95G1E
PRODUCT SPECIFICATIONS
SINGLE STAGE
CONSTANT TORQUE MOTOR
FORM NO. 95G1E-100 (04/2018)
VENTING
• Designed certified for direct (2-pipe) and non direct (1-pipe)
applications
• Easily vented with PVC pipe
INSTALLATION FEATURES
• Left or right utility connection
• Design certified for direct and non-direct vent applications
• Zero step horizontal conversion
• Removable floor base (upflow / horizontal units) for bottom
return air
• Complies with California’s South Coast Air Quality
Management district Low NOx requirements
WARRANTY
10 year limited parts warranty / lifetime heat exchanger warranty
available. See limited warranty document for details.
CONFIGURATIONS
• Upflow / Horizontal
• Downflow
HEAT EXCHANGER DESIGN
• Aluminized steel primary heat exchanger with crimped nonwelded construction
• AL 29-4C Stainless steel secondary heat exchanger
BURNER
• Aluminized steel inshot burners for smooth ignition
CABINET DESIGN
• Compact 33” height
• Standardized widths for easy coil fit
AIR DELIVERY SYSTEM
• Multi-speed high efficiency (constant torque) blower motor
• Easily removable slide out blower design
• Enhanced cooling SEER ratings when applied with properly
matched cooling equipment.
CONTROLS
• Single stage gas valve
• Durable silicon nitride ignitor
• Self diagnostics saves last 10 fault codes regardless of power
interruption
• Control features electronic air cleaner and humidifier terminals
Page 1
95% GAS FURNACE 95G1E
MODEL NUMBER GUIDE
95 G 1 UH 070 B E 12 -01
AFUE
95% EFFICENCY
GAS
GAS
STAGE S
1 = 1 STAGE
CONFIGURATION
UH = UPFLOW/HORIZONTAL
DF = DOWN FLOW
BTUH INPUT
HEATING INPUT X 1 000
CABINET WIDTH
B = 17.5” WIDTH
C = 21.0” WIDTH
D = 24.5” WIDTH
PHYSICAL AND ELECTRICAL DATA
MAJOR REVISION
NUMERIC CODE
CFM
12 = 3 TON ADD ON COOLING
16 = 4 TON ADD ON COOLING
20 = 5 TON ADD ON COOLING
BLOWER DRIVE
P = PSC
E = HIGH EFFICENCY
V= VARIABLE SPEED
Model
95G1UH045BE12 44,000 42,000 95.0% 1-1/2 — 3 1/2 120 - 60 - 1 15 6.8 40 129
95G1UH070BE12 66,000 64,000 95.0% 1-1/2 — 3 1/2 120 - 60 - 1 15 6.8 40 134
95G1UH090CE16 88,000 85,000 95.0% 2-1/2 — 4 1/2 120 - 60 - 1 15 8.4 40 158
95G1UH110CE20 110,000 106,000 95.0% 3 — 5 1/2 120 - 60 - 1 15 10.9 40 170
UPFLOW/HORIZONTAL
95G1UH135DE20 132,000 128,000 95.0% 3-1/2 — 5 1/2 120 - 60 - 1 15 10.9 40 187
95G1DF045BE12 44,000 42,000 95.0% 1-1/2 — 3 1/2 120 - 60 - 1 15 6.8 40 131
95G1DF070BE16 66,000 64,000 95.0% 2-1/2 — 4 1/2 120 - 60 - 1 15 8.4 40 144
95G1DF090CE16 88,000 85,000 95.0% 2-1/2 — 4 1/2 120 - 60 - 1 15 8.4 40 160
DOWNFLOW
95G1DF110CE20 110,000 106,000 95.0% 3 — 5 1/2 120 - 60 - 1 15 10.9 40 174
Note: For vent length and clearances to combustibles, please reference installation instructions.
Input
(Btuh)
Output
(Btuh)
AFUE
(ICS)
Nom.
Cooling
Capacity
Gas
Inlet
(in.)
Volts/
Hz/
Phase
Max.
Time
Delay
Breaker
or Fuse
Nominal
F.L.A.
Trans.
(V.A.)
Approx.
Shipping
Weight
(lbs.)
Page 2