R&S NGL201, NGL202, NGL-K103, NGM-K103, NGM201 Application Note

...
Application Note
SWITCHING OUTPUTS OF MULTIPLE DC POWER SUPPLIES R&S®NGL200 / R&S®NGM200
Products:
R&S
®
NGL201
R&S
®
NGL202
R&S
®
NGM201
R&S
®
NGM202
R&S
®
NGL-K103
R&S
®
NGM-K103
Thomas Lechner | 1GP126 | Version 2e | 06.2020 https://www.rohde-schwarz.com/appnote/1GP126
Rohde & Schwarz | Application Note Switching outputs of Multiple DC Power Supplies R&S®NGL200 /
R&S®NGM200 2
Contents
1 Overview ........................................................................................................ 3
2 Background ................................................................................................... 4
2.1 Prerequisites .......................................................................................................4
2.2 Principle of the synchronization ...........................................................................4
2.2.1 Switching on ........................................................................................................4
2.2.2 Switching off ........................................................................................................4
3 Preparations .................................................................................................. 4
3.1 Connections between the instruments ................................................................4
3.2 Settings ...............................................................................................................5
3.2.1 Device ................................ ................................ ................................ .................5
3.2.2 Channel 1/2 .........................................................................................................7
4 Operation ....................................................................................................... 8
5 Literature ....................................................................................................... 8
6 Ordering Information .................................................................................... 8
Rohde & Schwarz | Application Note Switching outputs of Multiple DC Power Supplies R&S®NGL200 /
R&S®NGM200 3
1 Overview
All channels of DC power supplies R&S®NGL200 and R&S®NGM200 are isolated against the grounding equipment conductor and against the digital ground of the instrument. Therefore, channels can be connected in parallel for increasing the current capability, or in series for achieving higher voltages or dual-voltage supplies. In the case of parallel and serial connections it is usually desired to switch all channels simultaneously on and off for protecting the supplied circuitry and for avoiding overcurrent on other power supply channels.
This application note describes how to connect and configure DC power supplies R&S®NGL200 and R&S®NGM200 for synchronized on and off switching of all channels across multiple power supplies.
Loading...