RTI KX3 Quick Reference Manual

KX3
3.5” Advanced In-Wall Controller
Quick Reference Guide
The technologically advanced design of the KX3 delivers an enhanced automation experience, delighting the user with
control simplicity, while offering tremendous power behind the scenes. Ensuring that anyone can effortlessly engage
with their surroundings the KX3 offers a completely customizable 3.5-inch color LCD, ve hard buttons, video intercom
and room status LED’s. However, the KX3 is not just a pretty interface, it is a unique hybrid device that combines the
capabilities of both a touchscreen controller and an advanced control processor in one cost-effective unit.
Featuring:
• May be utilized as an all-in-one, standalone automation solution for control over electronic systems or integrated as an in­wall touchpanel in a larger RTI control system using optional processors and modules.
• Vivid 3.5” WVGA (480x800) color LCD, ve hard buttons and room status LED’s are completely customizable for the ultimate
in simple, intuitive control.
• Built-in control processor provides advanced capabilities including direct control of devices via IR, IP and RS-232, six sense ports, four relays and an astronomical clock for time-based events.
• Proximity sensor wakes up the unit as a user approaches, and an ambient light sensor adjusts the backlighting.
• Integrated 10/100 Base-T (with PoE) and 802.11b/g/n wireless Ethernet for viewing video from network security cameras,
enhanced two-way feedback and remote programming updates.
• Camera, microphone and a speaker enable video intercom capability.
• Built-in 2.4 GHz ZigBee® antenna offers connectivity with RTI wireless remotes.
• Powered using power supply, CB8 connecting block or PoE (Power over Ethernet).
• Stylish low-prole faceplate available in white, black or brushed aluminum (ships with white).
It’s Under Control
DOCUMENT NO.
REV
ECO
REVISION RECORD
DESCRIPTION
DRFT
DATE
01 ----- 11/20/14 PRELIMINARY RELEASE DRF
RESET
ETHERNET
EXPANSION
PORT 1 PORT 2 PORT 3
PORT 4
PORT 5
PORT 6
+
+ +
+ +
+
USB
RTI COM
RS-232
POWER / IR
+12VDC TRIGGER
+3-24VDC SENSE
RELAYS (+30VDC, 5A MAX)
IR OUTPUT LEVEL
1 2
Model XP-6 Advanced Control Processor
N27917
Touchscreen Control Panel
®
MOUNTING
The KX3 is designed for ush-mount installations in walls or cabinets.
Mounting Depth: 1.1in (27.9mm), with mounting wings 1.624in(41.2mm) - plus cabling. Mounting Height: The recommended mounting height for the KX3 is between 54 inches
(1.37m) and 60 inches (1.52m) from the bottom of the faceplate. Mounting Wings: Two mounting wings which can be used to secure the KX3 to drywall
in retrot installations. Use the included “Drywall Cutout Template” to mark the Place KX3 in the wall opening and tighten the mounting wing screws located on the front of the unit (bezel removed).
Conduit Box: For new construction a conduit box may be purchased separately from an RTI distributor. Refer to the conduit box installation guide for mounting instructions.
KX3 POWER OPTIONS
CB-8 Connecting Block: Wire a Cat-5 cable from the KX3 Control Port to the CB-8
Connecting Block (see diagram).
Ethernet Port (Power over Ethernet): Wire a Cat-5 cable from the KX3 Ethernet Port
to an 802.3af compliant Power-over-Ethernet switch (Class #3). NOTE: Using a non- compliant PoE device may damage the KX3.
Power Supply: Connect a power supply (+12VDC to +16VDC, .5A ) to the
“+12-16VDC” and “Ground” terminals of the phoenix connector (see diagram).
IMPORTANT NOTES:
• The KX3 should NOT be powered directly from an RTI control processor.
• Read the Power/Relay/Sense Connection section (right) for wiring information.
KX3 (Rear)
POWER
2A @ 30VDC MAX (60 W MAX)
+12-16 VDC
GND
1 2 3
SENSE INPUTSRELAYS
VOLTAGE / CLOSURE
A B4A B 1 2 3 4 5 6A B A B
DIMENSIONS
1.624” (41.2mm)
1.265” (32.1mm)
KX3 REFERENCE
USB Port
Mounting Holes (4)
1.100” (27.9mm)
Reset Button
4.352” (110.5mm)
2.942” (74.7mm)
(CUT OUT)
POWER
2A @ 30VDC MAX (60 W MAX)
1 2 3
+12-16 VDC
GND
KX3 Advanced
In-Wall Controller
Touchscreen
A B4A B 1 2 3 4 5 6A B A B
www.rticorp.com
SENSE INPUTSRELAYS
VOLTAGE / CLOSURE
5.192” (131.8mm)
(CUT OUT)
5.876” (149.25mm)
Mounting Wings (2)
Room Status
LEDs (2)
Camera
Power Supply
Control Port
(Cat-5 Cable/
RJ-45 Jack)
Pin 8
Ground
Pin 7
Ground
Pin 6
Infrared
Infrared
RS-485-
RS-485+
CB-8 Connecting Block
Pin 5
Pin 4
Pin 3
Pin 2
Pin 1
+9 to +16 VDC
+9 to +16 VDC
XP-6 Control Processor
Ethernet
(Cat-5 cable)
Ethernet Network
Router or Switch
Proximity and Ambient
Programmable Hard Buttons (5)
Mounting Wing Screws (2)
Light Sensor
Microphone
KX3 (Front - Bezel Removed)
CONTROL PANEL
The KX3 has settings that can be adjusted directly through the control panel. Please note that changes made directly in the KX3 control panel will be overwritten by changes made in Integration Designer.
ACCESSING THE CONTROL PANEL
The Control Panel page can be displayed by pressing and holding down the button located in the lower left corner of the KX3, while applying power or resetting the KX3. You can also
assign a “Control Panel” page link to a button in the Integration Designer programming.
ADJUSTABLE SETTINGS
• Backlight Level • Time Out • Sound • Proximity Sensor • Network Information
HARD BUTTON KEYCAP REPLACEMENT
The KX3 hard button keycaps are compatible with the RTI Laser Shark custom button etching service. Find details regarding Laser Shark on the rticorp.com dealer section.
REMOVING KEYCAPS
1. Remove the KX3 bezel.
2. Using a ngernail or small
screwdriver, gently pry up on the bottom edge of the keycap.
INSTALLING KEYCAPS
1. Align the keycap directly over the button location.
2. Gently press straight down on the keycap until it is
seated ush with the display.
KX3 Button
KX3 (Front)
Pry up here to remove.
KX3
POWER
GND
+12-16 VDC
SENSE INPUTSRELAYS
1 2 3
2A @ 30VDC MAX (60 W MAX)
VOLTAGE / CLOSURE
A B
4
A B 1 2 3 4 5 6A B A B
N27917
KX3 Advanced
In-Wall Controller
www.rticorp.com
POWER
GND
+12-16 VDC
SENSE INPUTSRELAYS
1 2 3
2A @ 30VDC MAX (60 W MAX)
VOLTAGE / CLOSURE
A B
4
A B 1 2 3 4 5 6A B A B
DOCUMENT NO.
REV
ECO
REVISION RECORD
DESCRIPTION
DRFT
DATE
01 ----- 11/20/14 PRELIMINARY RELEASE DRF
DOCUMENT NO.
REV
ECO
REVISION RECORD
DESCRIPTION
DRFT
DATE
01 ----- 11/20/14 PRELIMINARY RELEASE DRF
DOCUMENT NO.
REV
ECO
REVISION RECORD
DESCRIPTION
DRFT
DATE
01 ----- 11/20/14 PRELIMINARY RELEASE DRF
DOCUMENT NO.
REV
ECO
REVISION RECORD
DESCRIPTION
DRFT
DATE
01 ----- 11/20/14 PRELIMINARY RELEASE DRF
3.5” Advanced In-Wall Controller
WIRING POWER/RELAY/SENSE INPUT CONNECTIONS
IMPORTANT NOTE: While making these connections, the
phoenix connector must be unplugged in order to reach the screws that are used to secure the wiring in the terminal. During the wiring process, place the phoenix connector into the
“Wire Staging” location (see Step 1). After all of the wiring is connected, nish installing the phoenix connector by aligning it
with the Power/Sense/Relay port and pushing it into place (see Step 2).
Phoenix Connector
Temporarily Plugged Into
“Wire Staging” Location
Power/Sense/Relay Port
SENSE INPUTS
These inputs are capable of sensing contact closure or a voltage trigger (2-24VDC). The sense
input mode can be congured within Integration Designer
or a voltage trigger, events such as IR commands, macros, relay closure, can be executed automatically.
Wiring for contact closure sense: Connect one of the wires from the device to one of the
sense inputs (labeled 1-6) and the other wire to the KX3 ground input.
Wiring for voltage trigger sense: Connect the positive (+) wire from voltage source to one
of the sense inputs (labeled 1-6) and the negative (-) wire to the KX3 ground input.
®
. Upon sensing contact closure
RELAYS
Contact Closure Control
The KX3 relays provide contact closure or switching control for loads up to 2A/30VDC (60W max)
each. Relays are “Normally Open” when not energized, but they can be programmed to behave “Normally Closed” as long as power is applied to the KX3.
Wiring For Contact Closure Control:
1. Connect one of the equipment leads to Contact A of a KX3 relay (labeled 1-4)
2. Connect the remaining equipment lead to Contact B of the same relay.
Voltage Trigger Control
The KX3 relays can also be used as a voltage trigger which requires additional wiring (see
diagram).
IMPORTANT NOTE: When using a relay as a voltage trigger, the KX3 MUST be powered via a CB8 connecting block or a power supply. The voltage trigger will not work when PoE is used.
Wiring For Voltage Trigger Control:
1. Connect the ground terminal (GND) of the KX3 to the ground connection on the equipment to
be triggered.
2. Install a jumper wire (#22 AWG) between the KX3 +12-16VDC terminal and the Contact A
terminal of the relay that is being used to send the voltage trigger.
3. Connect the Contact B terminal of the relay to the +12VDC input on the equipment being
triggered.
Step 1
POWER
SENSE INPUTSRELAYS
2A @ 30VDC MAX (60 W MAX)
VOLTAGE / CLOSURE
1 2 3
+12-16 VDC
4
GND
A B
A B 1 2 3 4 5 6A B A B
Voltage Sense Wiring
Voltage Source Ground (-) Wire
Voltage Source +2-24VDC Wire
Contact Closure Wiring
To Equipment
+12VDC Voltage Trigger Wiring
To Equipment Ground
To Equipment +12VDC Input
Phoenix Connector
Installed
POWER
POWER
POWER
+12-16 VDC
GND
+12-16 VDC
GND
+12-16 VDC
GND
Step 2
2A @ 30VDC MAX (60 W MAX)
1 2 3
A B4A B 1 2 3 4 5 6A B A B
2A @ 30VDC MAX (60 W MAX)
1 2 3
A B4A B 1 2 3 4 5 6A B A B
2A @ 30VDC MAX (60 W MAX)
1 2 3
A B4A B 1 2 3 4 5 6A B A B
POWER
+12-16 VDC
2A @ 30VDC MAX (60 W MAX)
1 2 3
GND
SENSE INPUTSRELAYS
VOLTAGE / CLOSURE
4
A B
A B 1 2 3 4 5 6A B A B
SENSE INPUTSRELAYS
VOLTAGE / CLOSURE
SENSE INPUTSRELAYS
VOLTAGE / CLOSURE
SENSE INPUTSRELAYS
VOLTAGE / CLOSURE
RS-232
The KX3 is capable of two-way RS-232 communication with supported electronics via standard Cat-5 cable with RJ-45 termination (568B). Two RJ-45 to DB-9 adapters are included.
NOTE: RS-232 communication cabling should be limited to 50 feet (16m). The actual distance varies
depending on baud rate.
RJ-45
Pin Signal Signal Name Description
1 DSR Data Set Ready 2 DCD Carrier Detect 3 DTR Data Terminal Ready 4 GND Ground/Common 5 RXD Receive Data 6 TXD Transmit Data 7 CTS Clear To Send
8 RTS Request To Send
DB9-RJ45 ADAPTOR PINOUT
DB-9
Pin Signal Signal Name Description
1 DCD Carrier Detect 2 RXD Receive Data 3 TXD Transmit Data 4 DTR Data Terminal Ready 5 GND Ground 6 DSR Data Set Ready
7 RTS Request To Send
8 CTS Clear To Send 9 NC Not Connected
CONTROL PORT
The Control Port on the KX3 uses a Cat-5 cable with RJ-45 termination. When used in conjunction with an RTI control processor (e.g. RTI XP-6) and an RTI connecting block (e.g. RTI CB-8), this port serves as the power source for the KX3 in addition to infrared and RS-485 communication.
See “Power Options” diagram at left for pinout.
RJ-45 - DB9
Adapter
To RS-232 Controlled
To RTI CB-8 Connecting Block,
(If using PoE for Power: 802.3af Compliant PoE Device (Class #3)
Equipment
RTI Control Processor or IR
Connecting Block
To Ethernet Network Router or Switch
Cat-5
POWER
+12-16 VDC
GND
2A @ 30VDC MAX (60 W MAX)
1 2 3
A B4A B 1 2 3 4 5 6A B A B
SENSE INPUTSRELAYS
VOLTAGE / CLOSURE
ETHERNET PORT
This RJ-45 port allows connection to a 10/100 Base-T Ethernet network (LAN). The KX3 also has integrated wireless Ethernet capability if a hard-wired connection is not possible. Network settings such as the IP address are congurable within Integration Designer. The Ethernet (LAN) connection enables communication with an RTI control system, direct control of devices via IP, MJPEG video, intercom, RTiPanel support and power-over-Ethernet (PoE). When powering the KX3 using PoE, a 802.3af Compliant class 3 PoE switch must be used.
NET LINK LED: The Net Link LED located above the Ethernet port will illuminate if the KX3 is connected to an Ethernet network. The LED will ash intermittently dependent upon trafc.
PROGRAMMING
THE TOUCHSCREEN DISPLAY
The KX3 touchscreen display is programmed using the RTI Integration Designer Programming Software (available to authorized RTI dealers only - rticorp.com).
UPDATING FIRMWARE
It is highly recommended that this and all RTI products have the latest rmware installed. The rmware can be found in the Dealer section of the RTI website (www.rticorp.com). Install the rmware using a USB cable (USB A to Mini B) via the USB port located on the front of the KX3 (bezel removed).
UPDATING SOFTWARE
Integration Designer data les can be downloaded to the KX3 using a USB cable (USB A to Mini B) or via Ethernet (hard-wired or wireless). If the KX3 is hard-wired to a LAN and the router has DHCP enabled, the initial data le can be made over Ethernet.
ZIGBEE WIRELESS SETUP
The KX3 has an integrated Zigbee installation guide on the RTI dealer website for installation instructions and best practices.
®
transceiver module. The connection supports full duplex two-way communication for use with compatible RTI handheld controllers. Refer to the Zigbee
It’s Under Control
®
Product Contents
One (1) KX3 In-Wall Touchpanel Keypad
One (1) Bezel (White)
Four (4) Mounting Wings (two preinstalled)
Two (2) RJ45 to DB9 Serial Adapters
One (1) MAC Address Card
One (1) Drywall Cutout Template
One (1) Quick Reference Guide
Safety Suggestions
Read and Follow Instructions. Read all safety and operating instructions before
operating the unit. Retain Instructions. Keep the safety and operating instructions for future reference. Heed Warnings. Adhere to all warnings on the unit and in the operating instructions. Heat. Keep the unit away from heat sources such as radiators, heat registers,
stoves, etc., including ampliers that produce heat.
Power Sources. Connect the unit only to a power supply of the type described in the operating instructions, or as marked on the unit. Power Cord Protection. Route power supply cords so that they are not likely to be walked on or pinched by items placed on or against them, paying particular attention to the cord plugs at power receptacles and at the point at which they exit from the unit. Water and Moisture. Do not use the unit near water—for example, near a sink, in a wet basement, near a swimming pool, near an open window, etc.
Object and Liquid Entry. Do not allow objects to fall or liquids to be spilled into
the enclosure through openings. Servicing. Do not attempt any service beyond that described in the operating
instructions. Refer all other service needs to qualied service personnel. Damage Requiring Service. The unit should be serviced by qualied service
personnel when:
The power supply cord or the plug has been damaged.
Objects have fallen or liquid has been spilled into the unit.
The unit has been exposed to rain. The unit does not appear to operate normally or exhibits a marked change in
performance.
The unit has been dropped or the enclosure has been damaged.
Cleaning
To clean your KX3, lightly dampen a lint-free cloth with plain water or a mild detergent and wipe the touchscreen, keypad and outer surfaces.
NOTE: Do not use harsh chemicals as damage to the unit may occur.
Contacting RTI
For news about the latest updates, new product information, and new accessories, please visit our web site at:
www.rticorp.com
For general information, you can contact RTI at:
Remote Technologies Incorporated 5775 12th Ave. E Suite 180 Shakopee, MN 55379 Tel. (952) 253-3100 Fax (952) 253-3131 info@rticorp.com
Service & Support
If you are encountering any problems or have a question about your RTI product, please
contact RTI Technical Support for assistance (see the Contacting RTI section of this guide for contact details).
RTI provides technical support by telephone or e-mail. For the highest quality service, please
have the following information ready:
• Your Name
• Company Name
• Telephone Number
• E-mail Address
• Product model and serial number (if applicable)
If you are having a problem with hardware, please note the equipment in your system, a
description of the problem, and any troubleshooting you have already tried.
*Please do not return products to RTI without return authorization.*
Limited Warranty
RTI warrants its products for a period of three (3) years; or for a period of time compliant with local laws when applicable from the date of purchase from RTI or an authorized RTI dealer.
This warranty may be enforced by the original purchaser and subsequent owners
during the warranty period, so long as the original dated sales receipt or other proof of
warranty coverage is presented when warranty service is required. Except as specied below, this warranty covers all defects in material and workmanship
in this product. The following are not covered by the warranty. Damage resulting from:
1. Accident, misuse, abuse, or neglect.
2. Failure to follow instructions contained in this Guide.
3. Repair or attempted repair by anyone other than Remote Technologies Incorporated.
4. Failure to perform recommended periodic maintenance.
5. Causes other than product defects, including lack of skill, competence or experience of user.
6. Shipment of this product (claims must be made to the carrier).
7. Being altered or which the serial number has been defaced, modied or removed.
Federal Communications Commission Notice
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. Any changes or modications not expressly approved by the party responsible for compliance could void the user’s authority to operate the device. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and the receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received including interference that may cause undesired operation.
Industry Canada Compliance Statement
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received including interference that may cause undesired operation. Cet appareil est conforme avec Industrie Canada exempts de licence standard RSS (s). Son fonctionnement est soumis aux deux conditions suivantes:
1. Ce dispositif ne peut causer des interférences nuisibles.
2. Cet appareil doit accepter toute interférence reçue y compris des interférences qui peuvent provoquer un fonctionnement indésirable.
Contains FCC ID: MMURTI2000 Contains FCC ID: MMURTI2100 Contains IC (Canada): 3166A-RTI2000 Contains IC (Canada): 3166A-RTI2100
DECLARATION OF CONFORMITY (DOC)
The Declaration of Conformity for this product can be found on the RTI website at: www.rticorp.com/declaration
Copyright © 2017 • Remote Technologies Incorporated • All rights reserved. 70-210145-20 V1.2