0102 095 51642
Slimline Std Mk2 LPG
Slimline standard Mk 2
User, Installation & Servicing Instructions
This appliance is for use on PROPANE
Please hand this booklet to the user and advise to keep in a safe place
Important Notice: Before disposal of the outer packaging, please enter the product code, purchase and
installation details in section 1.1 of this booklet.
Multiflue
GAS (G31) ONLY at a supply p r es sure of 37mbar
G.C. No 32-187-41B
MM79 010710
This booklet details instructions for USER (section 1), INSTALLATION (section 2) & SERVICING (section 3).
IMPORTANT
NOTICE
It is important for the safe and continued operation of this appliance that the instructions contained in this booklet are
observed!
TABLE
OF CONTENTS
Section 1.0 Instructions for Use
1.1 Record of purchase/installation
1.2 Important notes
1.3 Lighting and extinguishing the appliance
1.4 Re-laying the coal/pebble bed
1.5 Spare parts
1.6 Guarantee
Section 2.0 Installation Instructions
2.1 Important notes
2.2 Statutory requirements
2.3 Technical data
2.4 Installing the appliance (Ventilation)
2.4.1 Flue
2.4.2 Clearance to sides and shelves
2.4.3 Hearth Clearances
2.4.4 Fitting the appliance in position
2.4.4.1 Restrictor plate
2.4.4.2 Fitting the firebox in the opening
2.4.4.3 Connecting the gas supply
2.4.4.4 Che c k i ng t he appliance set t ing pressure
2.4.4.5 Checking the correct operation
2.5 Laying the coal/pebble bed
2.6 Clearance of combustion products
2.7 Front and Frets (requirements for ventilation)
2.8 Advising the customer
Section 3.0 Maintenance and Servicing
3.1 Removal of debris or soot
3.2 Servicing components below the heat engine
3.3 Spare parts
3.4 Useful telephone numbers
Page 1
MM79 010710
Section 1 – Instructions for Use
1.1 RECORD OF PURCHASE/INSTALLATION Slimline Standard Mk2
Purchase Details
Date of purchase ______ / ______ / ______
Purchase from _____________________
Address _____________________
_________________________________________
Installation Details
Date of installation ______ / ______ / ______
Installed by _____________________
Registration number _____________________
Telephone number _____________________
ppliance Details
Serial number _____________________
(located on rating label)
Product Code _____________________
(located on white label on outer carton)
It is advisable to have all the above information
available if assistance is required. It will aid our
service department in helping you more efficiently.
MM79 010710
Page 2
1.2 IMPORTANT NOTES Slimline Standard Mk2
CAUTION – THIS PACKAGE WEIGHS 16Kgs – assess the load before you move it and note any other handling
information on the packaging. If you think the load is beyond your safe capability, DO NOT PUT YOURSELF AT RISK!
Seek assistance from other person(s) and/or use appropriate handling equipment. IT’S YOUR BODY – LOOK AFTER IT!
This appliance is for DECORATIVE PURPOSES ONLY and is manufactured to the requirements of the current issue of EN 509.
This appliance is for use on PROPANE GAS
This appliance MUST
Ventilation for this appliance must be fitted in accordance with the rules in force and checked regularly for obstructions.
If the appliance is installed in GREAT BRITAIN, additional ventilation is NOT normally required.
If the appliance is installed in IRELAND, a minimal cross sectiona l area of 100c m
Any permanent flue restriction must be removed and any variable dampers locked fully open or removed. If the flue has been
used previously for solid fuel, it MUST be swept PRIOR to installation.
If soot accumulation becomes excessive, the fuel effect pieces should be removed from the appliance for cleaning. Cleaning
should be carried out in a sufficiently ventilated area or in the open air, by gently brushing with the pieces held away from your
face so that you avoid inhaling the dust. THE USE OF A NORMAL VACUUM CLEANER IS NOT RECOMMENDED as dust may
be blown back into the room.
This appliance has a naked flame and a fireguard to the current iss ue of BS 8423 - 2002 should be used for the protection o f
children, the elderly and the infirm.
Care must be taken on the selection of wall coverings within close proximity of the appliance as some vinyl and embossed
materials may become discoloured b y convected heat. Sof t furnishings must be kept clear from the radian t heat of the appliance
and from impinging the hearth area . Combustible mat erials must not be put o n or left in the hearth area nor should the co al bed
be used to burn rubbish or other materials.
This appliance uses fuel effect components, gaskets and insulation material containing Refractory Ceramic Fibre, (RCF), which
are man-made vitreous silica te fibres. Excessive exposur e to such material ma y cause temporar y irritation to the e yes, skin and
respiratory tract. Consequently, it makes sense to take care when handling these articles to ensure that the release of dust is kept
to a minimum.
This appliance is fitted with an OD S, a spillage m onitoring syste m which opera tes if the eva cuation of pr oducts is int errupted (i.e.
blocked or incorrect flueing). If the appli ance repe atedl y `go es out’ it ma y indicate a problem and the ins taller or spec ialist s hould
be consulted before further use.
The minimum temperature rating of any back panel or hearth must have a minimum fire resistance rating of CLASS 0 (100
If any home improvements, e.g. double glazi ng, are carried out after this appliance has been installed, you should co ntact your
Registered Installer and have the operat io n o f the flue checked.
1.3 LIGHTING AND EXTINGUISHING THE APPLIANCE
1. Remove the fret (Fig. 1), to gain access to the controls (Fig. 2).
Fig. 1
2. Press and turn the gas control anti-clockwise to the `IGN’ position. Keep the control fully depressed.
3. Press and release the pie z o button until the main burner behi nd the simulated front coal has lit .
4. Once lit, keep the gas control depressed for a further 15 seconds.
5. Release the gas control and chec k that the main burner has remained alight.
6. Press and turn the gas control anti-clockwise to the required setting. Replace the fret (controls cover).
7. To turn the appliance off, depress and turn the gas control clockwise from any position to the `OFF’ position.
8. In the event of the piezo button failing, the appliance ma y be lit by placing a lighted taper or match at the main burner while
depressing the gas control in the `IGN’ position.
IMPORTANT
After turning off or if the appliance goes out for any reason, wait for three minutes before attempting to relight.
be installed by a REGISTERED INSTALLER. Failure to do so may lead to prosecution.
(G31) ONLY, at a supply pressure of 37mbar +/- 1mbar.
2
is required.
Fret Gas Control Piezo Button
o
C).
Fig. 2
Page 3
MM79 010710
1. 4 RE - LAYING THE COAL/PEBBLE BED Slimline Standard Mk2
Fig. 3
The support shelf is positioned on the fibre
support metalwork. There are two metal `stops’ that
prevent the support shelf from sitting on the main
burner outlet (Fi g. 3).
Metal `stops’
Fig. 4
The simulated front is positioned on the shelf directly
in front of the support shelf. Two metal `stops’ locate the
simulated front in position.
Fit the two front retaining brackets with two No 8x3/8 screws supplied
in the fixing pack to secure the front into position (Fig. 4).
Note: Large coals/pebbles (grey) and small coals/pebbles
(black) are coloured for illustration purposes only !
Metal `stops’
Fig. 5
Front Retaining Bracket
Place 3 large and 2 small coals/pebbles on top of the simulated
front (one in each groove). Allow the coals/pebbles to rest on
the support shelf. Place 3 large coals/pebbles on the upper tier
of the support shelf (Fig. 5).
Fig. 6
Place 4 small coals/pebbles between the 5 coals/pebbles located
on top of the simulated front. Allow the coals/pebbles to rest on the
3 large coals/pebbl es located on the top tier of the support shelf.
Place 2 small coals/pebbles between the 3 large coals/pebbles
located on the top tier of the support shelf (Fig. 6).
To obtain the best visual appearance, it may be necessary to `slightly’ adjust the position of the coals.
If any of the coals or coal bed become damaged or lost, replacements MUST be obtained before further use.
ADDITIONAL COALS/PEBBLES MUST NOT BE USED
Page 4
MM79 010710
1.5 SPARE PARTS Slimline Standard Mk2
For a list of spare part s for this appliance, please refer to section 3.3.
1.6 GUARANTEE
Please complete the registrati on section of the white card supplied in the IFU kit. Any part of this appliance is gu aranteed agai nst the
manufacturer’s defective workmanship or fault y materi als for a period of twelve months from the date of purchase.
Any such part will be replaced free of charge on receipt of the purchaser’s address at the cost of postage only.
Please take time to fill in section 1.1 of this booklet for your future reference.
Page 5