2
Parts - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3 Safety Precautions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4 Installation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5 Operation/Functions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6 Maintenance - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9 Troubleshooting - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10 Specifications - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11 Warranty - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 12
PORTABLE AIR CONDITIONER
Model ARP-904EC
TABLE OF CONTENTS
3
ARP-904EC
PARTS
Handle
Control panel
Evaporator Filter
Condenser
Air Outlet
Air Louvers
Rear Casters
Exhaust Air Outlet
Power Cord
Drain Port
Front Casters w/ Lock
Exhaust Air Hose
4
BEFORE USE
SAFETY PRECAUTIONS
1. Only use in the upright position on a flat, level surface at least 20”/50cm from any object.
2. Do not place objects on top or in front of the unit.
3. Closely supervise children and pets while unit is in use.
4. For indoor use only.
5. Turn off and unplug the unit when it is not in use.
6. Do not use in wet environments.
7. Do not pull the unit by the cord.
8. If the power cord is damaged, it must be replaced by an electrician to avoid hazard or injury.
FOR MAXIMUM EFFICENCY
1. Do not exceed the recommended room size of 300 sq. feet.
2. Keep doors and windows closed.
3. Keep curtains or blinds closed during the sunniest part of the day.
4. Keep filters clean.
5. Once room has reached the desired conditions, reduce the temperature
5
ARP-904EC
INSTALLATION
1. Connect the hose to the exhaust air outlet.
2. Insert the exhaust hose into the window spacer.
NOTE: The hose may be extended from 1-5 ft/300-1500mm but for maximum efficiency use the shortest length
possible. For best results do not let the exhaust hose exceed a 45° angle.
6
OPERATION/FUNCTIONS
CONTROL PANEL
1. Temperature/Hour LED Display
2. Power button
3. Power/Water Full indicator light
4. Temperature DOWN button
5. Temperature UP button
6. Mode button (Fan, Cool, Auto, Dry)
7. Fan indicator light
8. Cool indicator light
9. Auto indicator light
10. Dry indicator light (Dehumidifier)
11. Speed button (High, Medium, Low)
12. High indicator light
13. Medium indicator light
14. Low indicator light
15. Sleep button
16. Sleep indicator light
17. Oscillating button
18. Oscillating indicator light
19. Timer button (1-12 hours)
20. Timer indicator light
7
ARP-904EC
ON/OFF
Press this button to start and stop the unit.
MODE
Press this button to select the Fan, Cool, Auto or Dry (Dehumidifier) mode. The Fan mode will allow you to select a Speed of High, medium or Low. The Cool mode will allow you to select a Speed of High, Medium or Low or a specific temperature by using the UP/DOWN buttons. The Auto mode will automatically adjust the settings between Fan (High, Low and Medium) and Cool (High, Low and Medium) depending on the current temperature in the room. Press the Auto button and then use the UP/DOWN button to select your desired temperature. If the temperature in the room is at 73°F and above the COOL mode and SPEED will automatically be selected to keep the room at the desired temperature. If the temperature in the room is between 68°F ­73°F the FAN mode and SPEED will automatically be selected to keep the room at the desired temperature. The Dry mode will allow you to dehumidify the room and remove excess moisture.
SPEED
Press the SPEED button to select a High, Medium or Low setting.
TIMER (1-12 Hours)
The timer button will allow you to turn the unit ON or OFF without even being in the room. If the unit is off- Press the TIMER button (Timer indicator light will be lit). Continue pressing the TIMER button until you
select the quantity of hours (1-12) you want the unit turned on in. Example- If you want the unit to turn on in 3 hours then Press the button until it shows 3, the unit will automatically turn on in 3 hours.
If the unit is on- Press the TIMER button (Timer indicator light will be lit). Continue pressing the TIMER button until you select the quantity of hours (1-12) you want the unit turned off in. Example- If you want the unit to turn off after 4 hours then press the button until it shows 4, the unit will automatically turn off in 4 hours.
8
SLEEP
By pressing the SLEEP button, the set temperature will increase 2°F / 1°C in the first hour, another 2°F / 1°C in the second hour and then remains at that temperature.
WATER FULL
When the water tank is full the POWER/WATER FULL light will light up and you will hear a beeping noise. At this point you must empty it out by placing a container underneath the drain port, remove the rubber drain plug and then water will flow out until it is empty.
OSC (OSCILLATING) FEATURE
This feature allows the air to flow in all directions. Press the Oscillating button (OSC indicator will be lit). The air louvers will begin oscillating. Press the OSC button again to turn it off.
REMOTE CONTROL
A - Timer button B - Fan button C - Mode button D - Sleep button E - Oscillating button F - ON/OFF button G - Temperature UP button H - Temperature DOWN button
Loading...