Rowenta PU4020U0, PU6020U0 User Manual

EN
FR
ES
903953/01 - 06/15
ROWENTA INTENSE PURE AIR
PU4020U0/PU6020U0
www.rowenta.com
E
C
F
F
I
1
6 7 8 9 10
2 3 4 5
DISASSEMBLING/REASSEMBLING FILTERS
1 2 3
6
54
CLICK !
CLICK !CLICK !
CLICK !
CLICK !CLICK !
CLICK !CLICK !CLICK !
7 8 9
Montage/Démontage des Filtres - Instalación/Desmontaje de los filtros
3
DESCRIPTION
Product description
A Ambient light B Adjustable air outlet grid C Control panel D Front door E Handle F Air inlets G Particle sensor H
Gas sensor (
I Power cord outlet
Read the instructions for use and safety carefully before use and keep them for future reference.
U6020 full size only)
P
Control panel Lights
1 Filter replacement indicator 2 Air quality indicator 3 Filtration speed 4 Mode (auto, night, manual) 5 Timer / delayed start
Control buttons
6 Light 7 Filter reset 8 Start 9 Mode/filtration speed
selection 10 Timer / delayed start set­ting
SAFETY TIPS
It is essential that you read these instructions carefully and observe the following recommendations:
For your safety, this appliance complies with the applicable
standards and regulations (low voltage, electromagnetic compatibility, environmental directives, etc.).
This appliance should not be used by persons (including children)
with reduced physical, sensory or mental capacities or lack of experience and knowledge, unless they are supervised or have been given instructions beforehand concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure they do not play with the
appliance.
The appliance can be used by children aged 8 and over and
persons with a lack of experience or knowledge or reduced physical, sensory or mental capacities, provided they are supervised, have been trained on the safe use of the appliance and are aware of the risks involved. Children must not play with the appliance.
If the power cord is damaged, it must be replaced by the
manufacturer, its after-sales service or a similarly qualified person so as to avoid any danger.
Children should not clean or perform maintenance on the
appliance without being supervised.
For maintenance operations, please refer to the "Maintenance"
section.
Keep the appliance and its power cord out of the reach of children
aged under 8.
• This appliance is designed for domestic use only. It should not be used for industrial purposes.
• The warranty will be invalidated if damage occurs due to incorrect use.
4
• Do not operate this appliance in a very dusty and/or humid place or in a location with fire hazards.
• Before use, always make sure that the appliance, plug and power cord are in good condition.
• Never insert objects into the appliance (e.g. needles, etc.).
• Do not pull on the power cord or the appliance, even to unplug it from the wall power outlet.
• Unroll the full length of the cord before use.
VERY IMPORTANT
• Do not cover the air inlets or the outlet grid.
• Do not touch the appliance with wet hands.
• Never allow any liquid to enter the appliance.
• Never use the appliance in a humid place.
• Never use the appliance close to a heat source.
• Never place anything on the appliance or insert anything into it.
• Do not use the appliance close to flammable objects or products (curtains, aerosols, solvents, etc.).
• Never use the appliance in an inclined or horizontal position. Place the appliance on a flat, stable surface.
• In the case of prolonged absence: switch the appliance off using the button (8) and unplug it.
• Switch off and unplug your appliance before moving it.
• Unplug the air purifier during assembly and cleaning.
OPERATING PRINCIPLE
The new Intense Pure Air purifier from Rowenta enables you to breathe up to 99.97% pure air in your home and protect your health with 4 filtration levels as described below. Each level is essential and traps specific pollutants :
LEVEL 3:
HEPA FILTER
• Fine particles (PM2.5)
• Pollen
• Dust mites
• Animal allergens
• Mold
• Bacteria / viruses
LEVEL 1:
PRE-FILTER
• Dust
• Hair
• Fur
• Lint
EN
LEVEL 4:
NANOCAPTUR FILTER
• Formaldehyde
Formaldehyde is the most harmful indoor air pollutant.*
*Ranking established by the ANSES, French Agency for Food, Environmental and Ocupational Health and Safety, 2010
LEVEL 2:
ACTIVE CARBON FILTER
• Volatile organic components (VOCs)
• Odors / gases
5
« HOW TO ACHIEVE CLEANER INDOOR AIR »
In addition to using your Intense Pure Air purifier, here are some tips on how to improve the quality of your indoor air: • Ventilate the rooms for at least 10 min. every day, in summer and winter • Maintain your ventilation system • Limit the use of household products • Do not smoke indoors • Avoid home fragrances, incense sticks, scented candles, etc. • Ventilate whenever any work is being conducted in your home and for several weeks
afterwards
• Avoid green plants that are allergenic or need frequent watering
WHERE TO INSTALL THE APPLIANCE
Place the purifier on a flat, stable surface in the room requiring treatment. To allow the air to circulate freely, avoid placing the appliance behind curtains, below a window, item of furniture or shelf unit, or close to any other obstacle, and leave at least 50 cm of free space above in front of and on each side of the appliance.
BEFORE USING THE APPLIANCE FOR THE FIRST TIME
Make sure that the plastic packaging protecting the filters has been removed before using the appliance.
Also make sure that:
• The voltage of your electrical installation corresponds to the one indicated on the appliance. Your appliance can be used with a power plug without an earth connection. It is a class II appliance (double electrical insulation),
• The appliance is positioned in the house as described above,
• The air inlet and outlet grids are completely unobstructed,
• Ensure the 4 filters and front panel have been correctly installed (see section « Disassembling / Reassembling filters »).
This appliance is fitted with a device that automatically prevents it from operating if the front door is not correctly assembled.
Inserting the filters
This appliance is equipped with 4 types of filters:
Pre-filter Active carbon
filter
NB: For optimum performance of the appliance, only use filters provided by ROWENTA.
To install the filters, follow the instructions in the section « Disassembling/Reassembling filters ».
Please note: certain filters may emit a temporary slight odour, due to the transport and storage conditions.
HEPA filter
NanoCaptur
filter
6
SWITCHING THE APPLIANCE ON
Connect the power cord and press the start button (8).
Your appliance will be preset to automatic mode the first time you turn it on. Thanks to its infrared particles sensor and its gas sensor (model PU6020 full size only), it detects the level of pollution in the room and automatically adjusts the filtration speed accordingly. A light changes color to indicate the quality of air in the room.
EN
Air quality Color of light
Excellent Blue
Average Purple
Poor Red
Filtration speed
(in auto mode)
SETTING THE POLLUTION SENSORS
The appliance is preset to medium sensitivity. If the air quality indicator remains:
- poor after 2 hours in operation although the air seems to be purified
- excellent for more than 1 hour although the air seems to be polluted
you can adjust the sensor sensitivity as follows:
1. When the air purifier is off, hold down the filtration speed setting button for 2 seconds:
2. Set the sensitivity by briefly pressing the filtration speed setting button:"
+ Blue + Purple + Red
Low sensitivity Medium sensitivity High sensitivity
• Select high sensitivity if the air purifier indicates excellent air quality for more than 1 hour
although the air seems to be polluted.
• Select low sensitivity if the air purifier continues to indicate poor air quality even though it has
been operating for more than 2 hours and the air seems sufficiently purified.
3. The new setting is applied if no button is pressed for 10 seconds.
OPERATION
START
Briefly press this button to switch the air purifier on or off.
MODE/FILTRATION SPEED SELECTION
Automatic: In this operating mode, the filtration speed automatically adjusts according to the air quality detected by the particles sensor and the gas sensor (model PU6020 full size only). This mode is recommended for general use.
Night: The filtration speed of your appliance is adjusted for a whisper quiet air flow during the night. The light intensity of the appliance is also reduced. If pollution is detected, the filtration speed increases slightly to purify your air but remains quiet to avoid disturbing your sleep.
Manual: In this operating mode, you can manually select 1 of the 4 filtration speeds.
LIGHT
You can change the light intensity of the appliance as you wish or according to the time of day.
7
Press Ambient light Air quality indicator Control panel
1 Light up Light up Light up 2 Moderate light Moderate light Moderate light 3 Off Moderate light Moderate light 4 Off Off Moderate light
TIMER / DELAYED START
If the appliance is on: you can use the button 10 to define the operating duration. Briefly press the button to select the number of operating hours desired (1, 2, 4 or 8) and the appliance will automatically turn off at the end of the selected period. If the appliance is off: briefly press the button 10 to set the appliance to turn on in a certain number of hours (1, 2, 4 or 8).
3D PURE AIR FUNCTION (adjustable grid)
You can adjust the position of the air outlet grid manually, as desired. For an optimum, even flow of purified air in the room, set the angle to 45°; for optimized well-being, set the angle to 90°.
MAINTENANCE
Always switch the appliance off with the button (8) and unplug it before conducting any maintenance operation.
You can clean the outer of the appliance with a slightly damp cloth.
IMPORTANT: Never use abrasive products which could damage your appliance’s appearance.
FILTERS
Filter Action Cycles
Pre-filter Clean Every 2 to 4 weeks Active carbon filter Replace Every 12 months HEPA filter Replace Every 3 years
NanoCaptur filter Replace
Color changing
(see Color chart on filter)
This data is based on an average use of 8 hours per day at speed 2. The recommended frequency for cleaning and replacing the filters may vary depending on the duration of use and the operating environment.
• A “HEPA” light indicates when the HEPA filter needs to be replaced.
The 'Odor' light indicates when the carbon filter needs to be replaced.
• The NanoCaptur filter contains translucent granules which change color according to the formaldehyde
absorption rate. Refer to the color chart on the inside of the panel or the filter itself to establish the filter saturation rate.Once the saturation rate has reached its maximum, the filter must be replaced. You have to check the filter saturation rate every six months.
• The pre-filter can be re-used: remove the dust using a vacuum cleaner or wash with water.
CAUTION:
• The appliance's efficiency can be reduced if the pre-filter is not cleaned regularly.
• Never use a pre-filter that is still damp.
• The pre-filter is the only filter which can be re-used and washed with water. The HEPA,
NanoCaptur and active carbon filters cannot be cleaned and re-used. Never wash with water.
• To replace the filters, follow the instructions in the section « Disassembling/Reassembling filters ».
8
Loading...