RS PRO ICM A6N Instruction Manual

Instruction Manual ICM A6N Clamp Meter
EN DE ES IT FR
1000Vdc
750Vac
600V
EN - 2
Safety Information
Read and understand this Instruction Manual completely before using this instrument. Failure to observe the warnings and cautions in this Instruction Manual may result in injury or death, or damage to the instrument and other equipment or property. If this instrument is used in a manner not specified in these instructions, the protec­tion provided by the instrument may be impaired.
The following symbols may appear on the instrument and in this Instruction Manual:
Risk of electric shock
Refer to Instruction Manual
Alternating Current (ac)
<
Battery
Earth
Equipment protected throughout by double or reinforced insulation
Conforms to EU directives
Dispose of this equipment in accordance with local regulations.
E
Application around and removal from hazardous Live conductors is permitted.
WARNING
- Examine the instrument and probes and
leads before use. Do not use the instru­ ment if it is wet or damaged, or if you suspect it is not operating correctly.
- When using the instrument, test leads or probes, keep your fingers behind the finger guards.
- Remove the test lead from the instrument before opening the battery cover or instru­ ment case.
- Always use the correct terminals, switch position and range for measurements.
EN - 3
- Verify the instrument is operating correctly by measuring a known voltage before use. If in doubt, have the instrument serviced.
- Do not apply more than the rated voltage as marked on the instrument between terminals, or between any terminal and earth ground.
- Use caution when measuring voltages above 30 Vac rms or 60 Vdc. These voltages pose a shock hazard.
- To avoid incorrect readings that can lead to electric shock, replace the battery as soon as low battery indicator < appears in the display.
- Disconnect the circuit power and discharge all high-voltage capacitors before making resistance, continuity, or diode measurements.
- Do not use the instrument in a Hazardous Area or around explosive gasses or vapours.
- Wear suitable Personal Protective Equipment when working around or near hazardous Live conductors which could be accessible.
Caution
- Disconnect the test leads from the test
points before changing the position of the function rotary switch.
- Never connect the instrument to a source of voltage with the function rotary switch in Ω/ ;/ A position.
- If possible, do not work alone, so assistance can be given if required.
- Do not expose the instrument to extremes of temperature or high humidity.
EN - 4
Maintenance
Do not attempt to repair this Instrument. It contains no user-serviceable parts. Repair or servicing should only be performed by qualified personnel. This instrument should be calibrated yearly, or more frequently if used in harsh conditions or if it is suspected of being inaccurate. For calibration and repair contact RS Components - the address is given at the end of these instructions.
Cleaning
Periodically wipe the case with a damp cloth and detergent. Do not use abrasives or solvents.
EN - 5
Power On / Off
When first turned on, the instrument displays the remaining capacity of the battery. Replace the battery when 0% is shown or the low battery symbol “< remains visible in the display. After a successful battery self-test, the instrument will automatically select resis­ tance (Ω)/continuity mode.
Auto Hold Enable / Disable
Auto Power Off Enable / Disable
EN - 6
Self-Testing Aid
Fail of usage
Ready to use
CAT..600V with respect to earth for the jaw.
Barrier for Hand Guard
Do not hold the meter above the Barrier
Do not attempt to measure while power-
ing up, as it will cause the self-test to fail.
Caution
If “FAIL” is shown in the display, do not use the instrument as an internal fault has occurred.
AC Current measurement
EN - 7
AC V / DC V
Caution
When connecting the test leads to the circuit or device, connect the black lead before the red lead. When removing the test leads, remove the red lead before the black lead.
Input Impedance
Note : The input impedance is4K for an
input voltage up to 30V and increases automatically with input voltage to approxi­mately 375KΩ at 750V.
EN - 8
Continuity
Resistance / Diode
EN - 9
Priority of function
The LCD display shows volt­age mode, when the voltage at the input terminals satisfies the following conditions:
ACV: Between 1.3V and 999.9V DCV: Between 2.1V and 999.9V, or between -0.7V ~ -999.9V
The LCD display shows resistance (Ω) mode when the resistance at the input termi­nals satisfies the following conditions:
Resistance: Between 0 and Ω ACV: Between 0 and 0.9V
DCV: Between -0.4 and -0.2V DCV: Between 1.0 and 2.0V
The LCD display shows diode mode when the voltage at the input terminals satisfies the following conditions:
DCV: Between 0.4 and 0.8V
The LCD display shows AC current (A) mode when the current sensed by the jaws satisfies the following conditions :
ACA: Between 0.9A and 600.0A
Data Hold
Data-hold mode is not available when “OL KΩ“ is displayed with no input Signal present.
EN - 10
Data Hold Beep Guard
The internal sounder will beep continuously and the LCD display will flash if either of the following two situations are met in Data
-hold mode :
1. The instrument measures a characteristic different from the LCD reading; e.g. a voltage reading is held on the display and an attempt is made to measure an AC current .
2. The measured signal is the same characteristic as the LCD reading, but is 50 counts or more greater than the held LCD reading.
Auto Hold ( ACA only )
EN - 11
Auto Power-off
Battery Replacement
When the low battery indicator "<" appears on the LCD, replace the batteries with the type given in the specifications.
WARNING
Disconnect the test leads from the circuit and the instrument before removing the battery cover.
Refer to the following figure to replace the batteries:
EN - 12
Specifications
1-1 General Specifications
LCD display :
4 full large scale LCD readout.
Measuring rate : 5 times / sec. Overrange display : “OL” is displayed for
Ω” functions, shows the real value is shown for the “A” and “V” functions.
Automatic power off time :
Approximately 20 minutes after power on without operations. Low battery indicator : < is displayed. Replace the battery when the indicator < appears in the display.
Power requirement : 9V battery Battery life : Approximately 250 hours
approximately.
1-2 Environmental Conditions
Indoor use only. Calibration : One year calibration cycle. Operating temperature :
0°C to 30°C (32°F to 86°F) @ ≦ 80% RH
30°C to 40°C (86°F to104°F) @75% RH)
40°C to 50°C (104°F to 122°F) 45%RH Storage temperature : -20 to + 60°C
(-4°F to 140°F) @ 0 to 80% RH with batteries removed from the instrument.
Measurement Category (Installation Category) :
per IEC 61010-1:2001: CAT.Ⅲ 600V. Measurement Category l is for measure-
ments performed on circuits not directly connected to mains. Examples include : Measurements on battery powered equip­ment and specially protected (internal) mains-derived circuits. Measurement Category ll is for measure­ments on circuits directly connected to the low voltage installation. Examples include: Household appliances, portable tools and similar equipment.
EN - 13
Measurement Category lll is for measure­ments performed in the building installation. Examples include measurements on distribution boards, junction boxes, socket­outlets and wiring and cables in the fixed installation. Measurement Category lV is for measure­ments performed at the source of the low-voltage installation. Examples include measurements on primary overcurrent protection devices and electricity meters.
Conductor Size :
27mm diameter maximum.
Pollution degree : 2 Operating altitude : 2000m (6562 ft) EMC : EN 61326-1 Shock vibration: Sinusoidal vibration per
MIL-T-28800E (5 to 55 Hz, 3g maximum).
Drop Protection :
4 feet drop onto hardwood or concrete floor.
EN - 14
1-3 Electrical Specifications
Accuracy is ±(% reading + number of
digits) at 23°C ± 5°C < 80%RH.
Temperature coefficient :
Add 0.2 x (Specified accuracy) / °C ,< 18°C > 28°C .
Voltage
Function Range Accuracy
V
1.3V ~ 750.0V
±(1.5%+ 3 dgt) 50Hz ~ 500Hz
V
2.1V ~ 1000V
±(1%+ 2 dgt)
-0.7V ~ 1000V
±(1%+ 4 dgt)
Overload protection :
1000 VDC / 750 VAC
Max Operation time: DT = 30s for 30V Input impedance : 4K for input voltage
up to 30V. Impedance increases with input voltage to approximate 375KΩ at 750V.
Resistance & Continuity & Diode
Function Range Accuracy
Ω ;
0.0Ω ~ 9999Ω ±(2% + 2 dgt)
0.4V ~ 0.8V
±(1% + 3 dgt)
Overload protection : 1000 VDC / 750 VAC Max. open circuit voltage : 2.0V Continuity check :
Internal sounder activates if the resistance of the circuit under test is less than 25Ω. It will then turn off if the resistance is increased beyond 400Ω. Specified from 0°C ~ 40°C.
AC Current
Function Range Accuracy
A
0.9A ~ 600.0A
±(1.9% + 5 dgt)* 50Hz ~ 60Hz
Overload protection : 600.0A 0 ~ 500A : Continuous Operation. * 501A ~ 600A: 10 minutes maximum
Followed by 10 minutes cooling period.
EN - 15
Limited Warranty
This instrument is warranted to the original purchaser against defects in material and workmanship for 3 year from the date of purchase. During this warranty period, RS Components will, at its option, replace or repair the defective unit, subject to verifica­tion of the defect or malfunction. This warranty does not cover disposable batteries, or damage from abuse, neglect, accident, unauthorized repair, alteration, contamination, or abnormal conditions of operation or handling. Any implied warranties arising out of the sale of this product, including but not lim­ited to implied warranties of merchantability and fitness for a particular purpose, are limited to the above. RS Components shall not be liable for loss of use of the instru­ment or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expense or economic loss. Some states or countries laws vary, so the above limita­tions or exclusions may not apply to you. For full terms and conditions, refer to the current RS Catalogue.
EN - 16
Africa RS Components SA
P.O. Box 12182, Vorna Valley, 1686 20 Indianapolis Street, Kyalami Business Park, Kyalami, Midrand South Africa
www.rs-components.com
Asia RS Components Pte Ltd.
31 Tech Park Crescent Singapore 638040
www.rs-components.com
China RS Components Ltd.
Suite 23 A-C East Sea Business Centre Phase 2 No. 618 Yan'an Eastern Road Shanghai, 200001 China
www.rs-components.com
Europe RS Components Ltd.
PO Box 99, Corby, Northants. NN17 9RS United Kingdom
www.rs-components.com
Japan RS Components Ltd.
West Tower (12th Floor), Yokohama Business Park, 134 Godocho, Hodogaya, Yokohama, Kanagawa 240-0005 Japan
www.rs-components.com
U.S.A Allied Electronics
7151 Jack Newell Blvd. S. Fort Worth, Texas 76118 U.S.A.
www.alliedelec.com
South America RS Componentes Limitada
Av. Pdte. Eduardo Frei M. 6001-71 Centro Empresas El Cortijo Conchali, Santiago, Chile
www.rs-components.com
Loading...