Royalton B2332506, B2332507, B2332505 User Manual

Page 1
95G1E
PRODUCT SPECIFICATIONS
SINGLE STAGE
CONSTANT TORQUE MOTOR
FORM NO. 95G1E-100 (04/2018)
VENTING
• Designed certified for direct (2-pipe) and non direct (1-pipe) applications
• Easily vented with PVC pipe
INSTALLATION FEATURES
• Left or right utility connection
• Design certified for direct and non-direct vent applications
• Zero step horizontal conversion
• Removable floor base (upflow / horizontal units) for bottom return air
• Complies with California’s South Coast Air Quality Management district Low NOx requirements
WARRANTY
10 year limited parts warranty / lifetime heat exchanger warranty available. See limited warranty document for details.
CONFIGURATIONS
• Upflow / Horizontal
• Downflow
HEAT EXCHANGER DESIGN
• Aluminized steel primary heat exchanger with crimped non­welded construction
• AL 29-4C Stainless steel secondary heat exchanger
BURNER
CABINET DESIGN
• Compact 33” height
• Standardized widths for easy coil fit
AIR DELIVERY SYSTEM
• Multi-speed high efficiency (constant torque) blower motor
• Easily removable slide out blower design
• Enhanced cooling SEER ratings when applied with properly matched cooling equipment.
CONTROLS
• Single stage gas valve
• Durable silicon nitride ignitor
• Self diagnostics saves last 10 fault codes regardless of power interruption
• Control features electronic air cleaner and humidifier terminals
Page 1
Page 2
95% GAS FURNACE 95G1E
MODEL NUMBER GUIDE
95 G 1 UH 070 B E 12 -01
AFUE
95% EFFICENCY
GAS
GAS
STAGE S
1 = 1 STAGE
CONFIGURATION
UH = UPFLOW/HORIZONTAL
DF = DOWN FLOW
BTUH INPUT
HEATING INPUT X 1 000
CABINET WIDTH
B = 17.5” WIDTH
C = 21.0” WIDTH
D = 24.5” WIDTH
PHYSICAL AND ELECTRICAL DATA
MAJOR REVISION
NUMERIC CODE
CFM
12 = 3 TON ADD ON COOLING 16 = 4 TON ADD ON COOLING 20 = 5 TON ADD ON COOLING
BLOWER DRIVE
P = PSC E = HIGH EFFICENCY V= VARIABLE SPEED
Model
95G1UH045BE12 44,000 42,000 95.0% 1-1/2 — 3 1/2 120 - 60 - 1 15 6.8 40 129
95G1UH070BE12 66,000 64,000 95.0% 1-1/2 — 3 1/2 120 - 60 - 1 15 6.8 40 134
95G1UH090CE16 88,000 85,000 95.0% 2-1/2 — 4 1/2 120 - 60 - 1 15 8.4 40 158
95G1UH110CE20 110,000 106,000 95.0% 3 — 5 1/2 120 - 60 - 1 15 10.9 40 170
UPFLOW/HORIZONTAL
95G1UH135DE20 132,000 128,000 95.0% 3-1/2 — 5 1/2 120 - 60 - 1 15 10.9 40 187
95G1DF045BE12 44,000 42,000 95.0% 1-1/2 — 3 1/2 120 - 60 - 1 15 6.8 40 131
95G1DF070BE16 66,000 64,000 95.0% 2-1/2 — 4 1/2 120 - 60 - 1 15 8.4 40 144
95G1DF090CE16 88,000 85,000 95.0% 2-1/2 — 4 1/2 120 - 60 - 1 15 8.4 40 160
DOWNFLOW
95G1DF110CE20 110,000 106,000 95.0% 3 — 5 1/2 120 - 60 - 1 15 10.9 40 174
Note: For vent length and clearances to combustibles, please reference installation instructions.
Input
(Btuh)
Output
(Btuh)
AFUE
(ICS)
Nom.
Cooling
Capacity
Gas Inlet (in.)
Volts/
Hz/
Phase
Max. Time
Delay Breaker or Fuse
Nominal
F.L.A.
Trans. (V.A.)
Approx.
Shipping
Weight
(lbs.)
Page 2
Page 3
95% GAS FURNACE 95G1E
BLOWER PERFORMANCE DATA
Upflow / Horizontal
Downflow
Model
95G1UH045BE12
95G1UH070BE12
95G1UH090CE16
95G1UH110CE20
95G1UH135DE20
95G1DF045BE12
95G1DF070BE16
95G1DF090CE16
95G1DF110CE20
Motor
Size (hp)
1/2 10 x 8 35 - 65
1/2 10 x 8 35 - 65
3/4 10 x 10 40 - 70
1 11-1/2 x 10 45 - 75
1 11-1/2 x 10 50 - 80
1/2 10 x 8 25-55
3/4 11-1/2 x 10 25-55
3/4 10 x 10 40-70
Blower
Size
1 11 x 11 40-70
Temp
Rise (F°)
Blower
CFM @ external static pressure - " w.c.
Speed
High 1290 1275 1220 1215 1190 N /A N /A
Med/High 1190 1150 1120 1090 1060 1015 1000
Med 1080 1045 1015 980 950 900 870
Med/Low 825 785 735 705 650 620 580
Low 780 720 690 635 600 555 520
High 1310 1275 1250 1215 1200 1145 N /A
Med/High 1250 1205 1175 1145 1100 1070 1035
Med 1130 1100 1065 1045 995 960 925
Med/Low 880 835 795 745 705 670 61 0
Low 815 775 730 670 640 585 550
High 1660 1615 1590 1560 1525 1475 N /A
Med/High 1435 1390 1350 1310 1255 1220 1170
Med 1290 1240 1200 1155 1105 1065 1010
Med/Low 1195 1140 1110 1055 1005 960 920
Low 1045 995 945 895 855 805 760
High 2130 2095 2065 2030 1995 1955 1930
Med/High 1865 1835 1785 1755 1705 1660 1635
Med 1670 1640 1600 1560 1525 1475 1445
Med/Low 1560 1525 1465 1425 1380 1350 1300
Low 1345 1285 1250 1215 1150 1100 1050
High 2330 2295 2275 2225 2185 N/A N/A
Med/High 2180 2120 2075 2035 2020 1940 1890
Med 1950 1925 1885 1845 1815 1736 1715
Med/Low 1745 1690 1640 1605 1565 1520 1465
Low 1535 1480 1445 1395 1330 1310 1285
High 1320 1285 1275 1230 1185 N /A N /A
Med/High 1215 1165 1150 1095 1060 1020 980
Med 1090 1065 1025 985 935 915 860
Med/Low 825 795 750 705 655 590 555
Low 785 735 705 650 605 545 485
High 1705 1665 1605 1585 1540 N /A N /A
Med/High 1470 1430 1390 1335 1300 1260 1220
Med 1265 1235 1185 1155 1100 1050 1015
Med/Low 1165 1120 1070 1015 970 915 865
Low 895 835 775 690 625 570 520
High 1685 1630 1620 1570 1540 N /A N /A
Med/High 1455 1415 1370 1335 1295 1260 1210
Med 1310 1285 1245 1185 1145 1110 1060
Med/Low 1220 1165 1125 1080 1045 990 940
Low 1080 1035 985 925 875 825 760
High 2185 2150 2085 2060 2005 1970 1910
Med/High 1910 1850 1810 1765 1700 1665 1620
Med 1720 1670 1605 1565 1510 1460 1420
Med/Low 1575 1525 1465 1420 1370 1325 1275
Low 1360 1290 1255 1190 1160 1100 1045
.20 .30 .40 .50 .60 .70 .80
Page 3
Page 4
95% GAS FURNACE 95G1E
DIMENSIONS (IN.)
Model A B C D
95G1UH045BE12S 17-1/2 16-3/8 16 7-5/8
95G1UH070BE12S 17-1/2 16-3/8 16 7-5/8
95G1UH090CE16S 21 19-7/8 19-1/2 9-3/8
Upow / Horizontal
95G1UH110CE20S 21 19-7/8 19-1/2 9-3/8
95G1UH135DE20S 24-1/2 23-3/8 23 11-1/8
95G1DF045BE12S 17-1/2 16-3/8 16 15-1/2
95G1DF070BE16S 17-1/2 16-3/8 16 15-1/2
Downflow
95G1DF090CE16S 21 19-7/8 19-1/2 19
95G1DF110CE20S 21 19-7/8 19-1/2 19
Front View
Page 4
Page 5
95% GAS FURNACE 95G1E
Dimensions (in.)
DIMENSIONS (IN.)
AIR
FLOW
23 -1/2
AIR
FLOW
Page 5
Page 6
95% GAS FURNACE 95G1E
ACCESSORY LIST
CATALOG NUMBER DESCRIPTION
EXTERNAL FILTER RACK KITS
1.841018 1 pack (16 x 25)
1.841039 10 pack (16 x 25)
NATURAL TO LP KITS
11K50 1-Stage
11K45 High Altitude 1-Stage
13X57 30K BTUH
RETURN AIR BASE
68W62 17.5" B Width
68W63 21.0" C Width
68W64 24.5" D Width
DOWNFLOW COMBUSTIBLE FLOORING BASE
11M60 17.5" B Width
11M61 21.0" C Width
NIGHT SERVICE KITS
86W57 Single Stage
HORIZONTAL SUSPENSION KIT
51W10 80% & 90% Kit
FLUSH MOUNT TERMINATION (90% FURNACES ONLY) US ONLY
51W11 2" & 3" Vent Version
CONCENTRIC VENT KIT (90% FURNACES ONLY) US ONLY
71M80 1-1/2" Vent Version
69M29 2" Vent Version
60L46 3" Vent Version
CONCENTRIC VENT KIT (90% FURNACES ONLY) CANADA
44W92 1-1/2" and 2" Vent Version
44W93 3" Vent Version
2-STAGE COMPRESSOR RELAY KIT
85W66 Blower Relay Kit
Twinning kit
16W72
Constant Torque Gas Furnace
Twinning Kit
For vent length and clearances to combustibles, please reference installation instructions.
All specifications and illustrations subject to change without notice and without incurring obligations.
FORM NO. 95G1E-100 (04/2018) Printed in the U.S.A.©2018 Allied Air Enterprises LLC, a Lennox International Inc. Company
1-800-448-5872
Page 6