RS IDM 503, IDM 505 Instruction Manual

EN
Instruction Manual IDM 503 & IDM 505 Digital Multimeters
IDM 505
IDM 503 / 505 English
2
SECTION 1 –SAFETY INFORMATION
Safety Information
Understand and follow operating instructions carefully. Use the Instrument only as specied in this manual; otherwise, the protection provided by the Instrument may be impaired.
WARNING Identies hazardous conditions and actions that could cause BODILY HARM or DEATH
CAUTION
Identies conditions and actions that could DAMAGE the Instrument or equipment under test
WARNING
- Examine the instrument and probes before use. Do not use the instrument if it is wet or damaged
- When using test leads or probes, keep your ngers behind the nger guards.
- Remove the test lead from the instrument before opening the battery cover or instrument case.
- Always use the correct terminals, switch position and range for measurements.
- Never attempt a voltage measurement with the test leads inserted into the
“A”input terminals.
- Verify the instrument is operating correctly by measuring a known voltage
- before use. If in doubt, have the instrument serviced.
- Do not apply more than the rated voltage, as marked on the instrument, between terminals or between any terminal and earth ground.
- Do not attempt a current measurement when the open-circuit voltage is above the fuse protection rating.
- Only replace a fuse with the correct type and rating as specied in this instruction manual.
- Use caution when measuring voltages above 30 Vac rms, 42 Vac peak or 60
Vdc. These voltages pose a shock hazard.
- To avoid false readings that can lead to electric shock, replace the battery as soon as the low battery indicator appears in the display.
- Disconnect the circuit power and discharge all high-voltage capacitors before
making resistance, current, continuity, diode or capacitance measurements.
- Do not use the instrument in a hazardous area or around explosive gasses or vapours.
- Wear suitable personal protective equipment when working around or near
hazardous live conductors which could be accessible.
IDM 503 / 505 English
3
CAUTION
• Disconnect the test leads from the test points before changing the position of the function rotary switch.
• Never connect a source of voltage with the function rotary switch in the
“Ω”, “ ” , “°C” , “mA”, or “A” position.
Do not expose the instrument to extremes in temperature or high humidity.
Never set the instrument in the “Ω”, “ ” , “°C” , “mA”, or “A” position to measure
the voltage of a circuit, this could result in damage the instrument and the equipment under test.
Symbols as marked on the instrument and instruction manual
Maintenance
Do not attempt to repair this instrument. It contains no user serviceable parts.
Repair or servicing should only be performed by qualied personnel.
Risk of electric shock
See instruction manual
DC measurement
Equipment protected by double or reinforced Insulation
Battery
Fuse
Earth
AC measurement
Conforms to EU directives
Dispose of in accordance with local regulations.
IDM 503 / 505 English
4
Unsafe Voltage
To alert you to the presence of a potentially hazardous voltage when the rotary switch is in
V or mV position symbols are displayed as detailed in the table below:
Hazardous voltage in 503
IDM503
Function Range Input
Mode
Auto Test AC DC AC+DC
mV
40.00mV
0 - 40mVac Reading Reading N/A Reading
>40mVac OL N/A OL
0 - 40mVdc Reading N/A Reading Reading
>40mVdc N/A OL OL
400.0mV
0 - 40mVac Reading N/A Reading
40 - 400mVac Reading Reading N/A Reading
>400mVac OL OL N/A OL
0 - 40mVdc N/A Reading Reading
40 - 400mVdc Reading N/A Reading Reading
>400mVdc OL N/A OL OL
V
4.000V
0 - 4Vac Reading Reading N/A Reading
>4Vac OL N/A OL
0 - 4Vdc Reading N/A Reading Reading
>4Vdc N/A OL OL
40.00V
0 - 4Vac Reading N/A Reading
4 - 30Vac Reading Reading N/A Reading
30 - 40Vac Reading Reading N/A Reading
>40Vac OL N/A OL
0 - 4Vdc N/A Reading Reading
4 - 30Vdc Reading N/A Reading Reading
30 - 40Vdc Reading N/A Reading Reading
>40Vdc N/A O L OL
400.0V
0 - 30Vac Reading N/A Reading
30 - 40Vac Reading N/A Reading
40 - 400Vac Reading Reading N/A Reading
>400Vac OL N/A OL
0 - 30Vdc N/A Reading Reading
30 - 40Vdc N/A Reading Reading
40 - 60Vdc Reading N/A Reading Reading
60 – 400Vdc Reading N/A Reading Reading
>400Vdc N/A O L OL
1000V
0 - 30Vac Reading N/A Reading
30 - 400Vac Reading N/A Reading
400 - 1000Vac Reading Reading N/A Reading
>1000Vac OL OL N/A OL
0 - 30Vdc N/A Reading Reading
30 - 60Vdc N/A Reading Reading
60 - 400Vdc N/A Reading Reading
400 - 1000Vdc Reading N/A Reading Reading
>1000Vdc OL N/A O L OL
0
0
0
0 0
0
0
0
0
0 0
00
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0 0 0
0
00 0
0 0 000
0
0
0
0
0
0
00
0
00
00
IDM 503 / 505 English
5
Note: This symbol “-” indicates that the measurement does not show in the display.
The symbol “N/A” indicates that the measurement is unspecied.
Hazardous voltage in 505
IDM505
Function Range Input
Mode
Auto Test AC DC AC+DC
mV
100.00mV
0 - 100mVac Reading Reading N/A Reading
>100mVac - OL N/A OL
0 - 100mVdc Reading N/A Reading Reading
>100mVdc - N/A OL OL
1000.0mV
0 - 100mVac - Reading N/A Reading
100 - 1000mVac Reading Reading N/A Reading
>1000mVac OL OL N/A OL
0 - 100mVdc - N/A Reading Reading
100 - 1000mVdc Reading N/A Reading Reading
>1000mVdc OL N/A OL OL
V
10.000V
0 - 10Vac Reading Reading N/A Reading
>10Vac - OL N/A OL
0 - 10Vdc Reading N/A Reading Reading
>10Vdc - N/A OL OL
100.00V
0 - 10Vac - Reading N/A Reading
10 - 30Vac Reading Reading N/A Reading
30 - 100Vac Reading Reading N/A Reading
>100Vac - OL N/A OL
0 - 10Vdc - N/A Reading Reading
10 - 30Vdc Reading N/A Reading Reading
30 - 60Vdc Reading N/A Reading Reading
60 - 100Vdc Reading N/A Reading Reading
>100Vdc - N/A OL OL
1000.0V
0 - 30Vac - Reading N/A Reading
30 - 100Vac - Reading N/A Reading
100 - 1000Vac Reading Reading N/A Reading
>1000Vac OL OL N/A OL
0 - 30Vdc - N/A Reading Reading
30 - 60Vdc - N/A Reading Reading
60 - 100Vdc - N/A Reading Reading
100 - 1000Vdc Reading N/A Reading Reading
>1000Vdc OL N/A O L OL
0 0
00
000
000
00
00
00
00
000
000
0 0
0
0
0
0
000
0
000
0
000
0
IDM 503 / 505 English
6
Cleaning
Periodically wipe the case with a dry cloth and detergent. Do not use abrasives or solvents.
SECTION 2 - METER DESCRIPTION
Instrument Description
Front Panel Illustration
1. LCD display : 4000/40000 counts for IDM503.
10000/100000 counts for IDM505.
2. Push-buttons.
3. Rotary switch to turn the power on or off and to select a function.
4. Input Terminal for “A” (current measurement)
5. Input Terminal for “V”, “Ω”, “
”, Hz, and °C functions.
6. Common (ground reference) input terminal.
7. Input terminal for mA current measurement.
IDM 503 / 505 English
7
Making Basic Measurements
SECTION 3 – METER DESCRIPTION
Preparation and caution before measurement
Observe all warnings and cautions
When connecting the test leads to the device under test connect the common test lead
before connecting the live lead ; when removing the test leads remove the test live lead
before removing the common test lead.
The gures on the following pages show how to make basic measurements.
Measuring AC / DC Voltage
IDM 503 / 505 English
8
High Frequency Reject mode (HFR)
The HFR mode measures the voltage through a low pass lter to reject the high frequency. The –3dB point of the low pass lter is 800 Hz. The HFR mode can be used when the rotary switch is in the “V”, “mV” position. To use HFR mode, press the “HFR” button.
Measuring Resistance / Continuity / Diode Capacitance
Testing Continuity
IDM 503 / 505 English
9
Diode Testing
Measuring AC/DC Current
Press the blue button to select the measuring function (AC/DC/AC+DC)
IDM 503 / 505 English
10
Measuring Frequency
Press the blue button to select the measuring function. (Period/Duty)
Measuring Temperature °C / °F
Press the blue button to select the measuring function. (°C / °F)
Loading...
+ 22 hidden pages