RSF Woodburning Fireplaces MicroAMP User Manual

MAKING THE DIFFERENCE
TO YOUR VISITOR EXPERIENCE
MicroAMP User Guide
Commercial Division
RSF Europe sa
10b, route d’Arlon L-7471 Saeul G.D. of Luxembourg
Tel. +352 49 74 20 40 Fax +352 49 74 20 50 info@rsf-int.com
Manufacturer
RSF
45, Av. Marcel Dassault 31500 Toulouse France
Tel. +33 5 61 20 79 09 Fax +33 5 61 80 00 94 www.rsf-int.com
MicroAMP
User Manual
MAKING THE DIFFERENCE
TO YOUR VISITOR EXPERIENCE
MicroAMP User Guide
Commercial Division
RSF Europe sa
10b, route d’Arlon L-7471 Saeul G.D. of Luxembourg
Tel. +352 49 74 20 40 Fax +352 49 74 20 50 info@rsf-int.com
Manufacturer
RSF
45, Av. Marcel Dassault 31500 Toulouse France
Tel. +33 5 61 20 79 09 Fax +33 5 61 80 00 94 www.rsf-int.com
Connections
The MicroAMP is a miniature audio amplier idea for installations where discretion is key. It’s small size and simple operation allow the installation and running simple enough to allow project managers to concentrate on more pressing matters.
All that needs to be done to use the MicroAMP is connect a line level audio source with RCA/cinch connectors, the speakers using phoenix blocks, and the 12V power adapter using a phoenix block or BT connector
Right channel input
Left channel input
Power input
Left output
Right output
Left volume control
Right volume control
MAKING THE DIFFERENCE
TO YOUR VISITOR EXPERIENCE
MicroAMP User Guide
Commercial Division
RSF Europe sa
10b, route d’Arlon L-7471 Saeul G.D. of Luxembourg
Tel. +352 49 74 20 40 Fax +352 49 74 20 50 info@rsf-int.com
Manufacturer
RSF
45, Av. Marcel Dassault 31500 Toulouse France
Tel. +33 5 61 20 79 09 Fax +33 5 61 80 00 94 www.rsf-int.com
Connect this unit’s AC power adaptor only to an AC outlet of the type stated in this Owner’s Manual or as marked on the unit. Failure to do so is a re and electrical shock hazard.
Do not allow water to enter this unit or allow the unit to become wet. Fire or electrical shock may result.
Do not place a container with liquid or small metal objects on top of this unit.
Liquid or metal objects inside this unit are a re and electrical shock hazard.
Do not place heavy objects, including this unit, on top of the power cord. A damaged power cord is a re and electrical shock hazard. In particula r, be careful not to place heavy objects on a power cord covered by a carpet.
Do not scratch, bend, twist, pull, or heat the power cord. A damaged power cord is a re and electrical shock hazard.
Do not remove the unit’s cover. You could receive an electrical shock. If you think internal inspection, maintenance, or repair is necessar y, contact your dealer.
Do not modify the unit. Doing so is a re and electrical shock hazard.
If lightning begins to occur, turn off the power switch of the unit as soon as possible, and unplug the power plug from the electrical outlet. If there is a possibi lity of lightning, do not touch the power plug if it is still connected. Doing so may be an electrical shock hazard.
Use only the included AC power adaptor for this unit.
Using other types may be a re and electrical shock hazard.
If the power cord is damaged (i.e., cut or a bare wire is exposed), ask your dealer for a replacement. Using the unit with a damaged power cord is a re and electrical shock hazard.
Should this unit and AC adaptor be dropped or the cabinet
be damaged, turn the power switch off, remove the power plug from the AC outlet, and contact your dealer. If you continue using the unit without heeding this instruction, re or electrical shock may result.
If you notice any abnormality, such as smoke, odour, or noise, or if a foreign object or liquid gets inside the unit, turn it off immediately. Remove the power plug from the AC outlet. Consult your dealer for repair. Using the unit in this condition is a re and electr ical shock hazard.
Keep this unit away from the following locations:
- Locations exposed to oil splashes or steam, such as near cooking stoves,humidiers, etc.
- Unstable sur faces, such as a wobbly table or slope.
- Locations exposed to excessive heat, such as inside a car with all the windows closed, or places that receive direct sunlig ht.
- Locations subject to excessive humidity or dust accumulation.
Hold the power plug when disconnecting it from an AC outlet. Never pull the cord. A damaged power cord is a potential re and electrical shock hazard.
Do not touch the power plug with wet hands. Doing so is a potential electrical shock hazard.
To relocate the unit, tur n the power switch of f, remove the power plug from the AC outlet, and remove all connecting cables. Damaged cables may cause re or electrical shock.
Do not cover or w rap the AC power adaptor w ith a cloth or blanket. Heat may build up under the cloth or blanket, melting the case, or causing re. Use only in a well-ventilated environment.
If you know you will not use this unit for a log period of time, such as when going on vacation, remove the power plug from the AC outlet. Leaving it connected is a potential re hazard.
Disposal of used batter ies The user is legally obliged (battery regulation) to return used batteries and storage batteries. Do not dispose of used batteries via the household rubbish! Batter ies/storage batter ies containing harmful substances are marked with the following symbols indicating that they are not allowed to be disposed of in the domestic refuse.
The designations for the respective hazardous heavy metals are: Cd = cadmium, Hg = mercury, Pb = lead. You can return used batteries/storage batteries free of charge to any collecting point in your local author ity or in any other store where batteries/storage batteries are sold.
CE certication
This product is EC-compliant with all required guidelines
MAKING THE DIFFERENCE
TO YOUR VISITOR EXPERIENCE
MicroAMP User Guide
Commercial Division
RSF Europe sa
10b, route d’Arlon L-7471 Saeul G.D. of Luxembourg
Tel. +352 49 74 20 40 Fax +352 49 74 20 50 info@rsf-int.com
Manufacturer
RSF
45, Av. Marcel Dassault 31500 Toulouse France
Tel. +33 5 61 20 79 09 Fax +33 5 61 80 00 94 www.rsf-int.com
Technical specications
Audio parameters
Bandwidth 20Hz to 20KHz Distortion below 0,01% Dynamic range 92 dB Amplier power 2 x 3 W RMS (4 Ohm) or 1 x 6 W (8 Ohm) (bridged mode)
Connectors
Audio input RCA cinch (2X) Audio output Twin contact Phoenix Block terminal (x2) Power supply Twin contact Phoenix Block terminal or BT connector Power supply 12VDC / 500 mA (external)
Maximum consumption 0,5W to 2,5W Enclosure Black metal casing Dimensions (enclosure) 114x78x28 mm (L x W x H) Weight 115 gr (without PSU) Environment
Temperature 0°C (32°F) to 50°C (122°F) Humidity 0-90% Warranty 8 years