RS PRO IM-191 Instruction Manual

Instruction Manual
IM-191
Magnetic Field Meter
Magnetic Field Meter/
English
2016-7-5/ V001 EN-1
Contents
Introduction EN‐2
Features EN‐2
GeneralSpecification EN‐2
InstrumentDescription EN3
Safety EN‐3
Operation EN‐4
BatteryReplacement EN‐5
LimitedWarranty EN‐6
Contactinformation EN‐7
Magnetic Field Meter/ English
EN-2 2016-7-5 V001
Introduction:
IM-191 is measuring electromagnetic fields of extremely low frequency (ELF) of 30 to 300Hz. It’s capable of measuring the electromagnetic field radiation intensity t that is produced by electric transmission equipment, power lines, microwave ovens, air conditioners, refrigerators, computer monitors, video/audio devices, etc.
Features:
Display micro-Tesla & milli-Gauss in the same tester. Over load indication. Low battery Indication. Data hold and maximum hold function
.
General specification:
Display: LCD display with maximum
reading of 1999.
Sampling Rate: 2.5 times per second. Sensor: Single axis. Frequency response: 30Hz to 300Hz. Measuring Range: 200/2000 mG, 20/200µ
T
.
Accuracy: ±(2.5%±6dgt) at 50Hz/60Hz. Power Supply: 9V NEDA 1604, IEC 6F22,
JIS 006 P. battery x 1pc.
Battery life: About 100 hours Dimension: (LxWXH): 130mm x 55mm x 38mm. Weight: Approx. 160g with battery Accessories: Manual, 9V battery and carrying
bag.
Magnetic Field Meter/
English
2016-7-5/ V001 EN-3
Instrument description:
1. Sensor.
2. LCD
3. Power on/off.
4. maximum hold button
5. Data hole button
6. mG unit select button
7. µT unit select button
8. Range select button
9. Battery cover.
Safety:
CAUTION
Be extremely careful for the following conditions while measuring.
Do not operate the meter in the environment with
explosive gas (material), combustible gas (material) steam or filled with dust.
In order to avoid reading incorrect data, please replace
the battery immediately when the symbol
appears
on the LCD.
In order to avoid the damage caused by contamination or
static electricity, do not touch the circuit board before you take any adequate action.
Operating Environment is for indoors use only. The meter
was designed for being used in an environment of pollution degree 2.
Operation Altitude: Up to 2000M. Operating Temperature & Humidity: 5°C ~ 40°C, 0%~
80%RH.
Storage Temperature & Humidity: -10°C ~ 60°C, 0%~
70%RH.
Magnetic Field Meter/ English
EN-4 2016-7-5 V001
Operation:
1. Press to turn the power on or off.
2. Turn the meter
on, press or to select the unit of
mG(Gauss)
or μT(Tesla).
3. Position the front (see Figure 1) of the meter to measure the electromagnetic waves. Change the measurement angle or position to obtain the highest reading value (see Figure 2 through Figure 6).
4. The LCD displays the measured value.
Arrow pointing direction indicates the direction of electromagnetic waves.
NOTE: Due to the normal environmental magnetic field,
the meter may display a reading that is lower than
0.5mG prior to measuring. This is not a malfunction of the device.
5. After the testing, turn the power off.
Magnetic Field Meter/
English
2016-7-5/ V001 EN-5
Range
The LCD displays “OL” on the left highest position indicates overload reading. Press to select a higher range and repeat the measurement.
MAX
To retain the maximum value, press and the reading value displayed on the LCD will keep updating to the maximum value.
Data Hold
Freezes the reading present on the LCD at the moment when is pressed. Press again to disable data hold.
Battery Replacement:
The meter is powered by 9V battery x 1pc. Use the following procedure to replace the battery:
1. Replace battery immediately when the LCD displays .
2. Turn the meter off and remove the battery cover.
3. Replace with the new battery; take care to note the correct polarity.
4. Re-install the battery cover.
Magnetic Field Meter/ English
EN-6 2016-7-5 V001
Limited Warranty:
This meter is warranted to the original purchaser against defects in material and workmanship for 3 year from the date of purchase. During this warranty period, RS Components will, at its option, replace or repair the defective unit, subject to verification of the defect or malfunction. This warranty does not cover fuses, disposable batteries, or damage from abuse, neglect, accident, unauthorized repair, alteration, contamination, or abnormal conditions of operation or handling. Any implied warranties arising out of the sale of this product, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the above. RS Components shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expense or economic loss. Some states or countries laws vary, so the above limitations or exclusions may not apply to you. For full terms and conditions, refer to the RS website.
Magnetic Field Meter/
English
2016-7-5/ V001 EN-7
Contact information:
Africa
RS Components SA
P.O. Box 12182,
Vorna Valley, 1686
20 Indianapolis Street, Kyalami Business Park, Kyalami, Midrand South Africa
www.rs-components.com
Asia
RS Components Pte Ltd.
31 Tech Park Crescent Singapore 638040
www.rs-components.com
China
RS Components Ltd.
Suite 23 A-C East Sea Business Centre Phase 2 No. 618 Yan'an Eastern Road Shanghai, 200001 China
www.rs-components.com
Europe
RS Components Ltd.
PO Box 99, Corby, Northants. NN17 9RS United Kingdom
www.rs-components.com
Japan
RS Components Ltd.
West Tower (12th Floor), Yokohama Business Park, 134 Godocho, Hodogaya, Yokohama, Kanagawa 240-0005 Japan
www.rs-components.com
U.S.A
Allied Electronics
7151 Jack Newell Blvd. S. Fort Worth, Texas 76118 U.S.A.
www.alliedelec.com
South America
RS Componentes Limitada
Av. Pdte. Eduardo Frei M. 6001-71 Centro Empresas El Cortijo Conchali, Santiago, Chile
www.rs-components.com
Loading...