injury from tip-over.
13.Unplug this apparatus during lightning storms or when unused for long
periods of time.
14.Refer all servicing to qualified service personnel. Servicing is required
when the apparatus has been damaged in any way, such as power-supply
cord or plug is damaged, liquid has been spilled or objects have fallen into
the apparatus, the apparatus has been exposed to rain or moisture, does not
operate normally, or has been dropped.
Bosch Security Systems, Inc.
User Manual
F.01U.193.264
Rev. 12
iv TM-2000 & MTM-2000 User Manual
Bosch Security Systems, Inc.
User Manual
F.01U.193.264
Rev. 12
Table
of
Contents
DESCRIPTION AND SPECIFICATION ................................................................................... 3
Front Panel Features ............................................................................................................................................ 4
Rear Panel Features ............................................................................................................................................. 5
Serial Ports ......................................................................................................................................................... 15
USEFUL LINUX TRICKS ......................................................................................................... 27
Bosch Security Systems, Inc.
User Manual
F.01U.193.264
Rev. 12
2 TM-2000 & MTM-2000 User Manual
Bosch Security Systems, Inc.
User Manual
F.01U.193.264
Rev. 12
CHAPTER 1
Description and Specification
Introduction
This manual describes the installation and operation of the TM-2000/MTM-2000 (Trunk Master and Mini-Trunk Master),
SWP-2000 (Switch-Over Panel), and ICP-2000 (Interconnect Panel).
TM-2000/MTM-2000
The RTS Trunking System manages intercommunications between separate intercom systems using intercom ports reserved
and interconnected between the intercom systems. Keypanels or other data devices communicate with various destinations in
other intercom systems via the reserved intercom ports. (This is different from bus expansion, where the bus system of two (2)
or more frames are interconnected to form one (1) larger system.)
The RTS Trunking System consists of an RTS Model TM-2000/MTM-2000 and one (1) or more ICP-2000s, depending on the
number of intercom systems to be trunked. A backup TM-2000/MTM-2000 may also be added to prevent downtime in the
event of a failure of the main master control unit. When both main and backup control units are used, an SWP-2000 is
required.
Bosch Security Systems, Inc.
User Manual
F.01U.193.264
Rev. 12
4 Description and SpecificationTM-2000 & MTM-2000 User Manual
Front Panel Features
FIGURE 1. TM-2000 front panel features. (Drawing not to scale)
Bosch Security Systems, Inc.
User Manual
F.01U.193.264
Rev. 12
TM-2000 & MTM-2000 User ManualDescription and Specification 5
1.Status indicators for power, hard drive.
2.Front security panel.
3.Cooling fans (2).
4.Front Fan Filter - slide Right to take out, slide Left to replace.
5.Power switch (front).
NOTE: Press and hold the power switch for five (5) seconds to turn off power.
6.System reset switch.
7.Floppy Drive (used only for factory service).
8.CD-ROM drive.
Rear Panel Features
FIGURE 2. TM-2000 rear panel features (Drawing not to scale)
1.Power supply fan
2.Power switch (rear)
3.AC power connector
4.Keyboard and Mouse connectors
USB Connectors
5.
6.Serial (COM1) port connector. See note below
7.Parallel port connectors. See note below.
8.RJ-45 Ethernet connector (not used at this time)
9.Line Out
10. Mic In
11. Line In
12. Monitor VGA
13. Serial (COM2) port connector. See note below.
14. Card slots: containing (a) RS-485 communication card(s) using MDR connector. See note below. (b) Networking
1
connector using RJ-45 connector. See note below.
NOTE: The exact location of cards and connector designations can vary from unit to unit. The diagram provided is for
general feature locations only. Follow the designated labels found on your particular unit(s).
1. Used only for factory service.
Bosch Security Systems, Inc.
User Manual
F.01U.193.264
Rev. 12
6 Description and SpecificationTM-2000 & MTM-2000 User Manual
2
J1J2J3J4J5J6J7J8
ICP-2000
1
ICP-2000 Description
The ICP-2000 is a 1RU (Rack Unit) breakout panel that converts the MDR connection provided from the
TM-2000/MTM-2000 communication card(s) into 9-pin D-Sub connections. Each RS-485 communication card on the
TM-2000/MTM-2000 has eight (8) ports provided on the MDR connector. The ICP-2000 breaks these eight (8) ports into
individual 9-pin D-sub connections. There are two (2) MDR connectors on the ICP-2000. These two (2) connectors allow both
a primary and redundant TM-2000/MTM-2000 to be connected. The connectors are wired in parallel, so it does not matter
which connector the primary TM-2000/MTM-2000 and (if present) the redundant TM-2000/MTM2000 are plugged into. The
ICP-2000’s connectors are labelled from left to right J1, J2, J3,....J8. These correspond from low number to high number or
ports associated with the cable plugged into the ICP-2000. For example, if the cable plugged into the ICP-2000 has ports 1-8
on it, then J1 would be port 1, J2, port 2, up to J8 being port 8. If the cable plugged into an ICP-2000 has ports 9-16 on it, then
J1 would be port 9, J2 port 10, up to J8 being port 16.
IMPORTANT:It is important to note that in systems using VDP panels, port 1 is reserved for connection to the VDP
controller and should not be connected to an ADAM or ADAM-CS.
ICP-2000 Reference View
FIGURE 3. ICP-2000 Reference View
1.9-pin female D-sub connector -Each connector is dedicated to an RS-485 communications port carried on the
2.MDR connectors -These are wired in parallel, so it does not matter which connector is used with a
Bosch Security Systems, Inc.
MDR cable from the TM-2000/MTM-2000.
TM-2000/MTM-2000 even in redundant systems. The MDR cables are included
with the TM-2000/MTM-2000 or with an add-on RS-485 port card for the
TM-2000/MTM-2000.
User Manual
F.01U.193.264
Rev. 12
Loading...
+ 22 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.