PRODUCT SPECIFICATIONS
TWO STAGE VARIABLE SPEED
GAS FURNACE
FORM NO. 96G2V-100 (08/2019)
HEAT EXCHANGER DESIGN
• Aluminized steel primary heat exchanger with crimped non­welded construction
• AL29-4C Stainless steel secondary heat exchanger
• Non-welded crimped S-curve primary heat exchanger design for maximum durability
BURNERS
• Aluminized steel in shot burners for smooth ignition
CABINET CONSTRUCTION
• Compact 33" height
• Standardized widths for easy coil fit
• Unitized construction for cabinet integrity
• Heat exchanger compartment is insulated to increase efficiency and reduce sound levels
• Baked on pre painted steel cabinet finish
CONFIGURATIONS
• Upflow / Horizontal
• Downflow
VENTING
• 2-speed induced draft motor with stainless steel shaft, steel ball bearings, and fan cooled for long life
• Vent materials for Canadian applications must comply with ULC S636
• Certified for direct vent (2-pipe) or non-direct (1-pipe) applications
• Direct vent refers to a combustion air supply intake pipe installed in conjunction with flue gas vent pipe.
INSTALLATION FEATURES
• Left or right gas and electric entry
• Zero step horizontal conversion
• Removable floor base (upflow/horizontal units) for bottom return air
• All models comply with California's South Coast Air Quality Management district Low NOx requirements
AIR DELIVERY SYSTEM
• Efficient ECM variable speed blower motor
• Motor features "soft start" and "soft stop" for quiet operation
• Active and passive dehumidification feature
• Easily removable slide-out blower design
• Dynamically balanced blower wheel with resilient motor mounts for smooth and quiet operation
CONTROLS
• Two stage gas valve
• Integrated ignition and fan control
• System Sentry™ control retains last five (5) fault codes with push button memory recall, regardless of power interruption
• Hot surface ignition system uses silicon nitride ignitor
• Control features 120 volt electronic air cleaner and humidifier terminals
• Control circuit is fuse protected
• Color coded control wiring
• Compatible with single or two stage thermostats for heating.
• Two stage thermostat is recommended when installed with two stage cooling unit.
WARRANTY
10 year limited parts warranty / lifetime heat exchanger warranty available. See limited warranty document for details.
California Only If installed in South Coast Air Quality Management District (SCAQMD) only: This furnace does not meet the SCAQMD Rule 1111 NOx emission limit (14 ng/J), and thus is subject to a mitigation fee of up to $450. This furnace is not eligible for the Clean Air Furnace Rebate Program: www.CleanAirFurnaceRebate.com. If installed in San Joaquin Valley Air Pollution Control District (SJVAPCD) only: This furnace does not meet the SJVAPCD Rule 4905 NOx emission limit (14 ng/J), and thus is subject to a mitigation fee of up to $450.
Page 1
96% GAS FURNACE 96G2V
MODEL NUMBER GUIDE
96 G 2 UH 110 C V 16 -01
AFUE
96 = 96% EFFICENCY
GAS
STAGE S
2 = TWO STAGE
CONFIGURATION
UH = UPFLOW/HORIZONTAL
DF = DOWN FLOW
BTUH INPUT
HEATING INPUT X 1000
CABINET WIDTH
B = 17.5” WIDTH
C = 21.0” WIDTH
D = 24.5” WIDTH
PHYSICAL AND ELECTRICAL DATA
1ST STAGE 2ND STAGE
MODEL
INPUT
(BTUH)
OUTPUT
(BTUH)
INPUT
(BTUH)
OUTPUT
(BTUH)
AFUE
(ICUS)
NOM.
COOLING
CAPACITY
(TONS)
GAS
INLET
(IN.)
NUMERIC CODE
REVISION CODE
NOM. CFM X 00
12 = 3 TON ADD ON COOLING 16 = 4 TON ADD ON COOLING 20 = 5 TON A DD ON COOLING
BLOWER DRIVE
V = VARIABLE SPEED
VOLTS/
HZ/
PHASE
MIN.
TIME
DELAY
BREAKER
OR FUSE
NOMINAL
F.L.A.
TRANS.
(V.A.)
APPROX.
WEIGHT
(LBS.)
96G2UH045BV12 29,000 28,000 44,000 42,000 96.0 3 1/2 120-60-1 15 7.7 40 130
96G2UH070BV12 43,000 41,000 66,000 62,000 96.0 3 1/2 120-60-1 15 7. 7 40 138
96G2UH090CV12 57,000 55,000 88,000 84,000 96.0 3 1/2 120-60-1 15 7.7 40 154
96G2UH090CV20 57,000 55,000 88,000 85,000 96.0 5 1/2 120-60-1 20 12.8 40 166
96G2UH110CV20 72,000 70,000 110,000 105,000 96.0 4 1/2 120-60-1 15 12.8 40 173
UPFLOW/HORIZONTAL
96G2UH135DV20 88,000 84,000 132,000 126,000 96.0 5 1/2 120-60-1 20 12.8 40 188
96G2DF070BV16 43,000 42,000 66,000 64,000 96.0 4 1/2 120-60-1 15 10.1 40 136
96G2DF090CV20 57,000 56,000 88,000 85,000 96.0 5 1/2 120-60-1 20 12.8 40 164
96G2DF110CV20 72,000 70,000 110,000 106,000 96.0 5 1/2 120-60-1 20 12.8 40 176
DOWNFLOW
Note: For vent length and clearances to combustibles, please reference installation instructions.
FILTER REQUIREMENT DATA
Airflow
Descriptor
12 576 288
16 768 384
20 960 480
Disposable Filters Cleanable Filters
Minimum Area
(sq. in.)
Minimum Area
(sq.in.)
1. The A irflow D escriptor is the two digits following the "B", "C" , or "D" in the mode l number; e.g. "20" is th e Airfl ow Descriptor.
2. Areas shown for p ermane nt filter s are based on filters rated at 60 0 feet pe r minute face velocity.
Page 2