Royal Prestige FP6000CT, FP6000UC, FrescaPure6000 Use & Care Manual

Page 1
IMPORTANT: Read and Save these Instructions.
Questions or Comments: 1-800-279-3373 8am- 5pm Central Standard Time
USE & CARE MANUAL
WATER FILTRATION SYSTEMS
MODELS FP6000CT/FP6000UC
Page 2
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
IMPORTANT USE GUIDELINES . . . . . . . . . . . . . . . . . . . . . 1
DRINKING WATER SYSTEM SPECIFICATIONS . . . . . . . . . . . . . 3
REPLACEMENT PARTS DIRECTORY . . . . . . . . . . . . . . . . . . 4
GETTING STARTED . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
INSTALLATION: COUNTERTOP SYSTEM
(Model: FP6000CT) . . . . . . . 5
REPLACING THE CARTRIDGE: COUNTERTOP SYSTEM . . . . . . . . 6
INSTALLATION: UNDER-COUNTER SYSTEM
(Model: FP6000UC) . . . . . 9
DRILLING A HOLE IN A STAINLESS STEEL SINK . . . . . . . . . . . . . . 10
DRILLING A HOLE IN A PORCELAIN/CERAMIC SINK . . . . . . . . . . . 11
FAUCET INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . 12
SYSTEM INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . 13
REPLACING THE CARTRIDGE: UNDER-COUNTER SYSTEM . . . . . . 15
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . 18
WARRANTY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
TABLE OF CONTENTS
WHAT’S IN THE BOX
FRESCAPURE™ COUNTERTOP
SYSTEM (MODEL: FP6000CT)
FRESCAPURE™ UNDER-COUNTER
SYSTEM (MODEL: FP6000UC)
Page 3
FRESCAPURE1
INTRODUCTION
Congratulations on the purchase of your new FrescaPure™ Drinking Water System! You have taken an important step toward improving the quality of
your drinking and cooking water. This System will serve you reliably for many years to come when operated
and maintained according to the instructions in this manual. You have made a wise investment. Now, please take a few additional minutes to complete reading this manual, so that you may realize all the benefits your new FrescaPure
Drinking Water System has to offer!
IMPORTANT USE GUIDELINES
1. Read this manual completely before attempting to install or use this product.
2. Actual capacity of your System may vary from the rated capacity. This may
be due to the volume of contaminants actually present in your water supply. To insure best results, replace Filter Cartridge when the first of the following occurs:
– Annually – When the Display begins flashing RED (indicating the rated capacity
has been reached) – When the flow rate diminishes – When you notice a taste or odor recurrence
3. Do not use with water that is microbiologically unsafe or of unknown
quality without adequate disinfection before or after the System.
4. Systems certified for cyst reduction may be used with disinfected water
that may contain filterable cysts.
5. Individuals requiring specific microbiological purity should consult their
physician.
6. This System is not intended to convert waste water or raw sewage into
drinking water.
7. DO NOT mistake Red Collars and Tubes as a “hot” water feed line. This
system is for use on cold potable water supplies only. Color coding is only to insure proper connections to the System “Inlet” and “Outlet” ports.
8. For this System to continue to perform as tested and represented, use only
Genuine, WQA Certified, Royal Prestige Filter Cartridges.
9. Genuine, Royal Prestige Filter Cartridges may be purchased from your
Independent Royal Prestige Representative. For additional purchase information, please contact the Royal Prestige Customer Service Center at:
1-800-279-3373.
Page 4
2 FRESCAPURE
10. After set-up and installation, DO NOT remove the Battery Shuttle except
when replacing the Filter Cartridge. Removing the Battery Shuttle prematurely may result in a loss of stored data.
11. Be sure to replace the Battery Shuttle each time a new Filter Cartridge is
installed. For your convenience, a new Battery Shuttle is included with the purchase of each new, replacement Filter Cartridge.
12. Do not allow System to sit for extended lengths of time without being
used (10 days or more). If System must be left unused for more than 10 days, drain all water from the System and use sanitary gloves to remove the Filter Cartridge. Place Cartridge into clean plastic bag, seal and refrigerate. Once you return, re-install the Cartridge per the Replacement Instructions and continue to use.
13. This System must be protected from freezing. Failure to do so may result
in loss of performance, damage to the parts and water leakage. If System will be exposed to freezing temperatures, drain water from Housing and remove the Filter Cartridge.
14. The FP6000UC Under-Counter System is designed to work only with the
special vented faucet provided. Use with a standard non-vented faucet may cause the System to malfunction and will void your warranty.
15. Installation of this product must comply with all state and local laws and
regulations. Refer to your local agencies for details.
Page 5
FRESCAPURE3
See included performance data sheet for individual contaminants and reduction performance.
COUNTERTOP SYSTEM (MODEL: FP6000CT)
Installation ...............................................Countertop
Rated Capacity.....................................750 Gallons (2,839 L)
Replacement Filter Cartridge....................................WF0705
Monitor................................................Electronic LED
Rated Service Flow @ 60 psi ......................0.75 Gal/min (2.84 L/min)
Housing Construction ..........................316 Surgical Stainless Steel
Lid Construction.......................................High Impact ABS
Maximum Working Pressure ..........................100 psig (689.5 kPa )
Minimum Working Pressure ............................30 psig (206.8 kPa)
Maximum Operating Temperature
(for cold water use only) ..........100º F/38º C
Minimum Operating Temperature ..............................40º F/4º C
Particle Retention Size ........................20 Nanometers (0.02 micron)
EPA Establishment Number................................63018-NV-001
UNDER-COUNTER SYSTEM (MODEL: FP6000UC)
Installation ............................................ Under-Counter
Rated Capacity.....................................750 Gallons (2,839 L)
Replacement Filter Cartridge....................................WF0705
Monitor................................................Electronic LED
Rated Service Flow @ 60 psi ......................0.75 Gal/min (2.84 L/min)
Housing Construction ..........................316 Surgical Stainless Steel
Lid Construction.......................................High Impact ABS
Maximum Working Pressure ..........................100 psig (689.5kPa )
Minimum Working Pressure .............................30 psig (206.8kPa)
Maximum Operating Temperature
(for cold water use only) ..........100º F/38º C
Minimum Operating Temperature ..............................40º F/4º C
Particle Retention Size ........................20 Nanometers (0.02 micron)
EPA Establishment Number................................63018-NV-001
DRINKING WATER SYSTEM SPECIFICATIONS
Patent Pending
Patent Pending
System Tested and Certified by WQA against NSF/ANSI 42 (Aesthetics) for the reduction of Chlorine Taste and Odor, Chloramine and Particulate Class 1; NSF/ANSI 53 for the reduction of Cysts, Turbidity, VOCs and MTBE; NSF P231 for Microbiological Water Purifier based on the recommendations set forth in the USEPA Guide Standard and Protocol for Microbiological Water Purifiers for the reduction of Bacteria, Viruses and Cysts.
Page 6
4 FRESCAPURE
ITEM PART NUMBER DESCRIPTION
1 RP6150 Enclosure Cover
(with LED Display)
2 RP6152 Housing Lid 3 RP6153 Gasket 4 RP6154 Housing Clamp
(includes Knob & T-Bolt)
5 RP6155 Stainless Steel Filter Housing 6 RP6151 Enclosure 7 RP6156 Diverter Valve Assembly 8 RP0160 Faucet Adapter Kit
(3 pieces)
9 RP6157 Collar Release Tool 10 RP6158 Battery Cover 11 RP4547 Battery Shuttle
(includes Battery)
12 RP6159 Flow Monitor
(includes Battery & Shuttle)
13 WF0705 Filter Cartridge
ITEM PART NUMBER DESCRIPTION
1 RP6152 Housing Lid 2 RP6153 Gasket 3 RP6154 Housing Clamp
(includes Knob & T-Bolt)
4 RP6155 Stainless Steel Filter Housing 5 RP6160 Base 6 RP6161 Faucet Kit
(includes)
:
7 - -
Dedicated Water Faucet 8 - - Monitored Beauty Ring 9 - - Rubber Washer 10 - - C Washer 11 - - Nut 12 RP6162 T-Valve 13 RP4547 Battery Shuttle
(includes Battery)
14 RP6159 Flow Monitor
(includes Battery & Shuttle)
15 RP6157 Collar Release Tool 16 WF0705 Filter Cartridge
REPLACEMENT PARTS DIRECTORY
Components that are included with this System are capitalized throughout this
manual to distinguish between System Components and existing plumbing connections.
NOTE
1
2
3
4
5
6
7
8
9
11
10
12
13
9
1
2
3
4
5
14
13
15
12
16
7
8
9 10 11
FRESCAPURE™ COUNTERTOP SYSTEM (Model: FP6000CT)
FRESCAPURE™ UNDER-COUNTER SYSTEM (Model: FP6000UC)
Page 7
INSTALLATION: COUNTERTOP SYSTEM (Model: FP6000CT)
1. Unthread and remove the aerator from the
end of your kitchen faucet if it has one.
2. Thread the Diverter Valve directly onto your
kitchen faucet. Do NOT over-tighten.
3. If the threads to the Diverter Valve do not
directly attach to your kitchen faucet, use one of the three Adapters provided.
4. Most kitchen faucets with external threads will
directly attach to the Diverter Valve. In some instances the Diverter Valve may be smaller than your kitchen faucet. In this case use the Adapter with internal threads and thread it directly to your kitchen faucet. Next, thread the Diverter Valve to the Adapter.
5. If your kitchen faucet has internal threads,
thread one of the two Adapters with external threads directly to your kitchen faucet. Next, thread the Diverter Valve to the Adapter.
6. If your kitchen faucet does not have threads,
measure the inside diameter of your faucet and provide this information to your Independent Royal Prestige Representative or to the Royal Prestige Customer Service Center (1-800-279-3373). Be sure to request
an Expandable Adapter.
7. If your kitchen faucet does not fit any of the
Adapters provided, send your threaded aerator to your Independent Royal Prestige Representative or to the Royal Prestige Customer Service Department. Include a note
requesting an adapter that fits your threads.
FRESCAPURE5
GETTING STARTED
1. Determine which model you have.
2. Open the shipping carton, remove all FrescaPure
Drinking Water System
parts and place them on your kitchen counter.
3. Compare them with the parts shown on the “What’s In the Box” section on
the inside front cover to familiarize yourself with the System.
4. Follow the instructions for the FrescaPure
model that you have.
1
2
3
4
5
Page 8
6 FRESCAPURE
8. Push the Blue and Red Tube ends on Diverter
Valve Assembly into Blue “Outlet” and Red “Inlet” Collars located on the back of System Enclosure. Lightly tug on Tubes to insure they are securely connected.
9. Position the System next to your sink. Turn
the cold water “ON”, and turn the Lever on Diverter Valve “UPWARD”. Water will begin filling the System. Upon initial start-up, the Display will begin blinking GREEN, YELLOW and RED five (5) times before continuing to blink GREEN, indicating peak operational performance.
Check that all hose, clamp and
housing connections are tight and do not leak.
10.
When using the System for the first time, or whenever a new Filter Cartridge is installed, allow the System to flush into the sink for fifteen (15) minutes. This will expel trapped air and condition the Cartridge for normal use.
(This water may be used to water your plants.)
CONGRATULATIONS! Your new FrescaPure
System is ready for use!
REPLACING THE FILTER CARTRIDGE: COUNTERTOP SYSTEM
The most important part of maintaining your FrescaPure™ Drinking Water System is replacing the Cartridge on a regular service interval. To insure best results, the Cartridge should be replaced upon the first occurrence of one of the following conditions:
– Annually – When the Display begins flashing RED (indicating the rated capacity
has been reached)
– When the flow rate diminishes – When you notice a taste or odor recurrence
1.
Place a towel or other soft cloth in sink.
2. With Faucet “OFF”, lightly depress back of
Enclosure Cover and lift upward to remove. Set Cover on counter. It is not necessary to
disconnect the black Monitor Cable that is attached to the Cover.
Insist on Genuine, WQA Certified, Royal Prestige Filter Cartridges. Only Genuine, Royal Prestige Cartridges have been tested and certified by the Water Quality Association to insure the performance represented in the Performance Data Sheet. Failure to use Royal Prestige Filter Cartridges and replacement components
will invalidate your warranty.
IMPORTANT
9
2
8
Red Blue
Page 9
FRESCAPURE7
3. Depress the Red “Inlet” Collar on Lid while
pulling Fitting upward to remove. Repeat this procedure to remove fitting from Blue “Outlet” Collar.
4. Grasp Clamp and lift upward to remove Filter
Housing from Enclosure. Set Filter Housing on towel in base of sink.
5. Turn Knob counterclockwise to loosen Clamp.
Push Knob forward to unlatch T-Bolt from Clamp. Once Clamp is removed, lift Lid
upwa
rd.
This step will expose the Filter Cartridge.
6. While holding Lid, turn Cartridge counter-
clockwise to remove.
Wrap in newspaper
and discard with normal refuse.
7. Wash the inside of the Housing and Lid with
warm water and a mild dishwashing detergent. Rinse well and dry with a clean cloth.
8. Remove the sanitary plastic wrap from the
new Filter Cartridge. Thread the new Cartridge clockwise onto Lid until you feel resistance. Make an additional quarter turn.
DO NOT over-tighten.
9. Make certain Gasket is firmly seated onto Lid.
With new Cartridge connected to Lid, lower Cartridge into Housing and align with Housing.
10. Place Clamp around Lid and Housing. Push
Knob forward to latch T-Bolt. Tighten Knob.
RECOMMENDATION
Rubber gloves should be worn to avoid direct contact with contaminants removed by this System.
ONLY REMOVE BATTERY SHUTTLE
AT TIME OF CARTRIDGE REPLACEMENT. Removing Battery Shuttle prematurely may result in a loss of stored data. A new Battery Shuttle is included with
every Genuine, WQA Certified, Royal Prestige Filter Cartridge.
IMPORTANT
CAUTION
Do not use abrasive pads or abrasive cleaners (including cleaners containing bleach) as this will result in scratching and damage to your System.
NOTE
To release Tubing Fittings from Collars, a Collar
Release Tool has been provided for your convenience.
4
6
10
5A
5B
3
Collar Release Tool
9A
9B
Gasket
Page 10
11. To access the Battery Shuttle, slide Battery
Cover upward and set on counter. Remove old Battery Shuttle from Monitor and discard. Insert new Battery Shuttle and re-install the Battery Cover.
12. Orient Tubing and Monitor Cable in Enclosure
so that the Filter Housing can be lowered into the Enclosure without interference.
13. As you lower the Filter Housing into the
Enclosure, be certain to orient the Knob towards the back of the Enclosure.
14. Push the Blue Tubing end into Blue “Outlet”
Collar located on Lid. Push the Red Tubing end into Red “Inlet” Collar located on Lid. Tug both Tubes lightly to insure they are securely in place.
15. Tuck the Monitor Cable inside the Enclosure.
Hinge Cover to front of Enclosure as shown, then press rear portion of Cover into place. Position the System next to your sink.
16. Slowly turn the cold water “ON” and turn
the Lever on Diverter Valve “UPWARD”. Water will begin filling the System. Upon initial start-up, the Display will begin blinking GREEN, YELLOW and RED five (5) times before continuing to blink GREEN, indicating peak operational performance. Check that all hose, clamp and housing connections are tight and do not leak.
17. When using your System for the first time,
or whenever a new Cartridge is installed, allow the System to flush into the sink for fifteen (15) minutes. This will expel trapped air and condition the Filter Cartridge for normal use. (This water may be used to water
your plants.)
8 FRESCAPURE
11A
15A
15B
11B
14
16
12
13
Battery Cover
Page 11
INSTALLATION: UNDER-COUNTER SYSTEM (Model: FP6000UC)
If your sink has an existing hole at least 1” in diameter that is being used for a spray attachment or soap dispenser, you may decide to remove it and use the existing hole to continue your installation. (Skip the next section and
go to “Faucet Installation” on page 12.)
If your sink DOES NOT have an existing hole at least 1” in diameter, a new hole will need to be drilled.
The type of plumbing that you have in your home will determine the method of installation and the type of hardware to be used. Below is a list of common tools required for most under-counter installations:
Drilling a Hole in a Porcelain/Ceramic Sink:
- 3/8” Variable-Speed Electric Drill
- Relton
1” Porcelain Cutter Kit (PC-16)
(Visit www.relton.com for purchase information.)
- Masking Tape
Drilling a Hole in a Stainless Steel Sink:
- 3/8” Variable-Speed Electric Drill
- 1/8” Drill Bit
- 1” Hole Saw
- Masking Tape
- Hammer
- Punch
Installing the T-Valve and Dedicated Drinking Water Faucet:
- 5/8” and 3/4” Open End Wrenchs or Adjustable Wrench
- Tubing Cutter or sharp Utility Knife
CAUTION
Using power tools near water may result in electrical shock or even death. Be certain that sink area is dry prior to using any power tool.
If you are experienced in this type of installation and choose to install
yourself, please proceed with extreme caution. If you have any doubts about doing
this yourself, please consult a licensed plumber.
The Universal Plumbing Code, and other state and county codes prohibit the use of saddle valves. We also do not recommend their use. You must adhere to your state and local plumbing codes. If you are uncertain, consult a licensed plumber.
IMPORTANT
WARNING
FRESCAPURE9
Relton™ Porcelain Cutter
Kit includes:
Carbide-Tipped Pilot Drill
Spring-Loaded Porcelain Saw
Finish Hole Saw
Page 12
10 FRESCAPURE
TYPICAL UNDER-COUNTER SYSTEM INSTALLATION
DRILLING A HOLE IN A STAINLESS STEEL SINK:
1. Locate an area on your sink to install the
Dedicated Drinking Water Faucet. (Make certain there are no support ribs under the sink in that area.) Cover the designated location
for the faucet installation on sink with masking tape. Use the punch and hammer to make a light indentation at the designated faucet installation location.
2. Using a 1/8” high speed drill bit, drill a pilot
hole in the sink.
3. Use a 1” hole saw to enlarge the pilot hole
to final size.
This type of sink can be scratched very easily. Use extreme care.
If you have any doubts about doing this yourself, consult a licensed plumber.
CAUTION
2 3
1
Dedicated
Drinking Water
Faucet
Monitor
Filter
Housing
RED
Tubing
WHITE Tubing
T-Valve
BLUE
Tubing
Cable
Hot
Cold
Page 13
FRESCAPURE11
DRILLING A HOLE IN A PORCELAIN/CERAMIC SINK:
1. Locate an area on your sink to install the
Dedicated Drinking Water Faucet. (Make certain there are no support ribs under the sink in that area.) Cover the designated location for the
Faucet installation on sink with masking tape.
2. Using the carbide-tipped pilot drill supplied
with the Relton Cutter Kit and a variable speed drill, slowly drill a pilot hole completely through the porcelain or enamel and metal base material.
3. The plastic sleeve supplied on the pilot drill is
to be positioned against the drill chuck after the pilot drill has been inserted. This prevents the drill chuck from contacting the porcelain after the pilot hole has been completed.
4. Change to the spring-loaded porcelain saw
bit. Be sure the pilot guide supplied is inserted tightly into the porcelain saw. With light pressure applied to the porcelain saw, start the drill motor turning as slowly as possible; after the initial cut has started in the porcelain, the drill motor’s R.P.M. may be increased. (Avoid
high R.P.M.s during the initial penetration of the porcelain.) Three to four minutes may
be necessary to cut the porcelain; a faster penetration rate could result in excessive chipping. Continue drilling until a complete ring has been cut through to the metal base.
5. Change to the finish hole saw bit. Be sure the
pilot guide is inserted tightly. Begin to cut with slow speed and light pressure until porcelain
(inside the ring cut by porcelain saw in Step 4)
has been penetrated to the metal underneath. At that point, remove the hole saw from the hole and clean all chips from the porcelain surface. Reinsert the hole saw into the hole and cut through the remaining material.
CAUTION
This type of sink can chip very easily. If you have any doubts about doing
this yourself, consult a licensed plumber.
RECOMMENDATION
Experiment on discarded porcelain to familiarize yourself with the action and performance of the porcelain cutter kit.
3
4A
2A
5A
1
4B
2B
5B
Plastic Sleeve
Page 14
12 FRESCAPURE
IMPORTANT
FAUCET INSTALLATION:
1.
Slide the Monitored Beauty Ring through the
Red, White and Blue Tube ends and onto the Faucet Stem.
2. Insert the Red, White and Blue Tube ends
(including the Monitor Cable) through the hole in sink. Insert Faucet shank into hole.
3. From under the sink, insert the Red, White
and Blue Tube ends (including the Monitor Cable) through Rubber Washer and slide
firmly onto Faucet Stem.
4. Insert the Red, White and Blue Tube ends
through Nut and thread Nut onto Faucet Stem. Insert the C Washer between Nut and Rubber Washer, and hand tighten. Align Monitored Beauty Ring to face the front of Dedicated Drinking Water Faucet before using 1” or adjustable wrench to tighten Nut.
RECOMMENDATION
When tightening Nut, two people may be required to insure proper alignment of Faucet and Monitored Beauty Ring.
DO NOT slide the Monitor Cable
through Nut.
1
2
3
4A
4B
Rubber Washer
C Washer Nut
Page 15
FRESCAPURE13
SYSTEM INSTALLATION:
Read these instructions completely before starting System Installation.
Make a determination whether you will be able to make a “Typical” installation (as shown in the illustration on page 10) after looking at your under-sink cabinet area.
If the configuration of your under-sink area does not permit a “Typical” installation, it will be necessary to develop one of your own. Be sure to take into consideration where the System will be permanently located in relationship to the cold water supply line and Dedicated Drinking Water Faucet. Make generous allowances for estimating the Tubing lengths required to make these connections. (Two Velcro Strips have been provided should you
decide to mount the Monitor to the cabinet wall.)
1. Before starting this installation, be certain to
turn “OFF” the cold water supply located under your sink. If a shut-off valve is not located on the cold water supply line, shut off the main water supply to your home.
2. Locate an area under sink to place the Base.
The Base should be located directly under the area where the Dedicated Drinking Water Faucet is installed.
3. Locate the shut-off valve on the existing cold
water supply line. Using a 5/8” open ended wrench, unthread compression nut located on top of the shut-off valve by turning the wrench counterclockwise.
4. Thread the T-Valve onto shut-off valve using
a 3/4” wrench to tighten, then thread compression nut onto T-Valve using 5/8” wrench to tighten (clockwise).
5. Before pushing the White Tubing (which is
attached to the Dedicated Drinking Water Faucet) into the “Outlet” Collar located on
T-Valve, determine whether it is necessary to shorten Tubing. If so, shorten to desired length before inserting.
4
3
5
WARNING
DO NOT use copper tubing with the Collars installed on this System. Although it may appear that copper tubing will fit, water leaks will develop over time. If copper tubing is required, you must use copper compression fittings that must be purchased separately and adapted accordingly.
Page 16
14 FRESCAPURE
6. Cut a 6 in. length from the 5 ft. of Blue Tubing
provided. Take this short piece of Blue Tubing and insert one end into the Blue “Outlet” Collar on Lid. Take the remaining Blue Tube end and push it into the “Inlet” Collar on Monitor.
7. Before pushing the Blue Tubing (which is
attached to the Dedicated Drinking Water Faucet) into the “Outlet” Collar on Monitor,
determine whether it is necessary to shorten Tubing. If so, shorten to desired length before inserting.
8. Before pushing the Red Tubing (which is
attached to the Dedicated Drinking Water Faucet) into the Red “Outlet” Collar on Lid,
determine whether it will be necessary to shorten Tubing. If so, shorten to desired length before inserting.
9. Insert Monitor Cable Connector into Cable
Port located on Monitor.
10. Slowly turn cold water supply “ON” and
turn the Lever on Dedicated Drinking Water Faucet downward. Water will begin filling the System. Upon initial startup, the Monitored Beauty Ring will begin blinking GREEN, YELLOW and RED five (5) times before continuing to blink GREEN, indicating peak operational performance. Check that all hose, clamp and Housing connections are tight and do not leak.
11. When using your System for the first time, or
whenever a new Cartridge is installed, allow the System to flush into the sink for fifteen (15) minutes. This will expel trapped air and condition the Filter Cartridge for normal use.
(This water may be used to water your plants.)
CONGRATULATIONS! Your new FrescaPure
System is now ready for use!
Give all Tubes a gentle tug at the point where they make a connection. This will insure they are firmly seated and will not come out.
IMPORTANT
7
8
9
10
6A 6B
Blue
Red
Blue Tubing from Faucet
Monitor
Page 17
FRESCAPURE15
REPLACING THE FILTER CARTRIDGE: UNDER-COUNTER SYSTEM
The most important part of maintaining your new FrescaPure™ Drinking Water System is replacing the Cartridge on a regular interval. To insure best results, the Cartridge should be replaced upon the first occurrence of the following conditions:
– Annually – When the Monitored Beauty Ring begins flashing RED
(indicating the rated capacity has been reached) – When the flow rate diminishes – When you notice a taste or odor recurrence
1. Turn “OFF” the cold water supply. Using
the Tool provided, depress Red Collar on Lid, while pulling upward on the Red Tubing at the same time. Repeat this procedure to remove the Blue Tubing from Lid.
2. Place System in sink. Turn Knob counter-
clockwise to loosen Clamp. Press Knob forward to unlatch T-Bolt from Clamp. Once Clamp is removed, lift Lid upward. This step will expose the Filter Cartridge.
3. While holding Lid, turn Cartridge counter-
clockwise to remove. Wrap in newspaper and discard with normal refuse.
4. Wash inside of Housing and Lid with warm
water and a mild dishwashing detergent. Rinse well and dry with a clean cloth.
Rubber gloves should be worn
to avoid contact with contaminants removed by System.
RECOMMENDATION
CAUTION
Do not use abrasive pads or abrasive cleaners (including cleaners containing bleach) as this will result in scratching and damage to your System.
Insist on Genuine, WQA Certified, Royal Prestige Filter Cartridges. Only Genuine, Royal Prestige Cartridges have been tested and certified by the Water Quality Association to insure the performance represented in the Performance Data Sheet. Failure to use Royal Prestige Filter Cartridges and replacement components
will invalidate your warranty.
IMPORTANT
3
2A
2B
NOTE
To release Tubing Fittings from Collars, a Collar
Release Tool has been provided for your convenience.
1
Collar Release Tool
Page 18
5. Remove sanitary plastic wrap from the new
Filter Cartridge. Thread new Cartridge clockwise onto Lid until you feel resistance. Make an additional quarter turn. DO NOT
over-tighten.
6. Make certain Gasket is firmly seated onto
Lid. With new Cartridge connected to Lid, lower Cartridge into Housing and align Lid with Housing.
7. Place Clamp around Lid and Housing. Push
Knob forward to latch T-Bolt. Tighten Knob.
8. Push the Blue Tube end into Blue “Outlet”
Collar located on Lid. Push the Red Tube end into Red “Inlet” Collar located on Lid. Tug both Tubes lightly to insure they are securely in place. Re-position System under sink.
9. Remove Battery Shuttle from Monitor and
discard. Insert new Battery Shuttle.
10. Slowly turn cold water supply “ON” and turn
the Lever on Dedicated Drinking Water Faucet downward. Water will begin filling the System. Upon initial startup, the Monitored Beauty Ring will begin blinking GREEN, YELLOW and RED five (5) times before continuing to blink GREEN, indicating peak operational performance. Check that all hose, clamp and housing connections are tight and do not leak.
11. When using your System for the first time, or
whenever a new Cartridge is installed, allow the System to flush into the sink for fifteen (15) minutes. This will expel trapped air and condition Filter Cartridge for normal use.
(This water may be used to water your plants.)
16 FRESCAPURE
ONLY REMOVE BATTERY SHUTTLE AT TIME OF CARTRIDGE REPLACEMENT. Removing
Battery Shuttle prematurely may result in a loss of stored data. A new Battery and Battery Shuttle is
included with every Genuine, WQA Certified, Royal Prestige Filter Cartridge.
IMPORTANT
5
7
8
9
6B
Gasket
6A
10
RedBlue
Monitor
Page 19
FRESCAPURE17
NOTES
Page 20
18 FRESCAPURE
TROUBLESHOOTING
CONDITION: Water continues to run from the Dedicated Drinking Water Faucet even after turning the water “OFF”.
REASON: The Dedicated Drinking Water Faucet does not shut off like a standard faucet. It has a valve that shuts off pressure in front of the System, and like a garden hose, the residual pressure will take time to drain.
SOLUTION: This condition is normal and no action is required. However, to minimize the “run on” effect, follow the flushing instructions for a minimum of 15 minutes when your System is new and each time a new Filter Cartridge is installed.
CONDITION: Water is flowing slowly from the System, yet the Monitored Beauty Ring is still flashing GREEN.
REASON: Excessive amounts of particles in the water supply may have caused premature plugging of the Filter Cartridge.
SOLUTION: The Cartridge and Battery Shuttle must be replaced due to poor water conditions in your area.
CONDITION: White sediment is in my filtered water.
REASON: There is a presence of calcium carbonate in your main
water supply. This will occur any time the filter water is boiled or frozen and then melts.
SOLUTION: This condition is normal and no action is required
CONDITION: The YELLOW lamp on the Monitored Beauty Ring
is flashing.
REASON: The Cartridge is reaching the end of its rated capacity and will need to be replaced soon. Order a Genuine, WQA Certified, Royal Prestige Filter Cartridge now so that you will have it when the RED lamp begins flashing, signaling it is time to replace the Cartridge.
SOLUTION: Replace Cartridge and Battery Shuttle when RED lamp on Monitored Beauty Ring begins flashing.
Page 21
FRESCAPURE19
TROUBLESHOOTING
CONDITION: Water is leaking between a tube or fitting and a Collar.
REASON #1: The tube or fitting is not completely inserted into Collar.
SOLUTION: Press tube/fitting firmly into Collar.
REASON #2: Tube end has been damaged, elongated or not cut
squarely.
SOLUTION: Depress Collar using the Tool provided and pull Tube at the same time to remove. Observe the end of the tube to determine condition. Cut a short section of the tube end off to correct condition. Re-install Tube into Collar by pressing firmly into place.
Page 22
Exclusively distributed by:
HY CITE ENTERPRISES, LLC
333 Holtzman Road, Madison, WI 53713
www.RoyalPrestige.com
© Hy Cite Enterprises, LLC • Printed in USA
Reproduction of this printed material is prohibited.
Due to continuing product development and research, final specification and/or appearance may vary.
R13.02 1-400-0118
LIMITED WARRANTY
for Royal Prestige® Brand Products
Hy Cite Enterprises, LLC (“Hy Cite”) provides the following warranties on its product line to the original consumer owner of the product, whether obtained by purchase or by gift. The following warranties may be transferred to immediate family members.
Water Treatment Systems: Hy Cite warrants that the base assembly, housing and spout assembly of your FrescaPure
Water Treatment Systems will be free from defects in material and workmanship for 15 years from the date of purchase. Hy Cite also warrants that your Water Treatment Systems cartridges will not become clogged for 90 days from the date of purchase. Electrical parts are warranted to be free from defects in material and workmanship for 1 year from date of purchase.
Note: Maintenance parts for your Water Treatment Systems (including diverter valve and hose assembly, and rubber o-rings) may need replacement, not because of defects, but because hard-water minerals may clog valves; and harsh chemicals in tap water can cause rubber o-rings and hoses to become brittle. Maintenance parts may be replaced at one-half (50%) of the current retail price during the 15 year warranty period.
Limitations on Coverage: The Hy Cite warranties cover only normal household use, meaning, for example, the warranties shall be void if your covered product has been damaged by neglect or improper assembly, maintenance, or servicing, or repair by unauthorized persons or used for commercial purposes.
Implied Warranties: ANY IMPLIED WARRANTIES WHICH THE PURCHASER MA
Y HAVE ARE LIMITED IN DURATION TO THE SAME DURATION AS THE WRITTEN WARRANTY DESCRIBED ABOVE FOR YOUR COVERED PRODUCT. Some states do not allow limitations on how long an implied warranty lasts, accordingly, the above limitation may not apply to you.
Warranty Performance: Should your covered product not comply with our warranty, return it to Hy Cite postage prepaid and Hy Cite will, at its option, either repair or replace the product. Hy Cite may replace the product with any equivalent product or with a product incorporating a new technology or design.
Return of Product: To obtain warranty service, return the product to our Service Center:
Hy Cite Enterprises, LLC
Royal Prestige Service Center
2115 Pinehurst Drive
Middleton, WI 53562
1-800-279-3373
Damage in Shipment: Hy Cite will replace any cover
ed product damaged in shipment free of charge if you notify Hy Cite within 30 days after your receipt of the product. Simply contact the Royal Prestige Service Center. As a condition to replacement, Hy Cite may require you to make the damaged product available for pick-up at Hy Cite’s expense.
Purchase Option: If your covered product is damaged by fire or storm, or is stolen, you may purchase new replacement product at one-half (50%) of current retail price. A valid police or fire report is required for discounted purchase.
Limitation of Remedies: No representative or other person is authorized to assume for Hy Cite any other liability in connection with the sale of covered products. Repair or replacement, at Hy Cite’s option, shall be your remedy under this warranty and in no event shall Hy Cite be liable for any incidental or consequential damages, losses or expenses. Some states do not allow the exclusion or limitation of incidental or consequential damages, accordingly, the above limitation or exclusion may not apply to you.
Legal Rights: This warranty gives you specific legal rights, and you may also have other rights which vary from State to State.
For more information on Hy Cite’s Royal Prestige brand products, visit our web site: www.royalprestige.com
Legal.388v19
Loading...