R tron SNIDEN30 User Manual

iDEN MINI
Step 2. Type “HELP” in and hit “Enter” key to look up the list of commands.
Step 3.
To execute a command, “Enter” key must be hit. If the command is successful, “OK” is displayed but if not, “ERROR” is displayed. To reset a MCU (Main Control Unit), type “RESET” in.
Command: >>RESET
Examples
1 Frequency Setup
1.1 iDEN 800,
1.1.1 If the bandwidth is 18MHz, >>8B 0
1.1.1.1 If the frequency range is 851.0MHz ~ 869.0MHz, >>8F 0↵
1.1.1.2 If the frequency range is 850.8MHz ~ 868.8MHz (200KHz shift), >>8F 1↵
1.1.1.3 If the frequency range is 850.6MHz ~ 868.6MHz (400KHz shift), >>8F 2↵
User’s Manual -27-
iDEN MINI
1.1.2 Otherwise, the bandwidth is 7MHz >>8B 1
1.1.2.1 If the frequency range is 862.0MHz ~ 869.0MHz,
>>8F 0↵
1.1.2.2 If the frequency range is 861.8MHz ~ 868.8MHz (200KHz shift),
>>8F 1↵
1.1.2.3 If the frequency range is 861.6MHz ~ 868.6MHz (400KHz shift),
>>8F 2↵
1.2 iDEN 900 (5MHz fixed bandwidthBandwidth setup is not necessary),
1.2.1 If the frequency range is 935.0MHz ~ 940.0MHz,
>>9F 0
1.2.2 If the frequency range is 934.8MHz ~ 939.8MHz (200KHz shift),
>>9F 1
1.2.3 If the frequency range is 934.6MHz ~ 939.6MHz (400KHz shift),
>>9F 2
2 Gain Setup
2.1 iDEN 800 9 TX Gain: 80dB, RX Gain 80dB
>>8TG 80 >>8RG 80
2.2 iDEN 900 9 TX Gain: 80dB, RX Gain 80dB
>>9TG 80 >>9RG 80
* Please, turn off the ALC and ASD by the commands “TXALC OFF”, “RXALC OFF”,
and “ASD OFF” before the gain setup. Factory defaults are specified in ALC ON and ASD ON. While the ALC and ASD are on, the gain setup is not available and an Error
may be occurred.
User’s Manual -28-
iDEN MINI
3 ALC (Automatic Level Control) Level Setup: 30dBm
>>TXALC_LEVEL 30 >>TXALC ON
* ALC (Automatic Level Control) maintains the specific TX and RX output power by the
setup parameter. Do not set the ALC value over 30.
4 ASD* (Automatic Shut Down) Setup:
9 Level: 33dBm, Time: 3sec, Count: 10
* If the output power gets higher than “ASD_LEVEL”, the repeater will shut
down for “ASD _TIME” time and then turn on the amp and measure the output power again. If this repeats “ASD_COUNT” times, the repeater will shut down completely.
>>ASD_LEVEL 33 >>ASD_TIME 3 >>ASD_COUNT 10 >>ASD ON
5 Tx HPA On
>>THPA ON
6 Rx HPA On
>>RXALC_LEVEL 30↵ >>RXALC ON
>>RHPA ON
<Specifying of the operating frequencies, bandwidth, and gains>
User’s Manual -29-
iDEN MINI
<Specifying of the ALCs>
<Setting of the ASD parameters>
User’s Manual -30-
iDEN MINI
<The screenshot of the example setting>
<The screenshot of the ALC Operating>
The maximum output power for operating is +30 dBm on both Tx and Rx.
User’s Manual -31-
iDEN MINI
4.3 Downloading of the latest firmware
Step 1. Click the “Send File…” of Transfer menu.
Step 2. Browse the latest firmware file.
User’s Manual -32-
iDEN MINI
Step 3. Select file to send.
Step 4. Send the file on the “Xmodem” protocol.
User’s Manual -33-
iDEN MINI
Step 5. Push the “Send” button.
<The screenshot of the Xmodem file send>
User’s Manual -34-
iDEN MINI
<The screenshot of firmware download completed>
Step 6. Type “VER” and hit the “Enter” key to check the version of firmware.
User’s Manual -35-
iDEN MINI
* Reference
The Operating Bandwidth & Frequencies
Bandwidth Operating Frequency
851~869MHz
iDEN 800
iDEN 900
Downlink
18MHz-bandwidth
Uplink
Downlink
7MHz-bandwidth
Uplink
Downlink
5MHz-bandwidth
Uplink
Operating bandwidth and Frequencies of iDEN
850.8~868.8MHz
850.6~868.6MHz 806~824MHz
805.8~823.8MHz
805.6~823.6MHz 862~869MHz
861.8~868.8MHz
861.6~868.6MHz 817~824MHz
816.8~823.8MHz
816.6~823.6MHz 935~940MHz
934.8~939.8MHz
934.6~939.6MHz 896~901MHz
895.8~900.8MHz
895.6~900.6MHz
User’s Manual -36-
iDEN MINI
5. Troubleshooting
5.1 RF Connection Check
Problem
Either the downlink output power or the uplink output power (=Input Power to the repeater) is too weak.
Solution
Check if the following RF connections are loose:
1. The cable connection from the donor antenna to the donor
antenna port
2. The cable connection from the service antenna port to the
service antenna
5.2 Power Connection
Problem
All LEDs at the bottom are turned off.
Solution
Check if the power cord is connected correctly and the green LED at the bottom is on.
Figure 17. LEDs Off
User’s Manual -37-
iDEN MINI
Figure 18. AC power cord Check
5.3 Red Light on the Alarm LED
Problem
Red light LED turns on the Alarm LED after applying AC power.
Figure 19. Red Light on Alarm LED
User’s Manual -38-
iDEN MINI
* Check points
The red LED can be turned on due to out of range as the following below:
Alarms Lower Upper
Tx Input -70dBm -30dBm
Tx/Rx Output 0dBm 35dBm
Temperature
-10°C 80°C
DC Voltage 20V 30V
DC Current 0A 5A
Solution
If the red light LED is steady in the range of critical values, request a technical support.
User’s Manual -39-
iDEN MINI
6. Glossary
6.1 ALC (Automatic Level Control)
* ALC feature prevents the repeater from exceeding its maximum output power,
by reducing the gain automatically. ALC is used to adjust the gain to an appropriate level for a range of input signal levels.
[Example] [For the repeater with 30dBm Maximum Output power, 80dB Maximum Gain /30dB Gain control range, -> If input signal is -30Bm and ALC is set as 30dBm, the gain will be 60dB to adjust to the level. If input signal is -55dBm, the output power will be 25dBm by the limitation of the maximum gain even though the ALC is set as 30dBm.]
6.2 ASD (Automatic Shutdown)
* Automatic shut down protects the repeater itself from the oscillation or excessive input signal and eliminates any degradation to the network.
There are three parameters, A SD_LEVEL, ASD_TIME and ASD_COUNT.
If the output power gets higher than “AS D _LEVEL”, the repeater will shut down for “ASD_TIME” time and then turn the amp back on and measure the output power again. If this repeats “ASD_COUNT” times, the repeater will shut down compl etely.
[Example] [For the repeater with 30dBm Maximum Output power, 80dB Maximum Gain /30dB Gain control range, Assuming ASD_ LEVEL: 35dBm, ASD_TIME: 3sec, ASD_COUNT: 3
If the output power is 35dBm [ASD_LEVEL] and higher for some reasons, the repeater will have shut down for 3 seconds [ASD_TIME]. If this repeats 3 times [ASD_COUNT], the repeater will shut down completely.]
User’s Manual -40-
iDEN MINI
M E M O
User’s Manual -41-
iDEN MINI
M E M O
User’s Manual -42-
iDEN MINI
User’s Manual -43-
iDEN MINI
iDEN MINI
Copyright © R-tron Inc. 2000-2007
All Rights Reserved
6402 College Boulevard Overland Park, KS 66211
Any reproduction, distribution, or revisio n of any or all portions of this manual is prohibited without written permission from R-tron Inc. The information in this guide is subject to change without any prior notification.
www.r-tron.com
1-888-31R-TRON
User’s Manual -44-
Loading...