USE & CARE MANUAL
System Tested and Certified by NSF International against NSF/ANSI Standard 42 for the reduction of Chlorine Taste and Odor, nominal particulate Class I and NSF/ANSI Standard 53 for Cysts, Lead, VOC, Turbidity and MTBE.
See performance data sheet for individual contaminants and reduction performance.
Questions or Comments: 1-800-279-3373 8am-5pm Central Standard Time
IMPORTANT: Read and Save these Instructions
TABLE OF CONTENTS
INTRODUCTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
IMPORTANT USE GUIDELINES . . . . . . . . . . . . . . . . . . . . 1
MODEL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . 3
REPLACEMENT PARTS DIRECTORY . . . . . . . . . . . . . . . . 4
GETTING STARTED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
COUNTER-TOP INSTALLATIONS (FP5000 & FP4000) . . . . 5
REPLACING THE CARTRIDGE . . . . . . . . . . . . . . . . . . . . 6
FILTER LIFE INDICATOR . . . . . . . . . . . . . . . . . . . . . . . . 8
UNDER-COUNTER INSTALLATION (FP4500). . . . . . . . . . 8
DRILLING A HOLE IN A PORCELAIN/CERAMIC SINK . . . 9
DRILLING A HOLE IN A STAINLESS STEEL SINK . . . . . . 10
FAUCET INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . 10
INSTALLING THE SYSTEM. . . . . . . . . . . . . . . . . . . . . . 10
REPLACING THE CARTRIDGE . . . . . . . . . . . . . . . . . . . 12
FILTER LIFE INDICATOR . . . . . . . . . . . . . . . . . . . . . . . 13
TROUBLESHOOTING. . . . . . . . . . . . . . . . . . . . . . . . . . . 14
WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
INTRODUCTION
Congratulations…
on the purchase of your new FrescaPure™ Drinking Water System!
You have taken an important step toward improving the quality of your drinking and cooking water.
This System will serve you reliably for many years to come when operated and maintained according to the instructions in this manual.
You have made a wise investment. Now, please take a few additional minutes to complete reading this manual, so that you may realize all the benefits your new FrescaPure™ Drinking Water System has to offer!
IMPORTANT USE GUIDELINES
1. “Genuine Royal Prestige NSF Certified Replacement Car­tridges may be purchased from your Independent Royal Prestige Representative. For purchase information you may also call the Royal Prestige Customer Service Center at 1-800-279-3373.
2. The actual capacity of your Cartridge may vary from the rated capacity. This may be due to the volume of contami­nants actually present in your water supply. Replace the Cartridge when the first of the following occurs:
Annually
When the red LED lamp begins flashing
(FP5000 & FP4500 models only)
The flow rate diminishes
When the rated capacity of the Cartridge has
been reached
When you notice a taste or odor reoccurrence
3. Read this manual completely before attempting to install or use this product.
4. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the System. Systems certified for cyst reduction may be used with disinfected water that may contain filterable cysts.
5. Individuals requiring specific microbiological purity should consult their physician.
FRESCAPURE™
FRESCAPURE™ 1
2 FRESCAPURE™
6. For use on cold potable water supplies only.
7. For this System to continue to perform as tested and rep­resented, use only Genuine, Royal Prestige NSF Certified Replacement Cartridges.
8. After set-up and installation, do not remove the Battery except when replacing the Cartridge (FP5000 & FP4500
models only).
9. Be sure to replace the Battery (CR 2032) each time a new Cartridge is installed (FP5000 & FP4500 models only). For your convenience, a new Battery is included with the pur­chase of each new Cartridge (FP5000 & FP4500 models
only).
10. Do not allow System to sit for extended lengths of time without being used (10 days or more). If System must be left unused for more than 10 days, drain all water from the System and remove the Cartridge. Once you return, re­install Cartridge and continue to use. In the event System is not used for 10 days or more, the System should be flushed for fifteen minutes prior to use.
11. This System must be protected from freezing failure to do so may result in loss of performance, damage to the parts and water leakage. If System is exposed to freezing temperatures, drain water from Filter Housing and remove Cartridge.
12. Installation of this product must comply with all state and local laws and regulations. Refer to your local agencies for details.
13. Installation of this product must comply with all state and local laws and regulations. Refer to your local agencies for details.
MODEL SPECIFICATIONS
MODEL FP5000
Model Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FP5000
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Counter-top
EPA Establishment Number . . . . . . . . . . . . . . . . . . . . 63018-NV-001
Rated Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .800 gallons
Replacement Cartridge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RC-50-FP
Replacement Battery . . . . . . . . . . . . . . . . . . . . . .2032 CR, 3V lithium
(included with RC-50-FP)
Filter Life Indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Electronic LED
Rated Service Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.75 gal/min
Housing Construction . . . . . . . . . . . . . Surgical Grade Stainless Steel
Base Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . .High Impact PP
Maximum Working Pressure . . . . . . . . . . . . . . 100 psig (689.5 kPa )
Minimum Working Pressure . . . . . . . . . . . . . . . .30 psig (206.8 kPa)
Maximum Operating Temperature . . . . . . . . . . . . . . . 100º F/38º C
(for cold water use only)
Minimum Operating Temperature . . . . . . . . . . . . . . . . . 34º F/ 1º C
Particle Retention Size. . . . . . . . . . . . . . . . . Sub-Micron (0.5 micron)
MODEL FP4500
Model Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FP4500
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Under-Counter
EPA Establishment Number . . . . . . . . . . . . . . . . . . . . 63018-NV-001
Rated Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .800 gallons
Replacement Cartridge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RC-50-FP
Replacement Battery . . . . . . . . . . . . . . . . . . . . . .2032 CR, 3V lithium
(included with RC-50-FP)
Filter Life Indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Electronic LED
Rated Service Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.75 gal/min
Housing Construction . . . . . . . . . . . . . Surgical Grade Stainless Steel
Lid Assembly . . . . . . . . . . . . . . . . . . . . Surgical Grade Stainless Steel
Maximum Working Pressure . . . . . . . . . . . . . . .100 psig (689.5kPa )
Minimum Working Pressure . . . . . . . . . . . . . . . . 30 psig (206.8kPa)
Maximum Operating Temperature . . . . . . . . . . . . . . . 100º F/38º C
(for cold water use only)
Minimum Operating Temperature . . . . . . . . . . . . . . . . . 34º F/ 1º C
Particle Retention Size. . . . . . . . . . . . . . . . . Sub-Micron (0.5 micron)
MODEL FP4000
Model Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FP4000
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Counter-top
EPA Establishment Number . . . . . . . . . . . . . . . . . . . . 63018-NV-001
Rated Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .800 gallons
Replacement Cartridge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RC-40-FP
Rated Service Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.75 gal/min
Housing Construction . . . . . . . . . . . . . Surgical Grade Stainless Steel
Base Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . .High Impact PP
Maximum Working Pressure . . . . . . . . . . . . . . 100 psig (689.5 kPa )
Minimum Working Pressure . . . . . . . . . . . . . . . . 30 psig (206.8kPa)
Maximum Operating Temperature . . . . . . . . . . . . . . . 100º F/38º C
(for cold water use only)
Minimum Operating Temperature . . . . . . . . . . . . . . . . . 34º F/ 1º C
Particle Retention Size. . . . . . . . . . . . . . . . . Sub-Micron (0.5 micron)
FRESCAPURE™ 3



4 FRESCAPURE™
MODEL FP5000
MODEL FP4500
MODEL FP4000
REPLACEMENT PARTS DIRECTORY
FRESCAPURE™ 5000
ITEM PART NUMBER DESCRIPTION
1 6-400-0003 Battery 2 4-104-0053 Battery Shuttle 3 9-904-0094 Filter Housing & Spout Assembly 4 9-904-0096 Decorative Cover Assembly 5 9-904-0093 Cartridge 6 9-902-0001 Clamp Assembly 7 9-904-0042 Filter Base with O-Ring 8 0531-50-05 3/8” Diverter Assembly 9 9-904-0023 3 piece Faucet Adapter Kit
GETTING STARTED:
Determine which model you have.
Open the shipping carton, remove the Drinking Water
System and all items and place them on your kitchen counter.
Compare items with illustrations to insure that all parts
were received.
Review the instructions for the FrescaPure™ model that
you have.
COUNTER-TOP MODEL INSTALLATIONS (FP5000 & FP4000)
1. Remove the aerator from the end of your kitchen
faucet, if it has one.
2. Attach the Diverter Valve directly onto your kitchen
faucet. DO NOT OVER-TIGHTEN.
3. If the threads to the Diverter Valve do not directly
FRESCAPURE™
UNDER COUNTER
ITEM PART NUMBER DESCRIPTION
1 9-904-0099 Lid Assembly 2 4-401-0017 O-Ring 3 9-904-0093 Cartridge 4 0581-04-11 Filter Housing 5 9-902-0003 Clamp Assembly 6 9-904-0094 Base 7 6-100-0008 Filter Life Indicator 8 4-104-0015 Battery Shuttle 9 6-400-0003 Battery 10 6-100-0010 LED Display 11 3-213-0015 3/8” Adapter 12 9-904-0089 Clean Water Faucet
attach to your kitchen faucet, use one of the three Adapters provided.
4. Most kitchen faucets with external threads will di-
rectly attach to the Diverter Valve. In some instanc­es the Diverter Valve may be smaller than your kitchen faucet. In this case use the Adapter with in­ternal threads and attach it directly to your kitchen faucet. Next, attach the Diverter Valve to the Adapter.
5. If your kitchen faucet has internal threads, attach one
of the two Adapters with external threads directly to your kitchen faucet. Next, attach the Diverter Valve to the Adapter.
6. If your kitchen faucet does not have threads, measure
the inside diameter of the kitchen faucet and provide this information to your Independent Royal Prestige
ITEM PART NUMBER DESCRIPTION
FRESCAPURE™ 4000
1 9-904-0095 Filter Housing & Spout Assembly 2 9-904-0297 Decorative Cover Assembly 3 9-904-0036 Cartridge 4 9-902-0001 Clamp Assembly 5 9-904-0042 Filter Base with O-Ring 6 0531-50-05 3 Piece Faucet Adapter Kit 7 9-904-0023 3/8” Diverter Assembly
Representative or to the Royal Prestige Customer Service Center (1-800-279-3373). Be sure to request an expandable adapter.
7. If your kitchen faucet does not fit any of the Adapters
provided, send the threaded aerator to your Independent Royal Prestige Representative or to the Royal Prestige Cus­tomer Service Department. Include a note requesting an adapter that fits your threaded aerator.
FRESCAPURE™ 5
Loading...
+ 7 hidden pages