Royal Sovereign ARP-908, ARP-910 User Manual

Owner’s Manual
Portable Air Conditioner
Royal Sovereign International,Inc.
Please read and retain these instructions.
For more information, please go to www.royalsovereign.com
ARP-908 ARP-910
CONTENTS
SAFETY INSTRUCTIONS ................................................................... 3-4
PRODUCT VIEW .............................................................................. 5
INSTALLATION ................................................................................ 6-7
PRODUCT OPERATION ..................................................................... 8-11
MAINTENANCE OF THE MACHINE ....................................................... 12-13
TROUBLESHOOTING ........................................................................ 14
SPECIFICATIONS ............................................................................. 15
WARRANTY .................................................................................... 16
2
3
When using this appliance follow these safety precautions to reduce risk of fire, electric shock, or injury.
Read & Fully Understand This Owner’s Manual Before Using This Machine.
SAFETY INSTRUCTIONS
WARNING
Electrical Safety
1. For your safety, this appliance should be properly grounded on a level surface indoors.
2. The appliance should be placed near an electrical outlet so that the outlet is easily accessible.
3. Make sure the voltage meets the appliance’s electricity requirements (115-120V/60Hz).
4. Do not connect this machine to an outlet having the electrical ratings below or above this machine.
5. In case of any abnormality, be sure to turn off the machine, disconnect the plug, and contact Royal Sovereign Customer Service.
6. Do not operate if the electrical plug or power cord is damaged. If damaged, call Royal Sovereign Customer Service for repair/replacement.
7. Do not under any circumstances alter the electric plug.
8. Do not place heavy items on the plug or cord.
9. Do not plug this cord into a loose electrical outlet.
10. Only plug the appliance into a properly installed, grounded 3 prong outlet.
11. If the electrical outlet you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, you should have a qualified electrician install the proper outlet.
12. Do not share the electrical socket with other appliances.
13. Do not use an adapter plug or extension cord with this appliance.
14. Never attempt to turn off this machine by disconnecting the plug.
15. When plugging or unplugging, keep your hands dry.
16. Always grasp the plug when plugging or unplugging the appliance. Never unplug by pulling on the cord.
17. Do not pull on the power cord while moving the unit.
18. This unit uses a plug with a built-in fuse. Conduct a Power Plug Check (see Operation page 8) before use to confirm normal operation.
19. Turn the unit off and unplug when; cleaning the air conditioner, removing the filters, or not using the air conditioner for an extended time period.
When using this appliance follow these safety precautions to reduce risk of fire, electric shock, or injury.
Read & Fully Understand This Owner’s Manual Before Using This Machine.
SAFETY INSTRUCTIONS
WARNING
Operational Safety
1. Install the air conditioner according to the installation instructions supplied (Installation pages 6-7).
2. Do not block air outlets or intake with obstacles.
3. Do not insert any objects into the air conditioner.
4. Do not place heavy items or sit on the unit.
5. Do not place flammable or chemical substances near the unit.
6. Do not place this machine near heating appliances.
7. Do not splash or pour water on the housing or control panel.
8. To prevent the water from freezing, do not use this machine and the drain hose at a temperature below 41°F (5°C).
9. Make sure the rubber drain plugs are securely plugged into the drain ports on the back of the unit to prevent water leaks.
10. Drain the unit before moving the air conditioner or storing the unit.
11. Do not operate the unit with the back cover removed.
12. Do not use this machine outside.
13. Do not modify any part of this product.
14. Do not operate this appliance for any other purpose other than its intended use.
15. This appliance is not designed for use by young children. Young children should be supervised to ensure that they do not play with or climb on the unit.
4
1. Display panel
2. Air outlet
3. Caster wheels
4. Air filters
5. Exhaust duct (with connectors attached)
6. Drainage ports
5
PRODUCT VIEW
4
4
5
6
6
1
2
3
INSTALLATION
Accessories Included
1. Window seal plate
2. Exhaust duct connectors (2)
3. Exhaust duct
4. Remote control
5. Drainage hose
6. Instruction manual
NOTE: To prevent damage after moving, unpack your new portable air conditioner and let the machine stand upright for a minimum of 2 hours before operating.
Part 1: Placement
Place the air conditioner on a flat surface and near a power supply outlet at least 8 in. (20 cm.) away from any wall or object that could block the airflow (See below).
Socket wiring should be in accordance with the local electric safety requirements.
6
INSTALLATION
Part 2: Exhaust Hose Installation
The two exhaust duct connectors tighten on the ends of the exhaust duct (See Fig. 1).
Slide the square side of the exhaust duct connector into the opening at back of the air
conditioner (See Fig. 2 and Fig. 3).
The exhaust hose can extend up to approximately 59 in. (150 cm.).
Part 3: Window Seal Plate Installation
The window seal plate can be installed horizontally or vertically. The window seal plate can fit in windows with a minimum width of 23.5 in (60 cm.) and a maximum width of 59 in. (150 cm.).
Open the window and place the window seal plate on the inside edge of the window.
Adjust the window seal plate to the width of the window. Once secure, close the window.
Connect the oval side of the exhaust duct connector to the window seal plate.
7
PRODUCT OPERATION
BEFORE PLUGGING IN THE UNIT TO A POWER SOURCE:
1. Let the appliance stand upright for a minimum of 2 hours. This will reduce the chance of
malfunction in the cooling system.
2. Check to make sure the rubber drain plugs are securely plugged into the drain ports on the
back of the unit to prevent water leaks.
3. Check to make sure the exhaust hose has been installed properly (See Installation page 7).
4. Check to make sure that the air conditioner has been properly vented out the window (See
Installation page 7).
Conduct a Power Plug Check:
1. Press the RESET button on the power cord.
2. Plug the cord into an electrical outlet.
3. Press the TEST button on the power cord. The RESET button should pop up.
4. Press the RESET button for use.
5. Do not use the air conditioner if the test fails. The green light on the power cord will turn on if the plug is working properly.
Note: IF YOU TURN THE AIR CONDITIONER OFF AND IMMEDIATELY RESTART IT, ALLOW 3 MINUTES FOR THE COMPRESSOR TO RESTART COOLING. IN THE EVENT OF A POWER FAILURE, WAIT 3 MINUTES BEFORE RESTARTING THE UNIT.
ATTENTION: THE UNIT SOLD IN THE UNITED STATES IS SET TO FAHRENEHIT. THE UNIT SOLD IN CANADA IS SET TO CELSIUS.
8
PRODUCT OPERATION
Remote Control
All functions can be accessed from the remote control. A CR2025 battery is required for
operation. Battery is included.
Child Lock Function:
This button is on the remote control only. When pressed, this function locks the air conditioner into the mode it is currently in. When in lock mode you cannot change modes from the display or remote control until it is unlocked. Unlock by pressing the lock button again.
Touchscreen Control Panel
Icon Description
Press this icon to turn the machine on and off.
Press this icon to switch between operating modes: fan, sleep, auto, and cool.
Press this icon to lower the set temperature or 24-hour timer.
Press this icon to raise the set temperature or 24-hour timer. Long press this key for 5 seconds to show the current room temperature.
Press this icon to set the wind speed of the machine. First press sets high speed, second press sets low speed.
Press this icon to operate the timer. When the machine is on, use the timer to set time-off. When the machine is off, use the timer to set the time-on.
Press this icon to turn on the dehumidification mode.
Press this icon (swing) to turn on vertical oscillating air vent.
9
PRODUCT OPERATION
Boot State:
When you select a mode, the machine will enter boot state. The indicator light of the mode selected will blink for a few seconds to allow the machine to process the selection. Once the machine has processed the change, the indicator light will turn solid and the new mode will begin.
Fan Operation:
Press the mode icon to switch to fan mode. The machine will enter boot state, the indicator light will blink for a few seconds and turn solid when confirmed.
In fan mode, only the upper blower is on, while the compressor is off.
Press the wind speed icon to switch between high and low wind speeds.
Sleep Mode:
Press the mode icon to switch to sleep mode. The machine will enter boot state, the indicator light will blink for a few seconds and turn solid when confirmed.
Sleep mode is only valid when the air conditioner is in automatic mode or cooling mode.
In sleep mode the fan runs at low speed.
If sleep mode is selected while in cooling mode, the set temperature will increase by 1°F after
every 1 hour passed.
Auto Mode:
Press the mode icon to switch to automatic mode. The machine will enter boot state, the
indicator light will blink for a few seconds and turn solid when confirmed.
When the machine is powered on for the first time or if the machine has been off for more than 30 minutes, the machine enters automatic mode by default.
When switching to automatic mode from other modes or from powering on the air conditioner (first time or when off for over 30 minutes), the machine will automatically set to the following:
If room temperature is > 75°F (24°C) auto set to cooling mode
If room temperature is > 72°F (22°C) and < 75°F (24°C) auto set to fan mode
If room temperature is < 72°F (22°C) auto set to single cold type ventilation
Once in automatic mode, the room temperature will change, while the set mode will remain the
same. The set mode will not change until automatic mode is complete.
10